sellEton Logo

SL-7561 INDICATOR
USER’S MANUAL
Portable Static Weighing Indicator

sellEton Scales com SL 7561 Portable Static Weighing Indicator

www.selletonscales.com

SAFETY PRECAUTIONS

For safe operation of the weighing indicator, please follow these
instructions:

  • Calibration inspection and maintenance of the indicator are prohibited by non-professional staff
  • Please ensure that the indicator rests on a stable surface
  • The indicator is a piece of static sensitive equipment; Please cut off power during electrical connections
  •  Touching the internal components by hand is prohibited
  • DO NOT exceed the rated load limit of the unit
  • DO NOT step on the unit
  • DO NOT jump on the scale
  • DO NOT use this product if any of the components are cracked
  • DO NOT use for purposes other then weight taking
  • To avoid damaging the battery do not keep charger plugged in once battery is fully charged
  • Make sure the weight is not over the Max capacity as it could damage the load cell inside
  • Material that has a static electric charge could influence the weighing. Discharge the static electricity of the samples, if possible. Another solution to the problem is to wipe both sides of the pan and the top of the case with an anti-static agent

Please take anti-static prevention measures
Any accumulated charge on the body of the human operator should be discharged first before opening the protective container with ESDS devices inside. The discharge can be accomplished by:

  • Putting a hand on a grounded surface or, ideally, by wearing a grounded Anti-static Wrist Strap and an Anti-static Mat

PREPARATION & SET UP

  • Plug into a wall outlet to avoid interference with other wirings
  • Turn on the indicator while there is no load
  • We suggest to warm-up the indicator by powering on 5 minutes before use for accurate weighing
  • Calibration may be required before weighing when the platform is initially installed or moved from a location

FEATURES

  • Designed to work with static axle scales
  • Gross weighing and accumulative weighing modes
  • LCD display (size: 5.3in x 1.4in)
  • Tare, Zero, Print, Save, Check, and Delete functions
  • Kg and lb weighing units
  • Built-in needle printer
  • Different printing formats
  • 6v/4.5Ah Battery and 9v/1.2A adapter
  • Can connect to a secondary large display/scoreboard
  • Can connect with up to 4 weighing pads
  • Shows individual scale/pad percentage of the total weight
  • Manual and automatic printing modes
  • Date and time can be set easily
  • Can connect to a PC or printer for data logging
  • Wireless capability (optional)
  • Splash proof keyboard and display

TECHNICAL PARAMETERS

  • Sensitivity : 0.5μV/d
  • Input voltage: -30 to +30mV DC
  • Accuracy class : III
  • Initial zero range : ±10%Max
  • Manually zero range : ±2% Max
  • Zero Range : 100% Max
  • Zero Tracking : 0.5d/s
  • Excitation circuit : VDC,6 wire connection,Maximum connect 24 load cell of 350Ω
  • AC power: AC 100-250VAC,50/60HZ (use only the 9V adapter supplied)
  • Operation temperature : -10°C ~ +40°C
  • Operation humidity: ≤90%RH
  • Storage temperature : -10°C ~ +40°C

SPECIFICATIONS

FIGURE 1: INDICATOR MEASUREMENTS

sellEton Scales com SL 7561 Portable Static Weighing Indicator - SPECIFICATIONS

POWER SUPPLY

Battery
Your indicator comes with a rechargeable battery, please charge the internal battery fully before first time use. A 110 to 220V AC adapter should be provided with your indicator. Please use only the AC adapter provided to prevent damage to your indicator.

