LIGHTWARE logo1

LIGHTWARE PRO20-HDMI-R100 AV Over IP Multimedia System

Quick Start Guide

__________________________

LIGHTWARE PRO20- UBEX-PRO20-HDMI-R100 2xMM-2xDUO
LIGHTWARE PRO20- UBEX-PRO20-HDMI-R100 2xMM-QUAD
LIGHTWARE PRO20- UBEX-PRO20-HDMI-R100 2xSM-2xDUO
LIGHTWARE PRO20- UBEX-PRO20-HDMI-R100 2xSM-QUAD
LIGHTWARE PRO20- UBEX-PRO20-HDMI-R100 2xSM-BiDi-DUO

Important Safety Instructions

Please read the supplied safety instruction document before using the product and keep it available for future reference.

LIGHTWARE PRO20- Note The extender is Class 1 laser product.

Introduction

UBEX (Ultra Bandwidth Extender) product family offers a new optical solution allowing 4K@60Hz 4:4:4 uncompressed signal extension with extra low latency for the users. We use packet-based transmission instead of the conventional method.

Box Contents

LIGHTWARE PRO20- Box Contents 1

UBEX R-series endpoint device

LIGHTWARE PRO20- Box Contents 2

Power cable with Neutrik powerCON connector

LIGHTWARE PRO20- Box Contents 3

Safety and warranty info, Quick Start Guide

Front View – All Models

LIGHTWARE PRO20- Front View

Rear View – 2xMM-QUAD / 2xSM-QUAD

LIGHTWARE PRO20- Rear View 1

Rear View – 2xSM-BiDi-DUO

LIGHTWARE PRO20- Rear View 2

Rear View – 2xMM-2xDUO / 2xSM-2xDUO

LIGHTWARE PRO20- Rear View 3

(1) Status LEDs The LEDs give immediate feedback about the recent status of the extender.
(2) LCD screen LCD screen showing the most important settings and parameters in the front panel menu. The available settings and information depends on the current application mode (Extender mode or Matrix mode).
(3) Jog dial control knob Easy setting and menu navigation by the jog dial control. Keep dial and click while getting feedback on the LCD.
(4) Reset button Reboots the device (the same as disconnecting from the power source and reconnecting again).
(5) Neutrik powerCON AC connector Neutrik powerCON TRUE1 NAC3MPX-WOT connector accepting 100-240 V, 50 or 60 Hz.
(6) Neutrik etherCON Ethernet connectors Neutrik etherCON NE8FDV-YK locking RJ45 connectors for 1 Gbps Ethernet connections to control the device, for user Ethernet access, and firmware upgrade purpose.
(7) HDMI input ports HDMI input ports with HDMI 2.0 support for source devices.
(8) HDMI output ports HDMI output ports with HDMI 2.0 support for sink devices.
(9) Neutrik opticalCON QUAD optical connector Neutrik opticalCON QUAD NO4FDW-A singlemode or multimode fiber optical connector. 
  • 2xMM-QUAD: supports multimode cable connection. 
  • 2xSM-QUAD: supports singlemode cable connection.
(10) Neutrik opticalCON DUO BiDi optical connector Neutrik opticalCON DUO NO2-4FDW-A singlemode fiber optical connector with BiDi support.
The connector does not support the Neutrik opticalCON crossed fiber wiring (A-A; B-B) cable. Please use standard (A-B) cable only.
(11) Neutrik opticalCON DUO optical connector 2x Neutrik opticalCON DUO NO2-4FDW-A singlemode or multimode fiber optical connector. 
  • 2xMM-2xDUO: supports multimode cable connection. 
  • 2xSM-2xDUO: supports singlemode cable connection.
Front Panel Operation

Navigation in the LCD Menu

The front panel has a color LCD showing the most important settings and parameters. The jog dial control knob can be used to navigate between the menu items or change the value of a parameter (in case of TX, RX, or TRX as well). The knob can be pressed to enter a menu or edit/set a parameter.

