IMPORTANT SAFETY PRECAUTIONS

READ THIS BEFORE USE

  1. Use this device ONLY for the intended use described in this manual.
  2. Do NOT use accessories which are not specified by the manufacturer.
  3. Do NOT use the device if it is not working properly or damaged.
  4. Do NOT use the equipment where aerosol sprays are being used, or where oxygen is being administered.
  5. Do NOT use it under any circumstances on newborns.
  6. This device does NOT serve as a cure for any symptoms or diseases. The data measured are for reference only. Always consult your doctor to have the results interpreted.
  7. Keep the equipment and its flexible cord away from hot surfaces.
  8. Do NOT apply the cuff to areas other than the place directed.
  9. Do not remove the plastic wrapping membrane to ensure the waterproof function.
  10. Proper maintenance and periodic calibration are essential to the longevity of your device. If you are concerned about your accuracy of measurement, please contact local customer service for help.

BEFORE YOU BEGIN

INTENDED USE

  • The Blood Pressure Monitor is a system designed to measure people”s systolic. diastolic blood pressure and pulse rate at home and in clinical settings by using a non-invasive technique in which an inflatable cuff is wrapped on the upper arm.
  • This system is intended for individuals aged 18 or above.
  • Do not use it for diagnosis of hypertension or testing on newborns, babies, young children, or persons who cannot express their consent.

TEST PRINCIPLE

  • Blood pressure is measured non-invasively at the arm based on the oscillometric method.
  • If you have been diagnosed with severe arrhythmia or irregular heartbeat, atrial or ventricular premature beats, or atrial fibrillation, measurements made with this instrument should only be evaluated after consultation with the doctor or your healthcare professionals.

Electromagnetic interference

  • The device contains sensitive electronic components.
  • Avoid strong electromagnetic fields in the direct vicinity of the device (e.g. mobile phones, microwave ovens.
  • Electrical interference can lead to temporary impairment of the measuring accuracy).

MONITOR OVERVIEW

Device

  1. CUFF Connector
  2. SET button
  3. LCD display
  4. CUFF
  5. USB socket
  6. MEM BUTTON
  7. START/STOP button

MEDTECH-BP12-Digital-BP-Meter-fig-1

Cuff

  • We offer a cuff measuring size: 22-42 cm suitable for most arm circumferences
  • Do not use accessories or equipment which are not certified by the manufacturer. they might increase emissions or decrease the immunity of this system.

DISPLAY SCREEN

MEDTECH-BP12-Digital-BP-Meter-fig-2

  1. Systolic Pressure icon and unit Date
  2. WHO classification bar
  3. Low battery icon
  4. Diastolic Pressure icon and unit
  5. Anm moving icon Blue tooth icon
  6. Irregular heartbeat detector
  7. Memory icon and index
  8. User
  9. DateTime
  10. Systolic Pressure
  11. Diastolic Pressure
  12. Heartbeat icon
  13. Heartbeat rate
  14. Heartbeat rate unit

SETTING THE MONITOR

  • Before using your monitor for the first time, check and update these settings.
  • Make sure you complete the steps below and save the desired settings.

INSERT BATTERIES

  • After you have unpacked your device, first insert the attached batteries (4 x size AA 1.5V) with the indicated polarity.
  • The battery compartment is located at the side of the device (see illustration).

MEDTECH-BP12-Digital-BP-Meter-fig-3

Note

  • After the warningMEDTECH-BP12-Digital-BP-Meter-fig-4 appears, the device is blocked till the batteries have been replaced.
  • Please use 4 pcs “AA” Long-Life Alkaline 1.5V Batteries.
  • If the blood pressure monitor is left unused for long periods, please remove the batteries.

ENTER THE SETTING MODE

  • Press the SET button for 3 sec then the “2021” flashes on LCD. (The meter comes into Setting mode if supplying power the first time)

MEDTECH-BP12-Digital-BP-Meter-fig-5

SETTING THE DATE AND TIME

  • a. When the year flashes, press the MEM button until the correct year appears.
  • Press the SET button to confirm and change to the Month setting.
  • b. When the month flashes, press the MEM button until the correct month appears.
  • Press the SET button to confirm and change to date setting.

MEDTECH-BP12-Digital-BP-Meter-fig-6

  • Set the day, hour, and minute in the same way as described above.

