Quantek CP-611LSR-V2.0 Laser Photocell Sensor
Product Usage Instructions
Installation:
- Fix the rain shield to the outside walls first.
- Ensure the device is perpendicular to the beam when fixing the beam base plate.
- Pass a four-core cable through the grommet at the bottom of the device.
- Connect the two power terminals and two isolated relay contacts according to your setup (N/O or N/C).
Range Calibration:
- Set the DIP switches or use the learning method to calibrate the range threshold.
- To self-learn a threshold range:
- Set all DIP switches to OFF.
- Place a target 200mm from the desired range.
- Power up the device and wait for the beep.
- Cross the beam 5 times at 0.5m from the sensor within 4 seconds.
- Adjust the target if necessary until the green light flashes rapidly.
- When a long beep sounds, the threshold is set.
Operation and Maintenance:
- Check the operation by moving the target 200mm closer after calibration.
- Avoid waving 5 times in front of the sensor on power-up to prevent resetting.
- For heavy rain or fog conditions, limit the range setting to 4 meters for optimal detection.
- Clean the lens regularly to maintain proper functionality.
Additional Notes:
- The device can be used for activation or secondary safety purposes.
- For vehicle detection, consider using two devices spaced 2 meters apart and wired in series.
- The device does not differentiate between pedestrians and vehicles.
FAQs
Q: Can the device be used in heavy rain or fog?
A: In heavy rain or fog, it is recommended to limit the range setting to a maximum of 4 meters for optimal detection.
Q: How do I clean the lens of the device?
A: Use a clean, soft cloth to gently wipe the lens of the device to maintain proper functionality.
PRODUCT OVERVIEW
Specification
- 7 fixed ranges plus full auto adjustment
- Maximum 8M
- 10-30V dc 10-24V ac
- Iq = 65mA, I detect = 28mA
- Dimensions 37 x 36 x 108mm
- Environmental rating – IP65
- 0.8A @ 30Vdc volt free N/O or N/C
- Operating temp -10° C to 60° C
Self Learning
The PCB has only one orientation and no angular adjustment. Be sure the surface is perpendicular to the beam. Fix the rain hood to the outside walls first, then fix the beam base plate. The device takes a four-core cable through a grommet in the bottom. Two terminals for power. Two for the isolated relay contact, set to N/O or N/C. The setting routine calibrates the range threshold, but 200mm less than the actual position ofthe target. The threshold can be set by DIP switch or learning. There are 7 presets 2 to 7.5M Self-learning: The setting procedure will not learn a target over 8m from the device. To learn a threshold range, set all DIPs to OFF, then ……….
- Place the target in the beam 200mm from the desired range.
- Power up, and wait for the beep. You now have 10secs
- Crossbeam 5 times at 0.5m from the sensor within 4 secs.
- There are 5 beeps, then the green light flashes rapidly
- Adjust the target if necessary.
- When the long beep sounds, the threshold is set
Check operation by moving the target 200mm closer. The setting will be kept on power outs, but do not wave 5 times on power up!
- A versatile device, can be used as activation or secondary safety.
switch settings
Preset dip switch settings
Heavy rain or fog may impair detection on longer range, for this reason, secondary safety applications should be set to a maximum of 4 meters range. The device does not distinguish between pedestrians and vehicles. 2 devices spaced 2 meters apart, wired in series, are advised for vehicle detection. Keep the lens clean.
CONTACT INFORMATION
- 11 Callywhite Business Park, Callywhite Lane, Dronfield S18 2XP
- +44(0)1246 417113
- sales@cproxltd.com
- www.quantek.co.uk
Documents / Resources
![]() |
Quantek CP-611LSR-V2.0 Laser Photocell Sensor [pdf] Instructions CP-611LSR-V2.0 Laser Photocell Sensor, CP-611LSR-V2.0, Laser Photocell Sensor, Photocell Sensor, Sensor |