Q-TRAN FXT-FLEXIBLE-BOXA Fully Encapsulated Flexible Fixture Instruction Manual
Q-TRAN FXT-FLEXIBLE-BOXA Fully Encapsulated Flexible Fixture

ATTENTION: Please read all instructions BEFORE installation

  • Product to be installed by a licensed electrician – Field modifications void warranty
  • Use only with Class 2 power supply unit — Compatible for use with Q-Tran power supplies
  • Surface mount or recessed in millwork
  • Not rated for walkover
  • Input Voltage: 24VDC
  • Diagrams for representation only and not to scale

METHODS OF INSTALLATION

METHODS OF INSTALLATION

Cove, Under & over cabinet:
Ideal for oce, retail, hospitality, education, laboratory, and residential.
METHODS OF INSTALLATION

Shelf:
Ideal for oce, retail, hospitality, education, laboratory, and residential.
METHODS OF INSTALLATION

Display cabinet:
Ideal for retail and hospitality
METHODS OF INSTALLATION

Signage:
Ideal for lobby, retail, hospitality,institutional, and transportation.
METHODS OF INSTALLATION

  • BOXA Profile
    Dimension
  • BOXA Profile (Seamless BW)
    Dimension
  • BOXA Profile (Seamless BRL)
    Dimension
  • BOXA Profile (Seamless RGB)
    Dimension
  • BOXA Profile (Seamless DW, DW-HE)
    Dimension
  • BOXA Profile (Seamless SW, SW-HE, SC)
    Dimension
  • BOXA Profile (Seamless RGBW)
    Dimension

COMPONENTS & HARDWARE

MOUNTING CLIP & MOUNTING CHANNEL

WSC
White snug clip
MOUNTING CLIP & MOUNTING CHANNEL

Included

  • #6 Flat Screw (one provided for each clip)

RLC
Rigid lock channel
MOUNTING CLIP & MOUNTING CHANNEL

Included

  • #6 Flat Screw (one provided for each clip)
  • 5/64 Allen key
  • #8-32 Set Screw

MC
Magnetic clip (Cove use only)
MOUNTING CLIP & MOUNTING CHANNEL

Included

  • #6 Flat Screw (one provided for each clip)

SGC
Side graze channel
MOUNTING CLIP & MOUNTING CHANNEL

Included

  • #6 Flat Screw (one provided for each clip)
SEAMLESS MOUNTING CLIP & SEAMLESS MOUNTING CHANNEL

PPS-2
PVC mounting clip
SEAMLESS MOUNTING CLIP & SEAMLESS MOUNTING CHANNEL

Included

  • #8 flat head screw (1 screw for every 16”)
  • Built in wireway

PPS-96
PVC channel
SEAMLESS MOUNTING CLIP & SEAMLESS MOUNTING CHANNEL

Included

  • #8 flat head screw
  • (1 screw for every 16”) Built in wireway

PPS-FT
PVC channel
SEAMLESS MOUNTING CLIP & SEAMLESS MOUNTING CHANNEL

Included

  • #8 flat head screw (1 screw for every 16”)
  • Built in wireway
  • Custom length
  SEAMLESS MOUNTING CLIP & SEAMLESS MOUNTING CHANNEL

PPS-LP-2
Low profile PVC mounting clip
  SEAMLESS MOUNTING CLIP & SEAMLESS MOUNTING CHANNEL

Included

  • #8 flat head screw (1 screw for every 16”)
  • No wireway

PPS-LP-96
Low profile PVC channel
  SEAMLESS MOUNTING CLIP & SEAMLESS MOUNTING CHANNEL

Included

  • #8 flat head screw (1 screw for every 16”)
  • No wireway

PPS-LP-FT
Low profile PVC channel
  SEAMLESS MOUNTING CLIP & SEAMLESS MOUNTING CHANNEL

Included

  • #8 flat head screw (1 screw for every 16”)
  • No wireway
  • Custom length
ACCESSORIES SOLD SEPARATELY

