Sebury-LOGO

Sebury Q3 Standalone Access Controller

Sebury-Q3-Standalone-Access-Controller-PRODUCT

Specifications

  • Supports EM or PIN for single door control
  • Can drive electric lock, connect exit button, door magnetic detection, and door bell button
  • Can be used as a Reader working with a controller
  • 500 user capacity with each user having one card and a 4-6 digits PIN

Frequently Asked Questions

Q: Can every user change their password without the master?

A: Yes, every user can change their password without requiring the master’s assistance.

Q: What is the capacity of users this product supports?

A: The product supports up to 500 users, each having one card and a 4-6 digits PIN.

Product Introduction, Features & Technical Parameters

Introduction

Q3 support EM or PIN to control single door, can drive electric lock, connect exit button, door magnetic detection and door bell button, also can be used as
Reader working with controller. 500 pcs user capacity and each user owns one card and a 4-6 digits PIN.

Features

  • Use RFID to open door, fashion, security and reliability.
  • Can be used as controller and reader, freely switch, easily operate.
  • Clear and beautiful luminous keypad, convenient for user to enter password & open door.
  • With door bell button, convenient for visitor.
  • 500 pcs user capacity, suit for office, villa and household use etc.
  • Wiring is very simple; can be done by users without professional knowledge; can be connected with various electric lock and no need to change external wiring.
  • Every user can change the password without master.
  • Password is 4-6 digits, more security.
  • Multiple output format of pressing key, can work with types of controller.
  • Anti-vandal, door magnetic detection alarm function.

Technical Parameters:

  • Input voltage: DC12~24V
  • Idle current: 20mA
  • Max reading distance: 5-8cm
  • Frequency: 125KHz
  • Door bell output load: ≤10mA
  • Lock output load: ≤3A
  • Output format of card No.: Wiegand26
  • Output format of pressing one key: 4bit, 8bit
  • Dimension: 130mm×75mm×17mm
  • Operating temperature: -40~60° C
  • Operating humidity: 0~95% (non-condensing)

Installation And Wiring Diagram

  1. Following the figure and draw the installation and cable hole on the wall.
    Use φ6mm drill bit for drilling two installation hole and φ10mm drill bit for drilling cable hole.
  2. Insert rubber bungs to installation hole, fix the back shell of controller on the wall.
  3. Pull controller’s cable through the cable hole, connecting the wire needed according to wiring diagram.( use electrical tape to cover the wire not used)
  4. Plug 10P connection wire to PCB board of controller; fasten the front cover on the back shell with an anti-vandal screw.
    Sebury-Q3-Standalone-Access-Controller-FIG-1Sebury-Q3-Standalone-Access-Controller-FIG-2 Sebury-Q3-Standalone-Access-Controller-FIG-3 Sebury-Q3-Standalone-Access-Controller-FIG-4

Master Setting

Note that all the following programming should be under master programming mode.

Master Setting

When master’s PIN is wrong and the time is over 5s before you enter PIN again, it will return to standby mode. After enter right master’s PIN, it will also return to standby mode if there is no valid operation in 30 seconds. Press “#” to confirm the input number, return to previous menu by press “*”, the indicator light will indicate the operation mode.

To enter the master programming mode

Red Red Flash Functions Remark
  6-8 digits master’s PIN # To enter the programming mode Factory default 888888

Access Controller Setting

Red Flash Orange Functions Remark
0 6-8 digits new PIN # repeat 6~8 digits new PIN # To change the master’s PIN  
 

1

Read card  

 

To add card users

 

 

Rotate Operation

1-500(ID), #, Read card
8 or 10 digits card number #
1-500(ID),#,8 or 10 digits card number #
1-500(ID), #,4-6 digits PIN, # To add PIN users
 

2

Read card Delete one card Rotate Operation
8 or 10 digits card number, #
1-500(ID),# Delete one user
2 0000, # (Note: This is a dangerous option, so use with care)  

Delete All users

 
 

3

0, # Entry by Card only  

Factory default 2

1, # Entry by Card and PIN together
2, # Entry by either card or PIN
4 0, # To set door relay time 50mS Factory default 5s
1-99, # To set door relay time 1-99S
5 0, # Connect to A type of lock Factory default 1
1, # Connect to B type of lock

Reader Setting

Red Flash Orange Flash Orange Functions Remark
 

 

7

1 0, # Reader mode Factory default 1
1, # Access controller mode
 

3

0, # Virtual card No. Factory default 1
1, # 4Bit of pressing one key
2, # 8Bit of pressing one key

Note

  1. 8 digits card No., for example 118, 32319, some cards have no the first 3 digits 118, remain 32319, in this case, add card user by reading card but not enter card number.
    10 digits card No., for example 0007765567, some cards have no the first 3 digits 000, remain 7765567, in this case, you need enter 000 before 7765567 to add this card user.
  2. A PIN 1234 will be generated automatically when we add a card user; it is only for changing new PIN, not to open door.
  3. After a card is added, you can continue to add other cards or PIN without exiting current setting mode and start over.
  4. A type of lock refers to those lock that normally under standby status ,there is no current for lock, when there is current the door will open, such as electrified lock, electric strike.
  5. B type of lock refers to those lock that normally under standby status, there is current for lock, when there is no current the door will open, such as electromagnetic lock, electric drop bolt.

