Specifications:

  • Model: ERPF-400-12, ERPF-400-24, ERPF-400-48
  • DC Voltage: 12V, 24V, 48V
  • Rated Current: 30A, 16.7A, 8.3A
  • Rated Power: 360W, 400.8W, 398.4W
  • Ripple & Noise (max.): 150mVp-p, 150mVp-p, 240mVp-p
  • Output Voltage Adj. Range: 10.8 ~ 13.2V
  • Line Regulation
  • Load Regulation
  • Setup, Rise Time: 2000ms, 100ms/230VAC; 3000ms, 100ms/115VAC at
    full load
  • Hold Up Time (Typ.): 10ms/230VAC; 10ms/115VAC at full load
  • Voltage Range: 90 ~ 264VAC, 127 ~ 370VDC
  • Frequency Range: 47 ~ 63Hz
  • Power Factor (Typ.): PF0.95/230VAC, PF0.98/115VAC
  • Efficiency (Typ.): 89%, 90%, 91%
  • AC Current (Typ.): 2.5A/230VAC, 3A/115VAC
  • Inrush Current (Typ.): Cold start 45A/115VAC, 90A/230VAC

Product Usage Instructions:

1. Installation:

1. Ensure the power supply is disconnected from the power source
before installation.

2. Connect the input terminals according to the voltage
requirements specified in the manual.

2. Powering On:

1. Once properly installed, connect the power supply to the
appropriate power source.

2. Turn on the power supply using the designated switch or
button.

3. Adjusting Output Voltage:

1. Use the provided adjustment range to set the output voltage
within the specified range if necessary.

4. Safety Precautions:

1. Do not attempt to open or modify the power supply unit as it
may result in electric shock or damage.

2. Keep the power supply away from moisture or heat sources to
prevent malfunctions.

Frequently Asked Questions (FAQ):

Q: Can the power supply be used with both AC and DC input?

A: Yes, the power supply has a wide input voltage range suitable
for both AC and DC inputs.

Q: What is the typical efficiency of this power supply?

A: The typical efficiency ranges from 89% to 91% depending on
the model.

Q: How do I determine the appropriate model for my
application?

A: Choose the model based on your required voltage and current
specifications as outlined in the user manual.

“`

400W Single Output Switching Power Supply

ERPF-400 series
User’s Manual

IS 13252(Part 1)/ IEC 60950-1

THOMAS SAMUEL

THOMAS SAMUEL

R-41070483
(for 12,24 only )

Bauar t gepruft Sicherheit
egelma ge od o s be wac g www. tuv.com ID 2000000000

File Name:ERPF-400-SPEC 2024-01-08

400W Single Output Switching Power Supply

ERPF-400 series

SPECIFICATION

MODEL

ERPF-400-12

ERPF-400-24

ERPF-400-48

DC VOLTAGE

12V

24V

48V

RATED CURRENT

30A

16.7A

8.3A

CURRENT RANGE Note.5 0 ~ 30A

0 ~ 16.7A

0 ~ 8.3A

RATED POWER

360W

400.8W

398.4W

RIPPLE & NOISE (max.) Note.2 150mVp-p

150mVp-p

240mVp-p

OUTPUT

VOLTAGE ADJ. RANGE

10.8 ~ 13.2V

VOLTAGE TOLERANCE Note.3 ±1.0%

LINE REGULATION

±0.5%

LOAD REGULATION

±0.5%

21.6 ~ 26.4V ±1.0% ±0.5% ±0.5%

43.2 ~ 52.8V ±1.0% ±0.5% ±0.5%

SETUP, RISE TIME

2000ms, 100ms/230VAC; 3000ms, 100ms/115VAC at full load

HOLD UP TIME (Typ.)

10ms/230VAC; 10ms/115VAC at full load

VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)

PF0.95/230VAC, PF0.98/115VAC

INPUT

EFFICIENCY (Typ.)

89%

90%

91%

AC CURRENT (Typ.)

2.5A/230VAC 3A/115VAC

INRUSH CURRENT (Typ.)

cold start 45A/115VAC, 90A/230VAC

LEAKAGE CURRENT

<1mA / 240VAC

OVER LOAD SHORT CIRCUIT PROTECTION OVER VOLTAGE

105 ~ 135% rated output power

Protection type : Constant current limiting, recovers automatically after fault condition is removed

Protection type : Constant current limiting, recovers automatically after fault condition is removed

13.8 ~ 16.2V

27.6 ~ 32.4V

55.2 ~ 64.8V

Protection type :Shut down O/P voltage, re-power on to recover

OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION

Shut down O/P voltage, recovers automatically after temperature goes down -30 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -30 ~ +85, 10 ~ 95% RH ±0.1%/ (0 ~ 35) 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY STANDARDS

SAFETY & WITHSTAND VOLTAGE

EMC (Note.6)

ISOLATION RESISTANCE EMC EMISSION

UL60950-1,IEC/BS EN/EN62368-1, GB 4943.1, EAC TP TC 004, IS13252(Part1)(for 12,24 only) approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25/ 70% RH
Compliance to BS EN/EN55032 (CISPR32) class A, GB17625.1,GB/T 9254.1; BS EN/EN61000-3-2; BS EN/EN61000-3-3, EAC TP TC 020

EMC IMMUNITY

Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035; light industry level, EAC TP TC 020

OTHERS NOTE

MTBF

1981.2K hrs min. Telcordia SR-332 (Bellcore) 233.4Khrs min. MIL-HDBK-217F (25)

DIMENSION

220.4*130*48mm (L*W*H)

PACKING

1.1Kg; 9pcs / 11Kg / 0.63CUFT

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the static characteristics for more details. 5. Please refer to “Static Characteristics”. 6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 450mm*450mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)

Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

File Name:ERPF-400-SPEC 2024-01-08

400W Single Output Switching Power Supply

9.5

8

Mechanical Specification
200
LED +V ADJ.
9 8 7 6 5 4 3 2 1

8.6
8 20.4

65 130

ERPF-400 series
Case No.230 Unit:mm

3

40

Terminal Pin No. assignment :

Pin No. Assignment Pin No.

1

AC/L

4~6

2

AC/N

7~9

3

FG

Assignment Max mounting torque DC OUTPUT +V DC OUTPUT -V 8Kgf-cm

5

Block Diagram

I/P

EMI FILTER

FG

Derating Curve

PFC CIRCUIT

POWER SWITCHING

RECTIFIERS &
FILTER

O.L.P. O.T.P.

PWM&PFC CONTROL

O.V.P.
DETECTION CIRCUIT
Static Characteristics

fosc : 80KHz
+V -V

LOAD (%) LOAD (%)

100
80
60 50 40
20

-30 -10

0

10

20

30 35 40

50

60 (VERTICAL)

AMBIENT TEMPERATURE ()

100
75 65 50
25
90

100

150

200

240

264

INPUT VOLTAGE (VAC) 60Hz

File Name:ERPF-400-SPEC 2024-01-08

400W Single Output Switching Power Supply

ERPF-400 series

Installation

File Name:ERPF-400-SPEC 2024-01-08

Documents / Resources

MEAN WELL ERPF-400-48 400W Single Output Switching Power Supply [pdf] Owner's Manual
ERPF-400-12, ERPF-400-24, ERPF-400-48, ERPF-400-48 400W Single Output Switching Power Supply, ERPF-400-48, 400W Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply

References

Leave a comment

Your email address will not be published. Required fields are marked *