Menu navigation & change parameter

LIGHTWARE PRO20- Panel Operation 1

  1. Turn

Menu selection & set parameter

LIGHTWARE PRO20- Panel Operation 2

  1. Press

The LCD Menu in Extender and Matrix Modes

The menu structure is different in Extender and Matrix mode. The following settings are not available in the LCD menu of the endpoint in Matrix mode but they can be set in the Matrix Management Unit:

  • Video settings – TX/RX/TRX input/output settings
  • EDID operations – EDID switching and saving
  • Network settings – static and DHCP (dynamic) IP address settings
  • Reloading factory default values

LIGHTWARE PRO20- Panel Operation 3

LIGHTWARE PRO20- Note The Extender or Matrix mode is set automatically in the endpoint device. If the device detects direct connection with another endpoint device at the other side of the connection, the mode is set to Extender mode; if the device is managed by the MMU, the mode is set to Matrix mode.

Operation Mode Settings (only in Extender Mode)

The operation mode (TX/RX/TRX) of the unit can be changed from the LCD menu in a few steps.

  1. Navigate to the System settings / Operation mode / Switch mode… submenu and select the required mode: Transmitter, Receiver, or Transceiver.
  2. After the confirmation the unit resets. After booting up the device operates in the desired mode.

Set Static IP Address (only in Extender Mode)

The IP address of the endpoint can be set from the front panel:

  1. Navigate to the System settings / Network / DHCP menu and check the current state of the DHCP. If the setting is Enabled change it to Disabled. After this navigate to Save and press Enter.
  2. Navigate to the System settings / Network / Static IP menu, and select the Static IP address, Subnet mask, Static gateway options. Set the parameters by the front panel buttons according to your network requirements.
  3. Navigate to Save and press Enter.

Set Dynamic IP Address (DHCP) (only in Extender Mode)

  1. Navigate to the System settings / Network / DHCP menu and check the current state of the DHCP. If the setting is Disabled change it to Enabled.
  2. Navigate to the Save submenu (the last one of the Network menu) and press Enter.

Restore Factory Default Settings

Navigate to the System settings / Factory defaults menu and press Enter. After the confirmation the device reboots and the factory default values are reloaded in the device.

Mounting Options

Standard Rack Installation

  1. Two mounting holes on the front ears and two on the back of the chassis is for fastening two units to each other with 2x 2 pcs M4x8 mm screws. This way you get a one-rack wide and 1U high device. 
  2. Fix the rack ears on left and right side as shown in the picture. The default position allows mounting the device as a standard rack unit.

To order rack mounting kit please contact sales@lightware.com.

See the detailed information about this mounting option in the user’s manual of the product.

LIGHTWARE PRO20- Mounting Options 1

  1. Rack ear
  2. Fixing points (2 pcs M4x8 screws)

Truss Mounting

Mounting thread on top and on one of the sides is for safe and secure installation. Rigging the handles with a safety wire rope is highly recommended for safety reasons. (Truss mounting clamp and safety wire rope are not available at sales.)

LIGHTWARE PRO20- Mounting Options 2

  1. M10x16mm screw
  2. Safety wire

See the detailed information about this mounting option in the user’s manual of the product.

Status LEDs

LIVE

Transmitter / Receiver / Transceiver

LIGHTWARE PRO20- Status LEDs 2

blinking

The device is powered and ready to use.
LIGHTWARE PRO20- Status LEDs 3

off

The device is not powered or out of operation.
STATUS

Transmitter / Receiver / Transceiver

LIGHTWARE PRO20- Status LEDs 1

on

All measured temperature and voltage values are within the limits.
LIGHTWARE PRO20- Status LEDs 2

blinking

Measured temperature or voltage value is out of the limits.
LIGHTWARE PRO20- Status LEDs 3

off

The device is not powered or out of operation.
LINK OK

Transmitter / Receiver / Transceiver

LIGHTWARE PRO20- Status LEDs 1

on

The connection is established on the fiber optical links and Link Aggregation is working.
LIGHTWARE PRO20- Status LEDs 2

blinking

The connection is established on the fiber optical links and LACP detection period is active.
LIGHTWARE PRO20- Status LEDs 3

off

No connection is established on one of the fiber optical links.
MMU AVAILABLE

Transmitter / Receiver / Transceiver

LIGHTWARE PRO20- Status LEDs 1

on

Matrix mode is active; the communication is live between the endpoint and the Matrix Management Unit (MMU).
LIGHTWARE PRO20- Status LEDs 2

blinking

Matrix mode is active; no communication between the endpoint and the MMU
LIGHTWARE PRO20- Status LEDs 3

off

Extender mode is active; another endpoint is connected via the optical link.
Connections

