PILZ VT8-PITGB11 PIT gb with PIT Reader
Product Information
Specifications
- Product Name: PIT gb with PITreader
- Model Number: 1005249-EN-02
- Manufacturer: Pilz GmbH & Co. KG
- Storage: SD (Secure Digital) Card
Product Usage Instructions
Using the Documentation
Install and commission the product only after reading and understanding this document. Retain the document for future reference.
Definition of Symbols
DANGER! – This warning indicates a hazardous situation that poses an immediate threat of serious injury or death. Follow the preventive measures mentioned.
FAQ (Frequently Asked Questions):
Q: How do I troubleshoot issues with the PIT gb with] PITreader?
A: Refer to the Troubleshooting section in the manual (Page 27) for guidance on resolving common problems.
PIT gb with PITreader
Operating Manual-1005249-EN-02
- Control and signal devices
Preface
- This document is the original document.
- Where unavoidable, for reasons of readability, the masculine form has been selected when formulating this document. We do assure you that all persons are regarded without discrim-ination and on an equal basis.
- All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user’s internal purposes. Suggestions and comments for improving this documenta-tion will be gratefully received.
- Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®,
- SafetyEYE®, SafetyNET p®, the spirit of safety® are registered and protected trademarks of Pilz GmbH & Co. KG in some countries.
- SD means Secure Digital
Introduction
Validity of documentation
This documentation is valid for the product PIT gb with PITreader. It is valid until new docu-mentation is published.
This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
Using the documentation
This document is intended for instruction. Only install and commission the product if you have read and understood this document. The document should be retained for future ref-erence.
Definition of symbols
Information that is particularly important is identified as follows:
- DANGER!
This warning must be heeded! It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures that can be taken. - WARNING!
This warning must be heeded! It warns of a hazardous situation that could lead to serious injury and death and indicates preventive measures that can be taken. - CAUTION!
This refers to a hazard that can lead to a less serious or minor injury plus material damage, and also provides information on preventive measures that can be taken. - NOTICE
This describes a situation in which the product or devices could be damaged and also provides information on preventive measures that can be taken. It also highlights areas within the text that are of particular import-ance. - INFORMATION
This gives advice on applications and provides information on special features.
Overview
Product features
PIT gb with PITreader Key
- Housing with E-Stop pushbutton, 2 illuminated pushbuttons and PITreader Key
- PIT gb with PITreader Key is available in two versions:
- PIT gb RLLE y up ETH with connections on the E-STOP end
- PIT gb RLLE y down ETH with connections on the PITreader end
- PITreader Key: Authentication is via a transponder key (see Order reference: Transponder key [ 36])
- Connector design: a 12-pin M12 male connector and a 4-pin M12 female connector
- Slimline design
- Control elements finally wired and installed
- Coloured caps for pushbuttons, to mark the function
- Labelling option for individual marking of the control elements
- Can be installed in different directions (see Assembly positions [ 17])
PIT gb with PITreader Card
- Housing with E-STOP pushbutton, 2 illuminated pushbuttons and PITreader Card
- PIT gb with PITreader Card is available in two versions:
- PIT gb QLLE y up ETH with connections on the E-STOP end
- PIT gb QLLE y down ETH with connections on the PITreader end
- PITreader Card: Authentication is via transponder cards, transponder stickers and/or transponder keys (see Order reference: Transponder key [ 36])
- Connector design: a 12-pin M12 male connector and a 4-pin M12 female connector
- Slimline design
- Control elements finally wired and installed
- Coloured caps for pushbuttons, to mark the function
- Labelling option for individual marking of the control elements
- Can be installed in different directions (see Assembly positions [ 17])
Scope of supply
PIT gb with PITreader Key
- PIT gb RLLE y up ETH or PIT gb RLLE y down ETH
- 2 washers M5
- Coloured caps (set), assorted colours
PIT gb with PITreader Card
- PIT gb QLLE y up ETH or PIT gb QLLE y down ETH
- 2 washers M5
- Coloured caps (set), assorted colours
Safety
Intended use
The product PIT gb with PITreader is intended for use in safety circuits in accordance with IEC EN 60947-5-5, EN ISO 13850. Before using the product, a safety assessment of the overall system is needed in accordance with the Machinery Directive.
The PIT gb with PITreader is a system for authentication and authorisation on control systems. Authentication is via appropriate transponders.
The PIT gb with PITreader must be used in combination with a suitable evaluation device (see Connection to evaluation device [ 25]).
The following is deemed improper use in particular:
- Any component, technical or electrical modification to the product
- Use of the product outside the areas described in this manual
- Use of the product outside the technical details (see chapter entitled “Technical details [ 30]”).
NOTICE
EMC-compliant electrical installation
The product is designed for use in an industrial environment. The product may cause interference if installed in other environments. If installed in other environments, measures should be taken to comply with the applicable standards and directives for the respective installation site with regard to interference.
Foreseeable misuse
If using the PIT gb with PITreader under corrosive environmental conditions (cooling emulsions, surface treatment, gases, …):
Please contact Pilz.
