MEAN WELL RSP-3000 Series Power Supply with Single Output Installation Guide
Dimension
L | W | H |
278 | 177.8 | 63.5(2U) mm |
10.9 | 7 | 2.5(2U) Inch |
Features
- AC input 180~264VAC
- Built-in active PFC function
- High efficiency up to 91.5%
- Forced air cooling by built-in DC fan
- Output voltage programmable
- Active current sharing up to 9000W (2+1)
- Built-in remote ON-OFF control / remote sense /auxiliary power / power OK signal
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Optional conformal coating
- 5years warranty
Applications
- Factory control or automation apparatus
- Testand measurement instrument
- Laser related machine
- Burn-in facility
- Digital broadcasting
- RF application
GTIN CODE
MW Search: htips:/wiw.meanwell.comserviceGTIN.aspx
Description
RSP-3000 is a 3KW single output enclosed type AC/DC power supply. This series operates for 180~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan with fan speed control, working for the temperature up to 70°C. Moreover, RSP-3000 provides vast design flexibility by equipping various built-in functions such as the output programming, active current sharing, remote ON-OFF control, auxiliary power, etc.
Model Encoding / Order Information
SPECIFICATION
MODEL | RSP-3000-12 | RSP-3000-24 | RSP-3000-48 | |
OUTPUT | DC VOLTAGE | 12V | 24V | 48V |
RATED CURRENT | 200A | 125A | 62.5A | |
CURRENT RANGE | 0 ~ 200A | 0 ~ 125A | 0 ~ 62.5A | |
RATED POWER | 2400W | 3000W | 3000W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 10.8 ~ 13.2V | 22 ~ 28V | 43 ~ 56V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1000ms, 80ms at full load | |||
HOLD UP TIME (Typ.) | 10ms at full load | |||
INPUT | VOLTAGE RANGE | 180 ~ 264VAC 254 ~ 370VDC | ||
FREQUENCY RANGE | 47 ~ 63Hz | |||
POWER FACTOR (Typ.) | 0.95/230VAC at full load | |||
EFFICIENCY (Typ.) | 87.5% | 90% | 91.5% | |
AC CURRENT (Typ.) | 20A/180VAC 16A/230VAC | |||
INRUSH CURRENT (Typ.) | 60A/230VAC | |||
LEAKAGE CURRENT | <2.0mA / 240VAC | |||
PROTECTION | OVERLOAD | 100 ~ 112% rated output power | ||
User adjustable continuous constant current limiting or constant current limiting with delay shutdown after 5 seconds, re-power on to recover | ||||
OVER VOLTAGE | 13.8 ~ 16.8V | 28.8 ~ 33.6V | 57.6 ~ 67.2V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | |||
FUNCTION | OUTPUT VOLTAGE PROGRAMMABLE(PV) | 2.4 ~ 13.2V | 4.8 ~ 28V | 9.6 ~ 56V |
Please refer to the Function Manual. | ||||
CURRENT SHARING | Up to 9000W or (2+1) units. Please refer to the Function Manual. | |||
AUXILIARY POWER(AUX) | 12V@0.1A(Only for Remote ON/OFF control) | |||
REMOTE ON-OFF CONTROL | Please refer to the Function Manual | |||
REMOTE SENSE | Compensate voltage drop on the load wiring up to 0.25V. Please refer to the Function Manual. | |||
ALARM SIGNAL OUTPUT | Power OK signal. Please refer to the Function Manual | |||
ENVIRONMENT | WORKING TEMP. | -20 ~ +70℃ (Refer to “Derating Curve”) | ||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||
TEMP. COEFFICIENT | ±0.05%/℃ (0 ~ 50℃) | |||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |||
SAFETY & EMC(Note 4) | SAFETY STANDARDS | UL62368-1, CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, BSMI CNS14336-1, AS/NZS62368.1, IS13252(Part1)/IEC60950-1,EAC TP TC 004 approved | ||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||
EMC EMISSION | Parameter | Standard | Test Level / Note | |
Conducted | BS EN/EN55032 (CISPR32) | Class B | ||
Radiated | BS EN/EN55032 (CISPR32) | Class A | ||
Harmonic Current | BS EN/EN61000-3-2 | —– | ||
Voltage Flicker | BS EN/EN61000-3-3 | —– | ||
EMC IMMUNITY | BS EN/EN55035, BS EN/EN61000-6-2, BSMI CNS13438 | |||
Parameter | Standard | Test Level / Note | ||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | ||
Radiated | BS EN/EN61000-4-3 | Level 3 | ||
EFT / Burst | BS EN/EN61000-4-4 | Level 3 | ||
Surge | BS EN/EN61000-4-5 | Level 3, 2KV/Line-Earth ; Level 2, 1KV/Line-Line | ||
Conducted | BS EN/EN61000-4-6 | Level 3 | ||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | ||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods,>95% interruptions 250 periods | ||
OTHERS | MTBF | 677.3K hrs min. Telcordia SR-332 (Bell core) ; 75.2K hrs min. MIL-HDBK-217F (25℃) | ||
DIMENSION | 278*177.8*63.5mm (L*W*H) | |||
PACKING | 4Kg; 4pcs/16Kg/2.04CUFT | |||
NOTE |
|
Block Diagram
Static Characteristics
INPUT | MODEL | 12V | 24V | 48V |
180~264VAC | 2400W200A | 3000W125A | 3000W62.5A |
Derating Curve
Efficiency vs Load (48V Model)
The curve above is measured at 230VAC.
