LIGHT-LOGO

LIGHT SKY MAMBA LED Light Par with Simple Design

LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design-PRODUCT

Specifications

  • Brand: MAMBA
  • Address: No. 43, Yunfeng Road, Xiuquan Street, Huadu District, Guangzhou, China

Product Information

Congratulations on choosing our company product! We thank you for your custom. Please keep in mind that this product, like other products of the company, adheres to the concept of people-oriented design and manufacture, and takes product quality as the foundation. We put the interests of customers first, and do our best to meet customer requirements. Please read this instruction manual carefully and keep it for future reference. In the case o fully understanding the product information, strictly abide by the instruction manual to ensure that the product is installed, used, and serviced correctly and safely. Our company is not responsible for any damage to lamps or other performance due to personal failure to follow the instructions during installation, use, and maintenance. Our company reserves the right to modify the manual at any time and without prior notice.

Safety Instructions
Please read the instruction carefully which includes important information about the installation, usage, and maintenance. Ensure the following safety measures:

  • Keep the User Manual for future reference.
  • Ensure qualified operators handle installation and operation.
  • Use safety chains when fixing the unit.
  • Handle the unit by carrying its base instead of head only.
  • Ensure proper ventilation during installation.

Technical Specifications
The technical specifications of the product include:

  • Attachment And Size: Refer to section 2.1 for detailed information.
  • Control Panel: Refer to section 3 for details on operation.
  • Connection and Control: Refer to section 5 for guidance on connecting and controlling the unit.

How To Set The Unit
To set up the unit, follow these steps:

  1. Refer to the Main Function in section 4.1 for primary operations.
  2. Connect the unit as described in section 5.
  3. Operate the control panel as per section 3.

FAQ

Q: What should I do if the unit overheats?
A: Ensure proper ventilation and check for blocked ventilation slots. If the issue persists, contact a qualified service agent.

FLY DRAGON LIGHTING EQUIPMENT CO.,LTD

LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (1)

Congratulations on choosing our company product! We thank you for your custom.

  • Please keep in mind that this product, like other products of the company, adheres to the concept of people-oriented design and manufacture, and takes product quality as the foundation.
  • We put the interests of customers first, and do our best to meet customer requirements.
  • Please read this instruction manual carefully and keep it for future reference. In the case of fully understanding the product information, strictly abide by theUse the instruction manual to ensure that the product is installed, used and serviced correctly and safely.
  • Our company is not responsible for any damage to lamps or other performance due to personal failure to follow the instructions during installation, use and maintenance.responsibility.
  • Our company reserves the right to modify the manual at any time and without prior notice.

Safety Instructions

Please read the instruction carefully which includes important information about the installation, usage and maintenance.

WARNING
Please keep this User Manual for future consultation. If you sell the unit to another user, be sure that they also receive this manual.
The following symbols are used to identify important safety information on the product and in this manual:

LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (2) Important
Damages caused by the disregard of this user manual are not subject to warranty. The dealer will not accept liability for any resulting defects or problems.

  • The equipment is only suitable for indoor dry place use.
  • Unpack and check carefully to ensure that there is no transportation damage before using the unit.
  • Do install and operate by qualified operator.
  • The light source in this luminaire should be replaced by the manufacturer or its service agent or a similarly qualified person, always cut off the power supply before replacing he light source.
  • Do not allow children to operate the fixture.
  • Use safety chain when fixing the unit. Handle the unit by carrying its base instead of head only.
  • The unit must be installed in a location with adequate ventilation, at least 20cm from adjacent surfaces.
  • Be sure that no ventilation slots is blocked, otherwise the unit will be overheated.
  • Before operation, ensure that you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product’s specification label.
  • It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.
  • Minimum ambient temperature Ta: -10℃. Maximum ambient temperature Ta: 45℃. Do not operate this product at a lower or higher temperature.
  • Do not connect the device to any dimmer pack.
  • When the lamp is running, do not place combustible objects next to it. The shortest distance between the device and inflammable and explosive objects or materials is 0.5m.
  • Make sure the power cord is not crimped or damaged; replace it immediately if damaged.
  • Unit’s surface temperature may reach up to 80℃. do not touch the housing bare-handedduring its operation.
  • Avoid any flammable liquids, water or metal from entering the unit. Once it happens, cut off the mains power immediately.
  • Do not operate in a dirty or dusty environment. do clean the fixture regularly.
  • Do not touch any wire during operation as there might be a hazard of electric shock.
  • Avoid entanglement of the power cord with other wires.
  • The minimum distance to objects/surface must be more than 3 meters.
  • In the event of serious operating problem, stop using the unit immediately.
  • Never turn on and off the unit time after time.
  • The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged.
  • Do not open the housing as there are no user serviceable parts inside.
  • Do not attempt to operate this unit if it becomes damaged. do not attempt any repairs yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center if needed.
  • Disconnect this product from its power source before servicing.
  • Do use the original packaging if the device is to be transported.
  • Avoid direct eye exposure to the light source while the product is on.
  • Do not operate this product if you see damage on the housing, shields, or cables. Have the damaged parts replaced by an authorized technician at once.

