Planet Technology ISW-500T-E 5-Port 10/100TX Ethernet Switch User Manual

ISW-500T-E 5-Port 10/100TX Ethernet Switch

Product Specifications

Product ISW-500T-E
Hardware Specifications
Copper Ports 5 x 10/100BASE-TX RJ45 auto-MDI/MDI-X ports, auto
negotiation
Switch Architecture Store-and-Forward
Switch Fabric 1Gbps (non-blocking)
Throughput (packet per second) 0.744Mpps@ 64 bytes
Address Table 1K entries
Shared Data Buffer Flow Control 448K bits
IEEE 802.3x pause frame for full-duplex Back pressure for half-duplex
ESD Protection 6KV DC
Enclosure IP40 metal case
Installation DIN-rail kit and wall-mount kit
Connector Removable 4-pin terminal block for power input Pin 1/2 for
Power 1, Pin 3/4 for Power 2 One for DC jack with central pole
2.1mm with Power 3
LED Indicator System: Power (Green) Per 10/100TX RJ45 Ports: 10/100 LNK/ACT
(Green)
Dimensions (W x D x H) 30.2 x 76.1 x 100 mm
Weight 266g
Power Requirements 12~55V DC (Support Polarity Protection) Redundant power
support

Hardware Introduction

Installation

To install the ISW-500T-E, follow these steps:

  1. Choose the appropriate location for mounting the switch.
  2. Use the DIN-rail kit or wall-mount kit to securely mount the
    switch.
  3. Connect the power input using the provided connector.
  4. Check the LED indicators to ensure proper power and connection
    status.

Configuration

To configure the ISW-500T-E:

  1. Access the online User’s Manual or Quick Installation Guide
    using the QR code provided.
  2. Follow the instructions in the manual to set up and customize
    the switch according to your network requirements.

Frequently Asked Questions (FAQ)

Q: What should I do if any components are missing or
damaged?

A: If any components are missing or damaged,
please contact your dealer immediately. Retain the original packing
material for possible return.

Q: How can I get technical support for the ISW-500T-E?

A: For technical support, visit PLANET’s online
FAQs at http://www.planet.com.tw/en/support/faq or contact
support@planet.com.tw.

“`

Compact Industrial 5-Port 10/100TX Ethernet Switch
ISW-500T-E User’s Manual

Table of Contents
1. Package Contents ……………………………………………………………………………… 3 2. Product Specifications ………………………………………………………………………… 4 3. Hardware Introduction ……………………………………………………………………….. 6
3.1 Three-View Diagram…………………………………………………………………….. 6 3.2 Front View ………………………………………………………………………………… 7 3.3 LED Definition: …………………………………………………………………………… 7 3.4 Top View …………………………………………………………………………………… 8 3.5 Wiring the Power Inputs ……………………………………………………………….. 8 3.6 Grounding the Device…………………………………………………………………… 9 4. Installation…………………………………………………………………………………….. 10 4.1 DIN-rail Mounting Installation……………………………………………………….. 10 4.2 Wall-mount Plate Mounting ………………………………………………………….. 11 5. Customer Support …………………………………………………………………………… 12

1. Package Contents
Thank you for purchasing PLANET Compact Industrial 5-port 10/100TX Ethernet Switch, ISW-500T-E. In the following section, the term “Industrial Ethernet Switch” means the ISW-500T-E.
Open the box of the Industrial Ethernet Switch and carefully unpack it. The box should contain the following items:

Industrial Ethernet Switch x 1

QR Code Sheet x 1

DIN-rail Kit

Wall-mount Kit

Let’s get started with your PLANET product ISW-500T-E

EN

Please scan the QR code to browse our online User’s Manual or Quick Installation Guide and follow the instructions to complete the setup.

Bitte scannen Sie den QR Code sie werden per Browser zur DE Bedienungsanleitung oder Schnellanleitung weiter geleitet. Folgen Sie den
Anweisungen um die Installation abzuschließen.

Veuillez scanner le code QR pour obtenir notre Notice d’Utilisation en FR ligne ou notre Guide d’Installation Rapide et suivez les instructions pour
compléter la configuration

Escanee el código QR para encontrar el Manual del Usuario en línea o

ES la Guía de Instalación Rápida y siga las instrucciones para completar la

configuración.

