TK3S Series In Line Paddle Wheel Flow Meter Sensor
“
Product Information
Specifications
- Operating Range: 0.3 to 33 ft/s, 0.1 to 10
m/s - Pipe Size Range: DN08 to DN100
- Linearity: Repeatability
- Fluid: Water or Chemical Liquid – Viscosity
Range: 0.5-20 centistokes - Flow Velocity: 10 m/s max.
- Low Cut: 0.3 m/s min.
- Operating Pressure: 150 Psi (10 Bar) @ Ambient
Temp | Non-Shock
Product Usage Instructions
Safety Information
Before installation or removal, ensure to de-pressurize and vent
the system. Confirm chemical compatibility before use. Do not
exceed maximum temperature or pressure specifications. Always wear
safety goggles or face-shield during installation and/or service.
Do not alter product construction.
Installation Warnings
- Pressurized System Warning: Vent the system
prior to installation or removal to prevent equipment damage or
injury. - Pressurize System Warning: Ensure the sensor
is not pressurized before working on it to avoid equipment damage
or injury.
Installation Guidelines
The TK Series can be installed in a horizontal or vertical
direction. Maintain a minimum of 10x pipe diameters upstream and 3x
pipe diameters downstream. Use a Bag Filter or Y Strainer Filtering
Device upstream to protect the paddle wheel from damage by solids
or fibers.
Avoid intensified turbulent flow that can affect readings by
ensuring enough length of straight pipe. Do not flush the pipe with
compressed air after installing the Flow Meter as it may damage the
ceramic shaft and void the warranty.
Product Description
The TK Series in-line plastic paddle wheel flow meter is
designed for accurate flow measurement in tough industrial
applications. Features include M12 Quick Connection, True Union
Design, High Impact Enclosure, and Bright LED Display for flow
monitoring.
The TK3S model offers a Flanged Connection, 316 Stainless Steel
construction, Sanitary Connection, and Zirconium Ceramic Rotor with
Bushings for increased wear resistance and longevity compared to
regular ceramic designs.
FAQ
Q: Can the flow meter be installed vertically?
A: Yes, the TK Series can be installed in a horizontal or
vertical direction.
Q: What is the maximum operating pressure?
A: The maximum operating pressure is 150 Psi (10 Bar) at ambient
temperature, non-shock conditions.
Q: What precautions should be taken during installation?
A: Ensure to de-pressurize and vent the system before
installation or removal, confirm chemical compatibility, wear
appropriate protective gear, and maintain proper pipe lengths and
filtering devices as specified in the manual.
“`
Truflo® — TKS | TK3S Series
In-Line Paddle Wheel Flow Meter Sensor
Quick Start Manual
Read the user’s manual carefully before starting to use the unit. Producer reserves the right to implement changes without prior notice.
2F4i-n05d64Qu©aIclointyPrPocreossdCuoncttroslsOLtdn. line at:
Valuetesters.com
info@valuetesters.com1
Truflo® — TKS | TK3S Series
In-Line Paddle Wheel Flow Meter Sensor
Safety Information
De-pressurize and vent system prior to installation or removal Confirm chemical compatibility before use DO NOT exceed maximum temperature or pressure specifications ALWAYS wear safety goggles or face-shield during installation and/or service DO NOT alter product construction
Warning | Caution | Danger
Indicates a potential hazard. Failure to follow all warnings may lead to equipment damage, injury, or death.
Note | Technical Notes
Highlights additional information or detailed procedure.
Personal Protective Equipment (PPE)
Always utilize the most appropriate PPE during installation and service of Truflo® products.
Pressurized System Warning
Sensor may be under pressure. Take caution to vent system prior to installation or removal. Failure to do so may result in equipment damage and/or serious injury.
