Access Control
User Manual
INTRODUCTION
The keypad is a dual-entry multi-function access control with integrated keypad and card reader. It is designed and manufactured to perform in a wide range of indoor, outdoor and harsh environments.
The keypad supports up to 1100 users in multiple access configurations (Card, PIN, or Card + PIN). Its built-in card reader supports 125KHz EM/13.56MHz Mifare frequency cards.
Both of the two relays on board can operate in Pulse Mode (suitable for access control) or Toggle Mode (suitable for arming/disarming alarms, switching lights, machines….etc).
The keypad offers advanced programming features like: advanced relay programming and door bell. These features make it an ideal choice for door access not only for small shops and domestic households but also for commercial and industrial applications such as factories, warehouses, laboratories, banks and prisons.
Features
> Waterproof (IP66)
> Vandal resistant enclosure
> Backlit keypad
> Multi-color LED status display
> Two programmable relay output
> 1100 users (1096 Common users + 4 Panic users)
> Card type: 125KHz EM card/ 13.56MHz Mifare card
> Integrated alarm & buzzer output
> Low power consumption (55mA)
> Anti-tamper alarm
> Toggle mode to hold door or gate open
> Relay 2 supports external door bell
>12-28V AC/DC power input
Specifications :
User Capacity Zone 1 Zone 2 | 1100 Cards/PINS 1000 (998 common users + 2 panic users) 100 (98 common users + 2 panic users) |
Operating Voltage Idle Current Active Current | 12-28V AC/DC 55mA 80mA |
Proximity Card Reader Radio Technology Read Range | EM/Mifare (Optional) 125KHz EM/13.56MHz Mifare Card 3-6cm |
Wiring Connections | Electric Lock, Exit Button, DOTL, External Alarm, Door Bell |
Relay
Adjustable Relay Output Time Adjustable Alarm Output Time Lock Output Load Alarm Output Load |
Two (NO, NC, COM)
0-99 Seconds (5 seconds default) |
Environment Operating Temperature Operating Humidity |
Meets IP66 -40°C-60°C, or -40°F-140°F 10%— 90% Non-Condensing |
Physical Surface Finish Dimensions Unit Weight Shipping Weight |
Zinc-Alloy Enclosure Powder Coat L117 x W76 x H25mm (Wide) L130 x W56 x H23mm (Slim) 600g (Wide)/ 500g (Slim) 700g (Wide)/ 650g (Slim) |
Carton Inventory

INSTALLATION
> Remove the back cover from the unit
> Drill 2 holes(A,C) on the wall for the screws and one hole for the cable
> Knock the supplied rubber bungs to the screw holes(A,C)
> Fix the back cover firmly on the wall with 4 flat head screws
> Thread the cable through the cable hole(B)
> Attach the unit to the back cover
Wiring
Connection Diagram
Connect thenegaliv pole o thelock (o NG s for Fall safelock
Gonnect hanegatie polaof thelock o NO I o Falkscure ook
Door Bell Connect: the Zone 2, it can be used to operate the door bell when no need to operate a second door. The wiring is connecting the door bell to NO2 and COM2. Press #, the keypad will send out a switching signal to the door bell, as long as you press the” #”, the door bell will continuous operate, it will stop until you release the “#”
FUNCTION DESCRIPTION
Relay operation (Pulse mode and Toggle mode)
Both of the two relays on board can operate in Pulse Mode (suitable for access control) or Toggle Mode (suitable for arming/disarming alarms, switching lights, machines….etc)
Every time a valid tag/card read or PIN input in Pulse Mode, the relay will operate, for the pre-set relay pulse time.
Every time a valid tag/card read or PIN input in Toggle Mode, the relay changes state, which will not turn back until read card or input PIN again.
Master Card
There are two pre-programmed Master Cards, Zone1 Master Card is for faster adding/deleting user cards for zone 1, Zone 2 Master Card is for faster adding/deleting user cards for zone 2.
Anti-tamper Alarm
The Keypad uses a LDR (light dependent resistor) as an Anti-tamper alarm. If the keypad is removed from the cover then the tamper alarm will operate.
PROGRAMMING
Configure the Keypad
Change the configure settings according to your application (optional). Multiple configuration settings can be changed at one time: enter program mode, change desired settings, then exit program mode.
Set Master Code
The 6 digits Master Code is used to prevent unauthorized access to the system. To interface with the Keypad, the manager will need a Master Code (factory default: 123456). We highly recommend immediate update and recording of your Master Code.
SET ACCESS CONFIGURATION
> Card or PIN (Default): The User must present a valid Card to the keypad or enter their PIN code followed by the # key, in order to be granted access.
> Card + PIN: The User must first present a valid Card to the keypad and then enter their PIN code followed by the #key, in order to be granted access.
Relay Setting (Pulse mode, Toggle mode)
Door Alarm, Audible and Visual Response, Door Bell Settings
Door Open Detection
Door Open Too Long (DOTL) warning. When used with an optional magnetic contact o builin magnetic contact of the lock, i the door is ‘opened normall, but not closed afer 1 minute, the Inside buzzer il beep automatically o remind people to close the door and continue for 1 minute before swiching off automaticaly.
Door Forced Open warning. When used with an optional magnelic contact or buitin magnetic contact o the lock, i the door i forced open, the nside| buzzer and alarm output wil both operate.
OTHERS
Using Master Cards
Reset to Factory Default:
This will reset the keypad to the factory default but all card/PIN information will still be retained. This will also require reprogramming of the Master Cards.
NOTE: This is useful if the original Master Cards have been lost.
- Power off the keypad
- Press * and hold the button while power is restored to the keypad.
- Release the button and wait until the amber LED shines.
- Present any 125KHz EM/13.56MHz Mifare card or Master Card (provided) to the keypad, this card is now the Zone 1 Master Card.
- Present any 125KHz EM / 13.56MHz Mifare card or Master Card (provided) to the keypad, this card is now the Zone 2 Master Card.
When the red LED begins to blink, the keypad has been successfully reset.
Erase all Users
This will delete ALL User data of Zone1 or Zone 2 or Both.
- Enter Program Mode by press: *(Master Code) #.
- Press 30000 # (for Zone 1)
Or
2. Press 90000 # (for Zone 2) - Exit:*
All configuration data is retained.
Sound and Light Indication
FCC STATEMENT :
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
Documents / Resources
![]() |
Secukey Technology SK4 Access Control [pdf] User Manual D-5198A-KPX, 2AJWY-D-5198A-KPX, 2AJWYD5198AKPX, SK4 Access Control, SK4, Access Control, Control |