  • When you use the internal battery for the first time,you should charge the battery fully, to prevent low voltage resulted from self leakage of battery
  • If the battery is not used for long time, remove to avoid leakage
  • To keep the battery in best condition, fully discharge the battery every month by leaving the indicator on until the indicator powers off, and then recharge fully
  • sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 1 symbol will indicate the battery’s charge
  • sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 2 symbol indicates that the battery needs to be charged

SL-7561 DISPLAY

sellEton Scales com SL 7561 Portable Static Weighing Indicator - SL-7561 DISPLAY

DISPLAY AND KEY DESCRIPTION

ON/OFF Powers the Indicator On or Off if held for 2 seconds
SWITCH Switch the weight between the pad weight and the total weight
CHECK Check and read the saved weight data to print
KG/LB Shifts between weighing units (kg/lb)
TARE 1.  Zero’s the scale. Used when using a container to hold objects
2.  Clears the tare to see the gross weight
ZERO Zero’s the scale
STORE In accumulative weighing mode it accumulates the axle weight and prints the weight data
PRINT 1.  Print data
2.  Works with the switch button to enter the calibration menu
Total Shows you are in Accumulation mode
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 3 The scale is at zero
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 4 The scale is stable
Net Shows you are in Net weight mode (without tare)
Gross Shows you are in Gross weight mode (includes tare); default mode
Tare Shows you have tared the scale
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 5 Indicates the charge of the battery
lb The weight is shown in pounds
kg The weight is shown in kilograms
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 6 Shows the percentage of weight on the pad out of the total weight
LFW The weight of the Left front wheel
RFW The weight of the Right front wheel
LRW The weight of the Left rear wheel
RRW The weight of the Right rear wheel
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 7 Power
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 8 Back
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 9 Save and Exit
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 10 Arrow keys
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 11 Return/Enter

OPERATING INSTRUCTIONS

Power On

  • Turn on the power by pressing the power button for 2 seconds. Once on, the scale will flash the voltage and then begin to auto-check and count down from 0-9 sequentially before entering the weighing mode
    Note: Anything on the scale before powering on will automatically be tared out.

Zeroing

  • The zero function is used only when the scale is empty and is not at gross zero due to material build up
  • Pressing the ZERO key will reset your scale to 0
  • Depending on what your manual zero range parameter is set to, you can zero out any number within your set selection, after that you will receive an error and will need to tare out the weight

Unit Selection

  • To switch between measuring units (kg or lb) press the KG/LB key

Tare Function

  • The Tare function is used when you only wish to see the current change in weight, not the entire amount of weight that is on the scale
  • When the indicator is in normal gross mode pressing the TARE key will Tare the current weight on the scale and enter the net mode sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 3
  • To exit Tare mode press the TARE key again to enter gross mode

To use a pre-set tare weight

  • Press and hold the tare key for 2 seconds
  • Input the tare weight using the arrow keys
  • Press print key to confirm

Check

  • The check key is used check previously saved weights
  • In weighing mode, press CHECK key to show sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 12
  • ex. if there are 30 records saved it will display sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 13
  • If you wanted to check the 20th saved weight you would input sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 14 and press PRINT to check the 20th record
  • The display will show sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 15. Choose “1” and press PRINT
  • The screen will flash the date, time, axle, tare weight and total weight one by one
  • Then the screen will show sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 16, enter “1” and press PRINT to print this record and go back to the Checking display sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 17
  • Press CHECK key again to exit and return to weighing mode

Switch

  • Switches the display between the total weight and each individual pad/scale weight
  • Individual pad display shows the percentage of that pads load, of the total weight

Print

  • If the weight on the scale is stable press the PRINT key to print the current weight

