microsonic mic-25IUM mic Ultrasonic Sensors

Operating Manual

mic Ultrasonic Sensors with one analogue output

mic-25/IU/M
mic-35/IU/M
mic-130/IU/M
mic-340/IU/M
mic-600/IU/M

Product description
  • The mic-sensor with one analogue output measures the distance to an object within the detection zone contactless. A signal proportional to distance is created according to the adjusted window limits of the analogue characteristic curve.
  • The sensor automatically detects the load put to the analogue output and switches to current output or voltage output respectively.
  • Choosing between rising and falling output characteristic is possible.
  • The sensors are adjustable using Teach-in processes via the Comchannel (Pin 5).
  • Using the LinkControl adapter (optional accessory) all sensor parameter settings can be adjusted by a Windows® Software.
Safety Notes
  • Read the operating instructions prior to start-up.
  • Connection, installation and adjustment works may only be carried out by expert personnel.
  • No safety component in accordance with the EU Machine Directive, use in the area of personal and machine protection not permitted

The mic-sensors have a blind zone in which distance measurement is not possible. The operating range indicates the distance of the sensor that can be applied with normal reflectors with sufficient function reserve. When using good reflectors, such as a calm water surface, the sensor can also be used up to its maximum range. Objects that strongly absorb (e.g. plastic foam) or diffusely reflect sound (e.g. pebble stones) can also reduce the defined operating range.

Installation

Arrow Icon 4 Assemble the sensor at the installation location.
Arrow Icon 4 Plug in the connector cable to the M12 connector, see Fig. 1.

microsonic mic-25IUM - Plug in microsonic mic-25IUM - connector

colour

1

+UB brown
2 -UB blue

3

black
4 I/U white

5

Com grey

Fig. 1: Pin assignment with view onto sensor plug and colour coding of the microsonic connection cable

Start-up

Arrow Icon 4 Connect the power supply.
Arrow Icon 4 Set sensor parameters via the Teach-in procedure (see Diagram 1)

Factory setting

mic-sensors are delivered factory made with the following settings:

  • Rising analogue characteristic
  • Window limits for the analogue output set to blind zone and operating range
  • Maximum detection range set to maximum range
Synchronisation

If the assembly distances shown in Fig. 2 for two or more sensors are exceeded the integrated synchronisation should be used. Connect Com-channels (pin 5 at the units receptable) of all sensors (10 maximum).

microsonic mic-25IUM - Synchronisation 1 microsonic mic-25IUM - Synchronisation 2
mic-25… ≥0.35 m ≥2.50 m
mic-35… ≥0.40 m ≥2.50 m
mic-130… ≥1.10 m ≥8.00 m
mic-340… ≥2.00 m ≥18.00 m
mic-600… ≥4.00 m ≥30.00 m

Fig. 2: Assembly distances, indicating synchronisation

Maintenance

mic-sensors work maintenance free. Small amounts of dirt on the surface do not influence function. Thick layers of dirt and caked-on dirt affect sensor function and therefore must be removed.

Notes

  • mic-sensors have internal temperature compensation. Because the sensors heat up on their own, the temperature compensation reaches its optimum working point after approx. 30 minutes of operation.
  • The load put to the analogue output is detected automatically when turning supply voltage on.
  • If no signal is detected for 20 seconds during teach-in procedure the made changes are stored and the sensor returns to normal mode operation.
  • You can reset the factory settings at any time, see Diagram 1.
Diagram 1: Set sensor parameters via Teach-in procedure

Teach-in analogue output

microsonic mic-25IUM - Set sensor parameters 1

Further Settings

microsonic mic-25IUM - Set sensor parameters 2

Technical data
microsonic mic-25IUM - Analogue output
1 analogue output
mic-25… microsonic mic-25IUM - mic-25
microsonic mic-25IUM - mic-25 - 1

blind zone

0 to 30 mm

operating range

250 mm

maximum range

350 mm

angle of beam spread

see detection zone

transducer frequency

320 kHz

resolution

0.025 mm to 0.10 mm, depending on the analogue window

detection zones
for different objects:
The dark grey areas represent the zone where it is easy to recognise the normal reflector (round bar). This indicates the typical operating range of the sensors. The light grey areas represent the zone where a very large reflector – for instance a plate – can still be recognised. The requirement here is for an optimum alignment to the sensor. It is not possible to evaluate ultrasonic reflections outside this area.