Installation

The fixture should be fixed on the clamp. always ensure that the unit is firmly fixed to avoid vibration and slipping off during operation. ensure that the trussing or area of installation must be able to hold 10 times the weight without any deformation. Always install a safety cable that can hold at least 12 times the weight of the fixture when installing.do install and operate by qualified operator. It must be installed in a place where there is out of the reach of people.

Technical Specifications

OPTICS

  • Light source: 12*40W LED chip RGBW 4 in 1
  • Beam angle: 3.6°-38°
  • Zoom angle: 4.2°-53°
  • Color Temperature: 2200K-8000K
  • Light Luminous Flux: 18460 lux@5 meters

EFFECT

  • Color Mixing System: uniform RGBW color mixing and rainbow effect
  • Zoom system: Linear electronic zoom
  • Individual Controlled: support individual controlled, varied in color and effect
  • effect macro: static and dynamic
  • Dimmer: Linear electronic dimmer, provides four dimming options
  • Strobe: 1-30Hz electronic strobe and random strobe

CONTROL AND PROGRAMMING

  • Controlled Channel:19CH(Standard),64CH(Extended),see channel table for details
  • Control Mode: DMX512, RDM, ART-NET
  • Data connection: RJ45 input and output, 3-pin and 5-pin input and output
  • Display: LCD Lattice screen

SOFTWARE

  • Upgrade:Upgrade software through DMX signal interface and USB interface
  • Intelligent temperature control to ensure long lifespan of LED

PAN/TILT MOVEMENT

  • Tilt movement:185°16 bit precision

POWER AND VOLTAGE

  • Input voltage: AC 100-240V 50/60Hz
  • Power: 425W PF:>0.98

SIZE AND WEIGHT

  • Light Size: 1003mm×126mm×308mm
  • N.W: 20.3 kg
  • Carton size: 1110mm×410mm×215mm
  • G.W: 24.0 kg
  • Flycase (option-3 sets) :1075mm×680mm×495mm
  • N.W: 60.9 Kg G.W: 100.4 Kg

OTHERS

  • IP rate: IP20
  • Working environment: -10℃ ~ 45℃
  • Maximum temperature of fixture body surface: 80℃
  • Maximum on-line quantity: 2pcs/110V 4pcs/220V
  • Maximum current: 1.9A/220V;4.3A/110V
  • Optional material: light hook

APPROVALS

  • The product implementation standard: GB 7000.1-2015 GB7000. 217-2008
  • Approved certifications: CE、RoHs
  • The product complies with the following EU directives:
  • Low Voltage Directive 2014/35/EU . EMC Directive 2014/30/EU

LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (3) LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (4)

Attachment And Size
Attachment contents-Fig.1

LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (5)

Size-Fig.2

LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (6)

Control Panel

LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (7)

  1. Display: To show the various menus and the selected function.
  2. Button:
  3. LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (8)Power input: connect to the power supply.
  4. Power output: connect to the lamp power output adapter.
  5. DMX input: for DMX512 connection, use 3 or 5-core XLR signal cable to connect console and lamps,and input DMX signal.
  6. DMX output: used for DMX512 connection, use 3 or 5-core XLR signal cable to connect console and lamps,And output DMX signal.
  7. ART-NET input/output: The information of the luminaire can be transmitted to the main controller through the network cable, and the luminaire can be controlled through Rj45.
  8. USB socket: for updating software version.
  9. Lamp connection lock position (front)
  10. Lamp connection lock position (back)

How To Set The Unit

Main Function
After starting up, press any key to enter the preset menu interface, use the up/down/left/right keys to select: DMX settings, basic information, personality settings, manual control, service options, test lamps, language, screen rotation, press OK Confirm and enter the lower menu.

  • LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (9) – DMX settings
    Enter the Preset menu interface, selectLIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (9) Function, press the OK key to enter the lower menu, use  the Up/Down key to select the ② level menu: DMX address, signal priority, AreNet setting, exit.
  • ②DMX address:
    Select the DMX address function, press the OK key to enter the lower-level menu, press the up/down key, you can choose to set the address code (001~512) of the lamp according to the current channel mode, and press the left/right key to fine-tune the address code. Press OK to confirm the settings and return to the previous menu.
  • ②DMX/Artnet:
    Select the DMX/Artnet function, press the OK button to enter the lower menu, press the up/down button, you can choose: DMX priority (default), ARTNET priority, press the OK button to confirm the setting and return to the upper menu, or press the left/right button to Returns to the previous menu without changing the current selection.
  • ② ArtNet Set:
    Select the ArtNet Set function, press the OK key to enter the lower-level menu, press the Up/Down key to select: IP address, Mask address, Net address, Sub Net address, Universe address, and exit. Press the OK key to enter the lower level menu, or press the left/right key to return to the upper level menu.
  • ③ IP address:
    Select the IP address function, press the OK key to enter the sub-menu, press the left/right key to select the address code number segment to be set, and press the up/down key to adjust the number of the number segment. Press OK to confirm the settings and return to the previous menu.
  • ③Mask address:
    Select the Mask address function, press the OK key to enter the lower-level menu, press the left/right key to select the address code number segment to be set, and press the up/down key to adjust the number of the number segment. Press OK to confirm the settings and return to the previous menu. ③Net address:
    Select the Net address function, press the OK key to enter the submenu, and press the Up/Down key to adjust the Net address code (001~128). Press OK to confirm the settings and return to the previous menu.
  • ③Sub Net address:
    Select the Sub Net address function, press the OK key to enter the sub-menu, and press the
    Up/Down key to adjust the Sub Net address code (001~015). Press OK to confirm the settings and return to the previous menu.
  • ③Universe address:
    Select the Universe address function, press the OK key to enter the submenu, and press the
    Up/Down key to adjust the universe address code (001~015). Press OK to confirm the settings and return to the previous menu.
  • LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (10) – Information
    Enter the preset menu interface, select function, pressLIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (10) the OK key to enter the lower menu, use the up/down keys to select the ② level menu: total running time, equipment time, equipment temperature, RDM address, fan voltage, equipment channel, version information, quit.
  • ②Total Time
    Select the Total Time function of total running time, press the OK key to enter the sub-menu, and you can view the equipment: always powered on (H), always on (H). Press OK or Left/Right to return to the previous menu.
  • ②Led hours
    Select the Led hours function, press the OK key to enter the sub-menu, you can view the device: power-on time (H), lighting time (H). Press OK or Left/Right to return to the previous menu.
  • ② Temperature
    Select the Temperature function, press the OK key to enter the lower-level menu, and you can view the temperature of the device: driver board 1, light source 1, driver board 2, and light source 2 (unit:°C). Press OK or Left/Right to return to the previous menu.
  • ② RDM UID
    Select the RDM UID function, press the OK key to enter the submenu, and you can view the device: RDM address information. Press OK or Left/Right to return to the previous menu.
  • ② Fan voltage
    Select the Fan voltage function, press the OK key to enter the sub-menu, you can view the equipment: cooling fan 1, cooling fan 2 voltage. Press OK or Left/Right to return to the previous menu. ② DMX live
    Select the DMX live function, press the OK key to enter the submenu, and you can view the device: channel information in the current channel mode. Press OK or Left/Right to return to the previous menu.
  • ② System version
    Select the System version function, press the OK key to enter the lower-level menu, and you can view the version information of the device: display board, Y-axis board, zoom 1, zoom 2, light board 1, and light board 2. Press OK or Left/Right to return to the previous menu.
  • LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (11)– Personal
    Enter the preset menu interface, selectLIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (11) function, press the OK button to enter the lower menu, use the up/down button to select the ② level menu: channel mode, interface display password, dimming curve, LED sequence reverse,display setting, Led frequency setting,Fan mode, exit, press OK key to enter the lower menu, or press the left/right key to return to the upper menu.
  • ②Channel mode
    Select the Channel mode function, press the OK key to enter the lower menu, you can use the up /down keys to select: standard mode (19CH) (default), extended mode (64CH), press the OK key to confirm the selection and return to the upper menu.
  • ② Display lock
    Select the Display lock function, press the OK key to enter the submenu, press the up/down key to select: on, off (default), press the OK key to confirm Select and return to the previous menu. (Note: The interface password function only works for the DMX setting function, password: 2222)
  • ② Dimmer Curve
    Select the Dimmer Curve function, press the OK key to enter the lower menu, you can use the Up/Down keys to select: linear (default), square curve, inverse square curve, S curve, press the OK key to confirm the selection and return to the upper menu.
  • LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (12)②LED sequence reverse
