Resin Curing Machine
G3
AB + UV Dual-Cure
INS1664
Warranty Information
Dear customer, thank you for purchasing RESINERS products. We will provide warranty services for your order:
Warranty Instructions:
From the date of purchase, quality issues will be covered by warranty with a valid order invoice. If you encounter any problems with the product after receipt or during use, please contact us for assistance.
Warm Reminder:
All products we sell are brand new and in good condition, please confirm the quantity of the product and parts after receiving the product. If you received a problematic product, please contact us for assistance and we will address your problems efficiently.
WARNING:
- This device is suitable for children aged 8 and older, as well as individuals with physical, sensory, or intellectual limitations, as long as they use it safely under supervision or guidance and understand the associated hazards.
- Children should not play with this device. Children should not clean or perform user maintenance without supervision.
- The device should only be operated at the voltage indicated on the label.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance. - If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- Please do not look directly at the open UV lamp with your naked eyes, nor shine the UV lamp into others’ eyes.
Instruction: https://resiners.com/pages/user-manual
Customer Service
Email: support@resiners.com
Please scan the QR code to view the instruction video or go to:
https://bit.ly/44nvV5r
Product Structure
- Air Hole
- Operation Panel
- Function Identification
- Time/Temperature Display
- Handle
- Top Cover
- Base
- Silicone Mat
Form 1: Base with opening facing upward
Form 2: Base with opening facing downward
Name | Icon | Explain |
Power/Function Button | ![]() |
Touch button. Press and hold to power on, press and hold to power off. When the device is turned on, click to switch the function mode. |
Time/Temperature Switching Button | ![]() |
Touch button. When the time is displayed, click to switch to temperature display. When it is displayed as temperature, click to switch the time display. Default display time. |
Time/Temperature Minus Button | ![]() |
Touch button. Click the button to reduce the time or temperature. |
Time/Temperature Plus Button | ![]() |
Touch button. Click the button to increase the time or temperature. |
Flat Mold Mode | ![]() |
Suitable for flat molds. For example, coaster molds, jewelry molds, bookmark molds, etc. The recommended thickness of the mold is ≤1.5 inches (3.81cm). |
Tall Mold Mode | ![]() |
|
UV Light Mode | ![]() |
Used for curing UV resin. It is recommended to first cure the front side, then flip the mold over and cure the back side for optimal curing results. |
Time Display | ![]() |
The flat mold and high mold modes display hours and minutes, while the UV mode shows minutes and seconds. The time is displayed in real time in countdown mode. |
Temperature Display | ![]() |
Displaying 131F indicates that the set temperature at this time is 131°F, and displaying 55C indicates that the set temperature at this time is 55°C. Only the set temperature is displayed, not the real-time temperature. |
Temperature Unit Switching | ![]() |
Click ![]() ![]() ![]() |
Cool Mode | ![]() |
When “COOL” is displayed, it indicates that the cooling mode is currently active, lasting approximately 20 minutes. After heating is completed, both the Flat Mold and Tall Mold modes will automatically switch to cooling mode. |
Technology Specifications
Product Model | G3 |
Rated Voltage | 120V, 60Hz (US/CA/МХ) 230V, 50Hz (EU/UK/AU) Note: Different countries have different plugs. |
Rated Power | 200W |
Form 1: Base with opening facing upward
Usage scenario: Flat mold mode, Tall mold mode, UV light mode (Tall mold)
The height limit in Area A is 3 inches (7.62cm) and that in Area B is 5 inches (12.7cm).
The illustration shows the UV area. When in use, place the mold as centered as possible.
Form 2: Base with opening facing downward
Usage scenario: UV light mode (Flat mold), Flat mold mode
The height limit in Area A is 1 inches (2.54cm) and that in Area B is 2.6 inches (6.6cm).
The illustration shows the UV area. When in use, place the mold as centered as possible.
Usage Steps
1
1. Place the base on a level countertop (refer to the installation instructions for the base direction), and put a silicone pad on the base.
Form 1: Flat mold for epoxy resin
Form 1: Tall mold for epoxy resin
Form 1: Tall mold for UV resin
Form 2: Flat mold for epoxy resin
Form 2: Flat mold for UV resin
2
2. Place the mold on the silicone pad. Note that the areas for placing molds of different heights are not the same (refer to the instructions for the mold placement areas). Make the epoxy resin on the mold. Try not to move the base during the production process.
3
3. Close the lid. Plug in the power supply.
Form 1:
A: Flat mold for epoxy resin
B: Tall mold for epoxy resin
C: Tall mold and flat mold for epoxy resin
(Increase the curing time manually by 1 hour.)
4
4. Press and hold to power on. Press briefly to switch modes. Each mode comes with preset programs, while users can also customize temperature and time settings as needed.
Form 1:
Front
Back
D: Tall mold for UV resin
(Curing on both the front and back sides)
4
Form 2:
Front
Back
A: Flat mold for UV resin
(Curing on both the front and back sides)
B: Flat mold for epoxy resin
4
5
5. Curing completed. Remove the mold.(After heating ends, both Flat Mode and Tall Mode will automatically switch to COOL mode for approximately 20 minutes.)
6
6. Remove all cured resin residues from silicone matting surface.
7
7. How to Remove the Silicone Pad:
Form 1:
Use your fingers to pinch the raised edge and lift it out, or turn the base upside down to let it drop out.
Form 2:
Grip the edge with your fingers and pull it out.
Precautions
1. The molds need to be placed in accordance with the requirements of the mold area. |
2. During use, do not touch the air outlet with your hands to avoid burns. |
3. Do not cover the machine during operation. |
4. After use, unplug the power cord. |
5. After the thin mold is cured, it may become soft. It will be completely cured after standing for 30 to 60 minutes. |
Documents / Resources
![]() |