MAGIC FX PART02302 Spark Effect Machine
Specifications
- Product Name: SMOKE FX
- Model Number: PART02302
- Revision: REV 01-01
FAQ
Q: Can I use any type of fluid with the SMOKE FX?
A: No, only use FX fluids recommended by MAGIC FX for optimal performance and safety.
Q: How do I know if the machine is ready to blast smoke?
A: The display panel will indicate when the machine is heated up and ready for operation.
Q: Can I control multiple SMOKE FX machines with one DMX controller?
A: Yes, you can daisy-chain multiple machines using DMX control for synchronized effects. Ensure proper DMX addressing.
DISCLAIMER
WARNING
Read this manual carefully before installing and/or using this product. Failure to read the manual and to follow the printed instructions may lead to personal injury and/or damage to the product.
© 2024 MAGICFX® All rights reserved.
Nothing from this publication may be copied, reproduced and/or published by means of printing, photocopying or by any other means, without the prior written approval of MAGIC FX.
MAGIC FX reserves the right to modify specifications stated in this manual.
TRADEMARKS
Any brand names mentioned in this manual are registered trademarks of their respective owners.
LIABILITY
MAGIC FX accepts no liability for claims from third parties arising from unauthorised use, use other than that stated in this manual, and use other than in accordance with the General Conditions registered at the Chamber of Commerce. We further refer to the General Conditions. These are available on request, free of charge.
Although considerable care has been taken to ensure a correct and comprehensive description of all relevant components, the manual may nonetheless contain errors and inaccuracies.
Should you detect any errors or inaccuracies in the manual, we would be grateful if you would inform us. This helps us to further improve our documentation.
INTRODUCTION
Congratulations! You have bought a great new product from MAGIC FX.
This manual contains all information required for the intended use of the equipment. Deviation from the described intended use can result in a hazardous situation and/or property damage.
This manual includes notes and warnings on safe operation of the equipment. These notes and warnings are accompanied by the following icons. Read them attentively!
- DANGER
Indicates a hazardous situation that, if not avoided, will result in death or serious injury. This signal word is to be limited to the most extreme situations. - WARNING
Indicates a hazardous situation that, if not avoided, could result in death or serious injury. - CAUTION
Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury. - NOTICE
Indicates information considered important, but not hazard-related (e.g. messages relating to property damage).
LANGUAGE
This document contains the original instructions in English. In case you require other languages please contact MAGIC FX.
ABBREVIATIONS
Abbreviation | Description |
SFX | Special effects |
DMX | Digital Multiplex |
RDM | Remote Device Management |
ECO2JET® | MAGICFX® ECO2JET® |
ECO2JET® Bracket | MAGICFX® ECO2JET® Bracket |
Attachable Fluid Can | MAGICFX® ECO2JET® 2L Attachable Fluid Can |
Omega Brackets | MAGICFX® Omega Bracket (C-T-C 140 mm) – Set of 2 |
OUTDOOR FLUID | MAGICFX® ECO2JET® Outdoor Fluid 5L |
INDOOR FLUID | MAGICFX® ECO2JET® Indoor Fluid 5L |
Abbreviations |
REVISION TABLE
Doc nr | Revision | Date | Description | Author | Approved |
PART02302 | 01-00 | 28-03-2024 | Initial release | MBO | RD |
PART02302 | 01-01 | 02-05-2024 | Updated voltage | MBO | TH |
DESCRIPTION
- The ECO2JET® is a special effects device designed to produce white plumes of smoke resembling a CO2 effect, but without the need for CO2. This innovative machine offers improved safety, durability, and ease of use compared to traditional CO2 effects machines.
- Comprised of three primary components – a pump, heater, and fan – the ECO2JET® operates using a specially formulated fluid, stored in an external fluid can. This fluid can can be rapidly connected to the machine via a convenient quick connector. With the ability to extend the hose horizontally and vertically up to 2 meters, users can store the liquid safely and accessibly.