User Operation

  1. Swiping Card to open door:
    Sebury-Q3-Standalone-Access-Controller-FIG-5 door will be opened.
  2. Swiping Card+PIN to open door:
    Sebury-Q3-Standalone-Access-Controller-FIG-6 door will be opened.
  3. Card or PIN to open door:
    Sebury-Q3-Standalone-Access-Controller-FIG-7 door will be opened.
  4. Change the user’s PIN
    Sebury-Q3-Standalone-Access-Controller-FIG-8
    Remarks: PIN users have to get the ID No. and initial PIN from master. Card
    users have to swipe card when change the PIN first time.
  5. Door bell:
    Press door bell button on Q3, the connected external door bell will ring.
    Note: External door bell should be low current (≤10mA).

Alarm Function

  1. Anti-vandal alarm
    If anti-vandal alarm function is on and when device is opened illegally, controller will sound alarm.
  2. Door Magnetic detection alarm
    If the door is connected with magnetic contact, and is opened illegally or by force, controller will sound alarm.
  3. Remove the alarm
    Swipe valid card or enter master’s PIN can remove alarm. If there is no any operation the alarm will stop automatically after 1 minute.

Reset To Factory Default

Power off, press “*” and power on, the LED turns into ORANGE in 1s, and then release the button “*” after you hear “ Beep Beep”, And then you hear “Bee-eep”, the LED turns into Red means reset to Factory Default successfully. But it won’t delete all user information.

Sound And Light Indication

Operation Status Color of LED Buzzer
Stand by Red  
Pressing keypad   Beep
Swipe card Green Bee-eep
Unlocking Green Bee-eep
Successful Green Bee-eep
Fail   Beep Beep Beep
Entering PIN RED flash slow  
Swiping card under way of swiping card+PIN RED flash slow  
First menu of setting RED flash slow  
Second menu of setting Orange flash slow  
Setting Orange  
Alarming Red flash quick Alarm sound

Card Reader Mode Wiring Diagram As Below

Sebury-Q3-Standalone-Access-Controller-FIG-9

 

  • To use the card reader function, first set the machine for card reader mode, it has following functions:
  • When LED level is low, LED light will turn into Green, after 30 seconds or LED level rising, LED light will return to normal.
  • When BZ level is low, the Buzzer will beep, after 30 seconds or BZ level rising, the Buzzer will return to normal.
  • Both card number and pressing keypad output in Wiegand format, output data is transmitted by the Low Level of D0 & D1 wire:
    • D0: Low level means 0, green wire
    • D1: Low level means 1, white wire
  • The Pulse width for low level is 40uS; and the time interval is 2mS.
    Sebury-Q3-Standalone-Access-Controller-FIG-10
  • Output format of card number is Wiegand 26.
  • Output format of pressing keypad can be set 3 formats:
  • Format 0: virtual card No. , namely enter 4-6 digits PIN, #, output a 10bits card number in Wiegand 26 format. For example, enter a password 999999, the output card number is 0000999999, could be displayed as a 10bits decimal card number on a equipment which support to display it.
  • Format 1: 4 bit of pressing one key, which is pressing every single key, output a 4bit data, the corresponding relationship is:
    • 1 (0001) , 2 (0010) , 3 (0011)
    • 4 (0100), 5 (0101 ) , 6 (0110)
    • 7 (0111) , 8 (1000) , 9 (1001)
    • * (1010) , 0 (0000) , # (1011)
  • Format 2: 8 bit of pressing one key, which is pressing every single key, output a 8bit data, the corresponding relationship is:
    • 1 (11100001) , 2 (11010010) , 3 (11000011)
    • 4 (10110100) , 5 (10100101) , 6 (10010110)
    • 7 (10000111) , 8 (01111000) , 9 (01101001)
    • * (01011010) , 0 (11110000) , # (01001011)

Packing List

Name Model No Qty. Remark
Access controller Q3 1  
10P connection wire   1  
User manual Q3 1  
Rubber Bung   2 Used for fixing installation
Self-tapping Screw Φ4mm×25mm 2 Used for fixing installation
Special Screwdriver   1 Special tool of security screw

Documents / Resources

Sebury Q3 Standalone Access Controller [pdf] Instruction Manual
Q3 Standalone Access Controller, Q3, Standalone Access Controller, Access Controller, Controller

References