MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter Owner’s Manual

MEAN WELL logo

100W Railway Single Output DC-DC Converter

RSD-100 series


User’s Manual
MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - QR Code

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter

■ GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

■ Features :
  • Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
  • 2:1 wide input range
  • Protections: Short circuit / Overload / Over voltage / Input reverse polarity
  • 4000VDC I/O isolation
  • Cooling by free air convection
  • Half encapsulated
  • Built-in constant current limiting circuit
  • 1U low profile 36mm
  • All using 105°C long life electrolytic capacitors
  • LED indicator for power on
  • 100% full load burn-in test
  • 3 years warranty

MEAN WELL - C RU US              Conformity declaration Icon 1              EAC Icon 4         Mean Well - CB      CE Icon 8    UKCA Icon
UL62368-1     AS/NZS62368-1    TPTC004    IEC62368-1

SPECIFICATION
MODEL RSD-100B-5 RSD-100B-12 RSD-100B-24
OUTPUT DC VOLTAGE 5V 12V 24V
RATED CURRENT 20A 8.4A 4.2A
CURRENT RANGE 0 ~ 20A 0 ~ 8.4A 0 ~ 4.2A
RATED POWER 100W 100.8W 100.8W
RIPPLE & NOISE (max.) 

Note.2

100mVp-p 120mVp-p 150mVp-p
VOLTAGE TOLERANCE 

Note.3

±2.0% ±2.0% ±2.0%
LINE REGULATION ±0.5% ±0.3% ±0.2%
LOAD REGULATION ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME 800ms, 50ms at full load
HOLD UP TIME (Typ.) Please refer to page 3 Hold up Time( Load de-rating curve )
INPUT VOLTAGE RANGE CONTINUOUS 16.8 ~ 31.2VDC
1 SEC. 14.4 ~ 33.6VDC
EFFICIENCY (Typ.) 88% 89% 89%
DC CURRENT (Typ.) 4.8A/24V 4.8A/24V 4.8A/24V
INRUSH CURRENT (Typ.) 30A/24VDC
INTERRUPTION OF VOLTAGE SUPPLY EN50155:2007-B/C- type comply with S1 level @ full load, comply with S2 level @ 70% load ; D-type comply with S2 level @ full load
EN50155:2017-Comply with S1 level
PROTECTION OVERLOAD 105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 5.75 ~ 7V 13.8 ~ 16.2V 27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT WORKING TEMP. -40 ~ +55 (no derating) ; +70 @ 60% load by free air convection ; +70 no derating with external base plate, TX class compliance
WORKING HUMIDITY 5 ~ 95% RH non-condensing
STORAGE TEMP. -40 ~ +85℃
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
OPERATING ALTITUDE 5000 meters
SAFETY & EMC (Note 5) SAFETY STANDARDS IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1
WITHSTAND VOLTAGE I/P-O/P:4KVDC   I/P-FG:2.5KVDC   O/P-FG:2.5KVDC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Conduction Emission: Class A, Radiation Emission: Class B, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8, EN55035, light industry level, BS EN/ EAC TP TC 020
RAILWAY STANDARD BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC BS EN/ ; EN45545-2 for fire protection
OTHERS MTBF 2446.2K hrs min.   Telcordia SR-332 (Bellcore) ; 254.2K hrs min.   MIL-HDBK-217F (25℃)  
DIMENSION 161*68*36mm (L*W*H)
PACKING 0.563Kg; 24pcs/14.5Kg/0.91CUFT
NOTE
  1. All parameters NOT specially mentioned are measured at 24,48,110VDC input, rated load and 25 of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSD-100-5 / -12)
  5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

MODEL RSD-100C-5 RSD-100C-12 RSD-100C-24
OUTPUT DC VOLTAGE 5V 12V 24V
RATED CURRENT 20A 8.4A 4.2A
CURRENT RANGE 0 ~ 20A 0 ~ 8.4A 0 ~ 4.2A
RATED POWER 100W 100.8W 100.8W
RIPPLE & NOISE (max.) 