MEDTECH-BP12-Digital-BP-Meter-fig-7

NOTE

  • If the meter is idle for 1.5 minutes during the setting mode, it will switch off automatically.

User selection

  • User 1 is the default user and user 1 flashes. Press the M-button to select the user Press the SET button to confirm.

MEDTECH-BP12-Digital-BP-Meter-fig-8

  • The user can switch when the meter stands by pressing the SET button shortly.

Unit selection

  • a. Press the M-button to choose the unit
  • b. Press the SET button to confirm

MEDTECH-BP12-Digital-BP-Meter-fig-9

TESTING YOUR BLOOD PRESSURE

BEFORE MEASUREMENT

  • Avoid caffeine, tea, alcohol, and tobacco for at least 30 minutes before measurement.
  • Wait 30 minutes after exercising or bathing before measurement.
  • Sit or lie down for at least 10 minutes before measurement.
  • Do not measure when feeling anxious or tense.
  • Take a 5-10-minute break between measurements. This break can be longer if necessary, depending on your physical condition
  • Keep the records for your doctor as a reference.
  • Blood pressure naturally varies between each arm. Always measure your blood pressure on the same arm.

FITTING THE CUFF PROPERLY

  • Plug the cuff connector into the cuff socket on the device’s left side.
  • Assemble the cuff as shown below. The smooth surface should be inside of the cuff loop and the metal D-ring should not touch your skin.

MEDTECH-BP12-Digital-BP-Meter-fig-10

  • Stretch your left (right) arm in front of you with your palm facing up. Slide and place the cuff onto your arm to let the air tube and artery mark the region toward the lower arm.
  • Wrap and tighten the cuff above your elbow. The artery mark on the edge of the cuff should be approx. 0.8″ to 1.2″ (2 cm to 3 cm) above your elbow. Align the lube over the main arteries on the inside.

MEDTECH-BP12-Digital-BP-Meter-fig-11

  • Leave a little free space between the arm and the cuff: you should be able to fit two fingers between them.
  • Remove all clothing covering or constricting the measurement arm.
  • Press the hook material firmly against the pile material. The top and bottom edges of the cuff should be tightened evenly around your upper arm.

MEDTECH-BP12-Digital-BP-Meter-fig-12

PROPER MEASUREMENT POSITION

  • Sit down for at least 10 minutes before measuring.
  • Place your elbow on a flat surface. Relax your hand with the palm facing up.
  • Make sure the cuff is about the same height as the location of your heart.
  • Press the START/STOP button to switch on the monitor.
  • Remain still and do not talk or move during the measurement.

MEDTECH-BP12-Digital-BP-Meter-fig-13

WARNING

  • If the cuff is relatively lower (higher) than the heart, the obtained blood pressure value could be higher (lower) than the actual value. A 15 cm difference in height may result in an error of around 10 mmHg.

3.2. TAKING MEASUREMENTS
TAKING A SINGLE MEASUREMENT
Always apply the pressure cuff before turning on the monitor.

  • Press the START button, the pump begins to inflate the cuff. The rising pressure in the cuff is shown on the display.MEDTECH-BP12-Digital-BP-Meter-fig-14
  • Pressure in the cuff increases to working pressure. Then the pump stops and the pressure falls.
  • Note: In case the inflation pressure is not sufficient to determine the measurement result, the monitor automatically re-inflates to a higher level.
  • The heart symbolMEDTECH-BP12-Digital-BP-Meter-fig-15 starts to flash every heartbeat once a pulse is detected.

MEDTECH-BP12-Digital-BP-Meter-fig-16

  • After the measurement, systolic pressure, diastolic pressure, pulse rate, and color bars classified from ESH (European Society of Hypertension) standards are shown on the display .

MEDTECH-BP12-Digital-BP-Meter-fig-17

  • If an irregular heartbeat was detected during the measurement, LCD displays the “MEDTECH-BP12-Digital-BP-Meter-fig-18” icon to remind users of heartbeat irregularity. Please consult your doctor if it appears often.

MEDTECH-BP12-Digital-BP-Meter-fig-19

MONITOR MEMORY

AVERAGE OF ALL STORED MEMORIES

  • Press the MEM button, LCD shows a set of values averaged from all the stored memories, accompanied by an icon “AV’ .

