Driver for integrating Optoma Projectors
Via Serial and TCP/IP
Purpose:
Integration to the Control4 solution
Requirements:
Control4 system running version 2.10 or higher.
We cannot guarantee operation on all Optoma models and firmware, so please test in Trial mode
Setup for serial connection:
Attention, the driver only operates with serial parameters in 9600, none, 1, none
There is no way to make this adjustment changeable in the driver, so keep your projector with these values
Setup for network connection:
Adjustment in the Projector Menu:
- Menu – Setup – Power Settings – Power Mode (SatandBy) – Active
- Menu – Control – Telnet On
Adjustment in the driver:
Enter the projector’s IP in the “IP” property of the driver
Make sure that the IP is fixed in the projector or is reserved in the router
Driver properties:
- Debug Mode
On | Off
Used for activity tracking, typically by the developer - Chave
Cole a licença do driver - Validação
Estado da licença - Projector ID
Optional, enter the projector ID. It will always work with zero ID on the driver, even if it has another ID on the projector. You don’t need to change this field - Power On Delay-Milliseconds
Time in milliseconds that it takes the dashboard to turn on. Default 4000 (4 seconds) - Command Delay-Milliseconds
Interval in ms between commands - Last Server Version
Latest version for download - Server Version Notes
Latest Version Information
- IP
Enter the IP of your projector. Make sure the IP is fixed on the projector or reserved on the router - TCP Port
Port for network control. Default: 23 - IP Conn Status
Displays the status of the IP connection if used - Connection
Connection type. Change to IP
Send HEXA
Field for sending codes for tests.
Allows sending commands in hexadecimal, examples:
7E 30 30 31 34 30 20 32 30 0d
or
7E30303134302032300d
Note that every command must end in “0d”
POWER STATE
Displays the state of the projector, with zero off and other values, on Format:
State | Date of reading:
1 | 2025-06-20 15:43:39
LAMP USED HOURS
- Projector lamp usage reading
- Format: Hours | reading date:
- 12 | 2025-06-20 15:43:39
- Valid readings are updated only with the projector on
Programming
Send Complete Command
Allows you to send commands in hexadecimal, example: 7E 30 30 31 34 30 20 32 30 0d or 7E30303134302032300d
Note that every command must end in “0d”
Remote Command
Send Commands form protocol
Note that some commands cannot work on some models
Change Log
1060 20/06/2025 Premiere of TCP/IP for control 1050 23/04/2025 Initial Version
Documents / Resources
![]() |
Optoma Driver for integrating Optoma Projectors [pdf] Instructions 1060, 1050, Driver for integrating Optoma Projectors, integrating Optoma Projectors, Optoma Projectors, Projectors, Driver |