B100-A Precision Soldering Tool

Specifications:

  • Model: B100-A
  • Includes: 2 Grip Fitters, 1 Manual (Ref. 0033098)
  • Additional Items (Not Included): Cable USB-A to USB-C, ESD Safe
    Connection accessories

Product Usage Instructions:

Important Safety Guidelines:

Please read the manual thoroughly before using the product. Note
that the tool remains operational even when the display is off as
long as the batteries are charged. The tool can be manually
switched off and on by tapping the power button on the display.

Features:

The product includes 4 grips and supports C210 Cartridges. It
features a handle, status lightband, and compatibility with various
cartridges like Conical, Chisel, and Conical Bent Bevel.

Inserting C210 Cartridges:

Push the cartridges inside the handle until the reference mark
aligns with the handle’s edge. The cartridge holder with 4 slots
can store different cartridges for quick access.

Tool Charging:

Place the tool in the charging holder to charge it. A beep will
indicate when the tool is correctly placed for charging. Adjust the
volume using the left button on the display.

Cartridge Exchanger:

The exchanger is suitable for C115 and C210 cartridges. It
allows safe insertion and changing of cartridges without switching
off the tool. Cartridges are held securely in place by retention
clamps.

Cartridge Insertion:

To insert a cartridge, gently press the tip against the holes on
the sides of the cartridge exchanger to ensure proper insertion.
Cartridges must be inserted up to the mark for correct connection
and functioning.

FAQ:

Q: How do I know if the tool is charging correctly?

A: When you place the tool in the charging holder, a beep will
sound to indicate that it is properly placed and charging.

Q: Can I use cartridges other than C210 with this product?

A: The product is compatible with C115 and C210 cartridges.
Ensure to use only these specified cartridges for optimal
performance.

“`

Product website
INSTRUCTION MANUAL
B·100
Light Handle for B·IRON

This manual corresponds to the following reference: B100-A
Packing List
The following items are included:

Light Handle for B·IRON ………………. 1 unit

Grip* for B·IRON Handles ……… 1 unit *Available as B1510 (ref. 0031510), which comes with 4 grips.

Grip Fitters ……………. 2 units

Sealing Plug* for B·100 & B·500 Handles ………… 1 unit *Available as ref. OB4000, which comes with 10 sealing plugs.

Manual ………………………… 1 unit Ref. 0033098

Important
Please read this manual and its safety guidelines thoroughly before using the product.

Note: Even if the display is turned off, the tool remains operational as long as the batteries are charged, even when the cartridge is removed. The tool can be manually switched off and on by tapping the tool power button on the display (see page 9).
The tool turns off automatically only under the following conditions: – The tool is out of the charging holder (without safety cap on) and remains completely
still for 5 minutes (see page 8). – The tool has the safety cap on and remains completely still for 60 minutes (see page 9). – The tool is in the charging holder and the charging base is disconnected from the mains.

2

Connection with B·IRON Station
PDS Portable Display 7″
for B·IRON *

Bluetooth Connection

B·100 Light Handle for
B·IRON

Cable USB-A to USB-C * Ref. 0032705

C210 Cartridge
Range

USB Connector

Power Socket

B1596 Safety Cap for B·IRON Handles

ESD Safe Connection
Note: All B·IRON components comply with CE standards, but the tool by itself is not grounded. Therefore, to comply with ESD regulations, the user of the B·IRON tool must be ESD-compliantly grounded.
JBC offers ESD tablemats, earthing cables, plugs and wristbands. More information on www.jbctools.com.

* Not included, sold separately.
3

Features
B·100 performs up to 100 medium-sized SMD soldering joints per charge and is the ideal tool for for R&D departments and individual soldering jobs. Its technical performance has enabled a comfortable and lightweight design. Note: To charge the tool a B·IRON station is needed.
B1510 Grips for B·IRON Handles
(Ref. includes 4 grips) C210* Cartridge Range

B1596 Safety Cap for B·IRON Handles

Handle

Status Lightband

Compatible Cartridges*
B·100 Handle works with C210 Cartridges. Find the model that best suits your soldering needs on www.jbctools.com.

Conical

Chisel

Conical Bent Bevel

Inserting C210 Cartridges
Push the cartridges inside the handle until the reference mark is aligned with the edge of the handle.

C210 Cartridge Holder
The cartridge holder (4x slots) is used to store cartridges. It allows having different cartridges quickly at hand and it works with C210 Cartridges.
Cartridge Holder Slots

Reference Mark

Reference Mark

* Not included, sold separately.
4

SCtaarttiroidngSeeItnUseprt(cioontninuaationnd) Tool Charging

Cartridge Exchanger

Retention Clamps

1

The exchanger is suitable for C115 and C210 cartridges.