Please ensure that the Instruments are not to be subject to water hammer or pressure spikes! Always Pressure Test System with H2O Prior to Initial Start-Up
Before installation be certain the appropriate instrument has been selected considering operating pressure, full scale pressure, wetted material requirements, media compatibility, operating temperature, vibration, pulsation, desired accuracy and any other instrument component related to the service application including the potential need for protective attachments and/or special installation requirements. Failure to do so could result in equipment damage, failure and/or personal injury. Ensure only qualified personnel are permitted to install and maintain this instrument.
Pressurize System Warning
Sensor may be under pressure, take caution to vent system prior to installation or removal. Failure to do so may result in equipment damage and/or serious injury.
Please Ensure Full Pipe
TK Series can be installed in a horizontal or vertical direction. Please ensure enough length of straight pipe to avoid intensified turbulent flow that can effect readings.
Min 10x Pipe Diameters Upstream 3x Pipe Diameters Downstream (See Page 10)
A Bag Filter or Y Strainer Filtering Device upstream to Avoid the Paddle Wheel from being damaged by the solids or fibers – max 10% Particle Size – Not to Exceed .5mm Cross Section or Length. Please do not flush the pipe after the Flow Meter is installed with compressed air this may damage the ceramic shaft and will void warranty.
2F4i-n05d64Qu©aIclointyPrPocreossdCuoncttroslsOLtdn. line at:
Valuetesters.com
info@valuetesters.com2
Truflo® — TKS | TK3S Series
In-Line Paddle Wheel Flow Meter Sensor
Product Description
TKS
The TK Series in-line plastic paddle wheel flow meter has been engineered to provide long-term accurate flow measurement in tough industrial applications.
The paddle wheel assembly consists of a engineered Tefzel® paddle and micro-polished zirconium ceramic rotor pin and bushings. High performance Tefzel® and Zirconium materials have been selected due to their excellent chemical and wear resistant properties.
M12 Quick Connection
Rotates 360º
True Union Design High Impact Enclosure
Bright LED Display (Flow)
New ShearPro® Design
? Contoured Flow Profile ? Reduced Turbulence = Increased Longevity ? 78% Less Drag than Old Flat Paddle Design*
*Ref: NASA “Shape Effects on Drag”
TK3S
Tefzel® Paddle Wheel ? Superior Chemical And Wear Resistance vs PVDF
Flanged Connection
316 Stainless Steel
Sanitary Connection
Zirconium Ceramic Rotor | Bushings
? Up to 15x the Wear Resistance vs Regular Ceramic ? Integral Rotor Bushings Reduce Wear
and Fatigue Stress
ShearPro® Through-Pin Design
? Eliminates Finger Spread ? No Lost Paddles ? Increased Temp. Rating ? 360° Housing Protects Rotor
vs. Flat Paddle
Finger Spread = LOST Unprotected Rotor
TKS
Thermal Plastic
vs. Competitor `A’
2F4i-n05d64Qu©aIclointyPrPocreossdCuoncttroslsOLtdn. line at:
TK3S
316 SS
Valuetesters.com
info@valuetesters.com3
Truflo® — TKS | TK3S Series
In-Line Paddle Wheel Flow Meter Sensor
Technical Specifications
General
Operating Range
0.3 to 33 ft/s
0.1 to 10 m/s
Pipe Size Range
¼ to 4″ **
DN08 to DN100
Linearity
±0.5% of F.S @ 25°C | 77°F
Repeatability
±0.5% of F.S @ 25°C | 77°F
Fluid
Water or Chemical Liquid-Viscosity Range: .5-20 centistokes
Flow Velocity
10 m/s max.
Low Cut
0.3 m/s min.