MEDTECH-BP12-Digital-BP-Meter-fig-20

MEMORY RECALL

  • The device stores 90 most recent blood pressure test results along with respective dates and times in the monitor memory.

Reviewing Test Results

  • Press the MEM button again after you see the average of all stored memories, the single memory reading appears.

MEDTECH-BP12-Digital-BP-Meter-fig-21

  • Per the setting, the first reading you see is the last blood pressure result. Press the MEM button again, and the next measurement e.g. M90, as well as the previous 90 measurements (M88 M87 … M1) can be displayed one after the other.

DELETE ALL STORED MEMORIES

  • Hold down the SET button 9 times until “CL” flashes on the LCD, press the START button, and all the stored memories inside is removed.

MEDTECH-BP12-Digital-BP-Meter-fig-22

  • Before you delete all the readings stored in the memory, please make sure you will not need to use them anymore at a later time.

MAINTENANCE

CARING FOR YOUR MONITOR

  • To avoid the monitor attracting dirt, dust or other contaminants, wash and dry your hands thoroughly before use.

Cleaning

  • To clean the monitor exterior, wipe ii with a cloth moistened with tap water or a mild
  • Cleaning agent, then dry the device with a soft dry cloth. Do NOT flush with water.
  • Do NOT use organic solvents to clean the monitor.
  • Do NOT wash the pressure cuff.
  • Do NOT iron the pressure cuff.

Monitor Storage

  • Storage condition: -20°C to 55°C (-4’F to 131 °F), below 95% relative humidity.
  • Always store or transport the monitor in its original storage case.
  • Avoid dropping or heavy impact.
  • Avoid direct sunlight and high humidity.

DETAILED INFORMATION

Reference Values

  • Clinical studies show that adult diabetes is often accompanied by elevated blood pressure.
  • People with diabetes can reduce their heart risk by managing their blood pressure along with diabetes treatment*1.
  • Monitoring your routine blood pressure trend helps you to know your body condition. Human blood pressure naturally increases after reaching middle age.
  • This symptom is a result of continuous aging of the blood vessels. Further causes include obesity, lack of exercise and cholesterol (LDL) adhering to the blood vessels, and diabetes.
  • Rising blood pressure accelerates hardening of the arteries, and the body becomes more susceptible to apoplexy and coronary infarction.
  • Definitions and Classification of Blood Pressure Levels according to 2007 ESH-ESC Practice Guidelines for the Management of Arterial Hypertension:. Data in mm Hg

MEDTECH-BP12-Digital-BP-Meter-fig-23

  • Isolated systolic hypertension should be graded (1, 2, 3) according to systolic blood pressure values in the ranges indicated, provided that diastolic values are < 90mmHg.

Source: The European Society of Hypertension and European Society of Cardiology Task Force Members. 2007 ESH-ESC Practice Guidelines for the Management of Arterial Hypertension. J Hyper tens 2007; 25: 1751-1762.

SYSTEM TROUBLESHOOTING 

  • If you follow the recommended action but the problem persists, or error messages other than the ones below appear, please call your local customer service.
  • Do not attempt to repair by yourself and never try to disassemble the monitor under any circumstances.

Error Messages

Airway leakage 

  1. pressure > 300mmHg, or
  2. inflation >53 seconds, or
  3. re-pumping>20 seconds, or
  4. inflation >11 seconds but pressure< 15mmHg

Wild readings 

  1. SYS-DIA < 12mmHg, or
  2. SYS-DIA > 154mmHg

Artifact

  • Improper movement was detected during measurement.

No pulse detected 

  1. pressure< 13 mmHg, but no signal can be detected, or
  2. pressure< 41 mm Hg, signal not sufficient for SYS, DIA, and/or MAP calculation

MEDTECH-BP12-Digital-BP-Meter-fig-25

Troubleshooting

  1. If no display appears after pressing the START button:MEDTECH-BP12-Digital-BP-Meter-fig-26
  2. If the heart rate is higher/lower than the user’s average:MEDTECH-BP12-Digital-BP-Meter-fig-27
  3. If the result is higher/lower than the user’s average measurement:MEDTECH-BP12-Digital-BP-Meter-fig-28
  4. If the cuff inflates again while measuring:

MEDTECH-BP12-Digital-BP-Meter-fig-29

SYMBOL INFORMATION

MEDTECH-BP12-Digital-BP-Meter-fig-30

SPECIFICATIONS

PARAMETER SPECIFICATION
Display LCD digital display
Measuring principle Oscillometric method
Measuring localization Upper arm
Measurement range Pressure 0~299mmHg ( 0~39.9kPa)
Pulse 40~199 pulses/min
Accuracy Pressure ±3mmHg (±0.4kPa)
Pulse ±5% of reading
LCD indication Pressure 3 digits display of mmHg
Pulse 3 digits display
Symbol Memory/HeartbeaULow battery
Memory function 2X90 sets memory of measurement values
Power source 4pcs AA alkaline battery or 5.0V USB power supply
Automatic power off In 1.5 minutes
Main unit weight Approx.240g (batteries not included)
Main unit size L138mm xW98mm x H41mm
Main unit lifetime 10,000 times under normal use
Battery life Could be used 300 times for the normal condition
Accessories Cuff, instruction manual
Operating environment Temperature 5-40-C
Humidity 15%~85%RH
Air pressure 86kPa ~ 106kPa
 

Storage environment transportation environment

 

Temperature -20″C~55″ C ,Humidity:10% ~85%

Air pressure: 86kPa~106kPa avoid crashes, sunburn, or rain during transportation.

Note: the product cannot be operated at an altitude of 2000m.
  • This device has been tested to meet the electrical and safety requirements of: IEC/EN 60601-1,

Warranty conditions

NOVACHECK BP-12 Blood Pressure Monitor is made under strict quality control & utmost care is taken to ensure long, trouble-free service.

  • This unit is warranted for 24 months from the date of purchase.
  • This Card must be fully filled in stamped & signed by the dealer.
  • This card & relevant invoice must be preserved and presented to the dealer when the unit is sent for repairs.
  • We undertake to repair or replace at our discretion any part which was originally defective, provided the unit was not tampered with or mishandled.
  • It shall be the customer’s responsibility to deliver the unit to the authorized service station; freight prepaid & collect the unit from the service station after repairs.
  • The warranty is only against manufacturing defects & shall not be applicable in case of damage due to accident, acts of nature, loss of components, intentional damage, and improper installation, or if it was opened or serviced by authorized persons.
  • The warranty is void if the set is not operated according to instructions given in the “Instruction manual booklet” If any repair work is carried out by persons other than authorized company personnel, defects are caused by improper or reckless use, which shall be determined by company personnel.
  • The warranty shall not extend towards the payment of compensation to anyone or entitle the customers to the replacement of the products as a whole.
  • The warranty expressly excludes every condition or warranty whether statutory or otherwise, or any claim for consequential loss or damage.
  • Warranty does not cover accessories external to the equipment, defects caused due to causes beyond control like lightning, abnormal voltage, acts of God, or while in transit to the service center or to purchasers/premises.
  • In the event of a defect being noticed in the equipment during the warranty period, the company or its authorized customer care center/ service dealer reserves the right to retain any parts / or components replaced at its discretion.
  • IMPORTANT: Warranty is not applicable for cuff and accessories components. Cuffs and accessories should be replaced from time to time as needed.

WARRANTY CARD

MEDTECH-BP12-Digital-BP-Meter-fig-33

ARTWORK SHEET 

  • Format No: FOR/4.2/08
  • Rev No: 00
  • Rev Date: 00
Size 110 (W) X 140 (H) mm
Product S0B821-1 Blood Pressure Meter Fully Auto Arm Type BP-12
Location Product Manual
Artwork No. AR01464

MEDTECH-BP12-Digital-BP-Meter-fig-36MEDTECH-BP12-Digital-BP-Meter-fig-37

REVISION TABLE

Rev No. Rev Date Revision Details
00 09-10-2023 New Design
01 29-12-2023 Removed EC REP Details, Removed Equipment Word From Type BF and Added Symbol(MEDTECH-BP12-Digital-BP-Meter-fig-39)

CONTACT

MEDTECH LIFE PRIVATE LIMITED

  • Regd. address: B6,Byculla Service Industries, D.K.Marg, Sussex Road, Byculla (East). Mumbai 400027.
  • Maharashtra, INDIA.
  • Customer Care No. +917208088720
  • E-Mail:support@medtechlife.com
  • Website: www.medtechlife.com
  • Plot No. 05, Morai lndustial Park,
  • S.No. 315/5, Morai,
  • Valsad, Gujarat-396185