Safety regulations
Additional documents that apply
You should also read and take note of the following document
Operating manual PITreader
You will need to be conversant with the information in this document to fully understand this operating manual.
Use of qualified personnel
The products may only be assembled, installed, programmed, commissioned, operated, de-commissioned and maintained by persons who are competent to do so.
A competent person is a qualified and knowledgeable person who, because of their training, experience and current professional activity, has the specialist knowledge required. In order to inspect, assess and handle products, devices, systems, plant and machinery, this person must be familiar with the state of the art and the applicable national, European and international laws, directives and standards.
It is the company’s responsibility only to employ personnel who
- Are familiar with the basic regulations concerning health and safety / accident prevention,
- Have read and understood the information provided in the section entitled Safety
- Have a good knowledge of the generic and specialist standards applicable to the specific application.
Warranty and liability
All claims to warranty and liability will be rendered invalid if
- The product was used contrary to the purpose for which it is intended,
- Damage can be attributed to not having followed the guidelines in the manual,
- Operating personnel are not suitably qualified,
- Any type of modification has been made (e.g. exchanging components on the PCB boards, soldering work etc.)
- The product was opened.
Disposal
When decommissioning, please comply with local regulations regarding the disposal of electronic devices, such as the Electrical and Electronic Equipment Act.
For your safety
WARNING
Risk of injury due to loss of the safety function.
Manipulation of the E-STOP pushbutton control element S4 may lead to serious injury and death.
- You should prevent the control element being manipulated with a spare control element.
- Only Pilz may exchange control elements.
- Before disposing of a defective PIT gb with PITreader: the PIT gb with PITreader must be safety decommissioned. To do this, all the data must be deleted from the product, see under “Reset PITreader to default setting [ 26]”.
INFORMATION
Do not remove the two protective caps on the connector until you are just about to connect the product.
Security
To secure plants, systems, machines and networks against cyberthreats it is necessary to implement (and continuously maintain) an overall industrial security concept that is state of the art.
Perform a risk assessment in accordance with VDI/VDE 2182 or IEC 62443-3-2 and plan the security measures with care. If necessary, seek advice from Pilz Customer Support.
Further information on Security can be found in the operating manual for the PITreader (1004806).
Function description
Product types
In order to control the functions of a whole plant or machine, the PIT gb with PITreader contains the following:
- One E-STOP pushbutton
- Two pushbuttons
- One PITreader
PIT gb with PITreader Key
- Rotatable mounting bracket
- M12 connector
- E-STOP pushbutton S4
- Pushbutton S3, illuminated
- Pushbutton S2, illuminated
- PITreader Key S1
- Individual labelling option (width: 35 mm, height: 13 mm)
M12 connector [2]
The two M12 connectors [2] used to connect the product are located either on the E-STOP end (PIT gb RLLE y up ETH) or on the PITreader end (PIT gb RLLE y down ETH).
- E-STOP pushbutton S4 [3] The E-STOP pushbutton S4 [3] is used to shut down plant and machine sections in order to reduce or avert imminent or existing hazards to persons and damage to machinery or materials.
- Pushbuttons S2, S3 [5, 4]
- Pushbuttons S2, S3 [5, 4] are used to switch a signal and for status display.
- Pushbuttons S2, S3 [5, 4] light up if the corresponding input is connected.
- Pushbutton S2 [5]
- With the pushbutton S2 [5] you can Reset the password of the PITreader to its default setting [ 26] during power-up.
- PITreader Key S1 [6] PITreader Key S1 [6] is used for authentication and authorization on control systems. Authentication is via transponder.
PIT gb with PITreader Card
- Rotatable mounting bracket
- M12 connector
- E-STOP pushbutton S4
- Pushbutton S3, illuminated
- Pushbutton S2, illuminated
- PITreader Card S1
- Individual labelling option (width: 35 mm, height: 13 mm)
- M12 connector [2] The two M12 connectors [2] used to connect the product are located either on the E-STOP end (PIT gb QLLE y up ETH) or on the PITreader end (PIT gb QLLE y down ETH).
- E-STOP pushbutton S4 [3] The E-STOP pushbutton S4 [3] is used to shut down plant and machine sections in order to reduce or avert imminent or existing hazards to persons and damage to machinery or materials.
- Pushbuttons S2, S3 [5, 4]
- Pushbuttons S2, S3 [5, 4] are used to switch a signal and for status display.
- Pushbuttons S2, S3 [5, 4] light up if the corresponding input is connected.
- Pushbutton S2 [5] With the pushbutton S2 [5] you can Reset the password of the PITreader to its default setting [ 26] during power-up.
- PITreader Card S1 [6] The PITreader Card S1 [6] is used for authentication and authorisation on control systems. Authentication is via transponder.
Block diagram
PITreader
The function of the PITreader authentication system is described in the operating manual for the PITreader (see Additional documents that apply [ 9]).
The PITreader cannot be connected to PIT m4SEU.