Q-ANGLE; sold in pairs
Q-ANGLE
ACCESSORIES SOLD SEPARATELY

Included

  • 4 SS #6×1.25” Flat head wood screws
  • 2 SS 4-40 Flat head clip screws
  • 2 SS 6-32 Fillister screws
NOTES:
MOUNTING CLIP SEAMLESS CLIP
  • White snug clip included with side graze channel
  • PPS-2 & PPS-LP-2 to join two fixtures together
  • 2 white snug clips provided per first 12”, 1 for each additional 12”.
    Other mounting styles incur additional charge, see price guide for details
  • PPS-96/FT & PPS-LP-96/FT to support the fixtures
  • PPS-FT is to be cut at Q-Tran to requested length

CONTINUOUS WIRING CONFIGURATION OPTIONS

CONTINUOUS WIRING CONFIGURATION OPTIONS
CONTINUOUS WIRING CONFIGURATION OPTIONS

Review wire method to ensure clean installation prior to mounting finished fixture.

NOTE: Additional wire methods include:
S1, S2, S3, S4, S5: Connector/Wire Input only
P1, P2, P3, P4, P5: Connector/Wire Input and Output

SURFACE MOUNTING METHOD

SURFACE PREPARATION

Temperature and environmental concerns:

  • Ideal application environment is 70-100ºF in 50% humidity or less.
  • Minimum application temperature: 50ºF
  • This temperature and humidity should be maintained for 72 hours after application for maximum holding force
    SURFACE PREPARATION

Using a 50/50 alcohol mix, thoroughly clean the backside of the fixture and the surface area where fixture will be installed. Allow 5 minutes to dry
SURFACE PREPARATION

For porous materials (Wood, Brick, Concrete etc.) apply two layers of paint or primer to the surface. This will help create a better bonding surface for these materials.This can be purchased from local hardware store.
SURFACE PREPARATION

MATERIALS SUGGESTED EPOXIES
Concrete, Stone, Cinderblock, Metal, and Brick Loctite Metal and Concrete Two-Part Epoxy
ABS, Fiberglass, Plastic, and PVC Loctite Plastic Two-Part Epoxy
Tile, Wood, Ceramic, Glass, or Metal Loctite Clear Two-Part Epoxy
All Purpose Strong Stik
WHITE SNUG CLIP
  • 2 clips provided per first 12”, 1 for each additional 12”

Determine the fixture(s) location and positioning on desired surface; evenly distribute clips. Make any necessary reference markings to indicate where each clip is to be secured in place. Recommended every 12”.
WHITE SNUG CLIP

  • Secure clips using the #6 flat head hardware provided
  • Ensure the screw head is flush with the clip’s base

NOTE: Flat head screw type is dependent on surface/application material Alternative flat head screws may be required. Refer to the surface material manufacturer for suggested screw type.
WHITE SNUG CLIP

Snap fixture onto clips.
WHITE SNUG CLIP

RIGID LOCK CHANNEL
  • 2 channels provided per first 12”, 1 for each additional 12”

Determine the fixture(s) location and positioning on desired surface; evenly distribute channels. Make any necessary reference markings to indicate where each channel is to be secured in place. Recommended every 12”.
RIGID LOCK CHANNEL

a. Push retainer clip onto fixture.
b. Push fixture with retainer clip into Rigid Lock Channel.
RIGID LOCK CHANNEL

Tighten set screw to lock fixture in channel for extra security.
RIGID LOCK CHANNEL

SIDE GRAZE CHANNE
  • 2 channels provided per first 12”, 1 for each additional 12”

Determine the fixture(s) location and positioning on desired surface; evenly distribute channels. Make any necessary reference markings to indicate where each channels is to be secured in place. Recommended every 12
SIDE GRAZE CHANNE

  • Secure clips using the #6 flat head hardware provided
  • Ensure the screw head is flush with the channel’s base.