Operating Pressure
150 Psi (10 Bar) @ Ambient Temp |Non-Shock
Range Ability
10 : 1
Response Time
Real Time
Flow Total Meter
Range = 0~999999 ; Unit = Gallon or Liter or Ton (KL) Selectable
Repeatability
Range = 0.0~999.9 ; Unit = GPM or LPM or CMH Selectable
Accuracy
± 0.5% of F.S. @ 25°C
Wetted Materials
Sensor Body
PVC (Dark) | PP (Pigmented) | PVDF (Natural) | 316 SS
O-Rings
FKM | EPDM* | FFKM*
Rotor Pin | Bushings
Zirconium Ceramic | ZrO2
Paddle | Rotor
ETFE Tefzel®
Electrical
Frequency
49 Hz per m/s nominal
15 Hz per ft/s nominal
Supply Voltage
9 to 30 VDC ±10% regulated
Supply Current
<1.5 mA @ 3.3 to 6 VDC
<20 mA @ 6 to 24 VDC
Max. Temperature/Pressure Rating Standard and Integral Sensor | Non-Shock
PVC
180 Psi @ 68°F | 40 Psi @ 140°F
12.5 Bar @ 20°C | 2.7 Bar @ 60°C
PP
180 Psi @ 68°F | 40 Psi @ 190°F
12.5 Bar @ 20°C | 2.7 Bar @ 88°C
PVDF
200 Psi @ 68°F | 40 Psi @ 240°F
14 Bar @ 20°C | 2.7 Bar @ 115°C
316 SS
200 Psi @ 180°F | 40 Psi @ 300°F
14 Bar @ 82°C | 2.7 Bar @ 148°C
Operating Temperature
PVC PP PVDF 316 SS
32°F to 140°F -4°F to 190°F -40°F to 240°F -40°F to 300°F
0°C to 60°C -20°C to 88°C -40°C to 115°C -40°C to 148°C
Outputs
NPN Pulse | 1 Amp Relay
Display
LED | Flow Rate
Standards and Approvals
UL | CE | FCC | RoHS Compliant See Temperature and Pressure Graphs for more information
*Optional ** ¼” – ” SS Only
2F4i-n05d64Qu©aIclointyPrPocreossdCuoncttroslsOLtdn. line at:
Valuetesters.com
info@valuetesters.com4
Truflo® — TKS | TK3S Series
In-Line Paddle Wheel Flow Meter Sensor
Exploded View
1
2
7
5
6
8
3 4
1
PC Cover
2
TKS Controller
3
Rotor Assembly
4
Body – PVC | PP | PVDF
5
Rotor Pin
6
Rotor Bushing
7
ShearPro® Paddle Wheel
8
Reinforced Inserts
2″
1/2″ Same Controller | Rotor Assembly for All Sizes
Wiring Diagram
TKS – NPN Pulse | Relay
TKS Flow Meter Output Circuit
Brown Black Grey White Blue
Load
1 AMP
+VDC NPN
NO COM
0V
Wire Color Brown Blue Black White Grey
Description + 10~30VDC
-VDC Flow Rate Pulse Output (OP1)
COM NO
2F4i-n05d64Qu©aIclointyPrPocreossdCuoncttroslsOLtdn. line at:
Valuetesters.com
info@valuetesters.com5
Truflo® — TKS | TK3S Series
In-Line Paddle Wheel Flow Meter Sensor
Programming
STEPS
1
Home Screen
+F
3 Sec.
2
Lock Settings
3
K Factor
4
Flow Unit
5
Pulse Output Control
6
Alarm Mode Setting
7
Alarm Output Delay
Select/Save/Continue
F
Move Selection Left
DISPLAY
OPERATION
Home Screen
Change Digit Value
Lock Settings Factory Default: Lk = 10 Otherwise meter will enter Lockout Mode*
K Factor Value Enter K Factor value depending on pipe size. Refer to Page 7 for K-Factor Values
Flow Unit Ut.0 = Liter | Ut.1 = Gallon (Factory Default) | Ut.2 = Kiloliters
Pulse Output Control Con.E = One Pulse/Gal (Factory Default) Con.F = Paddle Pulse Frequency Max 5 KHZ
Alarm Mode Setting Factory Default: ALt = 0 Range: 0~3 | Refer to Alarm Mode Selection ( See below)
Alarm Output Delay Factory Default: t = 20 Range: 01 ~ 99 Secs
Alarm Mode Selection
ALt No.
