kramer-logo

kramer EXT3-U-R USB Receiver

kramer-EXT3-U-R-USB-Receiver-product

Product Information

Specifications:

  • Model: EXT3-U-R
  • USB Receiver: 1
  • Bracket set: 1
  • Rubber feet: 4

Product Usage Instructions

Step 1: Check what’s in the box
Ensure the following items are included:

  • EXT3-U-R USB Receiver
  • Bracket set
  • 4 Rubber feet
  • Quick start guide

Step 2: Get to know your EXT3-U-R

Features

  1. LINK LED: Flashes blue when a link is established.
  2. AUDIO OUT 3.5mm Mini Jack: Connect to an unbalanced stereo audio acceptor.
  3. USB 2 Type A Ports (1 to 4): Connect to USB devices. Connect the receiver directly to the power adapter for USB device charging.
  4. ON LED: Lights green when locally powered by the adapter, orange when powered by PoC.
  5. LINK IN RJ-45 Connector: Connect to the LINK OUT port on the EXT3-U-T.
  6. PROG (Tx, Rx) 5-pin Terminal Block Connector: Connect for firmware upgrade.
  7. RS-232 (Rx, Tx) (with common G pin): Connect for serial extension (9600 baud rate).
  8. 12V DC Power Connector: Connect to the power adapter.

Step 3: Mount EXT3-U-R
Install EXT3-U-R using one of the recommended methods provided in the manual.

Step 4: Connect inputs and outputs
Connect your devices to EXT3-U-R following the instructions provided. Always power OFF devices before connecting them.

Wiring the RJ-45 Connectors:
This section defines the TP pinout using a straight pin-to-pin cable with RJ-45 connectors. Ensure proper wiring as per the provided diagram.

Step 5: Connect power
The EXT3-U-R is powered via PoC. Follow safety instructions for power connection.

FAQ

  • Q: How do I update firmware on EXT3-U-R?
    A: To update firmware, connect the PROG (Tx, Rx) terminal block connector for firmware upgrade as detailed in the manual.
  • Q: Can I use third-party cables with EXT3-U-R?
    A: It is recommended to use Kramer cables available at www.kramerav.com/product/EXT3-U-R to avoid any potential damage. Third-party cables may not be compatible.
  • Q: What baud rate is supported for RS-232 communication?
    A: Only 9600 baud rate is supported for RS-232 communication with EXT3-U-R.

EXT3-U-R Quick Start Guide
This guide helps you install and use your EXT3-U-R for the first time.
Go to www.kramerav.com/downloads/EXT3-U-R to download the latest user manual and check if firmware upgrades are available.

kramer-EXT3-U-R-USB-Receiver- (1)

Step 1: Check what’s in the box

  • EXT3-U-R USB Receiver
  • 1 Bracket set
  • 4 Rubber feet
  • 1 Quick start guide

Step 2: Get to know your EXT3-U-R

EXT3-U-R kramer-EXT3-U-R-USB-Receiver- (2)

# Feature Function
1 LINK LED Flashes blue when a link is established.
2 AUDIO OUT 3.5mm Mini Jack Connect to an unbalanced stereo audio acceptor.
3 USB 2 Type A Ports (1 to 4)
  • Connect to USB devices.
  • Connect the receiver directly to the power adapter in order to charge USB devices.
4 ON LED Lights green when locally powered by the power adapter. Lights orange when powered by PoC.
5 LINK IN RJ-45 Connector Connect to the LINK OUT port on the EXT3-U-T.
6 PROG (Tx, Rx) 5-pin Terminal Block Connector (with common G pin) Connect for firmware upgrade.
7 RS-232 (Rx, Tx) Connect for serial extension (9600 baud rate).
8 12V DC Power Connector Connect to the power adapter.

Step 3: Mount EXT3-U-R

Install EXT3-U-R using one of the following methods:

kramer-EXT3-U-R-USB-Receiver- (3)

  • Ensure that the environment (e.g., maximum ambient temperature & air flow) is compatible for the device.
  • Avoid uneven mechanical loading.
  • Appropriate consideration of equipment nameplate ratings should be used for avoiding overloading of the circuits.
  • Reliable earthing of rack-mounted equipment should be maintained.
  • Maximum mounting height for the device is 2 meters.

Step 4: Connect inputs and outputs

In this example EXT3-U-R is connected to the Kramer SWT3-41-U-T transmitter.
Always switch OFF the power on each device before connecting it to your EXT3-U-R.

  • Devices that are connected to the EXT3-U-R USB ports are powered/charged while connected.
  • Only 9600 baud rate is supported for RS-232 communication for EXT3-U-R.

kramer-EXT3-U-R-USB-Receiver- (4)

Wiring the RJ-45 Connectors
This section defines the TP pinout, using a straight pin-to-pin cable with RJ-45 connectors.

Wiring the RJ-45 Connectors
This section defines the TP pinout, using a straight pin-to-pin cable with RJ-45 connectors. EIA /TIA 568B kramer-EXT3-U-R-USB-Receiver- (5)
PIN Wire Color
1 Orange / White
2 Orange
3 Green / White
4 Blue
It is recommended that the cable ground shielding be connected/soldered to the connector shield. 5 Blue / White
6 Green
7 Brown / White
8 Brown

To achieve specified extension distances, use the recommended Kramer cables available at www.kramerav.com/product/EXT3-U-R. Using third-party cables may cause damage!

Step 5: Connect power

EXT3-U-R is powered via POC.

Safety Instructions (See www.kramerav.com for updated safety information)

Caution

  • For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual.
  • There are no operator serviceable parts inside the unit.

Warning:

  • Use only the power cord that is supplied with the unit.
  • Disconnect the power and unplug the unit from the wall before installing.

kramer-EXT3-U-R-USB-Receiver- (6)