    Select the LED sequence reverse function of setting the sequence of light beads in reverse, press the OK key to enter the lower menu. You can use the up/down keys to select: close/open, press the OK key to confirm the selection and return to the upper menu.
  • ② Display
    Select the Display setting function, press the OK key to enter the submenu, you can use the up/down key to select the ③ level menu: language (Language), backlight, screen rotation, backlight flashing, exit, press the OK key to enter the submenu, or press the left button Return to previous menu.
  • ③ Language
    Select the Language function, press OK key to enter the lower menu, you can use the up / down keys to select: English , Chinese (default), press OK key to confirm the selection and return to the upper menu.
  • ③Backlight
    Select the Backlight function, press the OK key to enter the lower menu, you can use the up/down keys to select: constant light, automatic off (30S) (default), press the OK key to confirm and return to the upper menu.
  • ③ Reversal
    Select the Reversal function, press the OK key to enter the lower menu, you can use the up / down keys to select: normal (default), rotate 180 degrees, press the OK key to confirm and return to the upper menu.
  • ③ Backlight blink
    Select the Backlight blink function, press the OK key to enter the submenu, you can use the up / down keys to select: open (default), close, press the OK key to confirm and return to the previous menu.
  • ② Led Preq Set
    Select the Led Preq Set function, press the OK button to enter the lower menu, you can use the up/down button to select the ③ level menu: 1000 Hz, 3600 Hz, 7200 Hz, 25000 Hz (default), press the OK button to confirm the selection and return to the upper menu, Pressing Left/Right only returns to the previous menu without changing the current selection.
  • ② Fan mode
    Select the fan mode function, press the OK key to enter the lower-level menu, you can use the
    up/down keys to select the③ menu: high speed, silent, press the OK key to confirm the selection and return to the upper-level menu, press the left/right key to only return to the upper-level menu, not Change the current selection.
  • ② Dimming mode
    Select the dimming mode function, press the OK key to enter the lower menu, and use the up/down keys to select the ③ level menu: fast and smooth, press the OK key to confirm the selection and return to the upper menu, press the left/right keys to only return to the upper menu, without changing the current selection.
  • LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (13)– Manual control
    Enter the preset menu interface, selecLIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (13)t function, press the OK key to enter the submenu, you can use the up/down key to select the ② level menu: channel control, reset, exit, press the OK key to enter the submenu, or press the left/right key to Return to previous menu.
  • ② Channel control
    Select the Channel control function, press the OK key to enter the sub-menu, press the up / down key to select each channel of the current channel mode, press the left / right key to manually adjust the DMX value of each channel from 0 to 255, press the OK key Return to the previous menu, and at the same time, the lamp is reset to the state just turned on.
  • ② Reset
    Select the Reset function, press the OK key to enter the lower menu, you can use the up / down keys to select: system reset (that is, the whole machine reset), vertical reset, zoom reset, exit, press the OK key to confirm and execute the selected reset command, and return Previous menu, or press
    Left/Right to return to previous menu only.
  • LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (14)– Service
    Enter the preset menu interface, select LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (14)function, press the OK key to enter the submenu, you can use the up/down key to select: current fault information, clear fault information, calibration, factory settings, exit, press the OK key to enter the submenu, or press the Left/Arrow only returns to previous menu.
  • ② Error list
    Select the Error list function, press the OK key to enter the lower-level menu, you can view the fault records of the whole machine, press the OK key or the left/right key to return to the upper-level menu.
  • ② Clean error
    Select the Clean error function, press the OK key to enter the lower menu, use the up/down keys to select: no clear (default), clear, you can clear or keep the fault records of the lamp, press the OK key to confirm clearing the fault information and return to the upper menu , or press Left/Right to return to the previous menu without changing the current selection.
  • ②Calibration
    Select the Calibration function, press the OK key to enter the lower menu, press the up/down key to select each channel of the current channel mode, press the left/right key to manually fine-tune the DMX value of each channel from 0 to 255 (default 128), press OK key to confirm and return to the previous menu.
  • ② Factory
    Select the Factory function, press the OK key to enter the submenu, you can use the up / down keys to select: factory default, time clear, developer, software upgrade, exit, press the OK key to enter the submenu. Note that the functions under this menu require a password to proceed to the next step.
  • LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (15)– Test
    Enter the preset menu interface, selectLIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (15) function, press the OK key to enter the submenu, you can use the up/down key to select: test vertical, test the head effect, overall test, exit, press the OK key to enter the submenu, and the lamp starts to execute Test instructions. Or press Left/Right to return to previous menu only.
  • LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (16)– Language
    Enter the Preset Menu interface, select LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (16) Function, and press OK to switch between Chinese (default) and English.
  • LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (17)– Reversal
    Enter the Preset Menu interface, select LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (17)Function, and press OK to switch the screen between: normal and rotated 180 degrees.

LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (18)

Main menu I menu II menu III menu Ⅳ menu
 

 

 

 

 

 

DMX Address

 

 

 

 

 

 

Address:001-512
 

DMX/ARTNET

 

DMX Priority
ARTNET Priority
 

 

 

ArtNet Set

 

 

 

IP Address xxx.xxx.xxx.xxx
Mask Address xxx.xxx.xxx.xxx
Net Address 1-128
Sub Net Address 0-15
Universe Address 0-15
Return(ESC)
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Information

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total Time

 

Power:****(h)
Led ON:****(h)
 

Led hours

 

Total:****(h)
Led open:****(h)
 

 

Temperature

 

 

Borad 1:00.0
LED 1:00.0
Borad 2:00.0
LED 2:00.0
RDM UID RDM UID 3888:00000000
 

FanVoltag

 

LEDFan1 00.0V
LEDFan2 00.0V
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DMX live

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Dimmer 000-255
2.DimmerFine 000-255
3.strobe 000-255
4.Red 000-255
5.Green 000-255
6.Blue 000-255
7.White 000-255
8.CCT 000-255
9.Inter Program 000-255
10.Program Speed 000-255
11.Dimmer of Back Color(for Program) 000-255
12. Red of Back Color(for

Program) 000-255

13. Green of Back Color(for Program) 000-255
14.Blue of Back Color(for

Program) 000-255

15.White of Back Color(for Program) 000-255
16.ZOOM left segment 000-255
17.TILT 000-255
18.TILT FINE 000-255
19.RESET 000-255
 

 

 

 

System version

 

 

 

 

Display
Y Board
Zoom1
Zoom2
LED1
LED2
Return(ESC)
 

Channel mode

 

Standard(19CH)
Extended(64CH)
 

Display lock

 

OFF
ON
Main menu I menu II menu III menu Ⅳ menu
 

 

 

 

 

 

 

 

 

 

 

 

 

Personal

 

 

Dimmer Curve

 

 

Linear(Default)
Square
I-Square
SCurve
 

LED invert

 

OFF
ON
 

 

 

 

 

 

Display

 

 

 

 

 

 

 

Language

 

English
Chinese
 

BackLight

 

Open
Auto close(30s)
 

Reversal

 

Normal
Rota.180
 

Backlight blink

 

ON
OFF
Return(ESC)
 

 

Led Preq Set

 

 

1000 Hz
3600 Hz
7200 Hz
25000 Hz
 

Fan mode

fast
silence
 

Dim mode

fast
smooth
Return(ESC)
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Channel control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Dimmer 000-255
2.DimmerFine 000-255
3.strobe 000-255
4.Red 000-255
5.Green 000-255
6.Blue 000-255
7.White 000-255
8.CCT 000-255
9.Inter Program 000-255
10.Program Speed 000-255
11.Dimmer of Back Color(for Program) 000-255
12. Red of Back Color(for

Program) 000-255

13. Green of Back Color(for Program) 000-255
14.Blue of Back Color(for

Program) 000-255

15.White of Back Color(for Program) 000-255
16.ZOOM left segment 000-255
17.TILT 000-255
18.TILT FINE 000-255
19.RESET 000-255
Return(ESC)
 

 

Reset

 

 

system reset
Tilt reset
Zoom reset
Return(ESC)
Return(ESC)
 

Error list

 

ZOOM1
ZOOM2
TILT
Main menu I menu II menu III menu Ⅳ menu
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Service

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean error

 

Yes  

(code:2222)

