LMOD-A109 Drying Oven
“
Specifications
- Model No.: LMOD-A109
- Capacity: [Specify capacity]
- Temperature Range: [Specify range]
- Temperature Resolution: [Specify resolution]
- Temperature Fluctuation: [Specify fluctuation]
- Timer: Yes
- Power Consumption: [Specify consumption]
- Power Supply: [Specify supply]
- Working Dimensions: [Specify dimensions]
- Packaging Dimensions: [Specify dimensions]
- Net Weight: [Specify weight]
- Gross Weight: [Specify weight]
Product Usage Instructions
Safety Measures
Ensure the drying oven is used in a well-ventilated area and
away from humid conditions to prevent hazards.
Introduction
The Drying Oven LMOD-A109 is designed for drying, heating, and
sterilizing samples in laboratory and industrial settings.
Features
- Digital Timer Display
- Semicircle Chamber Corners
- Over Temperature Alarm
- Automatic Operation Alarm
Applications
Ideal for moisture removal, thermal processing, and material
testing in pharmaceutical and electronic industries.
Structure Introduction
[Describe the structure of the drying oven here]Operations
- Place the drying materials in the working chamber and close the
door. - Plug in the power source.
- Set the desired working temperature and allow the chamber to
stabilize. - Select the appropriate drying time based on your needs.
- Turn off the power switch after the process is complete but
wait before opening the door to avoid burns.
Troubleshooting
Phenomena | Reason | Treatment |
---|---|---|
No electricity | Not connecting the power supply well or wire breaks | Check and reconnect the power supply wire. |
Circuit Diagram
[Include circuit diagram image or description here]Frequently Asked Questions (FAQ)
Q: How do I adjust the temperature on the Drying Oven
LMOD-A109?
A: To adjust the temperature, use the temperature control
settings on the oven. Refer to the user manual for detailed
instructions.
“`
Operational Manual
Drying Oven LMOD-A109
www.labmate.com | info@labmate.com
Sr.no 1. 2. 3. 4. 5. 6. 7. 8. 9.
Drying Oven LMOD-A109 Index
Title Safety Measures
Introduction Features
Specifications Applications Structure Introduction Operations Troubleshooting Circuit Diagram
Page no 2 3 3 3 3 4 5 6 7
1
Drying Oven LMOD-A109 1. Safety Measures
· To avoid electrical dangers, ensure the drying oven’s outside shell is correctly grounded.
· If the device will not be used for a long time, unplug it and turn off the power supply after use.
· Do not put anything flammable, volatile, or explosive within the drying oven chamber because it is not explosion-proof.
· Any combustible or explosive products should not be kept on or close to the oven. · The drying oven should be placed away from heat sources and direct sunshine in
a well-ventilated location. · To ensure optimum ventilation and avoid overheating, keep enough space around
the oven. · To maintain a consistent temperature and stop heat loss, make sure the oven door
is completely closed while it is operating. · To ensure uniform airflow and effective hot air circulation, leave enough space
between samples and avoid blocking the chamber’s air vents. · To avoid burns, wear gloves that can withstand heat when handling things inside
the heated chamber. · Avoid opening the door too often while the machine is operating, as this could lead
to temperature changes and impair drying efficiency. · Clean the internal chamber on a regular basis to avoid debris accumulation that
could obstruct heat transfer. · Only trained professionals should do repairs or servicing on the oven; do not alter
or tamper with its parts. · The oven may sustain internal component damage if it is used in corrosive or
humid conditions.
2
Drying Oven LMOD-A109
2. Introduction
Drying Oven LMOD-A109 features 70 L capacity, 50 to 300°C temperature range, and ±1°C temperature fluctuation. Equipped with an LCD display, PID temperature controller, and corrosion-resistant powder-coated steel housing. Incorporated with double-layer tempered glass window and high-quality silicone door seal for optimal insulation. It is equipped with stainless steel inner chamber, adjustable shelves, and uniform hot air circulation for consistent performance. Our Oven is suitable for drying, sterilization, and thermal processing in laboratories and industrial setups.