CALIBRATION PROCEDURE

  1. Turn on the scale by holding the ON/OFF sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 7 key. (If the scale does not turn on, plug in the ac adapter because the battery may be low.)
  2. Once on hold SWITCH sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 8 and PRINT sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 11 key to enter the indicator settings mode
  3. The display will show [sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 30] to indicate F1 settings mode, use the STORE UP key to change to sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 18
  4. Press the PRINT sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 11 key to select and enter the F2 settings mode
  5. The display will read sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 19
  6. Use the arrow keys to select which scale/pad you will be calibrating (1-4)
  7.  Press the PRINT sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 11 key to select and enter the next setting
  8. The display will read sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 20 use the STORE UP key to change to sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 21
  9. With nothing on the scale/pad press PRINT sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 11 to Zero Calibrate, the indicator will count down from sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 22 and enter the next parameter if no errors
  10. The display will show sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 23 use the STORE UP key to change to sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 24 press the PRINT sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 11 key to select and enter the calibration setting
  11. Use the arrow keys to enter the weight of the calibration weight you will be using (calibration weight must be at least 40% of the scale/pads capacity)
  12. Load the calibration weight on the pad/scale you are calibrating
  13. Once stable sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 4 press the PRINT sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 11 key to calibrate
  14. The indicator will count down from 9-0 and move on to the Save parameter sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 26
  15. Press STORE UP to change to sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 25, then save your calibration by pressing PRINT sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 11
  16. The indicator will display sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 27, Press CHECK sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 9 to exit the settings mode and go back to the weighing mode
  17. The display will show the value of the calibration weight on the scale
  18. Unload the scale; the display should read sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 28
  19. If no errors the scale has now been calibrated
  20. Repeat process until all pads/scales have been calibrated and saved

INDICATOR PARAMETER SETTINGS

This indicator has 5 different setting modes, [F 1], [F 2], [F 3], [F 4] & [F 5].
Each mode changes different indicator parameters.

To enter calibration/parameter settings, follow the procedure below:

  1. Press and hold the SWITCH and PRINT key at the same time for 2 seconds
  2. Navigate through the setting modes (F1 to F5) by using the arrow keys and return keys as labeled under each indicator button sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 29
  3. Press the PRINT sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 11 key to enter/edit the parameter setting
  4. Press the CHECK sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 9 key to save and exit settings at any time

F 1 Menu
Setting working mode, unit, decimal, graduation, and capacity

Step Parameter Display Settings/Options
Enter F1 Menu sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 30 sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 11
1 Mode sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 31 Choose how many weighing pad’s you’ll be using Options: 1/2/3/4
2 Unit sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 32 Choose default unit 0=kg 1=lb
3 Decimal setting sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 33 0 = no decimal 1 = #.#
2 = #.##
3 = #.###
4 = #.####
4 Graduation Setting (readability of the least significant digit) sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 34 Options: 1/2/4/10/20/50
Example with no decimal places (ie step 3=0) 1 = 1 lb
2 = 2 lb
5 = 5 lb
10 = 10 lb
20 = 20 lb
50 = 50 lb
5 Max Capacity sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 35 0 = do not change the max capacity
1= change the max capacity
ex. If step 2=0 and step 3=2
when changing max capacity   0100.00 = 100kg
Then press sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 9 to save your settings

F 2 Menu
Setting the Choosing a pad to calibrate, zero calibration, loading calibration, and saving

Step Parameter Display Settings/Options
Enter F2 Menu sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 36 sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 11
6 Pad Choice sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 37 Choose a pad/scale to calibrate Options: 1/2/3/4
7 Zero Calibration sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 38 0 = do not calibrate 1 = calibrate
Note: when 1 is selected the indicator will count down from 9-0 and move on to the next setting
8 Calibration sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 39 When ready for calibration, setting the span tells the indicator the weight you will be calibrating the scale with
0 = do not set the span
1 = set the span
Use the arrow keys to set your calibration weight and when done load your calibration weight to the scale Once stable sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 4 press sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 11 to calibrate
The indicator will count down from 9-0 and move on to the Saving parameter (Select 1 and press print to save your calibration settings)
9 Save sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 40 0 = do not save calibration 1 = save calibration