Function Manual
- Remote Sense
- The Remote Sense compensates voltage drop on the load wiring up to 0.25V.
- Caution: The power supply, by factory default(also the assumption for other sections), is shipped with, S &-V on CN2, as well as +S & +V, shorted by connector. When activating the Remote Sense, the +S signal should be connected to the positive terminal of the load whereas -S sign alto the negative terminal of the load.
- The Remote Sense compensates voltage drop on the load wiring up to 0.25V.
- Output Voltage Programming (or, PV / remote voltage programming / remote adjust/ margin programming/ dynamic voltage trim)
- In addition to the adjust mention the built-in potentiometer, the output voltage can be trimmed to 20~110%(Typ.) of the nominal voltage by applying EXTERNAL VOLTAGE.
- Connecting an external DC source between on CN2, and . PV & -S +S & +V, -S & -V also need to be connected
- Please do not adopt PWM signal as the EXTERNAL VOLTAGE
MODEL 12V 24V 48V PV Range 2.4 ~ 13.2V 4.8 ~ 28V 9.6 ~ 56V - The rated current should change with the Output Voltage Programming accordingly
- Caution:
- By factory default, the Output Voltage Programming is not activated, and are shorted by connector. Whenever PV(PIN3) PS(PIN4) and of CN2 this function is not needed to activate, as assumed in other sections’ diagrams, please keep shorted ; otherwise, PV(PIN3) PS(PIN4) and of CN2 the power supply will have no output.
- and of CN1 or CN2 must be disconnected if “Output Voltage Programming” function is used; otherwise, the internal PV(PIN3) PS(PIN4) electrical components may be damaged, and the power supply unit may thus be out of order.
- In addition to the adjust mention the built-in potentiometer, the output voltage can be trimmed to 20~110%(Typ.) of the nominal voltage by applying EXTERNAL VOLTAGE.
- Remote ON-OFF
- Remote ON-OFF is activated by the configuration with respect to CN1,CN2 and CN3 as shown in the following diagram.
- By factory default, and ) on CN2 are PV(PIN3) PS(PIN4 shorted by connector; likewise, and OLP(PIN9) OL-SD(PIN10)on CN3 are shorted when shipped.
Example 3.2(A): Using external voltage source
Example 3.2(B): Using internal 12V auxiliary output
Example 3.2(C): Using internal 12V auxiliary output
- Connection Method
Example 3.2(A) Example 3.2(B) Example 3.2(C) SW Logic Power supply output ON SW Open SW Open SW Close Power supply output OFF SW Close SW Close SW Open
- Remote ON-OFF is activated by the configuration with respect to CN1,CN2 and CN3 as shown in the following diagram.
- Alarm Signal Output
- Alarm signal is sent out through ” POK” & “P OK GND2 ” and pins on CN3. Please acknowledge an external voltage source is required for this fun P OK P OK GND P OK2 & P OK GND2 action.
- By factory default, and OLP(PIN9) OL-SD(PIN10) on CN3 are shorted by connector when shipped.