Note.2

100mVp-p 120mVp-p 150mVp-p
VOLTAGE TOLERANCE 

Note.3

±2.0% ±2.0% ±2.0%
LINE REGULATION ±0.5% ±0.3% ±0.2%
LOAD REGULATION ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME 800ms, 50ms at full load
HOLD UP TIME (Typ.) Please refer to page 3 Hold up Time( Load de-rating curve )
INPUT VOLTAGE RANGE CONTINUOUS 33.6 ~ 62.4VDC
1 SEC. 28.8 ~ 67.2VDC
EFFICIENCY (Typ.) 89% 91% 91%
DC CURRENT (Typ.) 2.4A/48V 2.4A/48V 2.4A/48V
INRUSH CURRENT (Typ.) 30A/48VDC
INTERRUPTION OF VOLTAGE SUPPLY EN50155:2007-B/C- type comply with S1 level @ full load, comply with S2 level @ 70% load ; D-type comply with S2 level @ full load
EN50155:2017-Comply with S1 level
PROTECTION OVERLOAD 105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 5.75 ~ 7V 13.8 ~ 16.2V 27.6 ~ 32.4v
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT WORKING TEMP. -40 ~ +55 (no derating) ; +70 @ 60% load by free air convection ; +70 no derating with external base plate, TX class compliance
WORKING HUMIDITY 5 ~ 95% RH non-condensing
STORAGE TEMP. -40 ~ +85℃
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
OPERATING ALTITUDE 5000 meters
SAFETY & EMC (Note 5) SAFETY STANDARDS IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1
WITHSTAND VOLTAGE I/P-O/P:4KVDC   I/P-FG:2.5KVDC   O/P-FG:2.5KVDC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Conduction Emission: Class A, Radiation Emission: Class B, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8, EN55035, light industry level, BS EN/ EAC TP TC 020
RAILWAY STANDARD BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC BS EN/ ; EN45545-2 for fire protection
OTHERS MTBF 2446.2K hrs min.   Telcordia SR-332 (Bellcore) ; 254.2K hrs min.   MIL-HDBK-217F (25℃)  
DIMENSION 161*68*36mm (L*W*H)
PACKING 0.563Kg; 24pcs/14.5Kg/0.91CUFT
NOTE
  1. All parameters NOT specially mentioned are measured at 24,48,110VDC input, rated load and 25 of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSD-100-5 / -12)
  5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).

※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

MODEL RSD-100D-5 RSD-100D-12 RSD-100D-24
OUTPUT DC VOLTAGE 5V 12V 24V
RATED CURRENT 20A 8.4A 4.2A
CURRENT RANGE 0 ~ 20A 0 ~ 8.4A 0 ~ 4.2A
RATED POWER 100W 100.8W 100.8W
RIPPLE & NOISE (max.) 

Note.2

100mVp-p 120mVp-p 150mVp-p
VOLTAGE TOLERANCE 

Note.3

±2.0% ±2.0% ±2.0%
LINE REGULATION ±0.5% ±0.2% ±0.2%
LOAD REGULATION ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME 800ms, 50ms at full load
HOLD UP TIME (Typ.) Please refer to page 3 Hold up Time( Load de-rating curve )
INPUT VOLTAGE RANGE CONTINUOUS 67.2 ~ 143VDC
1 SEC. 57.6 ~ 154VDC
EFFICIENCY (Typ.)  89.5%  91% 90%
DC CURRENT (Typ.) 1.2A/110V 1.2A/110V 1.2A/110V
INRUSH CURRENT (Typ.) 30A/110VDC
INTERRUPTION OF VOLTAGE SUPPLY EN50155:2007-B/C- type comply with S1 level @ full load, comply with S2 level @ 70% load ; D-type comply with S2 level @ full load
EN50155:2017-Comply with S1 level
PROTECTION OVERLOAD 105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE  5.75 ~ 7V 13.8 ~ 16.2V 27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT WORKING TEMP. -40 ~ +55 (no derating) ; +70 @ 60% load by free air convection ; +70 no derating with external base plate, TX class compliance
WORKING HUMIDITY 5 ~ 95% RH non-condensing
STORAGE TEMP. -40 ~ +85℃
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
OPERATING ALTITUDE 5000 meters
SAFETY & EMC (Note 5) SAFETY STANDARDS IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1
WITHSTAND VOLTAGE I/P-O/P:4KVDC   I/P-FG:2.5KVDC   O/P-FG:2.5KVDC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Conduction Emission: Class A, Radiation Emission: Class B, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8, EN55035, light industry level, BS EN/ EAC TP TC 020
RAILWAY STANDARD BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC BS EN/ ; EN45545-2 for fire protection
OTHERS MTBF 2446.2K hrs min.   Telcordia SR-332 (Bellcore) ; 254.2K hrs min.   MIL-HDBK-217F (25℃)  
DIMENSION 161*68*36mm (L*W*H)
PACKING 0.563Kg; 24pcs/14.5Kg/0.91CUFT
NOTE
  1. All parameters NOT specially mentioned are measured at 24,48,110VDC input, rated load and 25 of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSD-100-5 / -12)
  5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).

