Specifications

  • Size (HxWxD): 37x42x16 ±0.5 mm / 1.46×1.65×0.63 ±0.02 in
  • Weight: 28 g / 1 oz
  • Screw terminals max torque: 0.4 Nm / 3.5 lbin
  • Conductor cross section: 0.2 to 2.5 mm² / 24 to 14 AWG (solid, stranded, and bootlace ferrules)
  • Conductor stripped length: 6 to 7 mm / 0.24 to 0.28 in
  • Mounting: In-wall
  • Shell material: Plastic
  • Shell colour: Cyan
  • Ambient working temperature: -20°C to 40°C / -5°F to 105°F
  • Storage temperature: 10°C to 40 °C
  • Humidity: 30% to 70% RH
  • Max.x. altitude: 2000 m / 6562 ft
  • Power supply: 220-240 V~ 50 Hz (Shelly Bypass is required for the load at O1)
  • Shelly Bypass included: Yes
  • Power consumption: < 1.2 W
  • Neutral not needed: Yes (Shelly Bypass is required for the load at O1)
  • Min. load without neutral and without a Bypass: · Bypass is required for the load at O1, except for incandescent lights.
  • Max. switching voltage: 240 V~
  • Max. switching power:
    • 200 W through O1
    • 700 W through O2
  • Internal-temperature sensor: Yes

Wi-Fi

  • Protocol: 802.11 b/g/n
  • RF band: 2401 – 2495 МHz
  • Max. RF power: < 20 dBm
  • Range: Up to 30 m / 98 ft indoors and 50 m / 164 ft outdoors (Depends on local conditions)

Bluetooth

  • Protocol: 4.2
  • RF band: 2400 – 2483.5 MHz
  • Max. RF power: < 4 dBm
  • Range: Up to 10 m / 33 ft indoors and 30 m / 98 ft outdoors (Depends on local conditions)
  • CPU: ESP-Shelly-C38F
  • Clock frequency: 160 MHz
  • RAM: 512 KB
  • Flash: 8 MB
  • Schedules: 20
  • Webhooks (URL actions): 20 with 5 URLS per hook
  • Scripting: Yes
    MQTT: Yes

Product Usage Instructions

Wiring diagram
Legend
Shelly-2L-Gen3-Switching-Module-fig- (1)

Device terminals

  • O2: Load circuit output terminal 2
  • S2: Switch input terminal 2
  • L: Live (220-240 V~) terminal
  • O1: Load circuit output terminal 1
  • S1: Switch input terminal 1
  • Sx: Switch signal output terminal

Wires

  • L: Live wire (220-240V~)
  • N: Neutral wire

User and safety guide Shelly 2L Gen3
Two-channel smart switch for lighting control without Neutral

Safety information

  • For safe and proper use, read this guide nd any other documents accompanying this product.
  • Keep them for future reference. Failure to follow the installation procedures can lead to malfunction, danger to health and life, violation of law, and/or refusal of legal and commercial guarantees (if any).
  • Shelly Europe Ltd. is not responsible for any loss or damage in case of incorrect installation or improper operation of this device due to failure to follow the user and safety instructions in this guide.

This sign indicates safety information.

This sign indicates an important note.

  • WARNING! Risk of electric shock. Installation of the Device to the power grid must be performed carefully by a qualified electrician.
  •  WARNING! Before making any changes to the connections, ensure there is no voltage present at the Device terminals.
  • CAUTION! Connect the Device only in the way shown in these instructions. Any other method could cause damage and/or injury.
  •  CAUTION! Connect the Device only to a power grid and appliances that comply with all applicable regulations. A short circuit in the power grid or any appliance connected to the Device can cause fire, property damage, and electric shock.
  • CAUTION! The Device and the appliances connected to it must be secured by a ca-blcableection switch in accby98-1 (tripping characteristic B or C, max. 16 A rated current, min. 6 interrupting rating, energy limiting class 3).
  • WARNING! Before installing the Device, turn the circuit breakers off. Use a suitable test device to make sure there is no voltage on the wires you want to connect. When you are sure that there is no voltage, proceed to the installation.
  • CAUTION! Do not use the Device if it shows any sign of damage or defect.
  • CAUTION! The Device may be connected to and control only electric circuits and appliances that comply with the applicable standards and safety norms.
  • CAUTION! The Device is intended only for indoor use.
  • CAUTION! Keep the Device away from dirt and moisture.