No
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Calibration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tilt 000-255
Zoom1 000-255
Zoom2 000-255
Red1 000-255
Green1 000-255
Blue1 000-255
White1 000-255
Red2 000-255
Green2 000-255
Blue2 000-255
White2 000-255
Red3 000-255
Green3 000-255
Blue3 000-255
White3 000-255
Red4 000-255
Green4 000-255
Blue4 000-255
White4 000-255
Red5 000-255
Green5 000-255
Blue5 000-255
White5 000-255
Red6 000-255
Green6 000-255
Blue6 000-255
White6 000-255
Red7 000-255
Green7 000-255
Blue7 000-255
White7 000-255
Red8 000-255
Green8 000-255
Blue8 000-255
White8 000-255
Red9 000-255
Green9 000-255
Blue9 000-255
White9 000-255
Red10 000-255
Green10 000-255
Blue10 000-255
White10 000-255
Red11 000-255
Green11 000-255
Blue11 000-255
White11 000-255
Red12 000-255
Green12 000-255
Blue12 000-255
White12 000-255
Main menu I menu II menu III menu Ⅳ menu
Return(ESC)
 

 

 

 

 

 

 

 

 

Factory

 

 

 

 

 

 

 

 

 

Defualt
 

Time clean

 

Total Time
Device Time
Led Time
 

 

 

 

 

Developer

 

 

Manual OR DMX

DMX Control
Manual Control
Load font
 

 

LOGO select

LIGHT SKY
Custom LOGO
No LOGO
LOGO upgrade
Return(ESC)
Firmware update
Return(ESC)
Return(ESC)
 

 

test

 

 

Test T STEP ***
Test effect STEP ***
Test all STEP ***
Return(ESC)
 

Language

 

English
Chinese
 

Reversal

 

Normal
Rota.180

Connection and control

Power supply connection

LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (19)

  • The bus connecting the power supply must be installed by a qualified professional technician.
  • After completing all the above operations and ensuring that it is installed, you can power on the lamp to operate.

DMX 512 Connection

LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (20)

  1. At last unit, the DMX cable has to be terminated with a terminator. Solder a 1200hm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit.
  2. Connect the unit together in a “daisy chain” by XLR plug cable from the output of the unit to
    the input of the next unit. The cable cannot be branched or split to a “Y” cable. DMX 512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system.
  3. The DMX output and input connectors are pass-through to maintain the DMX circuit, when one of the units’ power is disconnected.
  4. Each lighting unit needs to have a DMX address to receive the data by the controller. The address number is between 1-512.
  5. The end of the DMX 512 system should be terminated to reduce signal errors.
  6. 3 pin XLR connectors are more popular than 5 pins XLR.
    • 3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
    • 5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin4, Pin5 not used.

Channel Setting
Enter the MENU menu, select the Personal Settings function, select the channel mode, press the OK button to confirm, you can use the up and down keys to select: 19channels (default), 64 channels, Press the OK key to enter the selection confirmation and return to the previous menu.

Address SettingAddress Setting
Enter MENU, select the DMX setting function, select the address code setting, press the OK button to confirm, the current DMX address will be displayed on the display. Use the up/down buttons to select addresses 001~512, and press the OK button to save. Press the OK button to return to the previous menu.
Please refer to the following diagram to address your DMX512 channel for the first 4 units.

Channel mode Unit 1 Address Unit 2 Address Unit 3 Address Unit 4 Address
19 CH 1 20 39 58
64 CH 1 65 129 193

DMX 512 Configuration

64 Channel 19 Channel DMX Function Note
1 1  

0-255

Dimmer

Light output linearly increase from off to maximum brightness

2 2  

0-255

Dimmer Fine

Fine Dimmer positioning

 

 

3

 

 

3

 