C115 Cartridges

The holding area of C115 Cartridges is delimited by the two

rings at the cartridge shaft (x). x

C115 Cartridge

The cartridge exchanger allows inserting / changing cartridges safely without switching the tool off. Cartridges are held in place thanks to the retention clamps (1).

C210 Cartridges The holding area of C210 Cartridges goes from the collar of the tip until the cartridge begins to widen (x).

C210

x

Cartridge

Cartridge CInhsaenrtginingg

Cartridge Fixing

Tool Charging

1

2

3

2 1

4

Cartridge Exchanger

Place tthhee totoool lwoitvherthae cartridge aonvderprtehses tchaertoridolgdeowexncthoainnsgeertr tshloetscaarntrdidpgrees(1s).dToowrnel(e1a) suentihl eit tcolioclkws.itThotrheemcoavretritdhgeecianrsterirdtegde fproumll ththeeheaxntdralectoour,t li(f2t).the tool uTopwinasredrt(2a). cartridge, carry out the same steps as before in reverse order.

Gently press the tip against the holes on the sides of the cartridge exchanger (3) to ensure that the cartridge is appropriately inserted.

Note: Cartridges must be inserted up to the mark for a proper connection and functioning.

Mark

Place the tool in the charging holder (4) to charge it. A beep will sound when the tool is properly placed and charging. The volume can be adjusted using the left button on the display.
Important: Charge the tool completely before using it for the first time. A full charge takes: -30 min for B·100 -60 min for B·500 -30 min for B·NANO -45 min for B·TWEEZERS

5

Tool CSeolnenceticotnion

Make sure that the charging base is connected to
the mains. JBC
Note: Tools supplied with a station are already connected to the station.

Device List 9
6 7

Scanning another tool (this process can take a while):

11

Place the tool in the charging holder to activate it.

The status light band color indicates the charge level

(see table below).

If the scanning process does not run automatically,

tap “scan” (6) on the display while the tool remains

in the charging holder. When the tool is shown in

the device list on the display, select it (11) and tap

“connect” (7). Now the tool is ready for soldering.

8 10

Tool search function: When in doubt of which tool corresponds to the tool’s name, use the tool search function. Tap on the magnifying glass symbol (8) next to the tool’s name. The light band on the corresponding tool blinks in blue for five seconds to identify it.

Working with two tools (works also for charging bases with only one charging holder): It is possible to connect up to two tools at the same time. If a tool is already connected, first disconnect it from the device by selecting “Menu” (9) and tapping on “Disconnect”.

Place the second tool in the charging holder and scan it (6). The second tool is also shown in the device list on the display (10). To work with two tools, select one from the left-hand column (11) and the other one from the right-hand column (10). Then tap on “connect” (7).
Status Lightband

The status lightband on the tool indicates its status (see table on the right).
Safety Cap
Status Lightband Detail

Color
Green
Orange
Red
Green blinking Orange blinking
Red blinking
No color

Tool Status
More than 50% charged
Between 20% and 50% charged
Less than 20% charged
Charging (more than 50% charged)
Charging (between 20% and 50% charged)
Charging (less than 20% charged) Safety cap on the handle
and/or power off

Blue blinking

Locate Tool function activated

6

Operation

Thanks to the intelligent heat management, the cartridge tip recovers temperature extremely quickly. This allows reducing the tip temperature when the device is not in use, resulting in a longer tip lifespan. When the tool enters Sleep (1) or Hibernation (2) Modes, the tip temperature lowers automatically below the solder-melting-point temperature.

Temp.
Work temp.

Sleep temp.

Work

Room temp.
0

Tool Status

Tip Temperature

1
Sleep (selectable time)

Hibernation 2

Tool in charging holder Heating

Work Time

Tip Temperature

The tool can go into a number of statuses under different circumstances (see the diagram on the next page). Depending on the status, the cartridge tip reaches different temperatures:

Tool Status Sleep and charging Hibernation and charging

Tip Temperature
Cools down to the set Sleep temperature. Selectable between 70 °C and 150 °C.
Cools down to room temperature.

Working Resting without cap
Tool with cap on Hibernation

Heats up to the set work temperature.
Cools down to room temperature (after 5 min of being completely still).
Cools down to room temperature.
Cools down to room temperature.

Shut off

Remains at room temperature (tool is shut off).

Sleep and Charging

Sleep Mode can be is activated and the

taocotJilviasBtpeClda/cdeedacintivthaetecdh(a1r).gIef rit,

the tip cools down to sleep temperature and the

tool keeps charging.

