SBI logoLINER OFFSET ADAPTER AC01214  
INSTALLATION INSTRUCTIONS SBI AC01214 Liner Offset AdapterInstruction Manual

AC01214 Liner Offset Adapter

 warning This manual is available for free download on the manufacturer’s web site. It is a copyrighted document. Re-sale is strictly prohibited. The manufacturer may update this  manual from time to time and cannot be responsible for problems, injuries, or damages arising out of the use of information contained in any manual obtained from  unauthorized sources.

IMPORTANT:
Read through all instructions before beginning your installation. It is important that you carefully follow the installation instructions. Failure to install this product as  described in these instructions will void the manufacturer’s warranty and may cause fire, injury or even death. Keep these instructions for future reference.
Each vent system must be properly designed and installed to enable optimal performance and safety. Refer to the appliance manufacturer’s instructions to determine the  requirements and limitations limitations with respect to installation and use of the appliance. It is the responsibility of the installer to contact local building and fire officials  concerning any installation restrictions and/or inspection requirements that may apply when not specified in the appliance instruction manual.
It is not recommended to add any other offset when installing this adapter.
Doing so could influence the draft significantly and reduce the efficiency of your appliance. The chimney system should have as little restriction as possible. Once the  installation is completed, your chimney should have a minimum height of 15 feet (4.5 m). Note that in order to ensure optimal draft, it is possible that you need to add some  extra lengths to your chimney.

 warning IMPORTANT: The use of a firescreen is strongly discouraged when an offset is installed on the chimney system of an appliance. The restriction that the offset could cause increases the risk of smoke emanating from the door. For all other restrictions related to the installation of a firescreen, please consult the instruction sheet supplied with this option

Required accessories to complete your installation (not included):

1x Flexible chimney liner adapter (Provided by the flexible liner’s manufacturer.
Unnecessary with rigid chimney liner)
SBI AC01214 Liner Offset Adapter - fig
1x Flexible stainless steel chimney liner  OR
Rigid stainless steel chimney liner  (Variable length)
SBI AC01214 Liner Offset Adapter - fig 1
3x Self-tapping screws SBI AC01214 Liner Offset Adapter - fig 2

Tools required for installation:SBI AC01214 Liner Offset Adapter - fig 3

Dimensions of the assembled liner offset adapter

SBI AC01214 Liner Offset Adapter - fig 4

  1. If you use a flexible liner, please install a suitable adapter to it.SBI AC01214 Liner Offset Adapter - fig 5
  2. Drop the liner along the chimney flue.SBI AC01214 Liner Offset Adapter - fig 6
  3. Connect the liner on the liner offset adapter using a flat screwdriver. To do so, secure the liner offset adapter using the clamping ring on the liner offset adapter.SBI AC01214 Liner Offset Adapter - fig 7
  4. Install the insert into the masonry hearth and connect the liner offset adapter to the unit.SBI AC01214 Liner Offset Adapter - fig 8Note: you may cut the excess of material in front of the liner offset adapter (as shown besides) if it interferes with installation of the faceplate.
  5. Secure the liner offset adapter to the unit using 3 self-tapping screws (not included).SBI AC01214 Liner Offset Adapter - fig 9

CLEANING THE LINER OFFSET ADAPTER:

WARNING
It is important to keep this adapter free from any build up or restriction.
Failure in doing so may result in improper draft, smoke spillage, creosote build up and risk of a chimney fire. Inspect and clean chimney frequently Under certain conditions  of use, creosote buildup may occur rapidly.
Once you have your chimney swept, you should clean the inside of the liner offset adapter following these steps:

  1. Remove any decorative element on the front of your heating appliance, such as faceplate, to access the liner offset adapter.
  2. Remove the screws on each side of the cover using a Robertson screwdriver.SBI AC01214 Liner Offset Adapter - fig 10
  3. Remove the cover and proceed to clean the inside of the adapter.SBI AC01214 Liner Offset Adapter - fig 11
  4. Once cleaning is completed, close the cover and reinstall the 2 screws on each side of the cover using the Robertson screwdriver.
  5. Finally, install all decorative elements removed in step 1.

STOVE BUILDER INTERNATIONAL INC.
250, de Copenhague, Saint-Augustin-de-Desmaures
(Quebec), Canada G3A 2H3
Tel : 418-878-3040
Fax : 418-878-3001

Documents / Resources

SBI AC01214 Liner Offset Adapter [pdf] Instruction Manual
AC01214 Liner Offset Adapter, AC01214, Liner Offset Adapter, Offset Adapter, Adapter
SBI AC01214 Liner Offset Adapter [pdf] Instruction Manual
AC01214 Liner Offset Adapter, AC01214, AC01214 Offset Adapter, Liner Offset Adapter, Offset Adapter, Liner Adapter, Adapter
SBi AC01214 Liner Offset Adapter [pdf] Installation Guide
AC01214, 46267A, AC01214 Liner Offset Adapter, Liner Offset Adapter, Offset Adapter, Adapter

References

Leave a comment

Your email address will not be published. Required fields are marked *