F 3 Menu

Step Parameter Display Settings/Options
Enter F3 Menu sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 41 sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 11
10 Axle Number sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 42 Set the number of axles (for use with accumulation mode)
11 Cargo Number sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 43 Set the cargo number
12 Printing Format sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 44 0 = No printing
1 = Normal printing format
2 = Accumulative printing format
* See page 13 for examples
13 Printing Method sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 45 0 = Manual
1 = Automatic
*Manual is recommended for the most precise results
14 Printing Coupon sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 46 Printing coupon numbers setting Options: 1/2/3
15 Baud Rate sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 47 Options: 1/2/3/4/5/6/7/8
0 = 600           1 = 1200        2 = 2400
3 = 4800         4 = 9600         5 = 19200
6 = 38400       7 = 57600       8 = 115200
16 Communication Settings sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 48 0 = Communication off
1 = Communication format 1 for PC
2 = Communication format 2 for second display (YAO HUA MODEL)
3 = Communication format 3 for second display (TOLEDO MODEL)
17 Automatic Power Off sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 49 00 = turn off auto power off
10 = power off automatically if no change within 10 min
30 = power off automatically if no change within 30 min
60 = power off automatically if no change within 60 min
18 Back Light sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 50 00 = Backlight on
10 = Backlight off after 10 seconds
19 Date Format sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 51 0 = year, month, day
1 = month, day , year
2 = day, month, year
20 Date sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 52 Set according to previous parameter
21 Time sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 53 Set using Military time

F 4 Menu 

Step Parameter Display Settings/Options
Enter F4 Menu sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 54 sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 11
22 Records sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 55 Set how many records/weights you want your indicator to store Max. the indicator can store is 2000 cps.
23 PCB sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 56 PCB version 1.0A
24 Software sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 57 Software version 1.00
25 LFW sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 58 Check the left front wheel ad code
26 RFW sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 59 Check the right front wheel ad code
27 LRW sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 60 Check the left back wheel ad code
28 RRW sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 61 Check the right back wheel ad code

F 5 Menu

Step Parameter Display Settings/Options
Enter F5 Menu sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 62 sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 11
29 Delete Weighing Records sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 63 0 = Do not delete the weighing record
1 = Delete the weighing record
30 Delete All sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 64 0 = Do not delete all the records
1 = Delete all the records

WEIGHING/PRINTING MODES

In the Parameters you can set to have your printer print automatically or manually, we recommend setting to manual (F3 [PM – 0]) for best results.

Normal Weighing mode:

  • In the F3 menu set the Printing Format to “1”
  • In this mode you have the option of using 1-4 pads

sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 65

Example : There are 3 weighing pads connected to the indicator to weigh an airplane.

  1. The pads should connect with LFW,LRW,RRW interfaces
  2. Parameter settings:
    F1 Working Mode setting: “3”
    F3 Printing Format setting: “1”sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 66
  3. Drive the plane on the pads. You can press the “SWITCH” key to switch between displaying the total weight, and the weight of each pad, shown with the percentage of that pads load of the total weight
  • If [PM – 1] Printing and Saving will be done automatically once the load is stable
  • If [PM – 0] Press the “PRINT” key to print results

Accumulative weighing mode: 

  • In the F3 menu set the printing format to “2”
  • In this mode you have the option of using 2 or 4 pads
  • The Print mode must be set to manual to function correctly
  • Drive axle on weighing pads
  • Press the “STORE” key to accumulate the axle’s weight and print the axle’s data
  • Repeat steps until all axles have been weighed
  • Then press the “PRINT” key to accumulate weights and print the total

sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 67

Example: There are 2 weighing pads connected to the indicator to weigh a truck with three axles.

  1. The pads should connect with LFW, RFW interfaces
  2. Parameter settings:
    F1 Working Mode setting: “2”
    F3 Printing Format setting: “2”
    F3 Printing Mode setting: “0”
    F3 Axle Number setting: “3”sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 68
  3. Measure spacing between tire sets in an axle and place weighing pads accordingly
  4. Drive the first axle of the truck on the weighing pads. When stable press the “STORE” key to begin accumulation by storing the weight data and printing the first axle’s results
  5. Drive the second axle of the truck on the weighing pads and when stable press the “STORE” key to accumulate and store the second weight data and print the second axle’s results
  6. Drive the third axle of the truck on the weighing pads and when stable press the “STORE” key to accumulate and store the third weight data and print the third axle’s results
  7. Then press the “PRINT” key to accumulate all three axle weights and print the total weight of the truck

