Features:

  • Universal AC input / Full range
  • Optional L-Bracket and cover
  • High efficiency up to 90%
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • 4″x2″ compact size
  • LED indicator for power on
  • No load power consumption<0.3W
  • Operating altitude up to 4000 meters
  • 3 years warranty

MEAN WELL EPS-45 Series 45W Single Output Switching Power Supply - QRhttps://www.meanwell.com/Upload/PDF/PCB_EN.pdfMEAN WELL EPS-45 Series 45W Single Output Switching Power Supply - icon

GTIN CODE

MW Search: https://www.meanwell.comIserviceGTIN.aspx
EPS-45-3.3 -C AIR INNOVATION MH-902 Clean Mist Top-Fill Sensa Touch Humidifier - symbol 1 =Blank.-C . Blank=PCB only. -C=Enclosed type

SPECIFICATION

MODEL EPS-45-3.❑ EPS-45-5❑ EPS-45-7.5❑ EPS-45-12❑ EPS-45-15❑ EPS-45-24❑ EPS-45-36❑ EPS-45-48❑
OUTPUT DC VOLTAGE 3.3V 5V 7.5V 12V 15V 21V 36V 48V
RATED CURRENT 8A BA 5.4A 3.75A 3A 1.9A 1.25A IA
CURRENT RANGE 0 -9A 0 -9A 0 -6A 0-42A 0 – 3.3A 0-2.1A 0-IAA 0-1.1A
RATED POWER 26.4W 40W 40. 5W 45W 45W 45.6W 45W 48W
PEAK LOAD(10sec.) Note.6 29.7W 45W 42W 50.4W 49.5W 50.4W 50AW 52.8W
RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVpp 100mVp-p 120mVp-p 150mVp-p 240mVp-p 280mVp-p 300mVp-p
VOLTAGE ADJ. RANGE 3.1 – 3.6V 4.75 – 5.5V 7.13-825V 10.8 – 13.5V 13.5 – 16.5V 21.6 – 2N 32.4 – 39.6V 43.2 – 521V
VOLTAGE TOLERANCE Note.3 ±3.0% ±2.0% ±2.0% ±2.0% ±2.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±13.5%
LOAD REGULATION ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME 1000ms. 5Orns1230VAC 2000ms. 50ms/115VAC at full load
HOLD UP TIME (Typ.) 50ms230VAC lEms/115VAC at full load
INPUT VOLTAGE RANGE Nole.5 90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/N(+), AC/L(-)]
FREQUENCY RANGE 47 -63Hz
EFFICIENCY (Typ.) 80% 182% 184% 187% 188% 189% 189% 190%
AC CURRENT (Typ.) 1.8A/115VAC I A/230VAC
INRUSH CURRENT (Typ.) COLD START 60A/230VAC
LEAKAGE CURRENT <2mA/240VAC
PROTECTION OVER LOAD 115 – 160% rated output pow
Protection type : Hiccup mode. recovers atamatically after fall condition is removed
OVER VOLTAGE 3.7 ∼ 4.45V 5.6 ∼ 6.75V 8.63 ∼ 10.1V 13.8 ∼ I6.2V 17.25 ∼ 20.25V 27.6 ∼ 32.4V 39.7 ∼ 46.8V 53.3 ∼ 64.8V
Protection type : Shut down oip voltage. re-power on to recover
EIMRIMMENT WORKING TEMP. -30 – +70°C (Refer lo output load derating curve)
WORKING HUMIDITY 20 – 93% RH non-condensing
STORAGE TEMP.. HUMIDITY 40∼ +85°C. 10∼ 95% RH
TEMP. COEFFICIENT ±0.03%/°C (0 – 50°C)
OPERATING ALTITUDE Note.7 4000 meters
VIBRATION 10 – 500Hz. 2G 10min./1cycle. period for 60min. each along X. Y. Z axes
SAFETY & EMC (Note 4) SAFETY STANDARDS UL62368-1. 11.IV BS EN/EN623138-1. EAC TP TC 004 approved
WITHSTAND VOLTAGE UP-O;P:3KVAC IIP.FO2KVAC OP-FG:0.5KVAC
 ISOLATION RESISTANCE VP-0/P. I/P-FG. 0/12-FG:100M Ohms / 500VDC/25°C/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B. BS EN/EN81000-3-2.-3. EAC TP TC 020
EMC IMMUNITY Compliance to BS EPPEN61000-4-2.3.4.5.6.8.11. BS EN/BMWS. heavy industry level. EAC TP TC 020
OTHERS MTBF 2981.8K hrs min. Telo:rdia SR-332 (Bellcore): 652.4K hrs me. MIL-HDBK-217F (25°C)
DIMENSION PCB:101.6*50.8*19mm (L*W*H); with optional CASE:103.41217mm (L*W*H)
PACKING PCB: 0.14Kg: Repos/ 14.5Kg/1.39CUFT; with optional CASE: 0.3Kg:45pcsl 14.5Kg0.63CUFT
NOTE 1. Al parameters NOT specially watered are meastrei at 230VAC input rated Iced and 25°C of amtient temperate.
2. Ripple & noise are neared at 20MHz of teniwiti by using a 12″ Misted pay/rare terminated with a 0.1ul& 47uf parallel capacitor.
3. Tolerance: imlutos set up taance. Ire regulation and load regulation
4. Dwatig may be needed under low iput voltage. Please check the static characteristics for more Maas.
5. 33% Cuty cycle mamun vain every 30 saccade, Average MN poser should not exceed the rated pear.
6. The poser suppty is ccrisklerei a component which MI be Metaled irto a RS equipment Al the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate wit 1mm cf thickness. The final equiprnent must be re-ccritmed that it still meets EMC directives. For guidance on how to perkan these EMC tests. please refer to “EMI testirg d ccrrponent pow swims.” (as amide on http://www.meanwell.com)
7. The ambient temperate deratig of 3.5°C /1000m with fatless models and of 5°C/1000m with fan models for operafrg allude higher than 2000m(6500ft).
MEAN WELL EPS-45 Series 45W Single Output Switching Power Supply - icon 10 Product lately Cisclaimer : For detailed irdormatin please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN WELL EPS-45 Series 45W Single Output Switching Power Supply - Mechanical

Block Diagram

MEAN WELL EPS-45 Series 45W Single Output Switching Power Supply - Diagram

Output Derating

MEAN WELL EPS-45 Series 45W Single Output Switching Power Supply - Output

Static Characteristics

MEAN WELL EPS-45 Series 45W Single Output Switching Power Supply - Characteristics

MEAN WELL logoFile Name:EPS-45-SPEC 2022-09-20
Downloaded from Arrow.com.

Documents / Resources

MEAN WELL EPS-45 Series 45W Single Output Switching Power Supply [pdf] Owner's Manual
EPS-45 Series 45W Single Output Switching Power Supply, EPS-45 Series, 45W Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply
MEAN WELL EPS-45 Series 45W Single Output Switching Power Supply [pdf] Owner's Manual
EPS-45-24, EPS-45 Series 45W Single Output Switching Power Supply, EPS-45 Series, EPS-45 Series Power Supply, 45W Single Output Switching Power Supply, 45W Power Supply, Single Output Switching Power Supply, Switching Power Supply, Single Output Power Supply, Power Supply
MEAN WELL EPS-45 Series 45W Single Output Switching Power Supply [pdf] Owner's Manual
EPS-45-12, EPS-45 Series 45W Single Output Switching Power Supply, EPS-45 Series, 45W Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply

References

Leave a comment

Your email address will not be published. Required fields are marked *