User’s Manual

IT Scansiona il codice QR per consultare online il Manuale utente o la Guida di installazione rapida e segui le istruzioni per completare la configurazione.

PT

Por favor, escaneie o QR code para navegar no Manual do Usuário ou Guia de Instalação Rápida. Siga as instruções para completar a configuração.

Zeskanuj kod QR, aby otworzy nasz internetow instrukcj obslugi PL lub instrukcj szybkiej instalacji. Postpuj zgodnie z instrukcjami, aby
zakoczy poprawn konfiguracj.

One word modify: QR-, RU –
,

RO

Te rugam sa scanezi codul QR, pentru a descarca User’s Manual sau Quick Installation Guide si a urmari instructiunile necesare in finalizarea instalarii

AR

Need more help?
PLANET online FAQs: http://www.planet.com.tw/en/support/faq Technical Support: support@planet.com.tw

Copyright © PLANET Technology Corp. 2025. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.

Part No. 2361-AH7130-000

RJ45 Dust Ca x 5

If any of these are missing or damaged, please contact your dealer immediately; if possible, retain the carton including the original packing material, and use them again to repack the product in case there is a need to return it to us for repair.
3

2. Product Specifications

Product

ISW-500T-E

Hardware Specifications

Copper Ports

5 x 10/100BASE-TX RJ45 auto-MDI/MDI-X ports, auto negotiation

Switch Architecture

Store-and-Forward

Switch Fabric

1Gbps (non-blocking)

Throughput (packet per second)

0.744Mpps@ 64 bytes

Address Table

1K entries

Shared Data Buffer Flow Control

448K bits
IEEE 802.3x pause frame for full-duplex Back pressure for half-duplex

ESD Protection

6KV DC

Enclosure

IP40 metal case

Installation

DIN-rail kit and wall-mount kit

Connector

Removable 4-pin terminal block for power input Pin 1/2 for Power 1, Pin 3/4 for Power 2 One for DC jack with central pole 2.1mm with Power 3

LED Indicator

System: Power (Green)
Per 10/100TX RJ45 Ports: 10/100 LNK/ACT (Green)

Dimensions (W x D x H) 30.2 x 76.1 x 100 mm

Weight

266g

Power Requirements

12~55V DC (Support Polarity Protection) Redundant power support

Power Consumption

Max. 1.1 watts/3.75 BTU (Ethernet full loading)

4

DIP Switch

Standard: In the normal mode, all interfaces can communicate with each other. Transmission distance is within 100 meters, and transmission rate is 10/100Mbps.
Extend: In the link extension mode, the data transmission distance for Port 1-4 can be extended to 250 meters, and transmission speed is 10Mbps.

Standards Conformance

Regulatory Compliance FCC Part 15 Class A, CE

Stability Testing

IEC60068-2-32 (free fall) IEC60068-2-27 (shock) IEC60068-2-6 (vibration)

Standards Compliance

IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX IEEE 802.3x flow control and back pressure IEEE 802.3az Energy Efficient Ethernet (EEE)

Environment

Operating Temperature -40 ~ 75 degrees C

Storage Temperature

-40 ~ 85 degrees C

Operating Humidity

10 ~ 90% (non-condensing)

Storage Humidity

5 ~ 95% (non-condensing)

5

3. Hardware Introduction
3.1 Three-View Diagram
The three-view diagram of the Industrial Ethernet Switch consists of five autosensing 10/100/BASE-TX RJ45 ports and one removable 4-pin terminal block. The LED indicators are also located on the front panel.

PWR1 PWR2

V1+

V2+

PWR3

DC Input: 12-55V , 0.15A max.

PWR 10/100

Standard Extend LNK ACT

1

2 3

4

5 ISW-500T-E

DIN-Rail Kit

Mounting Kit

Dimensions (W x D x H): 30.2 x 76.1 x 100 mm
Figure 1: ISW-500T-E Three-View Diagram

6

3.2 Front View

PWR 10/100

Standard Extend LNK ACT

1

2 3

4

5
ISW-500T-E
Figure 2: ISW-500T-E Front View

3.3 LED Definition: System

LED Color

Function

PWR Green Lights to indicate DC power input has power.

