Quantek CP5-RX Versatile 3 in 1 Wiegand Proximity Reader and Keypad
Introduction
It is a waterproof Wiegand output keypad, with integrated proximity reader, that can be mounted either indoors or outdoors in harsh environments.
Four versions are available:
- EM version: read 125KHz EM card only
- EM+HID version: can read both 125KHz EM and HID cards
- Mifare version: can read 13.56MHz Mifare card
- EM+HID+Mifare version: can read 125KHz EM+ 125KHz HID+ 13.56MHz Mifare cards
Features
- Waterproof, conforms to IP66
- Programmable Wiegand output: 26-44, 56, 58 bits
- Programmable Keypad Transmission: 4bits, Bbits or virtual card number format
- Card type: EM card or EM+HID cards or Mifare card, or EM+HID+Mifare cards
- Reading range: 3~8cm
- External LED Control & External Buzzer Control
Specification
Version | EM | EM+HID | Mifare | EM+ HID+ Mifare | |
Frequency | 125KHz | 125KHz | 13.56MHz | 125KHz & 13.56MHz | |
Card Type | 125KHz EM Card | 12
I H a & |
13.56MHz Milare
Card |
125KHz EM&HID Cards &
13.56MHz Milare Card |
|
Read Range | 3-8cm | ||||
Standby Current | S35mA | ||||
Operating Voltage | 9~18VDC | ||||
Wiegand Output Format | Wiegand 26-44, 56, 58 bits output
(Factory default: 26bits for EM card, 34bits for Mifare card, Auto output for HID card) |
||||
Keypad Transmission
Format |
4bits (factory default)
8bits or virtual card number format can be set |
||||
Operating Temperature | -40°(-60°( | ||||
Operating Humidity | 0%RH-95%RH | ||||
Physical | ABS, Metal optional | ||||
Color | ABS: Black/Ivory | Metal: Silver | |||
Index of Protection | IP66 | ||||
Dimension | ABS: L122 x W50 x D21 mm | Metal: L148 x W56 x D22.5 mm | |||
Net Weight | ABS: 155g | Metal: 450g | |||
Shipment Weight | ABS:210g | Metal:500g |
Installation
- Drill 2 holes (A, C) on the wall for the screws and one hole (B) for the cable
- Knock the rubber bungs to the holes (A, C)
- Fix the back cover on the wall with 2 screws
- Thread the cable through the cable hole (B)
- Attach the unit to the back cover
Wiring
Connection Diagram
Programming
Change the configure settings according to your application (optional). Multiple configuration settings can be changed at one time: enter program mode, change desired settings, then exit program mode.
Set M aster Code
The 4-6 digits Master Code is used to prevent unauthorized access to the system. To interface with the keypad reader, the manager will need a Master Code (factory default code: 1 2 3 456), we highly recommend immediately updating it and recording the New Master Code.
Note:
When entering program mode, please press* for 5 seconds, and then press Master Code #.
Programming Step | Keystroke Combination |
1. Enter Program Mode | * (Master Code)# |
2. Update Master Code | O (New Master Code)#
( Repeat New Master Code)# |
3. Exit |
Packing List
Name |
Quantity |
Keypad Reader | 1 |
Manual | 1 |
Wall Fixing Plugs | 2 |
Self Tapping Screws | 2 |
Set Wiegand output format for EM Card
Set Wiegand output format for HID Card
Programming Step | Keystroke Combination |
1. Enter Program Mode | * (Master Code)# |
2. Format Setting | 2(0)#
(Auto output, factory default) 2 (26-37) # |
3. Exit |
Set Wiegand output format for Mifare Card
Programming Step | Keystroke Combination |
1. Enter Program Mode | * (Master Code)# |
2. Format Setting | 3 (0) # (Auto output)
3 (26-44, 56, 58) # (Factory default is 34bits) |
3. Exit |
Set PIN output format
The keypad reader can be set to 4 bits (factory default), 8 bits, or virtual card number format.
Programming Step | Keystroke Combination |
1. Enter Program Mode | * (Master Code)# |
2. Format Setting Virtual Card Number | 4 (0)# |
4Bits | 4 (4)# |
BBits | 4 (8)# |
3. Exit |
Set Audible and Visual Response
Programming Step | Keystroke Combination |
1. Enter Program Mode | * (Master Code)# |
2. LED Always ON | 5 (1) # (Factory default) |
LED Always OFF | 5(2)# |
OR
2. Enable Sound |
5 (3) # (Factory default) |
Disable Sound | 5(4)# |
OR | |
Keypad Backlit Always | 5 (5) # (Factory default) |
ON | |
Keypad Backlit | 5(6)# |
Automatic OFF | |
Automatic OFF after 20 | |
seconds, it will go ON by | |
pressing any key (this key | |
isn’t taken into consideration) | |
3. Exit |
Reset to Factory Default:
There are two methods to reset the device to factory default.
Method 1:
(Master Code)# 5(0) #
Method 2
(This way is suitable for users who forget the Master Code):
Power off, connect the Yellow cable and GND cable, and then power on, hold it for 5 seconds, there will be a long beep, which means reset to factory default successfully.
Data Signal
The below table shows the waveform of pulse width time (the duration of a pulse) and pulse interval time (the time between pulses) of the Wiegand data output from the readers. (Example 1010)
Keypad Transmission Format
The default keypad transmission format is 4 bits, 8 bits or virtual card number format can be set.
Virtual Card Number
The reader will transmit the PIN data when it receives the last key(#) after the PIN code
Example: PIN code: 999999 Press 999999 #, then the output format will be: 0000999999
4 bits
The reader will transmit the PIN data after every key is pressed:
- 1 (0001),2(0010),3(0011)
- 4 (0100), 5 (0101 ), 6 (0110)
- 7 (0111), 8 (1000),9 (1001)
- * (1010), 0 (0000), # (1011)
- 4 (0100), 5 (0101 ), 6 (0110)
- 7 (0111), 8 (1000),9 (1001)
- * (1010), 0 (0000), # (1011)
8 bits
The reader will transmit the PIN data after every key is pressed:
- 1 (1110 0001), 2 (1101 0010), 3 (1100 0011)
- 4 (1011 0100), 5 (1010 0101 ), 6 (1001 0110)
- 7 (1000 0111 ), 8( 0111 1000),9 (0110 1001)
- * (0101 1010), 0 (1111 0000), #(0100 1011)