- The pump draws the fluid into the machine’s heater, where it undergoes vaporization. The resulting vapor is then forcefully propelled into the air by a high-speed fan, creating the desired visual effect. The effect can be propelled up to 12 meters.
- Equipped for compatibility with DMX and RDM systems, the ECO2JET® can be seamlessly integrated into complex setups and used in tandem with multiple machines. Additionally, the ECO2JET® offers two distinct heat-up power modes, allowing users to adapt the machine’s operation to the available power source.
- With its innovative design and versatile functionality, the ECO2JET® represents a safer, more efficient alternative to traditional CO2 effects machines, making it ideal for a wide range of applications in the entertainment industry.
MAIN PARTS
TECHNICAL DATA
Product | Product Name | ECO2JET® | |
Product Code | MFX1801 | ||
Product Type | SMOKE FX | ||
Main Dimensions | Length | 407 mm | 16 in |
Width | 291 mm | 11.5 in | |
Height | 468 mm | 18.4 in | |
Weight | Empty Weight | 30.5 kg | 67.2 lbs |
Packaged Weight | 31.7 kg | 69.9 lbs | |
Environment | Minimum Temperature | – 10 °C | 23 °F |
Maximum Temperature | 50 °C | 122 °F | |
Humidity (Relative) | 20 to 90 % (non-condensing) | ||
Electrical | Voltage Input | 210 – 240 VAC | |
Voltage Frequency | 50 – 60 Hz | ||
Heat-up Power | 1.5 kW (ECO)
3.5 kW (FULL) |
||
Idle Power * | 140 W | ||
Power Connector | Neutrik® powerCON TRUE1 (in&out) | ||
Controlling | Control Options | DMX
Menu: Test Mode |
|
Control Protocols | DMX512-A (ANSI E1.11) RDM (ANSI E1.20) | ||
Control Connectors | Neutrik® 5-pole male/ female XLR | ||
Configuring | Configure Options | On Device RDM | |
Usage | Consumable(s) | MAGICFX® ECO2JET® Outdoor Fluid 5L MFX3090
MAGICFX® ECO2JET® Indoor Fluid 5L MFX3091 |
|
Consumable Consumption | 0.38 L/min | 2.6 min/L | |
Technical data |
* These values are a computed average measured over a longer period of time after the device has finished its initial heating.
PRODUCT IDENTIFICATION
FX FLUIDS
The ECO2JET® uses dedicated fluids from MAGIC FX to create plumes of white smoke. The fluids are available in 5L fluid cans. The fluid can is placed outside the ECO2JET® and connected with the ECO2JET® Fluid Can Lid Assembly (ASS90100) or through a MAGICFX® ECO2JET® Fluid Extension Hose (MFX1805 or MFX1806). Alternatively, the fluid can be poured into an Attachable Fluid Can (MFX1803), which can be mounted with an M6 nut on the ECO2JET®.
WARNING
Do not use other fluids than those that are approved and supplied by MAGIC FX, see the following table. Always follow the instructions as noted on the fluid can. The warranty is void if other fluids are used.
Code | Type of fluid | Volume |
MFX3090 | MAGICFX® ECO2JET® Outdoor Fluid | 5 L |
MFX3091 | MAGICFX® ECO2JET® Indoor Fluid | 5 L |
FX fluids |
ACCESSORIES
Code | Product | Included |
MFX1802 | MAGICFX® ECO2JET® Bracket | |
MFX1803 | MAGICFX® ECO2JET® 2L Attachable Fluid Can | |
MFX1804 | MAGICFX® Omega Bracket (C-T-C 140 mm) – Set of 2 | |
MFX1805 | MAGICFX® ECO2JET® Fluid Extension Hose 1 m | |
MFX1806 | MAGICFX® ECO2JET® Fluid Extension Hose 2 m | |
MFX1807 | MAGICFX® ECO2JET® Flightcase (for 2 pcs) | |
MFX0313 | Schuko to Neutrik® powerCON TRUE1 cable – 1.5 m | |
MFX3104 | Doughty Quick Trigger Clamp (100 kg) M10 | |
MFX3106 | Doughty Half Coupler (100 kg) M10 | |
ASS90100 | Fluid Can Lid Assembly | 1x |
PART02402 | Fluid Mesh Filter G 1/4″ | 1x |
ASS02427 | Air Filter for ECO2JET® (set of 3) | 1x |
MFX3109 | MAGICFX® 5L Fluid Can Bracket | |
Accessories |
Please contact MAGIC FX for additional possibilities.
