Instalation Instruction
STEP 1 CHOOSE INSTALLATION LOCATION
Also great for:
Medicine cabinets Gun safes
Garage doors
Interior doors
SEE REVERSE FOR REMAINING STEPS
SPECIFICATIONS
Sensor: 2.25”H x 1”W x .5”D
Wireless signal range: 600ft (200M), open air.
Code outputs: tamper, tamper restore, alarm, alarm restore, low battery.
Transmitter frequency: SECURE 319.5 MHz (S-Line) Unique code ID Supervisory keep-alive interval: 70 minutes.
RF Peak field strength: typical 36000 up/m at 3m
Operating Temperature: -10C~50C
Relative Humidity: 5-95% Non-Condensing Storage Temperature: -40-80C
Replace battery with exact replacement every 5 years with 3V Lithium (x2).
- Panasonic CR2032
- Energizer CR2032
- Duracell DL2032
Note: Battery Safety
Observe polarity when inserting replacement batteries to avoid damaging the sensor.
Risk of fire, burns and explosion. Do not recharge, disassemble, burn or expose batteries to tern prelatures above loom (t212F)
Dispose of used batteries properly and in accordance with all local laws Keep batteries away from children.
This is a quick guide for experienced installers only. Refer to http://dealers.qolsys.com (login required)
STEP 2 REMOVE BATTERY TABS
STEP 3 APPLY ADHESIVE
STEP 4 LINE UP SENSOR & MAGNET
STEP 5 SECURE SENSOR & MAGNET
STEP 6 LEARN INTO PANEL
- Place your panel in “auto learn” mode
- Open and close the case to “tamper” the device
- Customize name and settings as desired and and touch “ADD”
Document#: IQS-MDW-SQG-05-23
Revision#: 5/11/23
Qualisys Product #:
QS1135-840 (white)
QS1136-840 (brown
Qualisys Inc. proprietary.
Reproduction without permission is not permitted.
FCC ID: 2AAJXQS-IQDWM
IC: 11205A-QSIQDWM
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Cet appareil est conforme avec Industry Canada exempts de licence standard RSS (s). Son function onement est souses aux deux conditions suivantes: (1) cat appareil ne doit pas pro voguer d’ interferences et (2) cat appareil doit accepter touted
interference, y comprise cells movant causer un mauves fonctionnement de l’ appareil.