microsonic mic-25IUM - mic-25 - 2

reproducibility

±0.15 %

accuracy

±1 % (Temperature drift internal compensated, may be deactivated 1), 0.17%/K without compensation)

operating voltage UB

9 to 30 V DC, short-circuit-proof, Class 2

voltage ripple

±10 %

no-load supply current

≤55 mA

housing

Brass sleeve, nickel-plated, plastic parts: PBT; Ultrasonic transducer: polyurethane foam, epoxy resin with glass content

class of protection to EN 60529

IP 67

norm conformity

EN 60947-5-2

type of connection

5-pin initiator plug, Brass, nickel-plated

controls

via Com-channel

programmable

via Teach-in and LinkControl

operating temperature 

–25 to +70 °C

storage temperature

–40 to +85 °C

weight

200 g

response time 1)

32 ms

time delay before availability 1)

<390 ms

order No.

mic-25/IU/M

Current output 4 to 20 mA

RL ≤ 100 Ω at 9 V ≤ UB ≤ 20 V;
RL ≤ 500 Ω at UB ≥ 20 V
Rising/falling output characteristic

Voltage output 0 to 10 V

RL ≥ 100 kΩ at UB ≥ 15 V, short-circuit-proof
Rising/falling output characteristic
microsonic mic-25IUM - Analogue output
1 analogue output
mic-35… microsonic mic-25IUM - mic-35
microsonic mic-25IUM - mic-35 - 1

blind zone

0 to 65 mm

operating range

350 mm

maximum range

600 mm

angle of beam spread

see detection zone

transducer frequency

400 kHz

resolution

0.025 mm to 0.17 mm, depending on the analogue window

detection zones
for different objects:
The dark grey areas represent the zone where it is easy to recognise the normal reflector (round bar). This indicates the typical operating range of the sensors. The light grey areas represent the zone where a very large reflector – for instance a plate – can still be recognised. The requirement here is for an optimum alignment to the sensor. It is not possible to evaluate ultrasonic reflections outside this area.

microsonic mic-25IUM - mic-35 - 2

reproducibility

±0.15 %

accuracy

±1 % (Temperature drift internal compensated, may be deactivated 1), 0.17%/K without compensation)

operating voltage UB

9 to 30 V DC, short-circuit-proof, Class 2

voltage ripple

±10 %

no-load supply current

≤55 mA

housing

Brass sleeve, nickel-plated, plastic parts: PBT; Ultrasonic transducer: polyurethane foam, epoxy resin with glass content

class of protection to EN 60529

IP 67

norm conformity

EN 60947-5-2

type of connection

5-pin initiator plug, Brass, nickel-plated

controls

via Com-channel

programmable

via Teach-in and LinkControl

operating temperature 

–25 to +70 °C

storage temperature

–40 to +85 °C

weight

200 g

response time 1)

64 ms

time delay before availability 1)

<420 ms

order No.

mic-35/IU/M

Current output 4 to 20 mA

RL ≤ 100 Ω at 9 V ≤ UB ≤ 20 V;
RL ≤ 500 Ω at UB ≥ 20 V
Rising/falling output characteristic

Voltage output 0 to 10 V

RL ≥ 100 kΩ at UB ≥ 15 V, short-circuit-proof
Rising/falling output characteristic
microsonic mic-25IUM - Analogue output
1 analogue output
mic-130… microsonic mic-25IUM - mic-130
microsonic mic-25IUM - mic-130 - 1

blind zone

0 to 200 mm

operating range

1,300 mm

maximum range

2,000 mm

angle of beam spread

see detection zone

transducer frequency

200 kHz

resolution

0.18 mm to 0.57 mm, depending on the analogue window

detection zones
for different objects:
The dark grey areas represent the zone where it is easy to recognise the normal reflector (round bar). This indicates the typical operating range of the sensors. The light grey areas represent the zone where a very large reflector – for instance a plate – can still be recognised. The requirement here is for an optimum alignment to the sensor. It is not possible to evaluate ultrasonic reflections outside this area.

microsonic mic-25IUM - mic-130 - 2

reproducibility

±0.15 %

accuracy

±1 % (Temperature drift internal compensated, may be deactivated 1), 0.17%/K without compensation)

operating voltage UB

9 to 30 V DC, short-circuit-proof, Class 2

voltage ripple

±10 %

no-load supply current

≤55 mA

housing

Brass sleeve, nickel-plated, plastic parts: PBT; Ultrasonic transducer: polyurethane foam, epoxy resin with glass content

class of protection to EN 60529

IP 67

norm conformity

EN 60947-5-2

type of connection

5-pin initiator plug, Brass, nickel-plated

controls

via Com-channel

programmable

via Teach-in and LinkControl

operating temperature 

–25 to +70 °C

storage temperature

–40 to +85 °C

weight

200 g

response time 1)

92 ms

time delay before availability 1)

<440 ms

order No.

mic-130/IU/M

Current output 4 to 20 mA

RL ≤ 100 Ω at 9 V ≤ UB ≤ 20 V;
RL ≤ 500 Ω at UB ≥ 20 V
Rising/falling output characteristic