Hibernation and Charging

If Sleep Mode is not activated and the tool is placed in the charger, it goes into Hibernation. The tip cools down to room temperature and the tool keeps charging.
JBC

MENU Return to Work

JBC

210

1
JBC#1

Tool ID
TTooooll11
2822
Hibernation delay
0100:30
Temperature units

ºC

ºF

Lock Parameters

Locked

Unlocked

Maximum Temperature
400ºC

Sleep mode Sleep temperature
150ºC

Tool Status Working Low battery Power OFF

Charging No cartridge

7

Tool Status (continuation)

Sleep OFF tool cap pldaocwendboetnween 5″…10″

HIBERNATION

& charging

2

8

mains

Sleep ON

AUTO disconnected tool in

SHUT-OFF

CHARGER

(mains connected)

after 5′

SLEEP
& charging

1

tool is picked up

tool is picked up

3
WORK

t(orecahcatirvgaetiron)

tool to charger

9

6

4

AUTO
SHUT-OFF

after 5′ HIBERNATION

tool laid

5

after 60′

7

HIBERNATION

Work
When the tool is taken out of the charger while in Sleep (1) or Hibernation (2) Modes, the cartridge tip heats up to the set work temperature and the tool is ready to use (3).
Hibernation
The tool goes into Hibernation Mode in two different cases: a) After working, when the tool is laid down (4) and is resting between 5 and 10 seconds (time is adjustable). b) After working, when placing the cap on the tool (5).
Note: Before the tool enters Hibernation Mode, it can be picked up to work with it and the cartridge tip heats up to work temperature.
Auto Shut-off
The tool shuts off automatically in three different cases: a) When the tool (without the tool cap) is laid down and remains completely still in Hibernation Mode for 5 minutes (6). b) When the tool (with the tool cap on) remains completely still in Hibernation Mode for 60 minutes (7). c) When the tool is in the charger and the charging base is disconnected from the mains (8).
8

Tool Status (continuation)
Tool Reactivation

JBC

Once the tool has automatically shut off, place it back in the charging holder (9) to reactivate it (see diagram on previous page).

Manual Tool Shut-Off
Besides the “automatic shut-off” feature, the tool can also be manually switched off by tapping the tool power button on the display. When it is switched off, the cartridge cools down to room temperature.
Note: To switch the tool back on, tap the same button on the display.

350ºC

Safety Cap

12 W

6 W

10 seconds/div

Tool

ON

0 W V1.2

Tool On/Off Button

Safe Tool Transportation
Thanks to the tool’s safety cap, B·IRON tools can be carried around safely, even with the cartridge inserted.
When the cap is placed onto the tool, it goes into Hibernation Mode immediately and the cartridge tip cools down to room temperature.
Note: The purpose of the cap is to allow safe transport, not storage.

Safety Cap Safety Cap

Handle

Safety Cap Holder
While the tool is in use, the safety cap can be stored on the cap holder located on the back of the charging base.
There is space for two caps.

Cap Holder

9

JBC Software
No installation or initial download are required for newly purchased JBC products. Both JBC display and tools come with its current software/firmware installed and updated, and are ready to use.
Note: App: If a third-party display (tablet or smartphone) is used, the B·IRON app must be downloaded from JBC’s web page and installed on the device. Firmware: The tool’s firmware is not automatically updated and the updates must be carried out manually by the user. To do so, follow the instructions on the next page.

App Versions
Make sure that the required app version is installed on the display (tablet or smartphone):
– Handles require app versions 1.6 or higher. – Tweezers require app versions 1.7 or higher.

App Installation
On JBC’s portable display (Android), the B·IRON app is already installed.
On the user’s smartphone or tablet (Android / iOS), go to the App Store/Play Store and search for “JBC B.IRON” on the search bar. Note: Internet connection is required to download the app.

Alternatively, scan these QR codes to access the B·IRON app page directly:

App UpdJaBteC
Display with Internet connection (Android / iOS) Update the app via Google Play (Android) or the App Store (iOS).

JBC

Display without Internet connection (Android) Download JBC’s installer program to another device with an Internet connection from JBC’s website: https://www.jbctools.com/jbcsoftware.html

Then copy the downloaded program to the internal storage of the display used with B·IRON. Access the internal storage of the display and run the downloaded program. Once the program is completed, the app will be updated to the latest version. Note: For JBC displays, swipe down to open the internal storage folder.