Per 10/100BASE-TX Port

LED Color

Function

10/100 LNK/ACT

Green

Lights Blinks

Indicating the port is running at 10/100Mbps and successfully established.
Indicating that the switch is actively sending or receiving data over that port.

7

3.4 Top View

DC Input: 12-55V , 0.15A max.

V1+

V2+

PWR1 PWR2

PWR3

Figure 3: ISW-500T Top View

3.5 Wiring the Power Inputs
The 4-contact terminal block connector on the top panel of Industrial Ethernet Switch is used for two DC redundant power inputs. Please follow the steps below to insert the power wire.
When performing any of the procedures like inserting the wires or tightening the wire-clamp screws, make sure the power is OFF to prevent from getting an electric shock.
1. Insert positive and negative DC power wires into contacts 1 and 2 for POWER 1, or contacts 3 and 4 for POWER 2.

DC Input: 12-55V , 0.15A max.

V1+

V2+

PWR1 PWR2

PWR3

8

2. Tighten the wire-clamp screws for preventing the wires from loosening.

12 Power 1 +-

34 Power 2 +-

1. The wire gauge for the terminal block should be in the range between 12 and 24 AWG.
2. The DC power input range is 12V ~ 55V DC

3.6 Grounding the Device
Users MUST complete grounding wired with the device; otherwise, a sudden lightning could cause fatal damage to the device. EMD (Lightning) DAMAGE IS NOT COVERED UNDER WARRANTY.
DC Input: 12-55V , 0.15A max.

V1+

V2+

PWR1 PWR2

PWR3

Earth Ground

9

4. Installation
This section describes the functionalities of the Industrial Ethernet Switch’s components and guides you to installing it on the DIN rail and wall. Please read this chapter completely before continuing.
This following pictures show the user how to install the device, and the device is not ISW-500T-E.
4.1 DIN-rail Mounting Installation
1
2
Place the bracket on the back of the device and with the given 3 screws, tighten them. Slide the device with the bracket mounted through the DIN-rail to finish the installation.
10

4.2 Wall-mount Plate Mounting
Place mounting plates on the back of the device, and tighten them with the given screws. Then put the device with the plates mounted on the wall, and screw them of finish the installation.
You must use the screws supplied with the wall-mounting brackets. Damage caused to the parts by using incorrect screws would invalidate your warranty.
11

5. Customer Support
Thank you for purchasing PLANET products. You can browse our online FAQ resource on PLANET web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team. PLANET online FAQs: https://www.planet.com.tw/en/support/faq.php Switch support team mail address: support@planet.com.tw
Copyright © PLANET Technology Corp. 2025. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners. 12

Trademarks
Copyright © PLANET Technology Corp. 2025. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.
Disclaimer
PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and makes no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness for a particular purpose. PLANET has made every effort to ensure that this User’s Manual is accurate; PLANET disclaims liability for any inaccuracies or omissions that may have occurred.
Information in this User’s Manual is subject to change without notice and does not represent a commitment on the part of PLANET. PLANET assumes no responsibility for any inaccuracies that may be contained in this User’s Manual. PLANET makes no commitment to update or keep current the information in this User’s Manual, and reserves the right to make improvements to this User’s Manual and or to the products described in this User’s Manual, at any time without notice.
If you find information in this manual that is incorrect, misleading, or incomplete, we would appreciate your comments and suggestions.
FCC Warning
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at whose own expense.
CE Mark Warning
This device is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference.
13

WEEE Warning
To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment, end users of electrical and electronic equipment should understand the meaning of the crossed-out wheeled bin symbol. Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately.
Energy Saving Note of the Device
This power required device does not support Standby mode operation. For energy savings, please remove the DC plug or slide the hardware-based Power Switch to the OFF position to disconnect the device from the power circuit. Without removing the DC plug from or switching off the device, the device will still consume power from the power source. In view of Saving the Energy and reducing the unnecessary power consumption, it is strongly suggested to power off or to remove the DC plug from the device if this device is not intended to be active.
14

Documents / Resources

Planet Technology ISW-500T-E 5-Port 10/100TX Ethernet Switch [pdf] User Manual
ISW-500T-E 5-Port 10-100TX Ethernet Switch, ISW-500T-E, 5-Port 10-100TX Ethernet Switch, 10-100TX Ethernet Switch, Ethernet Switch

References

Leave a comment