MEAN WELL APV-35 Series 35W Single Output Switching Power Supply
Product Information
Specifications:
- Model: APV-35-5, APV-35-12, APV-35-15, APV-35-24, APV-35-36
- Output Voltage: 5V, 12V, 15V, 24V, 36V
- Rated Current: 5A, 3A, 2.4A
- Rated Power: 25W, 36W
- Ripple & Noise: 120mVp-p, 150mVp-p
- Efficiency: 76.5%, 83%, 84%
- Operating Temperature: -30°C to 70°C
- Working Humidity: 20% to 90% RH non-condensing
- Safety Standards: UL8750, CSA-C22.2 No. 250.0-13, BIS IS15885, EAC TP TC 004, IP42, BS EN/EN 62368-1 Approved
- EMC Compliance: BS EN/EN55032, BS EN/EN61000-3-2 Class A, BS EN/EN61000-3-3
- Isolation Resistance: I/P-O/P:3KVAC I/P-O/P:>100M Ohms/500VDC
Product Usage Instructions
Installation:
- Ensure the input power source matches the voltage range specified (90 ~ 264VAC).
- Connect the output terminals to your device following the correct polarity (V+ and V-).
Operation:
- Power on the switching power supply using the AC/N and AC/L terminals.
- Monitor the load current to ensure it stays within the specified range for each model.
Safety Precautions:
- Do not exceed the maximum current and voltage ratings to prevent damage.
- Keep the power supply away from moisture and high temperatures to ensure proper operation.
FAQ:
- Q: What should I do if the power supply overheats?
A: Ensure proper ventilation around the power supply and reduce the load if necessary to prevent overheating. - Q: Can I use this power supply for LED lighting applications?
A: This product is not intended for LED lighting luminaire applications in the EU. Refer to the LPF/NPF/XLG series for such purposes.
User’s Manual
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx.
Features
- Constant voltage mode power supply
- Universal AC input / Full range
- Withstand 300VAC Surge input for 5 seconds
- Protections: Short circuit / Over load / Over voltage
- Fully isolated plastic case
- Cooling by free air convection
- Small and compact size
- IP42 design
- Class 2 power unit
- Pass LPS
- 100% full load burn-in test
- Low cost, high reliability
- Suitable for LED-related fixtures or appliances (such as LED Decoration or Advertisement devices) (Note.10)
- 2 years warranty.
SPECIFICATION
MODEL | APV-35-5 | APV-35-12 | APV-35-15 | APV-35-24 | APV-35-36 | |||
OUTPUT |
DC VOLTAGE | 5V | 12V | 15V | 24V | 36V | ||
RATED CURRENT | 5A | 3A | 2.4A | 1.5A | 1A | |||
CURRENT RANGE | 0 ~ 5A | 0 ~ 3A | 0 ~ 2.4A | 0 ~ 1.5A | 0 ~ 1A | |||
RATED POWER | 25W | 36W | 36W | 36W | 36W | |||
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | 150mVp-p | 150mVp-p | 180mVp-p | 180mVp-p | |||
VOLTAGE TOLERANCE Note.3 | ±5.0% | |||||||
LINE REGULATION | ±1.0% | |||||||
LOAD REGULATION | ±2.0% | |||||||
SETUP, RISE TIME | Note.6 | 1500ms, 40ms / 230VAC 1500ms,40ms / 115VAC at full load | ||||||
HOLD UP TIME (Typ.) | 20ms/230VAC 12ms/115VAC at full load | |||||||
INPUT |
VOLTAGE RANGE | Note.4 | 90 ~ 264VAC 127 ~ 370VDC | |||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
EFFICIENCY (Typ.) | 76.5% | 83% | 84% | 84% | 85% | |||
AC CURRENT | 0.5A/230VAC 0.75A/115VAC | |||||||
INRUSH CURRENT(Typ.) | COLD START 45A(twidth=440μs measured at 50% Ipeak) at 230VAC | |||||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 6 units (circuit breaker of type B) / 10 units (circuit breaker of type C) at 230VAC | |||||||
LEAKAGE CURRENT | 0.25mA / 240VAC | |||||||
PROTECTION |
OVERLOAD | 110%~160% rated output power | ||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||
OVERVOLTAGE | 5.75 ~ 6.95V | 13.8 ~ 16.2V | 17.25 ~ 21V | 27 ~ 32.4V | 41.4 ~ 48.6V | |||
Protection type: Shut down o/p voltage, re-power on to recover | ||||||||
ENVIRONMENT |
WORKING TEMP. | -30 ~ 70℃(Refer to “Derating Curve”) | ||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH | |||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, and Z axes | |||||||
SAFETY & EMC |
SAFETY STANDARDS | UL8750 , CSA-C22.2 No. 250.0-13, BIS IS15885, EAC TP TC 004,IP42 , BS EN/EN 62368-1 Approved | ||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC | |||||||
ISOLATION RESISTANCE | I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH | |||||||
EMC EMISSION | Compliance to BS EN/EN55032,BS EN/EN61000-3-2 Class A,BS EN/EN61000-3-3, EAC TP TC 020 | |||||||
EMC IMMUNITY | Compliance to BS EN/EN55035,BS EN/EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), EAC TP TC 020 | |||||||
OTHERS |
MTBF | 5489.6K hrs min. Telcordia SR-332 (Bellcore); 600.8K hrs min. | MIL-HDBK-217F (25℃) | |||||
DIMENSION | 84*57*29.5mm (L*W*H) | |||||||
PACKING | 0.18Kg; 72pcs / 14Kg/ 0.92CUFT | |||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify the EMC Directive on the complete installation. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 6. Length of set up time is measured at the first cold start. Turning ON/OFF the power supply may lead to an increase in the set-up time. 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitudes higher than 2000m(6500ft). 8. Products sourced from the Americas regions may not have the ENEC/BIS/CCC logo. Please contact your MEAN WELL sales for more information. 9. For any application note and IP waterproof function installation caution, please refer to our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf 10. This product is not intended for LED lighting luminaire applications in the EU. (In the EU the LPF/NPF/XLG series are recommended.) ※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx. |
Mechanical Specification
Case No.PCD16A Unit: mm
Block Diagram
fosc: 60KHz
Derating Curve
Static Characteristics
Documents / Resources
![]() |
MEAN WELL APV-35 Series 35W Single Output Switching Power Supply [pdf] Owner's Manual APV-35 Series, APV-35 Series 35W Single Output Switching Power Supply, 35W Single Output Switching Power Supply, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply |
![]() |
MEAN WELL APV-35 Series 35W Single Output Switching Power Supply [pdf] Owner's Manual APV-35-5, APV-35-12, APV-35-15, APV-35-24, APV-35-36, APV-35 Series 35W Single Output Switching Power Supply, APV-35 Series, 35W Single Output Switching Power Supply, Single Output Switching Power Supply, Switching Power Supply, Power Supply, Supply |