ALt = 0 ALt = 1
Description CV SV — Relay ON | CV < [SV – d] — Relay OFF CV SV — Relay ON | CV > [SV + d] — Relay OFF
ALt = 2 [SV + d] CV [SV – d] — Relay ON : CV > [SV + d] or CV < [SV – d] — Relay OFF
ALt = 3
[SV + d] CV [SV – d] — Relay OFF: CV > [SV + Hys] or CV < [SV – d] — Relay ONd = Hysteresis — Acts like a buffer ± around Alarm Set Point
CV: Current Value (Flow Rate) | SV = Set Value
2F4i-n05d64Qu©aIclointyPrPocreossdCuoncttroslsOLtdn. line at:
Valuetesters.com
info@valuetesters.com6
Truflo® — TKS | TK3S Series
In-Line Paddle Wheel Flow Meter Sensor
Programming Relay
STEPS
1
Home Screen
3 Sec.
2
Relay Set Point
Select/Save/Continue
F
Move Selection Left
DISPLAY
OPERATION
Home Screen
Enter Relay Set Point Factory Default: 100 Range: 0 ~ 999.9
Change Digit Value
3
Hysterisis
Enter Hysterisis Value Factory Default: 1.0 Range: 0 ~ 99.9
K-Factors for TK Series (V1)
Size ¼” ” ½” ¾” 1″ 1½” 2″ 3″ 4″
LPM 547 300 127.6 81.8 55.1 18.8 10.2 4.7 2.1
GPM 2079 1140 484.9 310.8 209.4 71.4 38.8
18 8
K-Factor is Pre-Programmed
K-Factors for TK Series (V2)
Size ½” ¾” 1″ 1½” 2″ 2½”
K-Factor 127.6 81.8 55.1 18.8 10.2 6.0
Min/Max Flow Rates
Pipe Size (O.D.)
DN08 DN10 DN15 DN20 DN25 DN40 DN50 DN65 DN80 DN100
(¼”) (“) (½”) (¾”) (1″) (1½”) (2″) (2½”) (3″) (4″)
LPM | GPM 0.3m/s min.
0.6 | 0.16 1.8 | 0.48 3.5 | 1.0 5.0 | 1.5 9.0 | 2.5 25.0 | 6.5 40.0 | 10.5 60.0 | 16.0 90.0 | 24.0 125.0 | 33.0
LPM | GPM 10m/s max.
12 | 3 50 | 13 120 | 32 170 | 45 300 | 79 850 | 225 1350 | 357 1850 | 357 2800 | 739 4350 | 1149
SS Only SS Only
2F4i-n05d64Qu©aIclointyPrPocreossdCuoncttroslsOLtdn. line at:
Valuetesters.com
info@valuetesters.com7
Truflo® — TKS | TK3S Series
In-Line Paddle Wheel Flow Meter Sensor
Temperature | Pressure Graphs | Non-Shock
Note: The Pressure/Temperature graphs are specifically for the Truflo® Flow Meter Sensors.
During system design the specifications of all components must be considered.
