SG485-3
INTERFACE EXPANSION MODULE
USER MANUAL
SG485-3 Interface Expansion Module
SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD.
All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder.
Applications for the copyright holder’s written permission to reproduce any part of this publication should be addressed to Smartgen Technology at the address above.
Any reference to trademarked product names used within this publication is owned by their respective companies.
SmartGen Technology reserves the right to change the contents of this document without prior notice.
Table 1 Software Version
Date | Version | Note |
2021-06-08 | 1.0 | Original release. |
2021-07-19 | 1.1 | Update pictures in the manual. |
2021-11-06 | 1.2 | Update pictures in the manual. |
OVERVIEW
SG485-3 is the expansion module of the RS485 interface, which has 3 interfaces, namely the RS485 host interface, RS485 slave 1 interface, and RS485 slave 2 interfaces. It can convert 1# RS485 interface to 2# RS485 interface, providing convenience for customers to monitor and collect data via Modbus-RTU protocol.
PERFORMANCE AND CHARACTERISTICS
Its main characteristics are as follows:
─ With 32-bit ARM SCM, high hardware integration, and improved reliability;
─ DC(8~35)V continuous power supply;
─ 35mm guide rail installation method;
─ Modular design and pluggable connection terminals; compact structure with easy mounting.
SPECIFICATION
Table 2 Performance Parameters
Items | Contents |
Working Voltage | DC(8~35)V |
RS485 Interface | Baud rate: 9600bps, max. communication distance can reach 1,000m when a 120Ω shielded twisted pair line is applied. Stop bit: 1-bit’ Parity bit: None |
Case Dimension | 71.6mmx92.7mmx60.7mm (LxWxH) |
Working Temperature | (-40~+70)°C |
Working Humidity | (20~93)%RH |
Storage Temperature | (-40~+80)°C |
Protection Level | IP20 |
Weight | 0.14kg |
WIRING
Fig.1 Mask Diagram
Table 3 Indicators Description
No. | Indicator | Description |
1. | POWER | Power indicator, always on when powered on. |
2. | RS485 | RS485 HOST communication indicator flashes 100ms when sending or receiving data. |
3. | RS485(1) | RS485 SLAVE(1) communication indicator, flashes 100ms when sending or receiving data. |
4. | RS485(2) | RS485 SLAVE(2) communication indicator, flashes 100ms when sending or receiving data. |
Table 4 Wiring Terminals Description
No. | Function | Cable Size | Remark | |
1. | B- | 1.0mm2 | DC power negative. | |
2. | B+ | 1.0mm2 | DC power is positive. | |
3. |
RS485 HOST |
TR |
0.5mm2 |
RS485 host interface communicates with controller, TR can be shortly connected with A(+), which is equivalent to connecting 120Ω matching the resistor between A(+) and B(-). |
4. | A(+) | |||
5. | B(-) | |||
6. |
RS485 SLAVE(1) |
TR |
0.5mm2 |
RS485 slave interface communicates with PC monitoring interface, TR can be shortly connected with A(+), which is equivalent to connecting 120Ω the matching resistor between A(+) and B(-). |
7. | A(+) | |||
8. | B(-) | |||
9. |
RS485 SLAVE(2) |
B(-) |
0.5mm2 |
RS485 slave interface communicates with PC monitoring interface, TR can be shortly connected with A(+), which is equivalent to connecting 120Ω the matching resistor between A(+) and B(-). |
10. | A(+) | |||
11. | TR |
Table 5 Communication Address Setting
Communication Address Setting | ||||||||
Address | Host Address | Slave 1 Address | Slave 2 Address | |||||
Dial Switch No. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
The corresponding relation between dial switch combination and communication address |
00:1 | 000:1 | 000:1 | |||||
01:2 | 001:2 | 001:2 | ||||||
10:3 | 010:3 | 010:3 | ||||||
11:4 | 011:4 | 011:4 | ||||||
/ | 100:5 | 100:5 | ||||||
/ | 101:6 | 101:6 | ||||||
/ | 110:7 | 110:7 | ||||||
/ | 111:8 | 111:8 |
ELECTRICAL CONNECTION DIAGRAM
This module is applied for the expansion of the RS485 interface, which can convert 1# RS485 interface to 2# RS485 interface. Common connection examples are as follows:
OVERALL DIMENSION AND INSTALLATION
SmartGen — make your generator smart
SmartGen Technology Co., Ltd.
No.28 Jinsuo Road
Zhengzhou
Henan Province
P. R. China
Tel: +86-371-67988888/67981888/67992951 +86-371-67981000(overseas)
Fax: +86-371-67992952
Web: www.smartgen.com.cn/
www.smartgen.cn/
Email: sales@smartgen.cn