3. Features
Digital Timer Display Semicircle Chamber Corners Over Temperature Alarm Automatic Operation Alarm
4. Specifications
Model No. Capacity Temperature Range Temperature Resolution Temperature Fluctuation Timer Power Consumption Power Supply Working Dimensions Dimensions Packaging Dimensions Net Weight Gross Weight
LMOD-A109
70 L 50 to 300°C 0.1°C ±1°C 0 to 9999min 1000 W 110V 60Hz / 220V 50Hz 450 × 350 × 450 mm 620 × 710 × 620 mm 720 × 750 × 740 mm 48 Kg 62 Kg
5. Applications
Drying Oven LMOD-A109 is employed for drying, heating, and sterilizing samples in labs and industrial setups. It is ideal for moisture removal, thermal processing, and material testing in pharmaceutical and electronic industries.
3
Drying Oven LMOD-A109 6. Structure Introduction
The instrument boasts a durable exterior shell made from fine steel plate, while the interior working chamber is constructed of stainless steel or coated with hightemperature resistant silver lacquer for optimal thermal performance. Each chamber contains two to four adjustable shelves for versatility. For insulation, ultrafine glass wool is utilized, ensuring energy efficiency, while a double-layer glass observation box provides visibility without significant heat loss. A high-temperature resistant silicone rubber gasket or asbestos cord secures the seal between the working chamber and the observation box door. Control functions are conveniently located at the front, including a power switch and an intuitive temperature controller. The heating system features a fan, an electric heater, and a duct system designed for even heat distribution. Upon activation, the fan circulates heated air throughout the chamber, ensuring a consistent temperature. The microcomputer-controlled temperature system offers precise regulation with progressive heating to prevent overshoot. It includes self-regulation, accuracy in temperature settings, and a protection device with an alert function for optimal operation.
4
Drying Oven LMOD-A109 7. Operations
1) After moving the drying materials into the working chamber and shutting the box door, plug in the power source.
2) After setting the temperature and adjusting the temperature controller, the heat indicator illuminates, indicating that the instrument has begun to heat up. The specific procedure is as follows: After setting the power switch to “ON” for around 7 seconds, the temperature controller’s upper section shows the box’s actual temperature, while the lower section is used to set the temperature. Press , the first line displays SP. press or , which can make the second line displays your required temperature; press again, the first line displays ST (press or , which make the second line displays your required time. when ST is 0, the instrument cancels timing function; when ST is not 0, the instrument has timing function). Press once again, return to the standard model, and then the temperature controller finishes setting, the instrument can work. Typically, the temperature controller will reach a constant temperature after 90 minutes of heating the instrument.
3) The working chamber can quickly reach a stable temperature state by setting it a second time when your desired working temperature is lower. This will lessen or even eliminate the occurrence of temperature overshoot.
4) Depending on the needs of the various objects, select a different drying time. 5) Select “OFF” on the power switch once the drying process is complete, but do not
open the door to take anything out right away. To avoid getting burned, you can open the box’s door to reduce the temperature.
5
Drying Oven LMOD-A109
8. Troubleshooting
Phenomena
No electricity
No warming up in the box
There is a magnitude error between the setting temperature and the actual
temperature in the box Over-temperature Alarm abnormal
Reason Not connecting the power supply well or wire breaks
The fuse is broken The set temperature is too low The heater is not functioning
correctly The temperature controller is
abnormal The fan is not working The temperature sensor is
abnormal
The temperature controller is not properly adjusted
The set temperature is low The temperature controller is
abnormal
Treatment Check and reconnect the
power supply wire. Replace the fuse.
Adjust the set temperature
Replace the heater
Replace the temperature controller
Replace the fan Replace the temperature
sensor
Adjust the temperature controller
Adjust the set temperature Replace the temperature
controller
6
Drying Oven LMOD-A109 9. Circuit Diagram
Labmate Scientific Inc Email: info@labmate.com | Website: www.labmate.com
7
Documents / Resources
![]() |
Labmate LMOD-A109 Drying Oven [pdf] Instruction Manual LMOD-A109 Drying Oven, LMOD-A109, Drying Oven, Oven |