= PVC
Bar Psi 15.2 220
13.8 200
12.4 180
11.0 160
9.7 140
8.3 120
6.9 100
5.5 80
4.1 60
2.8 40
1.4 20
00
ºF 68
104
ºC 20
40
= PP
140
175
60
80
= PVDF
212
248
100
120
Model Selection
Size ½” ¾” 1″ 1 ½” 2″ 3″ 4″
PVC
End Connections Sch 80 Soc Sch 80 Soc Sch 80 Soc Sch 80 Soc Sch 80 Soc Flanged Flanged
Part Number TKS-15-P TKS-20-P TKS-25-P TKS-40-P TKS-50-P TKS-80-P TKS-100-P
Add 1st Suffix (end connection): -T NPT End Connectors (on PVC) -B Butt Fused End Connections for PP or PVDF -F Flange ANSI 150lb – Consult Factory
Size ½” ¾” 1″ 1 ½” 2″ 3″ 4″
PP
End Connections NPT NPT NPT NPT NPT
Flanged Flanged
Add 2nd Suffix (seals):
FKM (std, no suffix required) -E EPDM Seals -K FFKM | Kalrez® Seals
Part Number TKS-15-PP TKS-20-PP TKS-25-PP TKS-40-PP TKS-50-PP TKS-80-PP TKS-100-PP
Size ½” ¾” 1″ 1 ½” 2″
PVDF
End Connections NPT NPT NPT NPT NPT
Part Number TKS-15-PF TKS-20-PF TKS-25-PF TKS-40-PF TKS-50-PF
PVC Socket Ends (Std) Note:
PP/PVDF NPT Ends (Std)
Size ¼” ” ½” ¾” 1″ 1 ½” 2″ 3″ 4″
316 SS
End Connections NPT NPT NPT NPT NPT NPT NPT NPT NPT
Part Number TK3S-08-SS TK3S-10-SS TK3S-15-SS TK3S-20-SS TK3S-25-SS TK3S-40-SS TK3S-50-SS TK3S-80-SS TK3S-100-SS
Add 1st Suffix (end connection): -T NPT End Connectors -SE Sanitary – Consult Factory for Pricing -F Flange ANSI 150lb – Consult Factory
Add 2nd Suffix (seals):
FKM (std, no suffix required) -E EPDM Seals -K FFKM | Kalrez® Seals
2F4i-n05d64Qu©aIclointyPrPocreossdCuoncttroslsOLtdn. line at:
316SS PC
PVC
PP PVDF
Valuetesters.com
info@valuetesters.com8
Truflo® — TKS | TK3S Series
In-Line Paddle Wheel Flow Meter Sensor
Dimensions
L 2.2
Pipe Size L (inch) D (inch) C (inch)
½” DN (15) ¾” DN (20) 1″ DN (25) 1½” DN (40) 2″ DN (50)
5.48 6.12 6.76 7.66 8.40
1.07 1.36 1.68 2.33 2.86
1.61 2.08 2.36 3.26 4.33
1.8
1.85
C
Procedure to Rotate Display
1
Flow Meter & Transmitter
OP2
FTM
OP1
GPM
2
D C
Flow Meter & Transmitter
OP2
FTM
OP1
GPM
3
OP2
FTM
OP1
GPM
Using an allen key loosen the 2 screws located on either side of the display.
Pull the Screws | Do Not Remove!
4
5
6
Lift the Display.
Flow Meter & Transmitter OP2 FTM OP1 GPM F
Flow Meter & Transmitter OP2 FTM OP1 GPM F
Flow Meter & Transmitter OP2 FTM OP1 GPM F
Rotate Display 90°.
2F4i-n05d64Qu©aIclointyPrPocreossdCuoncttroslsOLtdn. line at:
Lower Display.
Tighten Allen Screws | Snug Tight Do Not Over-Tighten!
Valuetesters.com
info@valuetesters.com9
Truflo® — TKS | TK3S Series
In-Line Paddle Wheel Flow Meter Sensor
Installation Position
10x
3x
CORRECT
INCORRECT
10x
CORRECT
3x
CORRECT
INCORRECT
10x
3x
INCORRECT
CORRECT
10x
3x
INCORRECT
Please Ensure Full Pipe
TK Series can be installed in a horizontal or vertical direction. Please ensure enough length of straight pipe to avoid turbulence that can effect readings.
Note: Min 10x Pipe Diameters Upstream 3x Pipe Diameters Downstream.
A Plastic Basket Strainer, Bag Filter or Y Strainer Filtering Device upstream to Avoid the Paddle Wheel from being damaged by the solids or fibers – max 10% Particle Size – Not to Exceed .5mm Cross Section or Length. Please do not flush the pipe after the Flow Meter is installed with Compressed Air this may damage the ceramic shaft and will Void Warranty.