Coloured caps
The pushbuttons can be marked with coloured caps according to their function (see Attach coloured cap to pushbutton [ 19]).
Installation
Assembly positions
Potential installation positions of the mounting bracket on PIT gb with PITreader
The mounting brackets used to fasten the PIT gb with PITreader to the mounting surface can be rotated before installing the PIT gb with PITreader, see the following examples for the PIT gb with PITreader Key:
Potential installation positions of the PIT gb with PITreader
The potential installation positions of the PIT gb with PITreader are horizontal and vertical, see the following examples for the PIT gb with PITreader Key:
Installing the product
Note
- The PIT gb with PITreader must be installed on a solid surface (e.g. profile, panel).
- The PIT gb with PITreader must be situated so that it can easily be reached above the access level (e.g. base level, platform level).
The E-STOP pushbutton must be accessible at a height of between 0.6 m to 1.7 m above the access level. - The mounting surface must have a max. unevenness of 0.5 mm.
- The housing of the PIT gb with PITreader must make contact with the mounting surface over at least 5 mm on both ends (see figure).
Legend
- Mounting surface
- Mounting bracket
- Housing
- Use the following to fasten the PIT gb with PITreader:
- M5 screws
- M5 washers
Procedure
- Provide the mounting surface [1] with drill holes for fastening the PIT gb with PITreader (see Dimensions [ 29]).
- Rotate the mounting bracket [2] into the correct position for installation.
- Fasten the PIT gb with PITreader to the mounting surface [1] and tighten the screws (including washers) with 4 Nm.
Attach coloured cap to pushbutton
- Take the required coloured cap from the set provided [3].
- Place the coloured cap [3] on the required pushbutton
- [1] so that the alignment marking [4] matches up with one of the positions illustrated [2].
- Press the coloured cap [2] downwards, as far as it will go. The pushbutton [1] is then pressed.
- When the pushbutton is pressed [1]: Run your finger around the outer edge of the coloured] cap [2] in a circular motion until it clicks into place.
Installation PITreader card holder
- Clean the two labelling surfaces [3] on the PIT gb [1]. The adhesive label positions must be smooth and free from dirt, dust and grease.
- On the first label blank [2], remove the protective film from the adhesive surface.
Do not touch the adhesive surface, to ensure that the adhesive function is not compromised. - Press the label blank [2] firmly on to the labelling surface [3].
- Follow the same procedures for the second label blank [2].
Note:
Please note that the two wings [2, 3] are different [A, B] (arrows).
Once installed [A], the respective underside of the wing must be flush with the underside of the PITreader card holder [1] (arrows).
- Check which of the two wings needs to be attached on the left [3] or right [2] on the PITreader card holder [1]. To do this, take one wing [3] or [2] and insert it with both lugs (arrows) on one side of the PITreader card holder [1].
If both wings [2, 3] are flush with the underside of the PITreader card holder [1], the wings are installed correctly. If not, swap the two wings round [2, 3]. - Now, on the PITreader card holder [1], remove the protective film from the adhesive surface.
Do not touch the adhesive surface, to ensure that the adhesive function is not compromised. - On the first wing, remove the protective film from the adhesive surface and press the wing firmly on to the PITreader card holder [1].
Do not touch the adhesive surface, to ensure that the adhesive function is not compromised. - Follow the same procedures for the second wing.
Clean the PIT gb housing [1] around the read head [5]. The adhesive position must be smooth and free from dirt, dust and grease.
- Guide the PITreader card holder [3] so that it is a little above the read head [5]; the opening [2] of the PITreader card holder [3] must face upwards.
- Do not touch the adhesive surface, to ensure that the adhesive function is not compromised.
- Align the PITreader card holder [3] horizontally so that the wings (4) can slide over the housing of the PIT gb [1].
- Guide the PITreader card holder [3] further over the read head [5] until it fits on the housing of the PIT gb [1].
- Press the PITreader card holder [3] firmly on to the housing of the PIT gb [1], around the read head [5].
Attach PITreader transponder sticker
- Attach transponder sticker, see operating manual for the PITreader.
Wiring
Note
- Information given in the Technical details [ 30] must be followed.
- The power supply must meet the regulations for extra low voltages with protective electrical separation (SELV, PELV).
- The supply voltage must be fitted with a 4 A fuse, characteristic B/C.
- Ensure the wiring and EMC requirements of EN 60204-1 are met.
- Use a 12-pin cable with an A-coded M12 female connector to connect the PIT gb with PITreader to an evaluation device (see Order reference: Accessories [ 39]).
- To connect the PIT gb with PITreader to a controller, use a 4‑pole cable with a D-coded M12 male connector (see Order reference: Accessories [ 39]).
- Route the cables so that they are protected.
Terminal assignment connectors
NOTICE
The colour marking for the connection lead only applies for the cable that Pilz supplies as an accessory.
Fig.: View of the PIT gb with PITreader from the connector end:
Position of the coding elements on the connectors to protect the cables from twisting.