Voltage output 0 to 10 V

RL ≥ 100 kΩ at UB ≥ 15 V, short-circuit-proof
Rising/falling output characteristic
microsonic mic-25IUM - Analogue output
1 analogue output
mic-340… microsonic mic-25IUM - mic-340
microsonic mic-25IUM - mic-340 - 1

blind zone

0 to 350 mm

operating range

3,400 mm

maximum range

5,000 mm

angle of beam spread

see detection zone

transducer frequency

120 kHz

resolution

0.18 mm to 1.5 mm, depending on the analogue window

detection zones
for different objects:
The dark grey areas represent the zone where it is easy to recognise the normal reflector (round bar). This indicates the typical operating range of the sensors. The light grey areas represent the zone where a very large reflector – for instance a plate – can still be recognised. The requirement here is for an optimum alignment to the sensor. It is not possible to evaluate ultrasonic reflections outside this area.

microsonic mic-25IUM - mic-340 - 2

reproducibility

±0.15 %

accuracy

±1 % (Temperature drift internal compensated, may be deactivated 1), 0.17%/K without compensation)

operating voltage UB

9 to 30 V DC, short-circuit-proof, Class 2

voltage ripple

±10 %

no-load supply current

≤55 mA

housing

Brass sleeve, nickel-plated, plastic parts: PBT; Ultrasonic transducer: polyurethane foam, epoxy resin with glass content

class of protection to EN 60529

IP 67

norm conformity

EN 60947-5-2

type of connection

5-pin initiator plug, Brass, nickel-plated

controls

via Com-channel

programmable

via Teach-in and LinkControl

operating temperature 

–25 to +70 °C

storage temperature

–40 to +85 °C

weight

260 g

response time 1)

172 ms

time delay before availability 1)

<530 ms

order No.

mic-340/IU/M

Current output 4 to 20 mA

RL ≤ 100 Ω at 9 V ≤ UB ≤ 20 V;
RL ≤ 500 Ω at UB ≥ 20 V
Rising/falling output characteristic

Voltage output 0 to 10 V

RL ≥ 100 kΩ at UB ≥ 15 V, short-circuit-proof
Rising/falling output characteristic
microsonic mic-25IUM - Analogue output
1 analogue output
mic-600… microsonic mic-25IUM - mic-600
microsonic mic-25IUM - mic-600 - 1

blind zone

0 to 600 mm

operating range

6,000 mm

maximum range

8,000 mm

angle of beam spread

see detection zone

transducer frequency

80 kHz

resolution

0.18 mm to 2.4 mm, depending on the analogue window

detection zones
for different objects:
The dark grey areas represent the zone where it is easy to recognise the normal reflector (round bar). This indicates the typical operating range of the sensors. The light grey areas represent the zone where a very large reflector – for instance a plate – can still be recognised. The requirement here is for an optimum alignment to the sensor. It is not possible to evaluate ultrasonic reflections outside this area.

microsonic mic-25IUM - mic-600 - 2

reproducibility

±0.15 %

accuracy

±1 % (Temperature drift internal compensated, may be deactivated 1), 0.17%/K without compensation)

operating voltage UB

9 to 30 V DC, short-circuit-proof, Class 2

voltage ripple

±10 %

no-load supply current

≤55 mA

housing

Brass sleeve, nickel-plated, plastic parts: PBT; Ultrasonic transducer: polyurethane foam, epoxy resin with glass content

class of protection to EN 60529

IP 67

norm conformity

EN 60947-5-2

type of connection

5-pin initiator plug, Brass, nickel-plated

controls

via Com-channel

programmable

via Teach-in and LinkControl

operating temperature

–25 to +70 °C

storage temperature

–40 to +85 °C

weight

320 g

response time 1)

240 ms

time delay before availability 1)

<600 ms

order No.

mic-600/IU/M

Current output 4 to 20 mA

RL ≤ 100 Ω at 9 V ≤ UB ≤ 20 V;
RL ≤ 500 Ω at UB ≥ 20 V
Rising/falling output characteristic

Voltage output 0 to 10 V

RL ≥ 100 kΩ at UB ≥ 15 V, short-circuit-proof
Rising/falling output characteristic

1) Can be programmed via LinkControl.

microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E info@microsonic.de / W microsonic.de
The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.

UL Listed IconEnclosure Type 1
For use only in industrial machinery NFPA 79 applications.

The proximity switches shall be used with a Listed (CYJV/7) cable/connector assembly rated minimum 32 Vdc, minimum 290 mA, in the final installation.

Disposal Icon 6  UKCA Icon CE Icon 2014/30/EU

microsonic mic-25IUM - Bar code