DMX CONTROL
STANDARD PERSONALITY
When connected to DMX the ECO2JET® is controlled with 1 safety address and 1 operational addresses in the standard personality:
DMX Address | Address range | Control |
Enable address | 1-512 | Device enable / disable |
Start address | 1-512 | Effect trigger |
DMX Addresses |
NOTICE
The enable address cannot be the same as the operational address.
Operating of these addresses results in the following:
DMX Value Enable Ch. | DMX Value Start Ch. | Result | ||
Lower bound | Upper bound | Lower bound | Upper bound | |
0 | 24 | |||
25 | 64 | Hold ≥ 3s:
Reset locking errors |
||
65 | 99 | Device pre-enabled System pressurised | ||
100 | 154 | 0 | 199 | Device enabled
System pressurised, fan spin-up |
200 | 255 | Output effect | ||
155 | 199 | |||
200 | 255 | 0 | 99 | |
100 | 154 | Prime | ||
155 | 255 |
It is advised to use prime mode in the following situations:
- A new or empty 2m ECO2JET® Fluid Extension Hose (MFX1805) is used in the setup.
- The device is at a +1m height difference with the fluid can.
When you link multiple machines with DMX, we advise you to use the same enable address for all machines.
CAUTION
The system is pressurized when pre-enabled, enabled and during effect output.
CAUTION
Once enabled, the fan inside the ECO2JET® starts spinning.
NOTICE
Smoke will come from the machine during priming.
NOTICE
With both heat-up power modes, the maximum continuous duration of the effect is 8 seconds. After this period, the effect will stop automatically. To start the effect again you must reset the effect trigger.
NOTICE
Keep in consideration that during the effect the heater will cool down and the interval between two equal effect durations not only depends on the effect time used, but also on the set heat-up power mode.
EXTENDED PERSONALITY
When connected to DMX the ECO2JET® is controlled with 1 safety address and 2 operational addresses in the extended personality:
DMX Address | Address range | Control |
Enable address | 1-512 | Device enable / disable |
Start address | 1-511 | Effect trigger |
Start address + 1 | 2-512 | Heater |
NOTICE
The addresses cannot conflict with each other.
Operation of the extended mode is equal to the standard mode with the addition of one heater channel:
DMX Value Heater Ch. Result | ||
Lower bound | Upper bound | |
0 | 99 | |
100 | 154 | Hold ≥ 3s: Heater off |
155 | 199 | |
200 | 255 | Hold ≥ 3s: Heater on |
NOTICE
When the heater is disabled the system cannot be pressurized or fired.
NOTICE
Always plug in a DMX Terminator into the DMX output of the final unit in the control sequence. Using a DMX Terminator improves signal reliability.
DISPLAY PANEL
The display panel is located on the backside of the ECO2JET®. Check the following menu structure for all options in the menu. Use the buttons for navigation and selection. The signal LED blinks red when DMX signal is active. The info LED continuously lights red when an error is present.
Menu function | Explanation |
Lock/Unlock Controller | Holding the Lock button for more than 5 seconds will “lock” the display functions. Meaning buttons will not respond. This to avoid accidental change of parameters via display. To unlock, hold the Unlock button for more than 5 seconds. In case system is armed display is locked. |
Reset Errors | In case there is a locking error present, this button will reset the appliance. If the fault does not persist, the locking error will not reappear. |
DMX Personality (STANDARD/ EXTENDED) | Set the DMX personality to standard (enable & start channel) or extended (enable & start + heater channel) |
DMX Start Address (1-512) | Setting the DMX start address. |
DMX Enable Address (1-512) | Setting the DMX Enable Address. |
DMX Footprint | This parameter indicates the DMX footprint, in other words the amount of sequential channels used by the appliance. This does not include the enable channel. |
RDM (On/Off) | Use this function to turn on/off the RDM functionality. |
Test Mode (ON/ OFF) | Enable the Test Mode. The device will start the effect after 3 seconds. The effect will run 1 – 8 seconds set in the run timer. The device then pauses for 1-60 seconds set in pause timer. |
Run Timer (1-8 s) | Set the duration of the effect in Test Mode. |
Pause Timer (1-60 s) | Set the duration of the pause between effects in in Test Mode. |
Hold to prime | Hold the prime button to manually prime the device. |
Heat-up Power Mode (ECO/FULL) | Use this function to toggle between different heat-up power modes: ECO (1500 W), FULL (3500 W) |
Heater (ON/OFF) | Enables or disables the heater. This setting can also be set using the DMX heater channel when in EXTENDED mode, or by RDM. |
Display Flip | Change the display orientation from normal to upside down. In auto mode the machine automatically adjusts the display orientation to the position. |
Display Dimmer (On/Off) | Turn display dimmer on or off. If turned on, the display is dimmed automatically 30 seconds after the last button push. |
Factory Defaults (Yes/No) | Restores the appliance factory default settings. |
Menu functions |
WARNING
Keep all safety precautions in mind when operating Test Mode.
RDM CAPABILITY
Remote Device Management Protocol (RDM) is an enhancement of the DMX512 communication protocol. RDM can be used for configuration and status monitoring while DMX512 takes care of the default controlling.
For RDM you will need an RDM compatible controller.
The following RDM parameters are supported by the ECO2JET®.
RDM parameters are subject of change due to software updates. Contact MAGIC FX for the latest information and updates.
The following sensors are available through RDM:
Sensor | Description |
Heating percentage | The heater percentage is displayed to indicate the status of the heater. It represents the progress of the heat-up process. Once the device is ready, the percentage reflects the remaining effect time. |
Error code | 0 = no error. All other numbers indicate an error. |
Prime finished | 0 = no
1 = yes |
SAFETY
The ECO2JET® has been designed and constructed in such a manner that it can be used safely. This applies to the use, the circumstances and the regulations as described in this documentation. Reading this documentation and following the instructions are therefore necessary for everyone who is authorised to work with the ECO2JET®.
The ECO2JET® must be used in surroundings that:
- Have a reasonably stable temperature of between -10 and 50 °C.
- Have a relative humidity degree between 20 % and 90 % (non condensing).
- Are free of dust, corrosive gases and high concentrations of organic vapours.
- Are free of chlorine fumes.
- Are not situated in the vicinity of a source of vibration.
NOTICE
Do not place the ECO2JET® on top of subwoofers. This may cause internal damage to the machine.
GENERAL SAFETY RULES
- Only authorised persons may work with the ECO2JET®.
- Do not use the ECO2JET® if there are people or animals in the direct output.
- Make sure that children, unauthorised people and animals do not obtain access to the ECO2JET®.
- Make sure there are no freestanding objects or objects that can be damaged by the ECO2JET® within the output distance.
- Do not connect more units to a single electrical circuit than the installed fuse is able to handle. (Calculate the summed load with the electrical data from Chapter 1).
- Do not remove or bypass any safeguards and safety symbols.
- All required safety devices must be in good condition and function properly.
- Ensure sufficient lighting of the surroundings.
- Keep the workplace clean.
INDOOR & OUTDOOR USE
The ECO2JET® is designed for outdoor use and use in well-ventilated indoor spaces.
DANGER
Do not use the ECO2JET® in poor ventilated confined spaces. Exposure to high levels of vapors or smoke can cause skin irritation and may obscure visibility.
NOTICE
Provide the machine with extra protection in heavy rain.
RIGGING
Please follow the European and national guidelines for safe rigging and trussing.
NOISE LEVELS
The environmental noise level as measured at the ear is 95 dB(A). This level of noise is only reached during the short instances that the output is active. Always wear hearing protection when you are within 5 meters of the machine during operation.
SAFETY SYMBOLS
Symbol | Meaning | Position |
![]() |
Read the manual carefully before use! | On the control panel. |
Safety symbols |
SAFETY WARNINGS
6 WARNING | Using a damaged or an improper installed machine can lead to death, serious injury or property damage. Always inspect the machine thoroughly before operation. |
WARNING | Do not install the machine if you are unsure of the safety of a possible installation. |
WARNING | When a safety wire is required, use a safety wire with an emergency link that is tightened with a wrench.
Handtight is not enough. |
WARNING | Make sure the structure intended to hold the machine is calculated for the weight. The ECO2JET® is a heavy machine. Overhead rigging requires extensive experience in calculating load limits, installation materials, and performing periodic safety inspection. Only qualified personnel is allowed to perform this. |
WARNING | Only hoist the machine using the safety steel backdish. Do not hoist using the handles or tension straps. |
WARNING | The safety steel and the emergency link need to have a minimal workload of 40 kg. |
WARNING | Missing or obscured safety symbols on the machine can lead to death or serious injury. Make sure all safety symbols are correctly in place, see section 2.5. |
WARNING
Always create a safety zone around the machine with a radius of 0.3 meter. Make sure that the area is clear of unauthorized persons, animals and objects. Not doing so can result in death or serious injury.
Note that overlap of safety zones in a setup with multiple machines is allowed, as long the air grilles are not obstructed.
WARNING
Always keep the output zone as shown in the image below clear of all people, animals and objects. Not doing so may result in death or serious injury. Note that the zone shifts accordingly when the machine is installed in a tilted position on the stage.
WARNING
A poorly mounted machine will come loose when the machine is operated. This can lead to death, serious injury and/or property damage. Always inspect if the machine is mounted firmly and correctly as according to the instructions in this manual.
DANGER
Do not mount the ECO2JET® to the truss sideways. Only suspend the ECO2JET® from the truss.
WARNING
Make sure there are no objects near the output that can be damaged or overthrown by the ECO2JET®.
WARNING
If non regular sounds come out of the nozzle when the unit is enabled, stop operation immediately and disconnect power. Please contact the service department of MAGIC FX.
CAUTION
Make sure that the Fluid Mesh Filter G 1/4″ is installed.
CAUTION
For your safety, when operating in Test Mode, all authorized personnel are required to wear appropriate safety gear, including protective eyewear and hearing protection.
CAUTION
Make sure that the air grilles of the ECO2JET® are not blocked.
CAUTION
If anything falls into the output opening, immediately cease operation. Contact MAGIC FX.
INSTALLATION AND USE
The ECO2JET® can be positioned on a stage or floor or can be mounted on a truss.
MOUNT ON A STAGE
The ECO2JET® can be placed directly on a stage or floor on its rubber feet or tilted using the ECO2JET® Bracket.
WARNING
The machine may not be placed on its side.
CAUTION
Keep a minimum distance of 30 cm between the machines.
WITHOUT A BRACKET
When placing multiple machines together on stage or floor, make sure the air grilles are not blocked.
WITH AN ECO2JET® BRACKET
The ECO2JET® can also be used on stage with an ECO2JET® Bracket.
More information on using the ECO2JET® Bracket can be found in the ECO2JET® Bracket accessory manual.
MOUNT ON A TRUSS
The following options are available for truss mounting:
- ECO2JET® Bracket (MFX1802)
- Omega Brackets (MFX1804)
- Doughty Quick Trigger Clamp (100 kg) M10 (MFX3104)
- Doughty Half Coupler (100 kg) M10 (MFX3106)
Use the Omega Brackets or the ECO2JET® Bracket to hang the ECO2JET® upside down.
The ECO2JET® is a heavy machine. In static situations, using only one clamp is possible. It is however recommended to use two clamps.
CAUTION
Installing the ECO2JET® in a motion truss is not recommended.
CAUTION
Keep a minimum distance of 30 cm between the machines.
MOUNT WITH OMEGA BRACKETS
The ECO2JET® can be suspended from a truss by attaching Omega Brackets with clamps to the bottom of the machine.
- Flip the ECO2JET® upside down. Be careful with the nozzle.
- Mount clamps (MFX3104 or MFX3106) to the Omega Brackets (MFX1804) using the provided bolts and nuts.
- Attach the Omega Brackets to the quarter turn receptacles in the ECO2JET®.
- Mount the ECO2JET® in a horizontal position only onto a horizontal truss.
CAUTION
Take the recoil of the ECO2JET® into account. Make sure the construction is prepared for the counter force of firing the effect. - Secure the ECO2JET® onto the truss with use of a safety wire on the bottom of the ECO2JET®. Make sure the safety wire is as short as possible. If needed, wind the cable around the truss to pull it tight.
CAUTION
The safety steel and the emergency link need to have a minimal workload of 40 kg.
- By default, the machine is programmed to autoflip the display. However, to preserve a particular configuration use “flip mode” in the menu. This will allow to preserve a desired setting without any automatic adjustments.
- Make sure that the installation complies with all relevant safety requirements, such as creating a safety zone and a free output zone, see Section 2.6.
MOUNT WITH CLAMPS ONLY
This chapter describes the 100 kg Doughty Quick Trigger Clamps (MFX3104) as an example. The 100 kg Doughty Half Couplers (MFX3106) follow a similar process.
- Attach the clamps (MFX3104 or MFX3106) to the M10 mounting holes on the bottom side of the ECO2JET® with the provided bolts.
- Mount the ECO2JET® in a horizontal position onto a horizontal truss. Vertical truss mounting is not permitted.
CAUTION
Take the recoil of the ECO2JET® into account. Make sure the construction is prepared for the counter force of firing the effect. - Secure the ECO2JET® onto the truss with use of a safety wire on the bottom of the ECO2JET®. Make sure the safety wire is as short as possible. If needed, wind the cable around the truss to pull it tight.
CAUTION
The safety steel and the emergency link need to have a minimal workload of 40 kg.
- By default, the machine is programmed to autoflip the display. However, to preserve a particular configuration use “flip mode” in the menu. This will allow to preserve a desired setting without any automatic adjustments.
- Make sure that the installation complies with all relevant safety requirements, such as creating a safety zone and a free output zone, see Section 2.6.
MOUNT WITH AN ECO2JET® BRACKET
The ECO2JET® can also be installed on a truss using an ECO2JET® Bracket.
NOTICE
The ECO2JET® Bracket is an optional accessory and is not included.
More information on using the ECO2JET® Bracket can be found in the ECO2JET® Bracket accessory manual.
CAUTION
The safety steel and the emergency link need to have a minimal workload of 40 kg.
(RE)PLACE THE FLUID CAN
WARNING
Do not use other fluids than those that are approved and supplied by MAGIC FX, see section 1.4. Always follow the instructions as noted on the fluid can. The warranty is void if other fluids are used.
- Make sure that the machine is not in operation. The FX LED indicator is off.
- Place the fluid can including its ECO2JET® Fluid Can Lid Assembly (ASS90100) in the vicinity of the machine, for example in the MAGICFX® 5L Fluid Can Bracket (MFX3109).
- Connect the Fluid can including its ECO2JET Fluid Can Lid Assembly (ASS90100) by using the quick connector.
NOTICE
With a MAGICFX® ECO2JET® Extension Hose (MFX1805 or MFX1806), the hose can be extended. The maximum (height) distance between the fluid can and the ECO2JET® is 2 meters.
WARNING
Only disconnect the fluid can when the device is not enabled or the power is disconnected. This is necessary for the system’s pressure being able to release.
NOTICE
Make sure the hose is not pinched.
MOUNT THE ATTACHABLE FLUID CAN
Instead of connecting a fluid can, an Attachable Fluid Can (MFX1803) can be mounted to the back side of the ECO2JET®.
More information on using the 2L Attachable Fluid Can can be found in the 2L Attachable Fluid Can accessory manual.
CONNECT DMX AND POWER
- Connect a power cable with a Powercon TRUE1 Female connector to the power input. Connect the other end of the power cable to a 210–240 Vac (50 – 60 Hz) power source.
- Connect the female connector of a 5-pole DMX cable in the DMX input. Connect the other end of the DMX cable to your DMX controller.
- Optionally link the power output and the DMX output through to another machine.
- Optionally set the heat-up power mode.
NOTICE
Always plug in a DMX Terminator into the DMX output of the final unit in the control sequence. Using a DMX Terminator improves signal reliability.
SETTING THE HEAT-UP POWER MODE
The heat-up power mode can be changed to heat up faster using the FULL heat-up power mode. This mode allows less machines on a single power group. The heat-up time is longer in the ECO power mode, both in advance and inbetween firing effects. The effect itself remains the same. There are two heat-up power modes:
Mode | Power | Heat-up time |
ECO | 1.5 kW | 18 min |
FULL | 3.5 kW | 9 min |
Heat-up power modes |
Regardless of the power mode selected, the maximum duration of the effect is 8 seconds. Once this time elapses, the effect will automatically cease. To initiate the effect again, you will need to deactivate and then reactivate the Effect trigger. This will enable you to restart the effect and experience it once more.
NOTICE
The effect is the same in each heat-up power mode.
NOTICE
Keep in consideration that during the effect the heater will cool down and the interval between two equal effect durations not only depends on the effect time used, but also on the set heat-up power mode.
PRIME THE ECO2JET®
The ECO2JET® is equipped with a priming function designed to eliminate any trapped air within the system and connected hoses. It is advisable to prime the ECO2JET® before each event if it is positioned at a height difference of +1m relative to the attached fluid canister, or if a new extension hose is used.
- Make sure the device is heated up and a fluid canister is connected and the heater is not disabled.
- Set the DMX value for the enable channel between 200 and 255 to prime.
- Set the DMX value for the start channel between 100 and 154 to prime.
- The FX LED indicator will start blinking and some smoke will be generated by the device.
- When the FX LED indicator solidly lights up, the priming is done.
- The enable and start channel may now be deactivated or the user may continue with Chapter 3.8.Blast with DMX.
NOTICE
The device can also be operated using the Test Mode menu. Keep safety regulations in mind when operating manually.
BLAST WITH DMX
CAUTION
Make sure that the air grilles of the ECO2JET® are not blocked.
NOTICE
In case the ambient temperature reaches unusually high levels, the fan might engage at a low speed to prevent the machine from overheating.
- Make sure that the direct output is free from persons, animals and objects.
- Set the DMX value for the enable channel between 100 and 154. The system is pressurised, the fan is on, and the FX LED indicator lights up.
a. The device can also be pre-enabled to pressurize the system prior to enabling. To trigger the effect the device first must be fully enabled. Refer to Chapter 1.6.DMX control for the exact DMX values. - Set the DMX value for the start channel between 200 and 255 to shoot.
- Enjoy the view! The effect can be activated until the heater temperature is too low, the effect and FX LED indicator then stop. The FX LED indicator lights up again when the temperature is high enough. The effect can then be reactivated.
- When you have finished blowing everyone’s minds, deactivate the start channel.
- Deactivate the enable address.
NOTICE
The device can also be operated using the Test Mode menu. Keep safety regulations in mind when operating manually.
CLEAN UP
CAUTION
The fluid in the machine heats up and is pressurised during operation, and unused hot fluid is returned into the fluid can. Be aware the quick connector can be hot while disconnecting the Fluid Can Lid Assembly of the Attachable Fluid Can.
CAUTION
The heater and nearby surfaces of the machine get hot during operation. Do not touch these parts during or directly after operation. Wait until the machine has cooled down.
- Make sure that the ECO2JET® is not in operation (FX LED indicator is off) and is cooled down.
- Disconnect the cables.
- Disconnect the fluid hose using the quick connector and remove the fluid can.
- Dismount the machine.
TROUBLESHOOTING
In case the display shows one of the following error/alarm or warning codes, act accordingly:
Code | Meaning | Solution |
010 | Heat-up error | • Contact MAGIC FX. |
011 | Fan controller error | • Power cycle the device. If it happens again, contact MAGIC FX. |
015 | Fan RPM error | Fan not running at the desired speed.
• Power cycle the device. • Check if the fan is clear of any objects. • If it happens again, contact MAGIC FX. |
018 | Pressure problem | • Make sure that the fluid can is not empty.
• Make sure that all hoses are connected properly and are not pinched. • Make sure all fittings are leakproof. • Make sure that the Fluid Mesh filter G 1/4″ is not clogged. |
020 | Pressure sensor failure | • Contact MAGIC FX. |
100 | DMX address conflict | • Change either the DMX safety or the DMX start address |
104 – 107 | Thermocouple error | • The thermocouple is not attached correctly. Contact MAGIC FX. |
120 | Heater overheat error | • Contact MAGIC FX. |
128 | Fan communication error | • Power cycle the device. If it happens again, contact MAGIC FX. |
Troubleshooting |
Code | Meaning | Solution |
129 | Hardware overheat error | Internal device hardware is overheated.
• Make sure the device is used within its operating temperature. |
130 | Temperature sensor fault | Hardware temperature sensor fault.
• Power cycle the device. If it happens again, contact MAGIC FX. |
208 | Temperature overheat warning | • Make sure the device is used within its operating temperature. |
211 | Heat-up warning on | • If it happens often, contact MAGIC FX. |
212 | Hardware overheat warning | • Make sure the device is used within its operating temperature. |
213 | Heater off warning | • This warning is displayed when the user disabled the heater. |
Troubleshooting |
Always contact MAGIC FX if any malfunctions or (unlisted) errors occur that cannot be solved with the instructions as described in this manual.
In this stage, MAGIC FX appreciates it if the occurrence of errors/warnings will be reported as detailed as possible.
MAINTENANCE
To achieve the maximum service life of the ECO2JET® you must regularly clean the ECO2JET® and test if it is functioning correctly.
Contact MAGIC FX if the ECO2JET® is not functioning correctly.
DANGER
Do not replace parts yourself other than specified in this chapter; always consult MAGIC FX.
DANGER
Always cut off the power before performing maintenance.
REPLACE THE AIR FILTER
- Remove the air grille using a T10 Torx screwdriver.
- Remove the old air filter from the air grille.
- Place the replacement air filter (ASS02427) in the air grille.
- Re-attach the air grille using a T10 Torx screwdriver.
REPLACE THE FLUID MESH FILTER
NOTICE
Replace the Fluid Mesh Filter at least once a year.
- Place the ECO2JET® on a table with the service lid pointed towards the floor.
Make sure the service lid protrudes over the edge of the table so you can access it.
- Remove the service lid using a T10 Torx screwdriver.
- Remove the large plug using a size 8 hex key.
- Remove the Fluid Mesh Filter G 1/4″ using a large flat screwdriver.
- Attach the replacement Fluid Mesh Filter G 1/4″ (PART02402) using a large flat screwdriver.
- Re-attach the large plug using a size 8 hex key. Use a torque wrench set to 16 Nm if available.
- Re-attach the service lid using a T10 Torx screwdriver.
CORRECT DISPOSAL
This symbol on the product and / or accompanying documents means that used electrical and electronic products should not be mixed with general household waste. For proper treatment, recovery and recycling, please take this product to designated collection points where it will be accepted free of charge. Alternatively, in some countries you may be able to return your products to your local retailer upon purchase of an equivalent new product. Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please contact your local authority for further details of your nearest designated collection point. Penalties may be applicable for incorrect disposal of this waste, in accordance with your national legislation.
EC DECLARATION OF CONFORMITY
Documents / Resources
![]() |