Legend
- Coding element on the 12-pin connector
- Coding element on the 4-pin connector
Commissioning
Connection to evaluation device
Suitable Pilz evaluation devices for the actuation of the LED and reading out all control elements include:
- PNOZmulti
- PSSuniversal PLC
Suitable Pilz evaluation devices for the evaluation of the E-STOP, for example, are: - PNOZelog
- PNOZsigma
- PNOZ X
The correct connection to the respective evaluation device is described in the operating manual for the evaluation device. Make sure that the connection is made in accordance with the specifications in the operating manual for the selected evaluation device.
Configure PITreader
- Configure the authentication system PITreader, see operating manual for the PITreader.
Checking the product
Once the product has been installed and aligned, final inspections must be carried out before] it can be put into service.
INFORMATION
This inspection may only be carried out by qualified personnel.
- Check the PIT gb with PITreader for damage.
- Always test the function with a connected evaluation device.
- Check the function of the E-STOP.
- Check the function of the other control elements.
Operation
Display and control elements
The use and display of pushbutton S2 and pushbutton S3 depends on the application in the connected controller.
PITreader
Position transponder on the PITreader
Position transponder, see operating manual for the PITreader.
LED display PITreader
A description of the “LED display” can be found in the operating manual for the PITreader.
Firmware update PITreader
The firmware update for the PITreader authentication system is described in the operating manual for the PITreader (see Additional documents that apply [ 9]).
Reset PITreader to default setting
Procedure:
- Switch off the supply voltage to the PIT gb with PITreader.
- Press and hold pushbutton S2.
- Switch on the supply voltage to the PIT gb with PITreader.
- When the yellow LED lights up, release pushbutton S2.
- Press pushbutton S2 again with 10 seconds.
The LED lights up yellow and then green.
The PIT gb with PITreader has been reset successfully.
Status of LEDs on the PITreader when resetting to the factory default settings
Troubleshooting
Fault | Cause | Remedy |
LED off | V voltage supply not present and/or no signal at the corresponding input |
|
No output signal with control element operation | 24 V voltage supply not present | Check the wiring of the inputs and outputs. Rectify the wiring error. |
Product’s function compromised | Connection cable damaged | Check the connection cable. If necessary, change the connection cable. |
Control element damaged | External force | Contact Pilz and arrange a re-placement for the product. |
LED on the PITreader flashes red | Fault on the PITreader (e.g. hardware error, configuration error, invalid or uncoded transponder key, transponder card or transponder sticker, …) | Appropriate measures, see LED display PITreader. |
Maintenance and testing
It is not necessary to perform maintenance work on the product in normal operation.
- Please return any faulty product to Pilz.
Cleaning
- Clean the product monthly.
- Use a soft cloth and mild detergent for cleaning.
Monthly check
- Perform a manual function test [ 25] of the PIT gb with PITreader every month.
INFORMATION
This inspection may only be carried out by qualified personnel.
Check after modifications
- Inspect the PIT gb with PITreader each time the plant/machine is modified.
Exchanging the PIT gb with PITreader is also to be classed as a modification. - During the inspection you must comply with the requirements of the applicable national regulations.
INFORMATION
This inspection may only be carried out by qualified personnel.
Dimensions
Technical details
General | G1000020 | G1000021 | G1000041 | G1000042 |
Certifications | CE, EAC, FCC, IC, UKCA, UL/cUL | CE, EAC, FCC, IC, UKCA, UL/cUL | CE, EAC, FCC, IC, UKCA, UL/cUL | CE, EAC, FCC, IC, UKCA, UL/cUL |
Self-monitored | No | No | No | No |
Lamp | ||||
Kind | LED | LED | LED | LED |
Colour | White | White | White | White |
Transponders | G1000020 | G1000021 | G1000041 | G1000042 |
Transponder type | Transponder keys | Transponder keys | Transponder card, transponder key, transponder sticker | Transponder card, transponder key, transponder sticker |
Electrical data | G1000020 | G1000021 | G1000041 | G1000042 |
Supply voltage | ||||
Voltage | 24 V | 24 V | 24 V | 24 V |
Kind | DC | DC | DC | DC |
Type of power supply | SELV/PELV | SELV/PELV | SELV/PELV | SELV/PELV |
Voltage tolerance | -15 %/+20 % | -15 %/+20 % | -15 %/+20 % | -15 %/+20 % |
Output of external power supply (DC) | 3,5 W | 3,5 W | 3,5 W | 3,5 W |