Transmitter (TX) Operation Mode

LIGHTWARE PRO20- Connections 1

  1. Power
  2. Laptop
  3. Touch controller
  4. 4K PC
  5. PC
  6. Monitor
  7. 4K TV

Receiver (RX) Operation Mode

LIGHTWARE PRO20- Connections 2

  1. Power
  2. Laptop
  3. Touch controller
  4. 4K PC
  5. PC
  6. Monitor
  7. Projector

LIGHTWARE PRO20- Note The HDMI input ports can be used as local input ports only.

Transceiver (TRX) Operation Mode

LIGHTWARE PRO20- Connections 3

  1. Power
  2. Laptop
  3. Touch controller
  4. 4K PC
  5. Monitor
  6. 4K TV

LIGHTWARE PRO20- Note The HDMI input 1 port cannot accept AV signal when the device is configured as transceiver.

Fiber Optical Connections

LIGHTWARE PRO20- Connections 4

  1. 2xSM-BiDi-DUO
  2. 2xMM-QUAD / 2xSM-QUAD
  3. 2xMM-2xDUO / 2xSM-2xDUO
Application Modes

Extender Mode

Point-to-point connection between a transmitter and a receiver, or between two transceiver endpoint devices.

LIGHTWARE PRO20- Warning In extender mode, an endpoint model can be connected to the same type of endpoint model. For example a 2xSM-2xDUO can be connected to another 2xSM-2xDUO.

LIGHTWARE PRO20- Connections 5

  1. UBEX transmitter
  2. UBEX receiver

Matrix Mode

Virtual AV matrix with more transmitters, receivers, transceivers, and a Matrix Management Unit (MMU) which controls the AV network.

LIGHTWARE PRO20- Connections 6

  1. UBEX transmitter
  2. UBEX receiver
  3. UBEX transceiver
  4. L3 network switch
  5. UBEX-MMU-X200 Matrix Management Unit

Transmitter (TX) Operation Mode

For all models HDMI in Connect the transmitter and the source devices (e.g. 4K PC, PC) using the HDMI input 1 and 2 ports by HDMI cables. 
Local HDMI out Connect the local sink devices (e.g. monitor, 4K TV) to the HDMI output 1 and 2 ports by HDMI cables. The output ports are local loopback ports: the same streams are transmitted which are received on the input ports.
Ethernet Optionally, connect the transmitter to a LAN in order to control the device. User Ethernet is also transmitted over the fiber optical interface so be sure not to create a network loop!
Power Connect the power adaptor to the AC input on the transmitter first, then to the AC power socket.

Receiver (RX) Operation Mode

For all models Local HDMI in Optionally, connect the UBEX receiver and the local source devices (e.g. PCs) using the HDMI input 1 and 2 ports by HDMI cables.
HDMI out Connect the sink devices (e.g. monitor, projector) to the HDMI output 1 and 2 ports by HDMI cables.
Ethernet Optionally, connect the receiver to a LAN in order to control the device. User Ethernet is also transmitted over the fiber optical interface so be sure not to create a network loop!
Power Connect the power adaptor to the AC input on the receiver first, then to the AC power socket.

Transceiver (TRX) Operation Mode

For all models HDMI in Connect the transceiver and a source devices (e.g. 4K PC) using the HDMI input 2 port by an HDMI cable.
HDMI out Connect a sink device (e.g. monitor) to the HDMI output 1 port by a HDMI cable.
Local HDMI out Connect a local sink (e.g. 4K TV) to the HDMI output 2 by an HDMI cable. The output port is a local loopback port: the same stream is transmitted which is received on the HDMI input 2 port.
Ethernet Optionally, connect the transceiver to a LAN in order to control the device. User Ethernet is also transmitted over the fiber optical interface so be sure not to create a network loop!
Power Connect the power adaptor to the AC input on the transceiver first, then to the AC power socket.

