SIMARINE LogoSIMARINE SCQ25 SCQ50 Digital Shunt ModuleSCQ25 & SCQ50
USER MANUAL
V1.0

SCQ25,SCQ50 Digital Shunt Module

© 2025 SIMARINE
All rights reserved. No parts of this work may be reproduced in any form or by any means – graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems – without the written permission of the publisher.
Products that are referred to in this document may be either trademarks and/or registered trademarks of the respective owners. The publisher and the author make no claim to these trademarks.
While every precaution has been taken in the preparation of this document, the publisher and the author assume no responsibility for errors or omissions, or for damages resulting from the use of information contained in this document or from the use of programs and source code that may accompany it. In no event shall the publisher and the author be liable for any loss of profit or any other commercial damage caused or alleged to have been caused directly or indirectly by this document.

Introduction

SCQ digital shunt module is Simarine’s most versatile module. It can be used to measure voltage, current.
SCQ25 has 4x 25 A integrated shunts capable of measuring voltage up to 35 V DC and continuous current up to 25 A on each shunt.
SCQ50 has 4x 50 A integrated shunts capable of measuring voltage up to 35 V DC and continuous current up to 50 A on each shunt.

Safety

Electrical specialists with proper safety equipment should make installation of Simarine electronics. When working with batteries, you should wear protective clothing and eye protection.
CAUTION: Batteries contain acid, a corrosive, colorless liquid that will burn your eyes, skin, and clothing. Should the acid come in contact with eyes, skin or clothing, wash it immediately under fresh water for at least 15 minutes, and seek medical support immediately.
CAUTION: Do NOT connect anything to a damaged battery. It could heat up, catch fire or explode.
CAUTION: Lead-acid batteries can generate explosive gases during operation. Never smoke, allow flames or sparks near the battery. Make sure to keep sufficient ventilation around the battery.

Declaration of conformity

CE SYMBOL MANUFACTURER: SIMARINE d.o.o.
ADDRESS: Ulica škofa Maksimilijana Držecnika 6, SI-2000 Maribor, Slovenia, EU
Declares that the following product:
PRODUCT TYPE: SCQ25 & SCQ50
Is in conformity with the relevant European union harmonization legislation:
EMC Directive 2014/30/EU with the following harmonized standards:

  • EN- IEC 61000-6-1:2007 o EN-lEC 61000-6-2:2005/AC:2005
  • EN- IEC 61000-6-312007/Al:2011/AC:2012
  • EN 50498:2010 o lSC)7637-2:2016

RED DireCtive 2014/53/EU with the following standards:

  • CISPR 16-23:2010(EN 55016-2- 3:2010 and Amd Al:2010>
  • ETSI EN 301 489- 2 3 and ETSIEN 301 489-17V3.24
  • ETSI EN 300 628 V2 2 2,Clause 4 3110 and Clause 4.3111

Low Voltage Directive 2014/35/EU with the following harmonized standards:

  • EN lEC 62368-1:2020

Restriction of the use of certain hazardous substances RoHS 2011/65/EU and 2015/863/EU)with the following harmonized standards:

  • EN IEC 63000,2018

Vehicle Radiated Emissions&Immunity:

  • ECE RlO-6

Overview

SIMARINE SCQ25 SCQ50 Digital Shunt Module - OverviewA – 4x shunt input
B – 4x shunt output
C – 1x Alarm signal relay
D – 2x SiCOM port

Installation

5.1 Mounting
CAUTION: install the shunt module in a clean dry place, protected from accidental spilling of liquids.

  1. You can fix the module with the supplied screws using four holes on both sides of the module.
  2. Connect all cables

5.2 Cables
For the SiCOM connection use the supplied cable. If not possible, use the following table to determinate the right cable type.

Cable length Cable type
< 5m No limitations
>= 5m 2 x 2 x 0.25 mm2 Twister pair (recommended)

Note: Minimum power cable cross-section requirement at maximal temperature of insulation 70 °C (160 °F).

Connecting

For proper function of Simarine’s SCQ digital shunt it is necessary to take the following steps:

  1. Connect the SCQ to Simarine PICO via the SICOM port
  2. Connect consumers/generators minus or plus terminal through one SCQ shunt.

Each correctly connected shunt needs to be configured. This is done via PICO in an easy way. The configuration process is described in PICO’s manual.

  • PICO manual & other user manuals: https://simarine.net/support/

    CAUTION:
    After connecting the shunt, make sure that all the connections between cables and shunt are tight. Loose connections may cause sparks, heating and even a fire. It may also damage the shunt.

Technical specifications

SCQ25
Operating
Voltage range 6 – 35 V
Temperature range -20°C – 70°C (-4°F – 158°F)
Power consumption at 12V
Operating 2.5 mA
Current Measuring (per channel)
Range 0.01 – 25 A
Accuracy 1%
Resolution 0.01 A
Sampling rate 100 ms
Maximal current
Continuous 25 A
Peak current ( Cmin ) 35 A
Dimensions 183 x 91 x 34 mm
Current channels 4
Connectivity SiCOM
Alarm contact 1
SCQ50
Operating
Voltage range 6 – 35 V
Temperature range -20°C – 70°C (-4°F – 158°F)
Power consumption at 12V
Operating 2.5 mA
Current Measuring (per channel)
Range 0.01 – 50 A
Accuracy 1%
Resolution 0.01 A
Sampling rate 100 ms
Maximal current
Continuous 50 A
Peak current ( <1min ) 60 A
Dimensions 183 x 91 x 34 mm
Current channels 4
Connectivity SiCOM
Alarm contact 1

Safe Voyage.

SIMARINE LogoSIMARINE marine electronics
www.simarine.net
©2022 All rights reserved