Duty cycle | 100 % | 100 % | 100 % | 100 % |
Min. contact current | 1 mA | 1 mA | 1 mA | 1 mA |
Emergency stop | G1000020 | G1000021 | G1000041 | G1000042 |
Quantity | 1 | 1 | 1 | 1 |
Number of N/C contacts | 2 | 2 | 2 | 2 |
Number of signal contacts | 1 | 1 | 1 | 1 |
E-STOP release type | Turn release | Turn release | Turn release | Turn release |
Utilisation category | ||||
in accordance with the standard | EN 60947-5-1 | EN 60947-5-1 | EN 60947-5-1 | EN 60947-5-1 |
DC13 at | 24 V | 24 V | 24 V | 24 V |
Current | 0,1 A | 0,1 A | 0,1 A | 0,1 A |
Contact material | Ag | Ag | Ag | Ag |
Mechanical life | 6050 cycles | 6050 cycles | 6050 cycles | 6050 cycles |
Pushbutton | G1000020 | G1000021 | G1000041 | G1000042 |
Quantity | 2 | 2 | 2 | 2 |
Number of N/O contacts | 2 | 2 | 2 | 2 |
Pushbutton | G1000020 | G1000021 | G1000041 | G1000042 |
Utilisation category | ||||
in accordance with the standard | EN 60947-5-1 | EN 60947-5-1 | EN 60947-5-1 | EN 60947-5-1 |
DC13 at | 24 V | 24 V | 24 V | 24 V |
Max. current | 0,1 A | 0,1 A | 0,1 A | 0,1 A |
Mechanical life | 1,000,000 cycles | 1,000,000 cycles | 1,000,000 cycles | 1,000,000 cycles |
B10 | 1,300,000 cycles | 1,300,000 cycles | 1,300,000 cycles | 1,300,000 cycles |
Contact material | Ag | Ag | Ag | Ag |
PITreader | G1000020 | G1000021 | G1000041 | G1000042 |
Sensor’s mode of operation | Transponders | Transponders | Transponders | Transponders |
Transponder’s en- | passive (battery | passive (battery | passive (battery | passive (battery |
ergy supply | free) | free) | free) | free) |
Frequency band | 13,24 – 13,88 MHz | 13,24 – 13,88 MHz | 13,24 – 13,88 MHz | 13,24 – 13,88 MHz |
Max. transmitter out-put | 170 mW | 170 mW | 120 mW | 120 mW |
Supply interruption before de-energise- tion | 10 ms | 10 ms | 10 ms | 0 ms |
Galvanic isolation (semiconductor out- put) | No | No | No | No |
Switching current per semiconductor output | 100 mA | 100 mA | 100 mA | 100 mA |
Short circuit proof (semiconductor out- put) | Yes | Yes | Yes | Yes |
Signal level at “1” (input) |
15 – 30 V DC |
15 – 30 V DC |
15 – 30 V DC |
15 – 30 V DC |
Input current range | 4 mA | 4 mA | 4 mA | 4 mA |
Galvanic isolation (input) |
No |
No |
No |
No |
MTBF | 36 Jahre | 36 Jahre | 36 Jahre | 36 Jahre |
Ethernet interface | G1000020 | G1000021 | G1000041 | G1000042 |
Quantity | 1 | 1 | 1 | 1 |
IP address, factory setting |
192.168.0.12 |
192.168.0.12 |
192.168.0.12 |
192.168.0.12 |
Connection type | M12x1, 4-pin, D-
code |
M12x1, 4-pin, D-
code |
M12x1, 4-pin, D-
code |
M12x1, 4-pin, D-
code |
Transmission rate | 10/100 Mbit/s | 10/100 Mbit/s | 10/100 Mbit/s | 10/100 Mbit/s |
Environmental data | G1000020 | G1000021 | G1000041 | G1000042 |
Ambient temperat- ure | ||||
Temperature range | -20 – 55 °C | -20 – 55 °C | -20 – 55 °C | -20 – 55 °C |
Environmental data G1000020 | G1000021 | G1000041 | G1000042 | |
Storage temperature | ||||
Temperature
range -25 – 70 °C |
-25 – 70 °C |
-25 – 70 °C |
-25 – 70 °C |
|
Climatic suitability | ||||
in accordance with the standard |
EN 60068-2-78 |
EN 60068-2-78 |
EN 60068-2-78 |
EN 60068-2-78 |
Humidity | 93 % r. h. at 40 °C | 93 % r. h. at 40 °C | 93 % r. h. at 40 °C | 93 % r. h. at 40 °C |
EMC | EN 301489-1 V2.1.1 | EN 301489-1 V2.1.1 | EN 301489-1 V2.2.3 | EN 301489-1 V2.2.3 |
Vibration | ||||
in accordance with the standard |
EN 60947-5-2 |
EN 60947-5-2 |
EN 60947-5-2 |
EN 60947-5-2 |
Frequency | 10 – 55 Hz | 10 – 55 Hz | 10 – 55 Hz | 10 – 55 Hz |
Amplitude | 1 mm | 1 mm | 1 mm | 1 mm |
Shock stress | ||||
in accordance with the standard |
EN 60947-5-2 |
EN 60947-5-2 |
EN 60947-5-2 |
EN 60947-5-2 |
Acceleration | 30g | 30g | 30g | 30g |
Duration | 11 ms | 11 ms | 11 ms | 11 ms |
Airgap creepage | ||||
in accordance with the standard |
EN 60947-1 |
EN 60947-1 |
EN 60947-1 |
EN 60947-1 |
Overvoltage cat- egory |
III |
III |
III |
III |
Pollution degree | 3 | 3 | 3 | 3 |
Protection type | ||||
Housing | IP65 | IP65 | IP64 | IP64 |
in accordance with UL |
Type 1 |
Type 1 |
Type 1 |
Type 1 |
Mechanical data | G1000020 | G1000021 | G1000041 | G1000042 |
Mounting position | Any | Any | Any | Any |
Connection type | M12, 12-pin male connector | M12, 12-pin male connector | M12, 12-pin male connector | M12, 12-pin male connector |
Material | ||||
Housing | Zn | Zn | Zn | Zn |
Connection type | M12 | M12 | M12 | M12 |
Fixing screws torque settings |
4 Nm |
4 Nm |
4 Nm |
4 Nm |
Dimensions | ||||
Height | 320 mm | 320 mm | 320 mm | 320 mm |
Width | 40 mm | 40 mm | 40 mm | 40 mm |
Depth | 40 mm | 40 mm | 40 mm | 40 mm |
Weight | 920 g | 920 g | 920 g | 920 g |
Where standards are undated, the 2020-08 latest editions shall apply.