※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

■ Mechanical Specification

(Unit: mm , tolerance ± 1mm)

Case No.999A

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a1

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a2

  • (tc) : Max. Case Temperature

Input Terminal Pin No. Assignment :

Pin No. Assignment
1 DC INPUT V+
2 DC INPUT V-
3 FG Earthing symbol 5

Output Terminal Pin No. Assignment :

Pin No. Assignment
1 DC OUTPUT -V
2 DC OUTPUT +V
■ Block Diagram

fosc : 130KHz

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a3

■ Input Fuse

There is one fuse connected in series to the positive input line, which is used to protect against abnormal surge. Fuse specifications of each model are shown as below.

Type Fuse Type Reference and Rating
B Time-Lag Conquer UDA-A, 10A, 250V
C Time-Lag Conquer UDA-A, 5A, 250V
D Time-Lag Conquer UDA-A, 3.15A, 250V
■ Input Reverse Polarity Protection

There is a MOSFET connected in series to the negative input line. If the input polarity is connected reversely, the MOSFET opens and there will be no output to protect the unit.

■ Input Range and Transient Ability

The series has a wide range input capability. Within 30% of rated input voltage, it can be executed at full-load operation and operate properly; with 40% of rated input voltage, it can withstand that for 1 second.

■ Input Under-Voltage Protection

If input voltage drops below Vimin, the internal control IC shuts down and there is no output voltage. It recovers automatically when input voltage reaches above Vimin, please refer to the cruve below.

RSD-100B-24

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a4

RSD-100C-24

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a5

RSD-100D-24

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a6

■ Inrush Current

Inrush current is suppressed by a resistor during the initial start-up, and then the resistor is bypassed by a MOSFET to reduce power consumption after accomplishing the start-up.

■ Hold-up Time
  • EN50155: 2007 version – D type is in compliance with S2 level, while B and C types are in compliance with S1 level at full load output condition. To fulfil the requirements of S2 level, B and C types require de-rating their output load to 70%, please refer to the curve diagrams below.

RSD-100B-5

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a7

RSD-100B-12

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a8

RSD-100B-24

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a9

RSD-100C-5

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a10

RSD-100C-12

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a11

RSD-100C-24

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a12

  • EN50155: 2017 version – Comply with S1 level
■ Output Voltage Adjustment

This function is optional, which the standard product does not have it. If you do need the function, please contact MW for details.

■ Efficiency vs Load & Vin Curve

The efficiency vs load & Vin curves of each model are shown as below.

RSD-100B-5

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a13

RSD-100B-12

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a14

RSD-100B-24

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a15

RSD-100C-5

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a16

RSD-100C-12

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a17

RSD-100C-24

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a18

RSD-100D-5

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a19

RSD-100D-12

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a20

RSD-100D-24

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a21

■ Parallel and Series Connection

A. Operation in Parallel

Since RSD-100 series don’t have built-in parallel circuit, it can only use external circuits to achieve the redundant operation but not increase the current rating.

1. Add a diode at the positive-output of each power supply (as shown as below), the current rating of the diode should be larger than the maximum output current rating and attached to a suitable heat sink. This is only for redundant use (increase the reliability of the system) and users have to check suitability of the circuit by themselves.

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a22

2.When using S.P.S. in parallel connection, the leakage current will increase at the same time. This could pose as a shock hazard for the user. So please contact the supplier if you have this kind of application.

B. Operation in Series

RSD-100 can be operated in series. Here are the methods of doing it:

1. Positive and negative terminals are connected as shown as below. According to the connection, you can get the positive and negative output voltages for your loads.

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a23

2. Increase the output voltage (current does not change). Because RSD-100 series have no reverse blocking diode in the unit, you should add an external blocking diode to prevent the damage of every unit while starting up. The voltage rating of the external diode should be larger than V1+V2 (as shown as below).

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a24

■ Overload Protection

If the output draw up to 105~135% of its output power rating, the converter will go into overload protection which is constant current mode. After the faulty condition is removed, it will recover automatically. Please refer to the diagram below for the detail operation characteristic. Please note that it’s not suitable to operate within the overload region continuously, or it may cause to over temperature and reduce the life of the power supply unit or even damage it.

