Features

  • Universal AC input / Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • LED indicator for power on
  • 100% full load burn-in test
  • All using 105°C long life electrolytic capacitors
  • Withstand 300VAC surge input for 5 second
  • High operating temperature up to 70°C
  • Withstand 5G vibration test
  • High efficiency, long life and high reliability
  • 3 years warranty

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

SPECIFICATION

MODEL RD-50A RD-50B
 

 

 

 

 

 

 

 

OUTPUT

OUTPUT NUMBER CH1 CH2 CH1 CH2
DC VOLTAGE 5V 12V 5V 24V
RATED CURRENT 6A 2A 4A 1.4A
CURRENT RANGE                                                 Note.3 0 ~ 6A 0 ~ 3A 0 ~ 6A 0 ~ 2A
RATED POWER 54W 53.6W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 150mVp-p
VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 ±2.0% ±7.0% ±2.0% ±8%
LINE REGULATION          Note.4 ±0.5% ±1.5% ±0.5% ±1.5%
LOAD REGULATION        Note.5 ±0.5% ±3.0% ±0.5% ±3.0%
SETUP, RISE TIME 500ms, 20ms/230VAC           1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 60ms/230VAC           10ms/115VAC at full load
 

 

 

INPUT

VOLTAGE RANGE 88 ~ 264VAC           125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY(Typ.) 78% 79%
AC CURRENT (Typ.) 1.3A/115VAC            0.8A/230VAC
INRUSH CURRENT (Typ.) COLD START 48A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
 

 

PROTECTION

 

OVERLOAD

110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
 

OVER VOLTAGE

CH1: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
 

 

 

ENVIRONMENT

WORKING TEMP. -25 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)on +5V output
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
 

SAFETY & EMC

(Note 6)

SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, BIS IS 13252(Part 1):2010/IEC 60950-1:2005, EAC TP TC 004 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
 

OTHERS

MTBF 2981.9K hrs min.       Telcordia SR-332 (Bellcore) ; 594.2K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION 99*97*36mm (L*W*H)
PACKING 0.41Kg; 45pcs/19.5Kg/0.94CUFT
NOTE
  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation, when multi-channel output, it is recommended that CH1 load > 10%.
  4. Line regulation is measured from low line to high line at rated load.
  5. Load regulation is measured from 0% to 100% rated load.
  6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on   a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN-WELL-RD-50-Series-Dual-Output-Switching-Power-Supply-fig-3

Terminal Pin No. Assignment

Pin No. Assignment Pin No. Assignment
1 AC/L 4,6 DC OUTPUT COM
2 AC/N 5 DC OUTPUT +V2
3 FG MEAN-WELL-RD-50-Series-Dual-Output-Switching-Power-Supply-fig-7 7 DC OUTPUT +V1

Block Diagram

fosc : 60KHz

MEAN-WELL-RD-50-Series-Dual-Output-Switching-Power-Supply-fig-4

Derating Curve

MEAN-WELL-RD-50-Series-Dual-Output-Switching-Power-Supply-fig-5

Output Derating VS Input Voltage

MEAN-WELL-RD-50-Series-Dual-Output-Switching-Power-Supply-fig-6

User’s Manual

MEAN-WELL-RD-50-Series-Dual-Output-Switching-Power-Supply-fig-1

MEAN-WELL-RD-50-Series-Dual-Output-Switching-Power-Supply-fig-2

Documents / Resources

MEAN WELL RD-50 Series Dual Output Switching Power Supply [pdf] Owner's Manual
RD-50 Series Dual Output Switching Power Supply, RD-50 Series, Dual Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply

References

Leave a comment

Your email address will not be published. Required fields are marked *