Safety characteristic data
NOTICE
You must comply with the safety characteristic data in order to achieve the required safety level for your plant/machine.
Operating mode B10d in accordance with EN ISO 13849-1: 2015 and EN 62061
E-STOP with signal contact 130.000
Supplementary data
Radio approvals
PIT gb with PITreader Key
USA/Canada
FCC ID: VT8-
IC: 7482AFCC/
IC-Requirements:
This product complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS standards.
Operation is subject to the following two conditions:
- this product may not cause harmful interference, and
- this product must accept any interference received, including interference that may cause undesired operation.
Changes or modifications made to this product not expressly approved by Pilz may void the FCC authorization to operate this equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Network data
Pro- tocol | Direc- tion [*] | Trans- port protocol | Port no. | Can be deactivated | Description |
HTTP | In | TCP | 1 … 65535
Default: 80 |
Yes | Web application:
Browser is always forwarded to HTTPS |
HTTPS | In | TCP | 1 … 65535
Default: 443 |
No | Web application:
Transport protection by TLSv1.2. Access to the web application via username and password. The server is authenticated via an X.509 certificate. |
Modbus TCP | In | TCP | 1 … 65535
Default: 502 |
Yes Default: Inactive | Modbus/TCP Server |
NTP | Out | UDP | 1 … 65535
Default: 123 |
Yes Default: Inactive | SNTP Client |
OPC UA | In | TCP | 4840 | Yes Default: Inactive | PITreader OPC Server UA |
mDNS | In | UDP | 5353 | Yes | Network discovery with Multicast DNS
(224.0.0.251) |
Multicast configuration | In | UDP | 7075 | Yes | Network configuration via Multicast protocol
(239.255.0.12) |
out: The product starts communication with the communication partner.
Order reference
Product
Product type | Features | Order no. |
PIT gb RLLE y up ETH | PITgatebox with PITreader Key (pushbutton unit), housing with E- STOP (2 NC/1 NO), 2 illuminated pushbuttons (1 NO each) and PITreader Key, top connection, M12, 12-pin male connector and M12, 4-pin female connector, Ethernet interface, IP65, 5 coloured caps in GN, BU, RD, YE and transparent | G1000020 |
PIT gb RLLE y down ETH | PITgatebox with PITreader Key (pushbutton unit), housing with E- STOP (2 NC/1 NO), 2 illuminated pushbuttons (1 NO each) and PITreader Key, bottom connection, M12, 12-pin male connector and M12, 4-pin female connector, Ethernet interface, IP65, 5 col- oured caps in GN, BU, RD, YE and transparent | G1000021 |
PIT gb QLLE y up ETH | PITgatebox with PITreader Card (pushbutton unit), housing with E- STOP (2 NC/1 NO), 2 illuminated pushbuttons (1 NO each) and PITreader Card, top connection, M12, 12-pin male connector and M12, 4-pin female connector, Ethernet interface, IP65, 5 coloured caps in GN, BU, RD, YE and transparent | G1000041 |
PIT gb QLLE y down ETH | PITgatebox with PITreader Card (pushbutton unit), housing with E- STOP (2 NC/1 NO), 2 illuminated pushbuttons (1 NO each) and PITreader Card, bottom connection, M12, 12-pin male connector and M12, 4-pin female connector, Ethernet interface, IP65, 5 col- oured caps in GN, BU, RD, YE and transparent | G1000042 |
Transponder key
Product type | Features | Order no. |
PITreader key ye g | Transponder key for authentication system PITreader, permissions freely configurable
Colour: yellow Material: plastic |
402260 |
PITreader key ye g bk | Generic transponder key for authentication system PITreader, per- missions freely configurable
Colour: black Material: plastic |
402260BK |
PITreader key ye g bl | Generic transponder key for authentication system PITreader, per- missions freely configurable
Colour: blue Material: plastic |
402260BL |
PITreader key ye g gn | Generic transponder key for authentication system PITreader, per- missions freely configurable
Colour: green Material: plastic |
402260GN |
PITreader key ye g rd | Generic transponder key for authentication system PITreader, per- missions freely configurable
Colour: red Material: plastic |
402260RD |
Product type | Features | Order no. |
PITreader key ye g wt | Generic transponder key for authentication system PITreader, per- missions freely configurable
Colour: white Material: plastic |
402260WT |
PITreader key ye g ye | Generic transponder key for authentication system PITreader, per- missions freely configurable
Colour: light yellow Material: plastic |
402260YE |