sellEton Scales com SL 7561 Portable Static Weighing Indicator - Fig 1

PRINT FORMAT

Normal Printing Format

Single pad:
WEIGHTING REPORT
————————
NO. : 0575
Date: 2013-11-02
Time: 09:59:04
Vehicle:
Cargo:34
LFW: 429.0kg
—————-
Gross: 429.0kg
Operator:
Double pads:
WEIGHTING REPORT
————————
NO. : 0575
Date: 2013-11-02
Time: 09:59:04
Vehicle:
Cargo:34
LFW:429.0kg
RFW:413.5kg
Axle1:842.5kg
—————-
Gross: 842.5kg
Operator:
Three pads:
WEIGHTING REPORT
————————
NO. : 0575
Date: 2013-11-02
Time: 09:59:04
Vehicle:
Cargo:34
FW: 429.0kg
LRW: 319.0kg
RRW: 293.0kg
Axle2: 612.0kg
—————-
Gross: 1041.0kg
Operator:
Four pads:
WEIGHTING REPORT
————————
NO. : 0575
Date: 2013-11-02
Time: 09:59:04
Vehicle:
Cargo:34
LFW: 429.0kg
RFW: 413.5kg
Axle1: 842.5kg
LRW: 319.0kg
RRW: 293.0kg
Axle2: 612.0kg
——————Gross:
1454.5kg
Operator:

Accumulative Printing Format

Double pads:(Double axles)
WEIGHTING REPORT
——————————
NO. : 0594
Date: 2013-11-02
Time: 11:10:41
Vehicle:
Cargo:34
LW: 420.5kg
RW: 419.5kg
Axle01: 840.0kg
LW: 309.5kg
RW: 297.0kg
Axle02: 607.0kg
——————————
Gross: 1447.0kg
TOperator:
Four pads:(Four axles)
WEIGHTING REPORT
——————————
NO. : 0594
Date: 2013-11-02
Time: 11:10:41
Vehicle:
Cargo:34
LFW: 420.5kg
RFW: 419.5kg
Axle01: 840.0kg
LRW: 309.5kg
RRW: 297.0kg
Axle02: 607.0kg
LFW: 420.5kg
RFW: 419.5kg
Axle03: 840.0kg
LRW: 309.5kg
RRW: 297.0kg
Axle04: 607.0kg
—————————–Gross:
2894.0kg
Operator:

CONNECTORS

Connecting load cells to the indicator

  • SL-7561 can connect with 4 weighing pads or 24 pcs of load cells of 350Ω at most

QUICK DISCONNECT AS SHOWN BELOW:

sellEton Scales com SL 7561 Portable Static Weighing Indicator - CONNECTORS

The number of weighing pads and load cells corresponds to the weighing modes. If the pads or load cells are not connected properly the indicator will not function properly.
Please use the following table to connect your pads correctly.

INNER TERMINAL BLOCK CONNECTION DIAGRAM

Weighing Pad # Load Cell Connection Weighing Mode
1 LFW [Mode 1] Setting “1”
2 LFW, RFW [Mode 2] Setting “2”
3 LFW, LRW, RRW [Mode 3] Setting “3”
4 LFW, RFW, LRW, RRW [Mode 4] Setting “4”

DB9 Connection (9 pin Serial Connector)

sellEton Scales com SL 7561 Portable Static Weighing Indicator - pin Serial Connector

Pin function and definition are bellow:

DB9 Pin Definition Function
2 TXT Transmit Data
3 RXD Receive Data
5 GND Ground Interface

COMMUNICATION SETTINGS

Format 1 [CP – 1]
Workable with a PC
RS232COM serial interface can receive simple ASCII command.
RS232 parameter:9600Bit/S Baud rate,8 digits,no check point,1 stop.

sellEton Scales com SL 7561 Portable Static Weighing Indicator - Format

S1: weight status, ST=standstill, US=not standstill, OL=overload
S2: weight mode, GS=gross mode, NT=net mode
S3: weight of positive and negative, “+” or “-”
S4: “kg” or “lb”
Data: weight value, including decimal point
CR: carriage return
LF: line feed

Format 2 [CP – 2]
Workable with second display from Yaohua, Baud rate 600.
Format 3 [CP – 3]
Workable with second display from Toledo, Baud rate 1200.

