ERPF-400-48 400W Single Output Switching Power Supply
“
Specifications:
- Model: ERPF-400-12, ERPF-400-24, ERPF-400-48
- DC Voltage: 12V, 24V, 48V
- Rated Current: 30A, 16.7A, 8.3A
- Rated Power: 360W, 400.8W, 398.4W
- Ripple & Noise (max.): 150mVp-p, 150mVp-p, 240mVp-p
- Output Voltage Adj. Range: 10.8 ~ 13.2V
- Line Regulation
- Load Regulation
- Setup, Rise Time: 2000ms, 100ms/230VAC; 3000ms, 100ms/115VAC at
full load - Hold Up Time (Typ.): 10ms/230VAC; 10ms/115VAC at full load
- Voltage Range: 90 ~ 264VAC, 127 ~ 370VDC
- Frequency Range: 47 ~ 63Hz
- Power Factor (Typ.): PF0.95/230VAC, PF0.98/115VAC
- Efficiency (Typ.): 89%, 90%, 91%
- AC Current (Typ.): 2.5A/230VAC, 3A/115VAC
- Inrush Current (Typ.): Cold start 45A/115VAC, 90A/230VAC
Product Usage Instructions:
1. Installation:
1. Ensure the power supply is disconnected from the power source
before installation.
2. Connect the input terminals according to the voltage
requirements specified in the manual.
2. Powering On:
1. Once properly installed, connect the power supply to the
appropriate power source.
2. Turn on the power supply using the designated switch or
button.
3. Adjusting Output Voltage:
1. Use the provided adjustment range to set the output voltage
within the specified range if necessary.
4. Safety Precautions:
1. Do not attempt to open or modify the power supply unit as it
may result in electric shock or damage.
2. Keep the power supply away from moisture or heat sources to
prevent malfunctions.
Frequently Asked Questions (FAQ):
Q: Can the power supply be used with both AC and DC input?
A: Yes, the power supply has a wide input voltage range suitable
for both AC and DC inputs.
Q: What is the typical efficiency of this power supply?
A: The typical efficiency ranges from 89% to 91% depending on
the model.
Q: How do I determine the appropriate model for my
application?
A: Choose the model based on your required voltage and current
specifications as outlined in the user manual.
“`
400W Single Output Switching Power Supply
ERPF-400 series
User’s Manual
IS 13252(Part 1)/ IEC 60950-1
THOMAS SAMUEL
THOMAS SAMUEL
R-41070483
(for 12,24 only )
Bauar t gepruft Sicherheit
egelma ge od o s be wac g www. tuv.com ID 2000000000
File Name:ERPF-400-SPEC 2024-01-08
400W Single Output Switching Power Supply
ERPF-400 series
SPECIFICATION
MODEL
ERPF-400-12
ERPF-400-24
ERPF-400-48
DC VOLTAGE
12V
24V
48V
RATED CURRENT
30A
16.7A
8.3A
CURRENT RANGE Note.5 0 ~ 30A
0 ~ 16.7A
0 ~ 8.3A
RATED POWER
360W
400.8W
398.4W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
240mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
10.8 ~ 13.2V
VOLTAGE TOLERANCE Note.3 ±1.0%
LINE REGULATION
±0.5%
LOAD REGULATION
±0.5%
21.6 ~ 26.4V ±1.0% ±0.5% ±0.5%
43.2 ~ 52.8V ±1.0% ±0.5% ±0.5%
SETUP, RISE TIME
2000ms, 100ms/230VAC; 3000ms, 100ms/115VAC at full load
HOLD UP TIME (Typ.)
10ms/230VAC; 10ms/115VAC at full load
VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF0.95/230VAC, PF0.98/115VAC
INPUT
EFFICIENCY (Typ.)
89%
90%
91%
AC CURRENT (Typ.)
2.5A/230VAC 3A/115VAC
INRUSH CURRENT (Typ.)
cold start 45A/115VAC, 90A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
OVER LOAD SHORT CIRCUIT PROTECTION OVER VOLTAGE
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Constant current limiting, recovers automatically after fault condition is removed
13.8 ~ 16.2V
27.6 ~ 32.4V
55.2 ~ 64.8V
Protection type :Shut down O/P voltage, re-power on to recover
OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION
Shut down O/P voltage, recovers automatically after temperature goes down -30 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -30 ~ +85, 10 ~ 95% RH ±0.1%/ (0 ~ 35) 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC (Note.6)
ISOLATION RESISTANCE EMC EMISSION
UL60950-1,IEC/BS EN/EN62368-1, GB 4943.1, EAC TP TC 004, IS13252(Part1)(for 12,24 only) approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25/ 70% RH
Compliance to BS EN/EN55032 (CISPR32) class A, GB17625.1,GB/T 9254.1; BS EN/EN61000-3-2; BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035; light industry level, EAC TP TC 020
OTHERS NOTE
MTBF
1981.2K hrs min. Telcordia SR-332 (Bellcore) 233.4Khrs min. MIL-HDBK-217F (25)
DIMENSION
220.4*130*48mm (L*W*H)
PACKING
1.1Kg; 9pcs / 11Kg / 0.63CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the static characteristics for more details. 5. Please refer to “Static Characteristics”. 6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 450mm*450mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
File Name:ERPF-400-SPEC 2024-01-08
400W Single Output Switching Power Supply
9.5
8
Mechanical Specification
200
LED +V ADJ.
9 8 7 6 5 4 3 2 1
8.6
8 20.4
65 130
ERPF-400 series
Case No.230 Unit:mm
3
40
Terminal Pin No. assignment :
Pin No. Assignment Pin No.
1
AC/L
4~6
2
AC/N
7~9
3
FG
Assignment Max mounting torque DC OUTPUT +V DC OUTPUT -V 8Kgf-cm
5
Block Diagram
I/P
EMI FILTER
FG
Derating Curve
PFC CIRCUIT
POWER SWITCHING
RECTIFIERS &
FILTER
O.L.P. O.T.P.
PWM&PFC CONTROL
O.V.P.
DETECTION CIRCUIT
Static Characteristics
fosc : 80KHz
+V -V
LOAD (%) LOAD (%)
100
80
60 50 40
20
-30 -10
0
10
20
30 35 40
50
60 (VERTICAL)
AMBIENT TEMPERATURE ()
100
75 65 50
25
90
100
150
200
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:ERPF-400-SPEC 2024-01-08
400W Single Output Switching Power Supply
ERPF-400 series
Installation
File Name:ERPF-400-SPEC 2024-01-08
Documents / Resources
![]() |
MEAN WELL ERPF-400-48 400W Single Output Switching Power Supply [pdf] Owner's Manual ERPF-400-12, ERPF-400-24, ERPF-400-48, ERPF-400-48 400W Single Output Switching Power Supply, ERPF-400-48, 400W Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply |