Lumiax-logo

Lumiax MPPT-DC Series MPPT Solar Charge Controller

Lumiax-MPPT-DC-Series-MPPT-Solar-Charge-Controller-product

Specifications

Item MPPT0850-DCLi/G

(select/R/V)

MPPT0875-DCLi/G

(select/R/V)

MPPT1050-DCLi/G

(select/R/V)

MPPT1550-DCLi/G

(select/R/V)

 

 

 

 

 

Battery Parameters

System Voltage 12V
Max Charging Current 8A 10A 15A
Max volt on Bat. Terminal 25V
Battery Type Liquid, Gel, AGM and Lithium(Programmable, default: Lithium)
 

 

Liquid, Gel and AGM

MPPT Charging Voltage <14.5V@25℃
Boost Voltage 14.5V @25℃
Equalization Voltage 14.8V @25℃(Liquid, AGM)
Float Voltage 13.7V @25℃
Low Volt. Disconnect 10.8~11.8V(Programmable)
Reconnect Voltage 11.4~12.8V(Programmable)
Overcharge Protect 15.5V
Temp. Compensation -4.17mV/K per cell (Boost, Equalization), -3.33mV/K per cell (Float)
 

Lithium

Charging Volt. target 10.0~17.0V(Programmable, default: 14.4V)
Charging Volt. recovery 9.2~16.8V(Programmable, default: 14.0V)
Low voltage disconnect 9.0~15.0V(Programmable, default: 10.8V)
Low voltage reconnect 9.6~16.0V (Programmable, default: 11.8V)
0℃ Charging protection Yes, Slow, No(Programmable)
 

Panel Parame- ters

Max volt on PV terminal *1 35V 60V 45V 35V
Max input power 100W~120W 120W~150W 180W~225W
Dusk/Dawn detect volt. 3.0~8.0V (Programmable)
Day/Night delay time 0~30min(Programmable)
MPPT tracking range (Battery Voltage +1.0V)~Voc*0.9 *2
 

 

Load Parame- ters

Output Power 1~50W 1~60W 1~80W
Output Voltage 20 ~ 35V 20 ~ 55V 20~45V 20~35V
Current setting range 0.15~3.0A(Programmable)
Min current 100mA(Dimming)
Current precision ±2%
Dimming 0~100%(Programmable)
Voltage of start dimming 11.8~12.5V(Gel,AGM and Liquid); 10.0~17.0V(Lithium)
Dimming percentage 1~20%(Programmable)
 

 

 

 

System Parameters

Max tracking efficiency >99.9%
Max charge conversion 96.5%
Max LED driver efficiency 96%
communication mode Infrared/2.4G/IOT
Induction mode Infrared Human Sensing/Microwave Sensing
Self consumption 6~25mA
Dimensions 63*85.8*23.1mm 81*85.8*23.1mm
Net weight 230g 260g
Ambient temperature -35~+60℃
Ambient humidity 0~100%RH
Protection degree IP67
Max Altitude 4000m
  1. This value represents the maximum voltage of the solar panel at the minimum operating ambient temperature.
  2. Voc means the open circuit voltage of the solar panel.
  3. Model name +”G”, means 2.4G communication, R series have PIR function, Products with a -V tail have a microwave induction function.
Item MPPT1075-DCLi/G

(select/R/V)

MPPT1575-DCLi/G

(select/R/V)

MPPT2075-DCLi/G

(select/R/V)

 

 

 

 

 

Battery Parameters

System Voltage 12V/24V automatical recognization*3
Max Charging Current 10A 15A 20A
Max volt on Bat. Terminal 35V
Battery Type Liquid, Gel, AGM and Lithium(Programmable, default: Lithium)
 

 

Liquid,

Gel

and AGM

MPPT Charging Voltage <14.5/29.0V@25℃
Boost Voltage 14.5/29.0V @25℃
Equalization Voltage 14.8/29.6V @25℃(Liquid, AGM)
Float Voltage 13.7/27.4V @25℃
Low Volt. Disconnect 10.8~11.8V/21.6~23.6V(Programmable)
Reconnect Voltage 11.4~12.8V/22.8~25.6V(Programmable)
Overcharge Protect 15.5/31.0V
Temp. Compensation -4.17mV/K per cell (Boost, Equalization), -3.33mV/K per cell (Float)
 

Lithium

Charging voltage target 10.0~32.0V(Programmable, default: 14.4V)
Charging voltage recovery 9.2~31.8V(Programmable, default: 14.0V)
Low voltage disconnect 9.0~30.0V(Programmable, default: 10.8V)
Low voltage reconnect 9.6~31.0V (Programmable, default: 11.8V)
0℃ Charging protection Yes, Slow, No(Programmable)
 

Panel Parame- ters

Max volt on PV terminal 60V*1 55V *1
Max input power 130W/260W 200W/400W 260W/520W
Dusk/Dawn detect volt. 3.0~20.0V (Programmable)
Day/Night delay time 0~30min(Programmable)
MPPT tracking range (Battery Voltage +1.0V)~Voc*0.9 *2
 

 

Load Parame- ters

Output Power 10~60W/20~120W 10~90W/20~180W
Output Voltage 15~60V/35~60V 20~55V/30~55V
Current setting range(Programmable) 0.15~4.0A 0.15~6.0A
Min current 100mA(Dimming)
Current precision ±2%
Dimming 0~100%(Programmable)
Voltage of start dimming 11.8~12.5V/23.6~25.0V(Gel,AGM and Liquid); 10.0~32.0V(Lithium)
Dimming percentage 1~20%(Programmable)
 

 

 

 

System Parameters

Max tracking efficiency >99.9%
Max charge conversion 97.5%
Max LED driver efficiency 96.5%
communication mode Infrared/2.4G/IOT
Induction mode Infrared Human Sensing/Microwave Sensing
Self consumption 6~25mA
Dimensions 113*88.5*24.3mm 145*85.8*30mm 145*95.8*42.5mm
Net weight 370g 550g 700g
Ambient temperature -35~+60℃
Ambient humidity 0~100%RH
Protection degree IP67
Max Altitude 4000m
  1. This value represents the maximum voltage of the solar panel at the minimum operating ambient temperature.
  2. Voc means the open circuit voltage of the solar panel.
  3. Around oblique line value separately on behalf of 12V and 24V system’s value.
  4. Model name +”G”, means 2.4G communication, R series have PIR function, Products with a -V tail have a microwave induction function.

Product Usage Instructions

Description of Function:
The MPPT-DC series intelligent MPPT solar controller is programmable and designed for boost mode LED solar street light systems. It includes a constant current driver function, with a charging efficiency approximately 20% higher than traditional PWM controllers, reducing system costs.

 Safety Instructions:

  • Use the solar charge controller only in PV systems following the user manual and module manufacturers’ specifications.
  • Avoid short-circuiting batteries and always connect a fuse directly to the battery to prevent short circuits.
  • Avoid sparks, fire, or flames near batteries as they can produce flammable gases.
  • Avoid touching or short-circuiting wires or terminals; use isolated tools, stand on dry ground, and keep hands dry.
  • Keep children away from batteries and the charge controller.

Dimensions:

Controller Dimension: 23.1mm x 42.2mm x 60.2mm

Features:

  • Max Power Point Tracking(MPPT) technology with tracking efficiency over 99.9%.
  • Full digital technology for high charge conversion efficiency.
  • Output constant current with adjustable settings.
  • 5 stages time and dimming adjustment.
  • Battery type selection: AGM, Liquid, GEL, and Lithium.

MPPT-DC series

MPPT Solar charge controller with LED driver built-in (Constant Current, Boost) 12/24V, 8/10/15/20A

Solar charge controller MPPT-DC series User Manual

Dear Clients,
Thanks for selecting the MPPT-DC series solar controller. Please take the time to read this user manual, this will help you to take advantage of controller’s new features. This manual gives important recommendations for installing, programming, using and so on. Read it carefully in your own interest please.

Description of Function 
MPPT-DC series intelligent MPPT solar controller is programmable and especially for boost mode LED solar street light system. It includes constant current driver function. The charging efficiency is about 20% higher than the traditional PWM controller, which can drop the cost of the whole system.

  • Innovative Max Power Point Tracking(MPPT) technology, tracking efficiency >99.9%
  • Full digital technology, high charge conversion efficiency up to 97.5%, discharge conversion efficiency up to 96.5%. Can output constant current (output current can be set) 5 stages time and dimming can be adjusted
  • Can read parameters and running status
  • If battery voltage is low, it can be set to dimming Dimming start voltage and percentage can be set
  • Day/Night threshold can adjust automatically
  • AGM, Liquid, GEL and Lithium battery for selection
  • 0℃ Charging Protection(Lithium)
  • When BMS power off because of LVD, it can activate the system automatically
  • External temperature sensor, automatic temperature compensation(AGM, Liquid and GEL)
  • Four stages charge way: MPPT, boost, equalization, float Remote Unit to configure, with LCD display
  • IP67, Strong and durable aluminum caseFull automatic electronic protect function

Safty Instruction and Waiver of Liability

Safety

  1. The solar charge controller may only be used in PV systems in accordance with this user manual and the specs of other module manufacturers. No energy source other than solar gen. may be connected to the solar charge controller.
  2. Batteries store a large amount of energy, never short circuit a bat. under all circumstances. We strongly recommend connecting a fuse directly to the battery to protect any short circuit at the bat wiring.
  3. Batteries can produce flammable gases. Avoid making sparks, fire or any naked flame. Make sure that the bat. room is ventilated.
  4. Avoid touching or short circuiting wires or terminals. Be aware that the voltages on special terminals or wires can be as much as twice the battery voltage. Use isolated tools, stand on dry ground, and keep your hands dry.
  5. Keep children away from batteries and the charge controller.

Liability Exclusion
The manufacturer shall not be liable for damages, especially on the battery, caused by use other than as intended or as mentioned in this manual or if the recommendations of the battery manufacturer are neglected. The manufacturer shall not be liable if there has been service or repair carried out by any unauthorized person, unusual use, wrong installation, or bad system design.

Dimensions(Unit:mm)

Controller dimension

Lumiax-MPPT-DC-Series-MPPT-Solar-Charge-Controller-fig- (1) Lumiax-MPPT-DC-Series-MPPT-Solar-Charge-Controller-fig- (2)Lumiax-MPPT-DC-Series-MPPT-Solar-Charge-Controller-fig- (3)

Sensor dimension(Unit:mm)Sensor lines length:400mm Infrared sensor head

v Lumiax-MPPT-DC-Series-MPPT-Solar-Charge-Controller-fig- (5)

MRS05 is currently only compatible with MPPT-DCLiGV series products.

Installation

The following diagrams provide an overview of the connections and the proper order

Lumiax-MPPT-DC-Series-MPPT-Solar-Charge-Controller-fig- (6)

Lumiax-MPPT-DC-Series-MPPT-Solar-Charge-Controller-fig- (8)Hot plugging is prohibited! Please connect the inductive sensor to R/V series controller first!

  1. Firstly, connect the sensing probe with the corresponding interface on the controller.
  2. As the chart, connect the load with the corresponding brown(positive) and blue(negative) cables firstly, then seal them with tape.
  3. Connect battery with the corresponding red(positive) and black(negative) cables. L oad w ill b e o n after 5s.
  4. Connect panel with the corresponding red(positive) a nd black/green( negative) cables, the load will be off after 5s, and the controller begins charging.
  5. Refer to 9.1 LED indications and Faults & Alarms to confirm the LED display status.
    • Make sure the wire length between battery and controller is as short as possible.
    • Recommended minimum wire size:
      • 8/10A: 2.5 mm²; 15/20A: 4 mm².

Transportation mode(Lithium)
The controller is generally integrated with the lithium battery in the lithium battery pack for transport, if the controller works normal during transport, it will waste of energy and increase the transport risk. If the controller is set to transport mode, the load has no output, then the power consumption is reduced by about 60%, to avoid lithium battery voltage too low.

Open circuit protection
If the controller is only connected with the battery, but not connected with solar and load, the controller will enter transportation mode after 5 minutes.

Press the “Test” key in transport mode

  • Press the “Back” and “Backlight” key at the same time more than 3s, the remote controller will work in transport mode.
  • Press the “Test” key in the transport mode, the remote controller displays “Transport OK” and will beep a long sound, the controller enters into transport mode.

If the controller enters transport mode, the red LED will slow flash(0.2s on/5s off) , the green and yellow led will be off and the remote control displays “Open CP”.

Exit the transportation mode
When the load is properly connected, press the test key or connect the solar more than 1s during daytime, the transport mode will terminate and the controller will work normally.

Remote controller, Default setting 
Setting can be changed using the “S/SG-Unit” infared remote programmer. For detailed instructions and settings, please see the S/SG-Unit programmer remote manual.

Lumiax-MPPT-DC-Series-MPPT-Solar-Charge-Controller-fig- (7)

Remark:

  • S-Unit:
  • Be sure to set only one controller at a time.
  • SG-Unit:
    1. It’s ability to set up multiple controllers at the same time.
    2. The indicators and load will be turned off for 1 second and on for 3 seconds after the controller receives the parameters successfully(according to the actual current), and then return to normal status.

Test function
Press the “Test” key of S/SG-Unit, the controller will turn on load for 10s. During daytime, the testing function can help users to verify correct installation or for system trouble shooting. 10s later the load will automatically turn off.

Read the running status
Press the “Status” key of the S/SG-Unit to read the running status of the controller.

Num Name Name describe Unit
 

1

Status: Batt V Load I Load V PV V

PV I

Energy OD Times FC Times Day1-HV Day1-LV Day2-HV Day2-LV Day3-HV

Day3-LV

Charge

Battery voltage Load current Load voltage PV voltage

PV current

Total generating capacity Over discharge times Fully charge times

A day ago highest voltage A day ago lowest voltage

Two days ago highest voltage Two days ago lowest voltage Three days ago highest voltage

Three days ago lowest voltage

 

V A V V A AH

Times Times V

V V V V

V

2
3
4
5
6
7
8
9
10
11
12
13
14

Read the parameters
Press the “Parameter” key of the S/SG-Unit to read the setting parameters of the controller.

Num Name MPPT-DC
1 Time1 4H
2 Dim1 100%
3 Time2 0H
4 Dim2 100%
5 Time3 0H
6 Dim3 100%
7 Time4 0H
8 Dim4 0%
9 Time5 0H
10 Dim5 100%
11 D/N Thr 5.0V
12 D/N Dly 0min
13 Load I 0.3A
14 Dim Auto Yes
15 Dim V 12.5V
16 Dim % 8%
17 Battery Li
18 CVT 14.4V
19 CVR 14.0V
20 LVD 10.8V
21 LVR 11.8V
22 DelayOff 10s
23 Dim NP 10%
24 Password 0000

Password only applies to SG-Unit.

Starting up the controller

Self Test
As soon as the controller is connected to battery, it starts self test. Then the display changes to normal operation.

Battery Type

  • The controller applies to Lithium, AGM, Liquid and Gel battery, the factory default setting is suitable for Lithium battery.
  • When the controller is set to Lithium battery, the charging target voltage and charging recovery voltage can be set according to customer requirements.
  • The controller adjusts itself automatically to 12V or 24V system voltage when it is set to Gel, Liquid or AGM battery. If the battery voltage on start-up is 0V-15.5V then the controller infers a 12V system.
  • If the battery voltage is 20V-30V the controller infers a 24V system.If the battery voltage is not within the normal operating rang(ca.0 to 15.5V or ca.20 to 30V) at start-up, please refer to 9.2 Faults & Alarms.

0℃ Charging Protection

  • “0℃ Chg” can be set to “Yes”, “Slow” or “No”. When the controller detects that the ambient temperature is higher than 0℃, the charging function is normal. when the ambient temperature is low than 0℃, if the “0℃ Chg” is set to “Yes”, the charging function is normal, else if the “0℃ Chg” is set to “slow”, the max charging current is 20% of the rated current, else if the “0℃ Chg” is set to “No”, the controller does not charge the battery.
  • The user can select the appropriate charging method.

Streetlight Function 
For controllers with infrared sensing function( R series), if work mode is set to “Five-stage Night Mode T0T mode”,

  • “DelayOff “and “Dim NP” work in “Time3″and Time4”.
  • “DelayOff” setting range: 10~150s.
  • “Dim NP” setting range: 0~100%.

Dusk to Dawn (D2D, no induction function)

Lumiax-MPPT-DC-Series-MPPT-Solar-Charge-Controller-fig- (9)If “Time1” is set to “D2D”,the controller works in dusk to dawn mode.

  1. MPPT-DC controller is set to D2D mode, the corresponding dimming setting is still valid.
  2. If “Time1” is set to D2D mode, “Time4” can not be set to T0T mode.

Five-stage Night Mode(Time3、Time4 can induction)

Lumiax-MPPT-DC-Series-MPPT-Solar-Charge-Controller-fig- (10)You can set the Time 1-5 and Dim 1-5 with S/SG-Unit.

T0T mode(Time3、T0T can induction)

Lumiax-MPPT-DC-Series-MPPT-Solar-Charge-Controller-fig- (11)If “Time4” is set to “T0T”, this mode is T0T mode.

  • If “Time4” is set to T0T mode, “Time1” can not set to D2D mode.

Parameter setting example:

  • Time1: 1.0H/100% Time2: 2.0H/80%
  • Time3: 3.0H/60% Time4: T0T/40%
  • Time5: 2.0H/100%
  • DelayOff: 10s Dim NP: 10%

The controller works as follows:
After the arrival of the evening the first time the load is lit for 1 hour (full power 100%), the second time the load is lit for 2 hours (power 80%), the third time load light for. 3 hours (when people is near the lamp then the load is 60% light, when people is away from the lamp the load is 60% * 10% light), and then the controller according to the actual night time automatically calculate the length of the fourth paragraph (when people is near the lamp then the load is 40% light, when people is away from the lamp the load is 40% * 10% light), the fifth time load light 2 hours (full power 100%).

LVD, LVR, Threshold, Dimming

Low Voltage Disconnect (LVD)
When the battery voltage drops below the LVD voltage, the controller will disconnect the load to prevent deep discharge of the battery. If this occurs, the battery should be well charged before resuming use.

Gel, Liquid and AGM Lithium
MPPT0850/0875/

1050/1550-DCLi

10.8~11.8V 9.0V~15.0
MPPT1075/1575

/2075-DCLi

10.8~11.8/21.6~23.6V 9.0V~30.0V

Low Voltage Reconnect (LVR)
If the controller goes into low voltage disconnect, it will restore only when the battery being recharged to the recovery voltage.

Gel, Liquid and AGM Lithium
MPPT0850/0875/

1050/1550-DCLi

11.4~12.8V 9.6V~16.0
MPPT1075/1575

/2075-DCLi

11.4~12.8/22.8~25.6V 9.6V~31.0V

Day/Night Threshold, Day/Night Delay
The controller recognizes day and night based on the solar array open circuit voltage. This day/night threshold can be modified according to local light conditions and the solar array used.

Day/Night threshold setting range:

MPPT0850/0875/1050/1550-DCLi 3.0~8.0V
MPPT1075/1575/2075-DCLi 3.0~20.0V
  • In the evening, when the solar array open circuit voltage reaches the setting day/night threshold, you can adjust the day/night delay time to make the load turn on a little later.
  • Day/Night delay time setting range: 0~30min.

Lumiax-MPPT-DC-Series-MPPT-Solar-Charge-Controller-fig- (12)

  1. Day/Night threshold voltage should be set around 0.22 times of open circuit voltage.
  2. Day/Night threshold voltage of load disconnect is 1V higher than the setting data, means the load will disconnect when the solar voltage at 4.0~9.0/4.0~21.0V.
  3. The controller has an automatic day/night threshold adjustment function. If the lowest voltage of solar array is higher than the setting day/night threshold, the load has no output in first night, 24 hours later the controller can automatically adjust the day/night threshold to meet the requirements of lighting at night.

Auto Dimming

Auto Dimming mode
The “Dim Auto” item of S/SG-Unit is set to “Yes”, set “Dim V” and “Dim %” at the same time, press the “Send” key to set up the controller. when the battery voltage is lower than the voltage of “Dim V” , it starts to dimming automatically. Battery voltage reduces per 0.1/0.2V, load current decreased according to the set of “Dim %”, the minimum output current is 10% of the setting current.

  • If the controller is set to “Dim” or “Auto Dim”, the minimum output current can be as low as 100mA.

365mode(Lithium)
365 mode is based on the battery power (charge power, discharge power) energy control. If the battery charge more during the day, then discharge more at night. The controller can calculate the dimming ratio according to the charging power and the remaining power of battery, so as to avoid the load shutdown due to the low battery voltage.

  • When using the 365 mode, the system should be designed to meet the requirements of three rainy days.

LED indications and Faults & Alarm

Lumiax-MPPT-DC-Series-MPPT-Solar-Charge-Controller-fig- (13)

LED Display Explanation

LED Status Function
 

 

Green LED

On Solar panel is correctly connected,

but not charged

Fast flash(0.1/0.1s) Charging
Flash(0.5s/0.5s) Equal or Boost Charging
Slow flash(0.5/2s) Float Charging、Lithium

constant voltage charge

 

Yellow LED

Off Over voltage protection
On Battery is normal
Slow flash(0.5/2s) Battery voltage is low
Fast flash(0.1/0.1s) Low voltage protection
 

 

Red LED

Off Work normal(Standard

version)

On The output power is 0
Super slow(0.2/5s) Open circuit protection
Flash(0.5s/0.5s) Over temperature
Fast flash(0.1/0.1s) Short circuit or

Over current protection

Red

LED

respo-

nse

Slow flash(2.5s/ 2.5s)*1 Work normal(Induction probe)
  • Detailed fault information can be read by S/SG-Unit remote controller.
  • This data indicates the red indicator status of PIR sensor of infrared induction version.

Faults & Alarms

Fault Status Reason Remedy
 

Loads are not

powered

Low volt.

protection

Battery capacity is low Load will be reconnected when battery is recharged
Overcurrent, short circuit protection Loads are over current or short circuit Switch off all loads, remove short circuit, load will be reconnected

after 1 minute automatically

Over temp. protection Controller temp. is too high Load reconnects after temp. reduces
 

High voltage at battery terminal

 

Over voltage protection

High battery voltage

>15.5V/31.0V

Check if other sources overcharge the battery.

If not,controller is damaged.

Battery wires or battery fuse damaged, battery has high resistance.  

Check battery wires, fuse and battery.

Can’t recognize system voltage  

All LED

fast flashing

Battery voltage is not in right range Charge or discharge, make battery voltage in the right range
Battery is empty after a short time Low

voltage

protection

 

Battery has low capacity

 

Change battery

Battery can’ t be charged Green LED

is on

PV panel fault or reverse connection Check panels and connection wires
  • Lithium: Battery overvoltage >(CVT+0.2V)
  • Gel, Liquid and AGM: Battery overvoltage >15.5/31.0V

Safety Features

Solar terminal Battery terminal Load terminal
Reverse

polarity

Protected *2 Protected Protected
Short circuit Protected*1 Protected *2 Switches off immediately
Over current     Switches off with delay
Reverse

Current

Protected    
Over voltage Max *3 Max*4  
Under voltage     Switches off
Over temp. The controller cuts off the load if the

temperature reaches the set value.

  1. When the PV doesn’t charge, the controller will not be damaged if a short-circuit just happened in the PV array. Warning: It is forbidden to short-circuit the PV array during charging .Otherwise, the controller may be damaged.
  2. Battery must be protected by fuse, otherwise battery will be damaged.
  3. Please refer to “12.Technical Data” to get the max voltage of PV panel.
  4. Please refer to “12.Technical Data” to get the max voltage of battery.

Warning: The combination of different error conditions may cause damage to the controller. Always remove the error before you continue connecting the controller.

Recommended connection of LED lights

Load
Following connect ways is for the LED lights

  • (Vf: 2.9V~3.4V; I: 300mA, Power: 1W )

Lumiax-MPPT-DC-Series-MPPT-Solar-Charge-Controller-fig- (14)

System Voltage Output Voltage Load current LED chips connection
MPPT0850/1550

-DCLi

20~35V  

0.15~3.0A

M=7~10

N=1~10

MPPT1050-DCLi 20~45V M=7~14

N=1~10

MPPT0875-DCLi 20~55V M=7~18

N=1~10

MPPT1075-DCLi 15~60V 0.15~4.0A M=5~18

N=1~20

MPPT1575/2075

-DCLi

20~55V 0.15~6.0A M=7~18

N=1~20

Sensor

Lumiax-MPPT-DC-Series-MPPT-Solar-Charge-Controller-fig- (15)

Type Angle(θ) High(H) Width(D)
Infrared sensor(IR) 120° 6~8m 6~8m
Microwave sensor(WB) 120° 6~8m 7~12m

Induction Introduction :

  • Human body infrared sensing sensor: A human body sensing sensor made using the pyroelectric effect. The infrared sensing range varies with temperature and lighting conditions.

Microwave Radar Sensing Sensor: A moving object detector made using the Doppler effect principle, with high radar sensing sensitivity and is not susceptible to environmental, temperature, dust, and other impacts.

  1. The microwave induction controller can only be equipped with a microwave induction probe and cannot use external sensing probe, otherwise, the infrared sensing probe may be damaged!!!
  2. The sensor which installed in the plastic and glass lampshade will reduce the sensitivity.
  3. Sensor range will change with temperature, light conditions and so on, subject to the actual measurement.
  4. The distance between any inductive sensors should be greater than 3m.
  5. Please ensure that there are no moving signals around the sensor, such as fan, DC motor, sewer pipe, air outlet, etc., the sensor may generate false trigger.

FAQs

Q: Can the MPPT-DC series solar charge controller be used with any type of battery?

A: The controller supports AGM, Liquid, GEL, and Lithium batteries for selection.

Q: What is the warranty coverage for the MPPT-DC series solar charge controller?

A: Please refer to the warranty information provided by the manufacturer for details on warranty coverage.

Documents / Resources

Lumiax MPPT-DC Series MPPT Solar Charge Controller [pdf] User Manual
MPPT-DC Series MPPT Solar Charge Controller, MPPT-DC Series, MPPT Solar Charge Controller, Solar Charge Controller, Charge Controller

References

Leave a comment

Your email address will not be published. Required fields are marked *