Product description

  • Shelly 2L Gen3 (the Device) is a compact, dual-channel smart switch. A standout feature of this device is that it doesn’t require a Neutral wire to operate. However, it needs a Shelly Bypass connected in parallel to the load at the first channel.
  • Shelly 2l2len3 allows users to effortlessly control resistive, inductive, and capacitive loads through a mobile phone, tablet, PC, or integrated home automation system. It is convenient for managing lighting setups, electric heaters, transformers, fans, generators, etc.
  • The device can function standalone within a local Wi-Fi network or can be integrated with cloud home automation services. As long as the device remains connected to a Wi-Fi router and the Internet, users gain the flexibility to access, control, and monitor their configurations from virtually anywhere.
  • Designed with adaptability in mind, Shelly 2l 2ln3 is engineered to snugly fit within standard electrical wall boxes, be discreetly placed behind light switches, or in other areas where space might be a limiting factor. An added benefit is its embedded Web Interface, which allows users to fine-tune the Device settings with ease.
  • This device has MMaMatter-ready functionality that can be added with a firmware update.

Installation instructions

  • To connect the Device, we recommend using solid single-core wires or stranded wires with ferrules. The wires should have insulation with increased heat resistance, not less than PVC T105°C (221°F).
  • When connecting wires to the Device terminals, consider the specified conductor cross-section and stripped length. Do not connect multiple wires to a single terminal.
  1. Connect the first load (up to 1,2 A) to the O1 terminal of the Device and the Neutral wire as shown in the wiring diagram.
  2. Connect the Shelly Bypass, provided in the package, in parallel to the first load (mandatory except for incandescent lights).
  3. Connect the second load to the O2 terminal and the Neutral wire.
  4. Connect the first switch or button to the S1 and Sx terminals.
  5. Connect the second switch or button to the S2 and Sx terminals.
  6. Connect the Live wire to the L terminal.

Shelly Cloud inclusion

  • The Device can be monitored, controlled, and set up through our Shelly Cloud home auautomationervice. You can use the service through either our Android, iOSiosr Harmony OS mobile application or through any internet browser at https://control.shelly.cloud/.
  • If you choose to use the Device with the application and Shelly Cloud service, you can find instructions on how to connect the Device to the Cloud and control it from the Shelly app in the application guide: https://shelly.link/app-guide.
    Troubleshooting
  • In case you encounter problems with the installation or operation of the Device, check its knowledge base page:  https://shelly.link/2L_Gen3

Declaration of Conformity
Hereby, Shelly Europe Ltd. declares that the radio equipment type Shelly 22lGen3 complies with Directive 2014/53/EU, 2014/35/EU, 2014/30/EU, 2011/65/EU. The full text of the EU declaration of conformity is available at the following internet address:

Changes in contact information are published by the Manufacturer on the official website. All rights to the trademark Shelly® and other intellectual rights associated with this Device belong to Shelly Europe Ltd.

For the UK PSTI Act Statement of Compliance, scan the QR codeShelly-2L-Gen3-Switching-Module-fig- (2)

FAQs

How do I control the Shelly 2l Gen3?
The Shelly 2L Gen3 can be monitored, controlled, and set up through the Shelly Cloud home automation service. You can access this service via the Shelly Cloud mobile applications for Android, iOSiosr Harmony OS, or through any internet browser at https://control.shelly.cloud/.

Documents / Resources

Shelly 2L Gen3 Switching Module [pdf] User Guide
Shelly 2L Gen3, 2L Gen3 Switching Module, 2L Gen3, Switching Module, Module

References

Leave a comment

Your email address will not be published. Required fields are marked *