PITreader key ye 1 | Transponder key for authentication system PITreader, permission for operating mode 1
Colour: yellow Material: plastic |
402261 |
PITreader key ye 2 | Transponder key for authentication system PITreader, permission for operating mode 1 and 2
Colour: yellow Material: plastic |
402262 |
PITreader key ye 3 | Transponder key for authentication system PITreader, permission for operating mode 1, 2 and 3
Colour: yellow Material: plastic |
402263 |
PITreader key ye 4 | Transponder key for authentication system PITreader, permission for operating mode 1, 2, 3 and 4
Colour: yellow Material: plastic |
402264 |
PITreader key ye 5 | Transponder key for authentication system PITreader, permission for operating mode 1, 2, 3, 4 and 5
Colour: yellow Material: plastic |
402265 |
PITreader key ye 5 service | Transponder key for authentication system PITreader, permission for operating mode 1, 2, 3, 4 and 5 (Service)
Colour: yellow Material: plastic |
402269 |
Transponder cards
Product type | Features | Order no. |
PITreader card ye g | Transponder card for authentication system PITreader Card, per- missions freely configurable
Colour: yellow Material: plastic |
402330 |
PITreader card ye 1 | Transponder card for authentication system PITreader Card, permission for operating mode 1
Colour: yellow Material: plastic |
402331 |
PITreader card ye 2 | Transponder card for authentication system PITreader Card, permission for operating mode 1 and 2
Colour: yellow Material: plastic |
402332 |
Product type | Features | Order no. |
PITreader card ye 3 | Transponder card for authentication system PITreader Card, permission for operating mode 1, 2 and 3
Colour: yellow Material: plastic |
402333 |
PITreader card ye 4 | Transponder card for authentication system PITreader Card, permission for operating mode 1, 2, 3 and 4
Colour: yellow Material: plastic |
402334 |
PITreader card ye 5 | Transponder card for authentication system PITreader Card, permission for operating mode 1, 2, 3, 4 and 5
Colour: yellow Material: plastic |
402335 |
PITreader card ye 5 service | Transponder card for authentication system PITreader Card, permission for operating mode 1, 2, 3, 4 and 5 (Service)
Colour: yellow Material: plastic |
402339 |
Transponder sticker
Product type | Features | Order no. |
PITreader sticker ye g | Transponder sticker for authentication system PITreader Card, per- missions freely configurable
Colour: yellow Material: plastic |
402340 |
PITreader sticker ye 1 | Transponder sticker for authentication system PITreader Card, permission for operating mode 1
Colour: yellow Material: plastic |
402341 |
PITreader sticker ye 2 | Transponder sticker for authentication system PITreader Card, permission for operating mode 1 and 2
Colour: yellow Material: plastic |
402342 |
PITreader sticker ye 3 | Transponder sticker for authentication system PITreader Card, permission for operating mode 1, 2 and 3
Colour: yellow Material: plastic |
402343 |
PITreader sticker ye 4 | Transponder sticker for authentication system PITreader Card, permission for operating mode 1, 2, 3 and 4
Colour: yellow Material: plastic |
402344 |
PITreader sticker ye 5 | Transponder sticker for authentication system PITreader Card, permission for operating mode 1, 2, 3, 4 and 5
Colour: yellow Material: plastic |
402345 |
PITreader sticker ye 5 service | Transponder sticker for authentication system PITreader Card, permission for operating mode 1, 2, 3, 4 and 5 (Service)
Colour: yellow Material: plastic |
402349 |
Accessories
Coloured caps
Product type | Features | Order no. |
PIT gb color covers | Colour covers for the illuminated pushbuttons (set) | G1000009 |
PIT gb color cover wh s1 | Colour covers for the illuminated pushbuttons, white, IEC symbol Start | G1000013 |
PIT gb color cover wh s2 | Colour covers for the illuminated pushbuttons, white, IEC symbol ON | G1000014 |
PIT gb color cover wh s3 | Colour covers for the illuminated pushbuttons, white, IEC symbol Unlocking | G1000015 |
PIT gb color cover wh s4 | Colour covers for the illuminated pushbuttons, white, IEC symbol Locking | G1000016 |
PIT gb color cover bl s5 | Colour covers for the illuminated pushbuttons, blue, IEC symbol Re-quest | G1000017 |
PIT gb color cover bl s6 | Colour covers for the illuminated pushbuttons, blue, IEC symbol Reset | G1000018 |
PIT gb color cover bl s4 | Colour covers for the illuminated pushbuttons, blue, IEC symbol Locking | G1000019 |
PITgatebox card holder
Product type | Features | Order no. |
