PEPPERL FUCHS FB1208B Digital Input - symbol 1

FB1208B Digital Input

  • 8-channel
  • Inputs Ex ia
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • Dry contact or NAMUR inputs
  • Positive or negative logic selectable
  • Simulation mode for service operations (forcing)
  • Line fault detection (LFD)
  • Permanently self-monitoring
  • On/Off delay

Function

The device accepts digital input signals of NAMUR sensors or mechanical contacts from the hazardous area.
Open or short circuit line fault alarms are detected.
The inputs are galvanically isolated from the bus and the power supply (EN 60079-11).

Connection

PEPPERL FUCHS FB1208B Digital Input - Fig 1

Technical Data

Slots
Occupied slots 2
Supply
Connection backplane bus
Rated voltage Ur 12 V DC ,  only in connection with the power supplies FB92**
Power dissipation 0.95 W
Power consumption 0.95 W
Internal bus
Connection backplane bus
Interface manufacturer-specific bus to standard com unit
Digital input
Number of channels 8

Technical Data

Sensor interface
Connection NAMUR sensor
Connection [2] volt-free contact
Connection channel I: 1+, 2-; channel II: 3+, 4-; channel III: 5+, 6-; channel IV: 7+, 8-; channel V:
9+, 10-; channel VI: 11+, 12-; channel VII: 13+, 14-; channel VIII: 15+, 16-
Rated values acc. to EN 60947-5-6 (NAMUR)
Switching point/switching 1.2 … 2.1 mA / ± 0.2 mA
Internal resistor Ri 1 kΩ
Line fault detection can be switched on/off for each channel via configuration tool
Connection mechanical switch with additional resistors (see connection diagram) proximity switches without additional wiring
Short-circuit < 360 Ω
Open-circuit < 0.35 mA
Minimum pulse duration 1 ms
Indicators/settings
LED indication LED green: supply
LED red: line fault
Coding optional mechanical coding via front socket
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013
Conformity
Electromagnetic compatibility NE 21
Degree of protection IEC 60529
Environmental test EN 60068-2-14
Shock resistance EN 60068-2-27
Vibration resistance EN 60068-2-6
Damaging gas EN 60068-2-42
Relative humidity EN 60068-2-78
Ambient conditions
Ambient temperature -20 … 60 °C (-4 … 140 °F)
Storage temperature -25 … 85 °C (-13 … 185 °F)
Relative humidity 95 % non-condensing
Shock resistance shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistance frequency range 10 … 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration
± 0.075 mm/1 g; 10 cycles frequency range 5 … 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gas designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity
level G3
Mechanical specifications
Degree of protection IP20 (module) , a separate housing is required acc. to the system description
Connection removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 … 1.5 mm2) or screw terminals (0.08 … 1.5 mm2)
Mass approx. 750 g
Dimensions 57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch)
Data for application in connection with hazardous areas
EU-type examination certificate PTB 97 ATEX 1074 U
Marking PEPPERL FUCHS FB1208B Digital Input - symbol 2 II 2(1) G Ex d [ia Ga] IIC Gb
PEPPERL FUCHS FB1208B Digital Input - symbol 2  II (1) D [Ex ia Da] IIIC
Input
Voltage Uo 15.3 V
Current Io 16.1 mA
Power Po 61.8 mW (linear characteristic)
Galvanic isolation
Input/power supply, internal bus safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020
EN 60079-1:2014
EN 60079-11:2012
International approvals
ATEX approval PTB 97 ATEX 1075 ; PTB 97 ATEX 1074 U
General information
System information The module has to be mounted in appropriate backplanes and housings (FB92**) in
Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the
corresponding EC-type examination certificate.
Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Assembly

Front view

PEPPERL FUCHS FB1208B Digital Input - Fig 2

Accessories

FB9224* Field Unit
FB9225* Redundancy Field Unit
FB9248* Field Unit

PEPPERL FUCHS logo

Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Pepperl+Fuchs Group
www.pepperl-fuchs.com
USA: +1 330 486 0002
pa-info@us.pepperl-fuchs.com
Germany: +49 621 776 2222
pa-info@de.pepperl-fuchs.com
Singapore: +65 6779 9091
pa-info@sg.pepperl-fuchs.com

 

 

 

 

Documents / Resources

PEPPERL FUCHS FB1208B Digital Input [pdf] Owner's Manual
FB1208B, FB1208B Digital Input, Digital Input

References

Leave a comment

Your email address will not be published. Required fields are marked *