Fiber Optical Connections

2xSM-BiDi- DUO OPT SM DUO Connect the device and the remote UBEX endpoint (Extender mode) / L3 network switch (Matrix mode) by a singlemode Neutrik opticalCON DUO BiDi or 2 pcs singlemode LC fiber optical cables. The connector does not support the Neutrik opticalCON crossed fiber wiring (A-A; B-B) cable. Please use standard (A-B) cable only.
2xMM- QUAD OPT MM QUAD Connect the device and the remote UBEX endpoint (Extender mode) / L3 network switch (Matrix mode) by a multimode Neutrik opticalCON QUAD fiber optical cable.
2xSM- QUAD OPT SM QUAD Connect the device and the remote UBEX endpoint (Extender mode) / L3 network switch (Matrix mode) by a singlemode Neutrik opticalCON QUAD fiber optical cable.
2xMM- 2xDUO OPT MM DUO Connect the device and the remote UBEX endpoint(Extender mode) / L3 network switch (Matrix mode) by 2 pcs multimode Neutrik opticalCON DUO or 4 pcs multimode LC fiber optical cables.
2xSM- 2xDUO OPT SM DUO Connect the device and the remote UBEX endpoint (Extender mode) / L3 network switch (Matrix mode) by 2 pcs singlemode Neutrik opticalCON DUO or 4 pcs singlemode LC fiber optical cables.

Factory Default Settings

The following settings are applied in the device once the factory default settings are recalled:

GENERAL SETTINGS

System settings

Application mode (Extender / Matrix) Auto (the endpoint detects automatically the actual application mode)

Network settings

Static IP address – TX mode 192.168.0.101
Static IP address – RX mode 192.168.0.102
Static IP address – TRX mode 192.168.0.101
Subnet mask 255.255.255.0
Default gateway 192.168.0.1
DHCP Disabled
LW3 command protocol port 6107
HTTP port 80

HDMI PORT SETTINGS – TRANSMITTER MODE

HDMI input port properties

Scaler mode – HDMI in 1 Pass-through
FRC mode – HDMI in 2 Pass-through
Color space converter – HDMI in 1 and 2 No conversion
HDCP setting – HDMI in 1 and 2 Enabled

HDMI PORT SETTINGS – RECEIVER MODE

HDMI output port properties

Scaler mode – HDMI out 1 Pass-through
FRC mode – HDMI out 1 and 2 Pass-through
Color space converter – HDMI out 1 and 2 No conversion
Timing mode – HDMI out 1 and 2 Free run
HDCP mode – HDMI out 1 and 2 Auto

HDMI PORT SETTINGS – TRANSCEIVER MODE

HDMI input 2 port properties

FRC mode Pass-through
Color space converter No conversion
HDCP setting Enabled

HDMI output 1 port properties

Scaler mode Pass-through
FRC mode Pass-through
Color space converter No conversion
Timing mode Free run
HDCP mode Auto
Installation – First Steps

Setting the Operation Mode

All endpoint devices are manufactured as transmitter (TX) by default. Set up the operation mode for the endpoints that are to be used as receivers (RX) or transceive rs (TRX) with the front panel LCD menu.

Connecting to the Devices over LAN

LIGHTWARE PRO20- Warning Connecting the devices to the network using the factory default network settings might cause IP address conflict.

Please follow the steps before connecting the endpoint devices to the network:

  1. Set different static IP addresses or set DHCP (dynamic IP address) on the front panel LCD menu or via the Lightware Device Controller (LDC) software.
  2. Establish connection between the endpoint devices over the fiber optical interface.

Software Control – Using Lightware Device Controller (LDC)

The device can be controlled from a computer through the Ethernet ports using Lightware Device Controller. Please download the application from www.lightware.com, install on a Windows PC or a macOS and establish connection to the device.

LIGHTWARE PRO20- LDC Icon

Further information on the device is available at www.lightware.com.
The User’s Manuals are also available via the QR codes below (Extender – left; Matrix – right):

LIGHTWARE PRO20- QR code 1          LIGHTWARE PRO20- QR code 2

Contact Us
sales@lightware.com
+36 1 255 3800
support@lightware.com
+36 1 255 3810
Lightware Visual Engineering PLC.
Budapest, Hungary