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a32

  1. Overload region
■ Over Voltage Protection

The converter shuts off to protect itself when the output voltage drawn exceeds 115~140% of its output rating. It must be repowered on to recover.

■ LED Indicator

Equipped with a built-in LED indicator, the converter provides an easy way for users to check its condition through the LED indicator.

Green : normal operation; No signal: no power or failure.

■ Derating Curve

a. Single unit operation

If the unit has no iron plate mounted on its bottom, the maximum ambient temperature for the unit will be 55°C as operating under full load condition. It requires de-rating output current when ambient temperature is between 55-70°C, please refer to the de-rating curve as below.

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a26 MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a27

Suitable installation methods are shown as below. Since RSD-100 is a semi-potted model, its thermal performances for the following installation methods are similar and share the same derating curve.

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a28

b. Operate with additional iron plate

If it is necessary to fulfil the requirements of EN50155 TX level that operate the unit fully-loaded at 70°C, RSD-100 series must be installed onto an iron plate on the bottom. The size of the suggested iron plate is shown as below. In order for optimal thermal performance, the iron plate must have an even & smooth surface and RSD-100 series must be firmly mounted at the center of the iron plate.

Unit:mm

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a29

The load vs ambient temperature curve is shown as below.

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a30

Suitable installation methods are shown as below. Since RSD-100 is a semi-potted model, its thermal performances for the following installation methods are similar and share the same derating curve.

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter - a31

  1. iron plate
■ Immunity to Environmental Conditions
Test method Standard Test conditions Status
Cooling Test EN 50155 section 12.2.3 (Column 2, Class TX)
EN 60068-2-1
Temperature: -40℃
Dwell Time: 2 hrs/cycle
No damage
Dry Heat Test EN 50155 section 12.2.4 (Column 2, Class TX)
EN 50155 section 12.2.4 (Column 3, Class TX & Column 4, Class TX)
EN 60068-2-2
Temperature: 70°C / 85°C
Duration: 6 hrs / 10min
PASS
Damp Heat Test, Cyclic EN 50155 section 12.2.5
EN 60068-2-30
Temperature: 25°C ~55°C
Humidity: 90%~100% RH
Duration: 48 hrs
PASS
Vibration Test EN 50155 section 12.2.11
EN 61373
Temperature: 19℃
Humidity: 65%
Duration: 10 mins
PASS
Increased Vibration Test EN 50155 section 12.2.11
EN 61373
Temperature: 19℃
Humidity: 65%
Duration: 5 hrs
PASS
Shock Test EN 50155 section 12.2.11
EN 61373
Temperature: 21 ± 3℃
Humidity: 65 5% ±
Duration: 30ms*18
PASS
Low Temperature Storage Test EN 50155 section 12.2.3 (Column 2, Class TX)
EN 60068-2-1
Temperature: -40℃
Dwell Time: 16 hrs
PASS
Salt Mist Test EN 50155 section 12.2.10 (Class ST4) Temperature: 35℃ ± 2℃
Duration: 96 hrs
PASS
■ EN45545-2 Fire Test Conditions
Test Items Hazard Level
Items Standard HL1 HL2 HL3
R22 Oxygen index test EN 45545-2:2013
EN ISO 4589-2:1996
PASS PASS PASS
Smoke density test EN 45545-2:2013
EN ISO 5659-2:2006
PASS PASS PASS
Smoke toxicity test EN 45545-2:2013
NF X70-100:2006
PASS PASS PASS
R24 Oxygen index test EN 45545-2:2013
EN ISO 4589-2:1996
PASS PASS PASS
R25 Glow-wire test EN 45545-2:2013
EN 60695-2-11:2000
PASS PASS PASS
R26 Vertical flame test EN 45545-2:2013
EN 60695-11:2003
PASS PASS PASS

File Name:RSD-100-SPEC 2024-11-22

Downloaded from Arrow.com.

Documents / Resources

MEAN WELL RSD-100B-5 100W Railway Single Output DC-DC Converter [pdf] Owner's Manual
RSD-100B-5, RSD-100B-12, RSD-100B-24, RSD-100C-5, RSD-100C-12, RSD-100C-24, RSD-100D-5, RSD-100D-12, RSD-100D-24, RSD-100B-5 100W Railway Single Output DC-DC Converter, RSD-100B-5, 100W Railway Single Output DC-DC Converter, Railway Single Output DC-DC Converter, Single Output DC-DC Converter, Output DC-DC Converter, DC-DC Converter