0 – 9

10 – 194

195 – 199

200 – 249

250 – 255

Strobe

Close

Strobe from slow to fast Open

Random strobe from slow to fast

Open

4 4  

0-255

RED 1

Red1 colour linearly increase from no-light to maximum intensity

5 5  

0-255

GREEN 1

GREEN1 colour linearly increase from no-light to maximum intensity

6 6  

0-255

BLUE 1

BLUE1 colour linearly increase from no-light to maximum intensity

7 7  

0-255

White 1

White1 colour linearly increase from no-light to maximum intensity

8 /  

0-255

RED 2

Red2 colour linearly increase from no-light to maximum intensity

9 /  

0-255

GREEN 2

GREEN2 colour linearly increase from no-light to maximum intensity

10 /  

0-255

BLUE 2

BLUE2 colour linearly increase from no-light to maximum intensity

11 /  

0-255

White 2

White2 colour linearly increase from no-light to maximum intensity

12 /  

0-255

RED 3

Red3 colour linearly increase from no-light to maximum intensity

13 /  

0-255

GREEN 3

GREEN3 colour linearly increase from no-light to maximum intensity

14 /  

0-255

BLUE 3

BLUE3 colour linearly increase from no-light to maximum intensity

15 /  

0-255

White 3

White3 colour linearly increase from no-light to maximum intensity

16 /  

0-255

RED 4

Red4 colour linearly increase from no-light to maximum intensity

17 /  

0-255

GREEN 4

GREEN4 colour linearly increase from no-light to maximum intensity

18 /  

0-255

BLUE 4

BLUE4 colour linearly increase from no-light to maximum intensity

19 /  

0-255

White 4

White4 colour linearly increase from no-light to maximum intensity

20 /  

0-255

RED 5

Red5 colour linearly increase from no-light to maximum intensity

21 /  

0-255

GREEN 5

GREEN5 colour linearly increase from no-light to maximum intensity

22 /  

0-255

BLUE 5

BLUE5 colour linearly increase from no-light to maximum intensity

23 /  

0-255

White 5

White5 colour linearly increase from no-light to maximum intensity

24 /  

0-255

RED 6

Red6 colour linearly increase from no-light to maximum intensity

25 /  

0-255

GREEN 6

GREEN6 colour linearly increase from no-light to maximum intensity

26 /  

0-255

BLUE 6

BLUE6 colour linearly increase from no-light to maximum intensity

27 /  

0-255

White 6

White6 colour linearly increase from no-light to maximum intensity

28 /  

0-255

RED 7

Red7 colour linearly increase from no-light to maximum intensity

29 /  

0-255

GREEN 7

GREEN7 colour linearly increase from no-light to maximum intensity

64 Channel 19 Channel DMX Function Note
30 /  

0-255

BLUE 7

BLUE7 colour linearly increase from no-light to maximum intensity

31 /  

0-255

White 7

White7 colour linearly increase from no-light to maximum intensity

32 /  

0-255

RED 8

Red8 colour linearly increase from no-light to maximum intensity

33 /  

0-255

GREEN 8

GREEN8 colour linearly increase from no-light to maximum intensity

34 /  

0-255

BLUE 8

BLUE8 colour linearly increase from no-light to maximum intensity

35 /  

0-255

White 8

White8 colour linearly increase from no-light to maximum intensity

36 /  

0-255

RED 9

Red9 colour linearly increase from no-light to maximum intensity

37 /  

0-255

GREEN 9

GREEN9 colour linearly increase from no-light to maximum intensity

38 /  

0-255

BLUE 9

BLUE9 colour linearly increase from no-light to maximum intensity

39 /  

0-255

White 9

White9 colour linearly increase from no-light to maximum intensity

40 /  

0-255

RED 10

Red10 colour linearly increase from no-light to maximum intensity

41 /  

0-255

GREEN 10

GREEN10 colour linearly increase from no-light to maximum intensity

42 /  

0-255

BLUE 10

BLUE10 colour linearly increase from no-light to maximum intensity

43 /  

0-255

White 10

White10 colour linearly increase from no-light to maximum intensity

44 /  

0-255

RED 11

Red11 colour linearly increase from no-light to maximum intensity

45 /  

0-255

GREEN 11

GREEN11 colour linearly increase from no-light to maximum intensity

46 /  

0-255

BLUE 11

BLUE11 colour linearly increase from no-light to maximum intensity

47 /  

0-255

White 11

White11 colour linearly increase from no-light to maximum intensity

48 /  

0-255

RED 12

Red12 colour linearly increase from no-light to maximum intensity

49 /  

0-255

GREEN 12

GREEN12 colour linearly increase from no-light to maximum intensity

50 /  

0-255

BLUE 12

BLUE12 colour linearly increase from no-light to maximum intensity

51 /  

0-255

White 12

White12 colour linearly increase from no-light to maximum intensity

 

52

 

8

 

0-19

20-255

CCT

Invalid

2200K – 8000K

 

 

 

 

 

 

 

 

 

 

 

 

53

 

 

 

 

 

 

 

 

 

 

 

 

9

 

0 – 7

8   – 15

16  – 23

24  – 31

32  – 39

40  – 47

48  – 55

56  – 63

64  – 71

72  – 79

80  – 87

88  – 95

96   – 103

104  – 111

Inter Program

Invalid

Scenes 1

Scenes 2

Scenes 3

Scenes 4

Scenes 5

Scenes 6

Scenes 7

Scenes 8

Scenes 9

Scenes 10

Scenes 11

Scenes 12

Scenes 13

64 Channel 19 Channel DMX Function Note
112  – 119

120 – 127

128 – 135

136 – 143

144 – 151

152 – 159

160 – 167

168 – 175

176 – 183

184 – 191

192 – 199

200 – 207

208 – 215

216 – 223

224 – 231

232 – 239

240 – 247

248 – 255

Scenes 14

Scenes 15

Scenes 16

Scenes 17

Scenes 18

Scenes 19

Scenes 20

Scenes 21

Scenes 22

Scenes 23

Scenes 24 Rainbow1 Rainbow2 Rainbow3 Rainbow4 Invalid Invalid Invalid

 