NOTE: Flat head screw type is dependent on surface/application material Alternative flat head screws may be required. Refer to the surface material manufacturer for suggested screw type.
SIDE GRAZE CHANNE

Snap fixture onto channels.
SIDE GRAZE CHANNE

MAGNETIC CLIP
  • 2 clips provided per first 12”, 1 for each additional 12”

Determine the fixture(s) location and positioning on desired surface; evenly distribute clips. Make any necessary reference markings to indicate where each clip is to be secured in place. Recommended every 12”.
MAGNETIC CLIP

Attach clips to fixture matching magnet distances.
NOTE: Flat head screw type is dependent on surface/application material. Alternative flat head screws may be required. Refer to the surface material manufacturer for suggested screw type.
MAGNETIC CLIP

Align and snap fixture to magnetic rings.
MAGNETIC CLIP

SEAMLESS MOUNTING METHOD

PPS-2
  • Connects two seamless fixtures, with or without wire exit
  • 2” PVC mount channel
  • Built in wireway

Press both fixtures into PPS channel.
SEAMLESS MOUNTING METHOD

Snap fixture into mounted PPS channel when wire will exit into conduit do not install bracket.
SEAMLESS MOUNTING METHOD

Finished assembly for seamless feed mounting
SEAMLESS MOUNTING METHOD

PPS-LP-2
  • Connects two fixtures, with no wire exit
  • 2” low profile PVC mount channel

Snap in 2” channel.
SEAMLESS MOUNTING METHOD

Press fixture into mounted PPS channel.
SEAMLESS MOUNTING METHOD

Finished assembly for end feed mounting
SEAMLESS MOUNTING METHOD

PPS-96 / PPS-FT
  • Support two seamless fixtures, with or without wire exit
  • 96” (PPS-96) or custom length (PPS-FT)
  • Built in wirew

The PPS-BRACKET can be field cuttable and cut to whatever length your application requires. The PPS-BRACKET can be installed as a full length of 96”, multiple smaller pieces, or end to end for longer seamless runs.
Using pre-drilled pilot holes screw the #8 flat head screws to mount the PPS-BRACKET (1 screw every 16”).
NOTE: For drywall applications mount directly into a stud.
SEAMLESS MOUNTING METHOD

Using pre-drilled pilot holes, use the #8 flat head screws to mount the PPS-BRACKET.
SEAMLESS MOUNTING METHOD
SEAMLESS MOUNTING METHOD

To mount, pinch the upper half of the PPS-96 or PPS-FT while you pivot it around one side of the PPS-BRACKET and push-in until you hear it snap into place. The PPS-96 or PPS-FT flexes around the PPS-BRACKET to create a solid, and secure snap on connection.
SEAMLESS MOUNTING METHOD

PPS-LP-96 / PPS-LP-FT
  • Support two fixtures, without built-in wireway
  • 96” (PPS-LP-96) or custom length (PPS-LP-FT)low profile PVC mount channel

The PPS-BRACKET can be field cuttable and cut to whatever length your application requires. The PPS-BRACKET can be installed as a full length of 96”, multiple smaller pieces, or end to end for longer seamless runs.
Using pre-drilled pilot holes screw the #8 flat head screws to mount the PPS-BRACKET (1 screw every 16”).
NOTE: For drywall applications mount directly into a stud.
SEAMLESS MOUNTING METHOD

Using pre-drilled pilot holes, use the #8 flat head screws to mount the PPS-BRACKET.
SEAMLESS MOUNTING METHOD
SEAMLESS MOUNTING METHOD

To mount, pinch the upper half of the PPS-LP-96 or PPS-LP-FT while you pivot it around one side of the PPS-BRACKET and push-in until you hear it snap into place. The PPS-LP-96 or PPS-LP-FT flexes around the PPS-BRACKET to create a solid, and secure snap on connection.
SEAMLESS MOUNTING METHOD

© 2023 Q-Tran Inc. All rights reserved
155 Hill St. Milford, CT 06460
203-367-8777
sales@q-tran.com
www.q-tran.com

Q-TRAN logo

Documents / Resources

Q-TRAN FXT-FLEXIBLE-BOXA Fully Encapsulated Flexible Fixture [pdf] Instruction Manual
FXT-FLEXIBLE-BOXA Fully Encapsulated Flexible Fixture, FXT-FLEXIBLE-BOXA, Fully Encapsulated Flexible Fixture, Encapsulated Flexible Fixture, Flexible Fixture, Fixture

References

Leave a comment

Your email address will not be published. Required fields are marked *