TECH KW-12m Input Card Instruction Manual
The KW-12m input card is a device that takes a part in the exchange of information between sensors and devices connected to the card and the Sinum Central device.
It is designed for mounting on a DIN rail. Communication with the Sinum central device is done by wire.
Control lights description
Power supply
Communication
1-4 – Two-state inputs status
Connectors description
- Registration button
- SBUS communication connector
- Two-state inputs connector (+24V)
- NTC sensor connector (1-8)
How to register the device in the sinum system
The device should be connected to the Sinum central device using the SBUS connector 2 , and then enter the address of the Sinum central device in the browser and log in to the device. In the main panel, click the Settings > Devices > SBUS devices > + > Add device. Then briefly press the registration button 1 on the device. After a properly completed registration process, on the screen will appear a window to define function of each two-state inputs (button or two-state input). Additionally, at the end of registration, the user can name the device and assign it to a specific room.
How to identify the device in the Sinum system
To identify the device in the Sinum Central, activate the Identification Mode in the Settings > Devices > SBUS Devices > + > Identification Mode tab and hold the registration button on the device for 3-4 seconds. The device used will be highlighted on the screen.
Technical data
Power supply: 24V DC ±10%
Max. power consumption: 1,5W
Operation temperature: 5°C ÷ 50°C
NTC Sensor thermal resistance: -30°C ÷ 50°C
Notes
TECH Controllers is not responsible for any damages resulting from improper use of the system. The manufacturer reserves the right to improve devices, update software and related documentation. The graphics are provided for illustration purposes only and may differ slightly from the actual look. The diagrams serve as examples. All changes are updated on an ongoing basis on the manufacturer’s website.
Before using the device for the first time, read the following regulations carefully. Not obeying these instructions may lead to personal injuries or controller damage. The device should be installed by a qualified person. It is not intended to be operated by children. It is a live electrical device. Make sure the device is disconnected from the mains before performing any activities involving the power supply (plugging cables, installing the device etc.). The device is not water resistant.
The product may not be disposed of to household waste containers.
The user is obliged to transfer their used equipment to a collection point where all electric and electronic components will be recycled.
EU Declaration of conformity
Tech Westernise II Sp. z o.o. , UL. BIA Avogadro 34, Wiener (34-122) Hereby, we declare under our sole responsibility that the: KW-12m is compliant with Directive:
- 2014/35/UE
- 2014/30/UE
- 2009/125/WE
- 2017/2102/UE
For compliance assessment, harmonised standards were used:
- PN-EN IEC 60730-2-9:2019-06
- PN-EN 60730-1:2016-10
- EN IEC 63000:2018 RoHS
Pawed Jurua Janus Master
Pressie firmly
The full text of the EU declaration of conformity and the user manual are available after scanning the QR code or at www.tech-controllers.com/manuals
tel: +48 33 875 93 80
www.tech-controllers.com
support.sinum@techsterowniki.pl
Documents / Resources
![]() |
TECH KW-12m Input Card [pdf] Instruction Manual KW-12m, KW-12m Input Card, KW-12m, Input Card, Card |