Function Description Output of alarm(P OK, Relay Contact) Output of alarm(P OK2, TTL Signal) P OK The signal is “Low” when the power supply is above 80% of the rated output voltage, or, say, Power OK Low(0.5V max at 500mA) Low(0.5V max at 10mA) The signal turns to be “High” when the power supply is under 80% of the rated output voltage, or, say ,Power Fail High or open(External applied voltage, 500mA max.) High or open(External applied voltage, 10mA max.) Table 3.1 Explanation of alarm
Fig. 4.2 Internal circuit of P OK (Relay, total is 10W)
Fig. 4.3 Internal circuit of P OK2 (Open collector method)
- Alarm signal is sent out through ” POK” & “P OK GND2 ” and pins on CN3. Please acknowledge an external voltage source is required for this fun P OK P OK GND P OK2 & P OK GND2 action.
- Select Overload Protection Type
- Insert the shorting connector on CN3 that is shown in Fig 5.2, the Overload Protection Type will be “constant current limiting with delay shutdown after 5 seconds, re-power on to recover”. This is the factory default.
- Remove the shorting connector on CN3 that is shown in Fig 5.1, the Overload Protection Type will be “continuous constant current limiting”.
Fig. 5.1 Insert the CN3
Overload Protection Type : constant current limiting with delay shutdown after 5 seconds
Fig. 5.2 Remove the CN3
Overload Protection Type : constant current limiting
- Current Sharing with Remote Sense
RSP-3000 has the built-in active current sharing function and can be connected in parallel, up to 3 units, to provide higher output power as exhibited below:- The power supplies should be paralleled using short and large diameter wiring and then connected to the load.
- Difference of output voltages among parallel units should be less than 0.2V.
- The total output current must not exceed the value determined by the following equation:
- Maximum output current at parallel operation (Rated current per unit) X (Number of unit) x0.9
- When the total output current is less than 3% of the total rated current, or say (3% of Rated current per unit) (Number of unit) the current shared among units may not be fully balanced.
- When remote sensing is used in parallel operation, the sensing wire must be connected only to the master unit
- Sense lines should be twisted in pairs to minimize noise pick-up.
- +S,-S CS and on CN1 or CN2are connected mutually in parallel.
- Under parallel operation, the “output voltage programming” function is not available
- Three Phase Connect
Users can exploit three units of RSP-3000(unit 1 ,unit 2,unit 3) to work with 3 power system. Please refer to following diagrams ψ for configuration.- FIG. A: 3 3W 220VAC SYSTEM ψ
- FIG. B: 3 4W 220/380VAC SYSTEM ψ
- FIG. C: 3 W 190/110VAC SYSTEM ψ4
- FIG. A: 3 3W 220VAC SYSTEM ψ
Mechanical Specification
(Unit: mm , tolerance 0.5mm)
Case No.982B
Mounting Instruction
Hole No. | Recommended Screw Size | MAX. Penetration Depth L | Recommended mounting torque |
1 | M4 | 5mm | 7~10Kgf-cm |
- Control Pin No. Assignment : HRS DF11-8DP-2DS or equivalent (CN1,CN2)
Mating Housing HRS DF11-8DS or equivalent Terminal HRS DF11-**SC or equivalent - CN1 and CN2 are connected internally.
Pin No. Function Description 1 RCG Remote ON-OFF Ground 2 RC Remote ON-OFF 3 PV Connection for output voltage programming 4 PS Reference Voltage Terminal 5,7 -S Negative sensing for remote sense 6 CS(Current Share) Current Share 8 +S Positive sensing for remote sense - Control Pin No. Assignment : HRS DF11-10DP-2DS or equivalent (CN3)
Mating Housing HRS DF11-10DS or equivalent Terminal HRS DF11-**SC or equivalent Pin No. Function Description 1 P OK GND Power OK Ground 2 P OK Power OK Signal (Relay Contact) 3 P OK GND2 Power OK Ground 4 P OK2 Power OK Signal (TTL Signal) 5 RCG Remote ON-OFF Ground 6 RC Remote ON-OFF 7 AUXG Auxiliary Ground 8 AUX Auxiliary Output 9 OLP Overload(OLP) type select 10 OL-SD - AC Input Terminal Pin No. Assignment
Pin No. Assignment Diagram Maximum mounting torque 1 AC/L 18Kgf-cm 2 AC/N 3 FG
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
User’s Manual
Symbols
- Industrial
- Automate
- Telecom
- Network
- EV
Downloaded from Arrow.com.
Documents / Resources
![]() |
MEAN WELL RSP-3000 Series Power Supply with Single Output [pdf] Installation Guide RSP-3000-12, RSP-3000-24, RSP-3000-48, RSP-3000 Series Power Supply with Single Output, RSP-3000 Series, Power Supply with Single Output, Supply with Single Output, Single Output, Output |