MEAN WELL AD-155A 155W Single Output with Battery Charging UPS Function
Features
- Universal AC input/ Full range
- Protections: Short circuit I Overload; Over voltage
- Battery low and battery polarity protection
- Cooling by free air convection
- 100% full load burn-in test
- Fixed switching frequency at PFC 67KHz. PWM 134KHz
- Optional DIN Rail Attachment
SPECIFICATION
MODEL | AD155-A | AD155-B | AD1 55-C | |||||
OUTPUT | OUTPUTNUMBER | CH1 | CH2 | CH1 | CH2 | CH1 | CH2 | |
DC VOLTAGE | 13.8V | 13.3V | 27.6V | 27.1V | 54V | 53.5V | ||
RATED CURRENT | 10.5A | 0.5A | 5A | 0.5A
0-0.5A | 2.7A 0- 2.7A | 0.2A 0 – 0.5A | ||
CURRENTRANGE | 0 – 11.5A | 0 – 0.5A | 0-55A | |||||
RATED POWER | 151.55W | 151.55W | 156.55W | |||||
RIPPLE& NOISE(max.) Note., | 15-0tm/p-p | — | 150mVp-p | —- | 240mVp-p | — | ||
VOLTAGEADJ. RANGE | CH1: 12- 14.5V | CH1 : 24 -29V | CH1 : 48-58V | |||||
VOLTAGETOLERANCE Note.3LINEREGULATION | ±2.0% ±0.5% | — — — — | ±1.0% ±0.5% | – — —— | ±1.0% ±0-.5% | — —- | ||
LOAD REGULATION | ±o.5% | – – | ±0.5% | — — | ±o.5% | — | ||
SETU,PRISE TIME | 1OOOms, 90ms/230VAC 2000ms, 90ms/115VACat full load | |||||||
HOLD UP TIME (Typ,) | 24ms/230VAC 2oms115VACat ru11 l o ad | |||||||
INPUT | VOLTAGE RANGE FREQUENCYRANGE | 88 – 264VAC 124- 370VDC 47 – 63Hz | ||||||
POWER FACTOR ( Typ.) | PF>0.92at lull load | |||||||
EFFICIENCY(Typ) | 80% | 84% | ||||||
ACCURRENT(Typ.) | 2.5A/115VAC 1.5A/230VAC | |||||||
INRUSH CURRENT(Typ.) LEAKAGE CURRENT | COLD START 23A1115VAC 45A/’230VAC <1mA/24 0VAC | |||||||
PROTFCTION | OVERLODA | CH1:105- 135% CH2:0.51 -0.9Arated output power | ||||||
Protection Type : AC Charging Mode : Constant current limiting, recover automatically after fault condition is removed UPS Mode : Protected by Internal fuse | ||||||||
OVERVOLTAGE BATTERYLOW | CH1:1 .87- 18.G3V | CH1:31.74- 37.26V | CH1G: 2.1- 72.9Y | |||||
Protection Type : Shut down O/P voltage, e re-power on to recover 10VJ:0.8 V f1 9.5V(+1.5V-1,V) 39V±2V | ||||||||
ENVIRONMENT | WORKINGTEMP. | -10 – +60ºC (Refer lo “Derating Curve”) | ||||||
WORKING HUMIDITY | 20 – 90% RH non-condensing | |||||||
STORAGE TEM.P, HUMIDITY | -20- +85-ºC, 10 – 95%RH | |||||||
TEMP. COEFFICIETN | ±o 03%FC (0 – 50ºC) | |||||||
VIBRATION | 10- 500Hz. 2G10mni .11cycle,60min.each along X. Y. Z axes | |||||||
SAFETY & EMC (Note4) | SAFETY STANDARDS | UL62368-1, TW esENIEN62368-1A, SINZS 62368.1, EAC TPTC 004 approved | ||||||
WITHSTANDVOLTAGE | IIP-OIP:3KVAC 1/P-F G:1.SKYAC 0/P-FG:O.SKYAC | |||||||
ISOLATION RESISTANCE | IIP-0/ P, I/P-FG, 0/P-FG:1OOM Ohms/ 500VDCI 25″C/ 70%RH | |||||||
EMCEMISSION EMCIMMUNITY | Compliance to BSEN/EN5S032 (CISPR32)Class B,BSEN/EN61000-3-2,-3,EAC TP TC 020 | |||||||
Compliance to BS EN/EN6100-4-2.3.4.5.6.8.11. esENIENS5024. light industry level. criteria A EAC TP TC020 | ||||||||
OTHERS | MTBF | 183.3Khr min. MIL-HDBK-217F /25’CI | ||||||
DIM ENSION | 199•110•50,nm (L-w-H) | |||||||
PACKING | 0,88Kg; 11pi CS/15Kg/0.9oCUFI | |||||||
NOTE |
|
Mechanical Specification
Terminal Pin No. Assignment
Pi n No . 1 | Assignment AC/L | Pin No . 5 | Assignment BAT+ |
2 | AGIN | 6 | BAT. -/COM |
3 | FG | 7 | DC OUTPUTCOM |
4 | NC | 8 | DCOUTPUT+V |
CN1 Pin No. Assignment :JST B2B-XH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
1 | RESET SW | JST XHP or equivalent | JST SXH-001T-P0.6 or equivalent |
2 |
Block Diagram
Derating Curve
Output Derating VS Input Voltage (A)
OPTIONAL DIN RAIL MOUNTING KIT
SIMPLY ADD THE SUFFIX “/DRL” TO THE END OF THE MODEL NUMBER. I.E. “AD155-A/DRL”
Documents / Resources
![]() | MEAN WELL AD-155A 155W Single Output with Battery Charging UPS Function [pdf] Owner's Manual AD-155A 155W Single Output with Battery Charging UPS Function, AD-155A, 155W Single Output with Battery Charging UPS Function, Output with Battery Charging UPS Function, Battery Charging UPS Function, Charging UPS Function, UPS Function, Function |