PITgatebox card holder | Transponder mounting for the authentication system PITreader Card on the PITgatebox | 402324 |
Cable
Product type | Features | Connector X1 | Connector X2 | Connector X3 | Order no. |
PSEN cable M12-12sf 2m | 2 m | M12, 12-pin female connector, straight | 570350 | ||
PSEN cable M12-12sf 3m | 3 m | M12, 12-pin female connector, straight | 570351 | ||
PSEN cable M12-12sf 5m | 5 m | M12, 12-pin female connector, straight | 570352 | ||
PSEN cable M12-12sf 10m | 10 m | M12, 12-pin female connector, straight | 570353 | ||
PSEN cable M12-12sf 20m | 20 m | M12, 12-pin female connector, straight | 570354 | ||
PSEN cable M12-12sf 30m | 30 m | M12, 12-pin female connector, straight | 570355 |
Product type | Features | Connector X1 | Connector X2 | Connector X3 | Order no. |
PSEN cable M12-12sf 50m | 50 m | M12, 12-pin female connector, straight | 570356 | ||
PSEN cable M12-12sf/ M12-12sm 1m | 1 m | M12, 12-pin female connector, straight | M12, 12-pin male connector, straight | 570357 | |
PSEN cable M12-12sf/ M12-12sm 2m | 2 m | M12, 12-pin female connector, straight | M12, 12-pin male connector, straight | 570358 | |
PSEN cable M12-12sf/ M12-12sm 3m | 3 m | M12, 12-pin female connector, straight | M12, 12-pin male connector, straight | 570359 | |
PSEN cable M12-12sf/ M12-12sm 5m | 5 m | M12, 12-pin female connector, straight | M12, 12-pin male connector, straight | 570360 | |
PSEN cable M12-12sf/
M12-12sm 10m |
10 m | M12, 12-pin female connector, straight | M12, 12-pin male connector, straight | 570361 | |
PSEN cable M12-12sf/
M12-12sm 20m |
20 m | M12, 12-pin female connector, straight | M12, 12-pin male connector, straight | 570362 | |
SafetyNET p cable | By the metre, 4-pin.CAT5e | 380000 |
Connector
Product type | Features | Connector X1 | Connector X2 | Connector X3 | Order no. |
M12 con., straight, male, 4-pin, D | D-coded | M12, 4-pin male connector, straight | 380316 | ||
SafetyNET p connector RJ45s | 4-pin RJ45 male connector, straight, Cat 5a | 380400 |
EC declaration of conformity
This product/these products meet(s) the requirements of the following directives of the European Parliament and of the Council.
- 2006/42/EC on machines
- 2014/53/EU on radio equipment
- The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads
- Representative: Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ostfildern, Germany
UKCA-Declaration of Conformity
This product(s) complies with following UK legislation:
- Supply of Machinery (Safety) Regulations 2008
- Radio Equipment Regulations 2017
- The complete UKCA Declaration of Conformity is available on the Internet at www.pilz.com/downloads
- Representative: Pilz Automation Technology, Pilz House, Little Colliers Field,
- Corby, Northamptonshire, NN18 8TJ United Kingdom, eMail: mail@pilz.co.uk
Support
Technical support is available from Pilz round the clock.
Americas
- Brazil
- +55 11 97569-2804
- Canada
- +1 888 315 7459
- Mexico
- +52 55 5572 1300
- USA (toll-free)
- +1 877-PILZUSA (745-9872)
Pilz develops environmentally-friendly products using ecological materials and energy-saving technologies. Offices and production facilities are ecologically designed, environmentally-aware and energy-saving. So Pilz offers sustainability, plus the security of using energy-efficient products and environmentally-friendly solutions.
CECE®, CHRE®, CMSE®, INDUSTRIAL PI®, Leansafe®, Myzel®, PAS4000®, PAScal®, PASconfig®, Pilz®, PIT®, PMCprimo®, PMCprotego®, PMCtendo®, PMD®, PMI®,
PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®, SafetyEYE®, SafetyNET p®, THE SPIRIT OF SAFETY® are registered and protected trademarks of Pilz GmbH & Co. KG in some countries. We would point out that product features may vary from the details stated in this document, depending on the status at the time of publication
and the scope of the equipment. We accept no responsibility for the validity, accuracy and entirety of the text and graphics presented in this information.
Please contact our Technical Support if you have any questions.
We are represented internationally. Please refer to our homepage www.pilz.com for further details or contact our headquarters.
Headquarters: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, E-Mail: info@pilz.com Internet: www.pilz.com
Documents / Resources
![]() |
PILZ VT8-PITGB11 PIT gb with PIT Reader [pdf] Owner's Manual VT8-PITGB11 PIT gb with PIT Reader, VT8-PITGB11, PIT gb with PIT Reader, with PIT Reader, PIT Reader, Reader |