PRINTER

sellEton Scales com SL 7561 Portable Static Weighing Indicator - PRINTER

To Remove lid:
Remove lid by pressing on the lower corner tabs and squeezing while pulling outwards
To Replace Ink:
Remove lid, then squeeze and pull forward on the pull tabs to pull printer forward from indicator. Next hold ink cartridge on both sides and pull straight down. To replace, feed paper through the new ink cartridge, then align the small holes located on the left side of the ink cartridge with the gears located under the left pull tab. Push cartridge upwards into place and push printer backwards into the indicator and replace lid.
To Replace Paper:
Remove lid, then squeeze and pull forward on the pull tabs to pull printer forward from indicator. Carefully remove ink cartridge. If the paper roll is not empty use the feed button to empty the roll. Once roll is empty squeeze both sides of the roll holder and pull  forward. Remove old roll from the roll holder and replace with a new paper roll. Squeeze both sides of the roll holder and replace back into the printer. Feed paper into the paper slot while holding the feed button. Then feed paper into the ink cartridge. Push  cartridge upwards into place and push printer backwards into the indicator and replace lid.

TROUBLESHOOTING

Error Codes 

Error Reason Solution
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 69 1. Overload
2. Wrong connection with load cell
3. Load cell has quality problem
1. Reduce the weight
2. Check load cell connection
3. Inspect load cell; Check the input/output
4. See Q&A section
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 70 1. Calibration is no good
2. Wrong connection with load cell
3. Load cell has quality problem
1. Make sure scale is level
2. Check load cell connection
3. Check load cell input and output resistance
4. See Q&A section
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 71 During calibration, weight is not used or the weight is above the max. capacity Use correct weight within the defined range
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 72 During calibration, the weight is below the minimum required weight The calibration weight minimum is 10% of the max. capacity set in C04.
Recommended to use 60%-80% of max. capacity if possible
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 73 During calibration, the input signal is negative 1. Check all wire connections
2. Check load cell
3. Recalibrate
4. PCB replacement needed if steps 1-3 fail
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 74 During calibration signal is unstable After the platform is stable, start calibration
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 75 EEPROM Error Change PCB
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 76 Exceed Zero Range See Q&A section
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 77 Scale was not stable when Zeroed Wait for the scale to stabilize before zeroing
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 78 Zero function can not be used in Tare mode Go back to gross weighing, by pressing Tare then you can Zero
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 79 Out of the zero range Move the extra load
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 80 Scale wasn’t stable when Tared Tare once the load is stable
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 81 Tared without a load Add your load, then tare
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 82 Out of tare range Decrease the tare weight
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 83 The record you are trying to check does not exist Assure the record you are trying to check exists
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 84 Printing format wrong in accumulative weighing mode Set Printing format to setting “2”
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 85 Working mode wrong in accumulative weighing mode Set Working mode setting to either “2 or 4”
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 86 You are weighing over max. capacity or you tried to print while the scale was unstable Reduce weight on the scale Print after scale has stabilized
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 87 Display Error, Printing with the indicator in accumulative weighing mode Print the total weight after accumulating the weight of axles
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 88 Printing error in normal Weighing mode Wait for the load to be stable, then print
sellEton Scales com SL 7561 Portable Static Weighing Indicator - Icon 89 Printing format wrong in normal weighing mode Set Printing format to Setting “1”

CONTACT US
Please e-mail info@selletonscales.com for any sales related questions or
call 844-735-5386
Don’t forget to visit our website at:
www.selletonscales.com

Documents / Resources

sellEton Scales com SL-7561 Portable Static Weighing Indicator [pdf] User Manual
SL-7561, SL-7561 Portable Static Weighing Indicator, Portable Static Weighing Indicator, Static Weighing Indicator, Weighing Indicator, Indicator

References

Leave a comment

Your email address will not be published. Required fields are marked *