54

 

10

 

0-127

128-255

Program Speed

slow to fast (without fade) slow to fast (with fade)

55 11 0-255 Dimmer of Back Color(for Program)
56 12 0-255 Red of Back Color(for Program)
57 13 0-255 Green of Back Color(for Program)
58 14 0-255 Blue of Back Color(for Program)
59 15 0-255 White of Back Color(for Program)
60 16  

0-255

ZOOM left segment

Zoom linearly moves from narrow to wide beam

61 /  

0-255

ZOOM right segment

Zoom linearly moves from narrow to wide beam

62 17  

0-255

TILT

Moving batten linearly tilts from 0° to 190°

63 18  

0-255

TILT FINE

Tilt Fine positioning

 

 

 

 

 

 

 

 

 

 

 

 

64

 

 

 

 

 

 

 

 

 

 

 

 

19

0 – 9

10-19

20-29

30- 39

40-49

50-59

60-69

70-79

80-89

90-99

100-109

110 -119

120-129

130-139

140-149

150-159

160-209

RESET

Free

System Reset Tilt Reset Zoom Reset Linear(Default) Square

I-Square SCurve 1000 Hz

3600 Hz

7200 Hz

25000 Hz

LED Flip on LED Flip off Fast dimmer Smooth dimmer

Free

 

 

210-219

Enable DMX Controller Fix the White Balance.

In the extended mode, TiltCH==127 and Tilt FineCH ==127 and ProgramCH ==0 and Program speedCH == 127, keep it still for 3 seconds, then turn on the console to correct the white balance and continue to keep the conditions unchanged (vertical==127 and vertical trim==127 and built-in program==0 and built-in built-in

program speed==127)

220-229

240-249

250 – 255

Save the WhiteBalance Value & disable DMX Controller Fix the WhiteBalance.

Fan&Zoom fast mode

Fan&Zoom silence mode

Electrical Connection Diagram

LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (21)

The position of each fan of the fixture:

LIGHT-SKY-MAMBA-LED-Light-Par-with-Simple-Design- (22)

Troubleshooting

Following are a few common problems that may occur during operation. Here are some suggestions for troubleshooting:

A. The unit does not work, no light and the fan does not work

  • Check the connected power.
  • Measure the voltage.
  • Check the power indicator to see whether it can be lit up or not.

B. Not responding to the DMX controller

  • Check whether the DMX connectors and the DMX cables are connected correctly.
  • Check whether the DMX address is correctly set.
  • If the intermittent DMX signal problem occurs, check whether the XLR socket and the signal cable are well connected.
  • Try it with another DMX controller.
  • Check whether the DMX cables run near or alongside to the high-voltage cables, which may damage or interfere with the signal circuit.

Fixture Cleaning

It is absolutely essential that the fixture is kept clean to ensure the maximum light-output and allow the fixture to function reliably throughout its life. The fixture must be cleaned regularly to avoid dust, dirt and smoke-fluid residues building up on or within the fixture. The cleaning frequency depends on the application environment. Clean the fixture immediately if the dust enters it to avoid damage to the optical lens due to excessive dust.

  • A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances should solvents be used.
  • Always dry the parts carefully.
  • Clean the external optical lens at least every 20 days and the internal optical lens every 30 days.

CAUTION !!!
Disconnect from mains before starting maintenance operation.

Duty exonerative and copyright protectio

  • Light source belongs to consumption products, not within the scope of warranty.
  • The manufacturer shall not bear any responsibility for any damage caused by failure to operate in accordance with this instruction.
  • All the information in this manual shall be interpreted by the manufacturer.
  • All the information in this manual shall not be copied without permission.
  • The data contained in this statement are subject to change in the future without prior notice.

Documents / Resources

LIGHT SKY MAMBA LED Light Par with Simple Design [pdf] User Manual
MAMBA LED Light Par with Simple Design, MAMBA, LED Light Par with Simple Design, Light Par with Simple Design, with Simple Design, Simple Design, Design

References

Leave a comment

Your email address will not be published. Required fields are marked *