2F4i-n05d64Qu©aIclointyPrPocreossdCuoncttroslsOLtdn. line at:
Valuetesters.com
info@valuetesters.com10
Truflo® — TKS | TK3S Series
In-Line Paddle Wheel Flow Meter Sensor
Warranty, Returns and Limitations
Warranty
Icon Process Controls Ltd warrants to the original purchaser of its products that such products will be free from defects in material and workmanship under normal use and service in accordance with instructions furnished by Icon Process Controls Ltd for a period of one year from the date of sale of such products. Icon Process Controls Ltd obligation under this warranty is solely and exclusively limited to the repair or replacement, at Icon Process Controls Ltd option, of the products or components, which Icon Process Controls Ltd examination determines to its satisfaction to be defective in material or workmanship within the warranty period. Icon Process Controls Ltd must be notified pursuant to the instructions below of any claim under this warranty within thirty (30) days of any claimed lack of conformity of the product. Any product repaired under this warranty will be warranted only for the remainder of the original warranty period. Any product provided as a replacement under this warranty will be warranted for the one year from the date of replacement.
Returns
Products cannot be returned to Icon Process Controls Ltd without prior authorization. To return a product that is thought to be defective submit a customer return (MRA) request form and follow the instructions therein. All warranty and non-warranty product returns to Icon Process Controls Ltd must be shipped prepaid and insured. Icon Process Controls Ltd will not be responsible for any products lost or damaged in shipment.
Limitations
This warranty does not apply to products which: 1. are beyond the warranty period or are products for which the original purchaser does not follow the warranty procedures
outlined above; 2. have been subjected to electrical, mechanical or chemical damage due to improper, accidental or negligent use; 3. have been modified or altered; 4. anyone other than service personnel authorized by Icon Process Controls Ltd have attempted to repair; 5. have been involved in accidents or natural disasters; or 6. are damaged during return shipment to Icon Process Controls Ltd
Icon Process Controls Ltd reserves the right to unilaterally waive this warranty and dispose of any product returned to Icon Process Controls Ltd where: 1. there is evidence of a potentially hazardous material present with the product; 2. or the product has remained unclaimed at Icon Process Controls Ltd for more than 30 days after Icon Process Controls Ltd
has dutifully requested disposition.
This warranty contains the sole express warranty made by Icon Process Controls Ltd in connection with its products. ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY DISCLAIMED. The remedies of repair or replacement as stated above are the exclusive remedies for the breach of this warranty. IN NO EVENT SHALL Icon Process Controls Ltd BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING PERSONAL OR REAL PROPERTY OR FOR INJURY TO ANY PERSON. THIS WARRANTY CONSTITUTES THE FINAL, COMPLETE AND EXCLUSIVE STATEMENT OF WARRANTY TERMS AND NO PERSON IS AUTHORIZED TO MAKE ANY OTHER WARRANTIES OR REPRESENTATIONS ON BEHALF OF Icon Process Controls Ltd. This warranty will be interpreted pursuant to the laws of the province of Ontario, Canada.
If any portion of this warranty is held to be invalid or unenforceable for any reason, such finding will not invalidate any other provision of this warranty.
by
2F4i-n05d64Qu©aIclointyPrPocreossdCuoncttroslsOLtdn. line at:
Valuetesters.com
info@valuetesters.com11
Documents / Resources
![]() |
Truflo TK3S Series In Line Paddle Wheel Flow Meter Sensor [pdf] User Manual tks-15-pp-b-e, tks-40-p-e, TK3S Series In Line Paddle Wheel Flow Meter Sensor, TK3S Series, In Line Paddle Wheel Flow Meter Sensor, Paddle Wheel Flow Meter Sensor, Flow Meter Sensor, Meter Sensor, Sensor |