10

JBC

JBC

Downloading the Tool Firmware Update File
Display with Internet connection: Download the firmware update file to the display used with B·IRON from https://www.jbctools.com/ jbcsoftware.html. Go to the internal folder and unzip the downloaded file. Display without Internet connection: Download the firmware update file to another device with an Internet connection from JBC’s website: https://www.jbctools.com/jbcsoftware.html and unzip the downloaded file. Then do as described in the table.

PDS JBC’s display (android)

Other android devices

iOS devices

Copy the unzipped files on the device used with B·IRON:

Folder:
Internal shared storageAndroiddata es.infinitysource.jbc_ soldering.JBCBironfiles

Folder:
Internal shared storage Androiddatacom. jbctools.jbcbironfiles

Path:
Files > On my iPad > JBC B.iron

Executing the Tool Firmware Update File

Tool firmware be carried out

updates are by the user.

nJot BexeCcuted

automatically;

they

must

On the display you are using with B·IRON, and with the latest app version installed, access the B·IRON app:

Select he tool you want to update. Then in the main menu select “update”.
Note: At least one tool must be connected to see the expanded menu options.

JBC

Main menu with expanded menu options
MENU Work
450 ºC
Settings
Counters
350 ºC
Update
2L5o0cºCate Tool
Documents
150 ºC
Light Theme Dark Theme
50 ºC 80%
Disconnect
JB1C1

Executing the Tool Firmware Update File (continuation)

If the downloaded tool firmware update file contains a newer version than the one already installed, the current and new version are displayed (1). Tap “Update” to start the update (2).

The update process takes about 10 minutes.

1

Note: If the firmware update is interrupted, the app automatically recognizes this and starts a new update process. “Device needs recovery” appears on the top left corner of the display. Press the “Update” button (2) in the pop-up window to continue the firmware update.

The B·IRON status light continuously changes its color during the update process.
Once the update is completed, “Tool updated” (3) will be displayed.

2 3

If “No new version available” is displayed (4), no update is possible or required.
4
Replacement Parts for B·100 Handles

B1510 Soft Foam Grips for B·IRON
Handles Reference comes with 4 grips

B1596 Safety Cap for B·IRON
Handles Reference comes with 1 cap

OB4000 Sealing Plugs for B·100 &
B·500 Handles Reference comes with
10 sealing plugs

12

Maintenance – B·IRON Handles

Replacing Soft Foam Grips – B1510 includes 4 grips

Inserting Fitters

Assembling Grips

Removing Fitters

Fitter

New Grip

Handle

Insert the fitters into the new Push the grip with the fitters

grip.

onto the handle.

Hold this way so the fitters can slide
To remove the fitters, hold the grip and pull the fitters out. Use pliers if necessary.

Sealing Plugs

The sealing plug prevents undesirable flux vapors or particles from entering the handle and its usage is highly recommended. If the sealing plug is not used, this can lead to incorrect cartridge contact and may render the tool unusable.

Note: Check the condition of the plug periodically and replace it as soon as wear or cracking is detected.
Before replacing the sealing plug, disconnect the handle from the station and make sure the device has cooled down.

Handle

Sealing Plug Ref.

B·NANO

OB5000*

B·100 and B·500 OB4000*

* each ref. comes with 10 sealing plugs

Replacing Sealing Plug for B·100 & B·500 Handles – OB4000 comes with 10 sealing plugs

Sealing Plug

Chamfered Side

View: inside

Handle

Edge inside the groove

Introduce a small shaft or screwdriver, not deeper than 8 mm, lift and pull the sealing plug. Never use a cartridge to do this operation.

Push the sealing plug inside the handle. Note: The chamfered side of the sealing plug has to be positioned towards the handle.

Make sure the sealing plug is placed correctly. The edge of the sealing plug must rest in the groove of the tool bushing.

13

Maintenance – Station and Tools

Before carrying out maintenance, always extract the cartridge from the tool and disconnect the charging base from the mains. Allow the equipment to cool down.

– Use a damp cloth to clean the casing and the tool. Alcohol can only be used to clean the metal parts.

– Periodically check that the metal parts of the tool and charging holder are clean so that the charging works properly.

– Keep the tip surface clean and tinned prior to storage in order to avoid tip oxidation. Rusty and dirty surfaces reduce heat transfer to the solder joint.
– Do not use liquids such as alcohol, thinner or benzene to clean the portable display.
– Repairs should only be performed by a JBC authorized technical service.

Clean the contact surfaces regularly to ensure that the Clean the ctooonltgaectts charged surfaces recgourrleacrltylyt.o ensure that the tool gets charged correctly

Safety – Battery
It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion.
– Caution: This product contains lithium-ion batteries. Mishandling or improper use may result in fire, explosion, or personal injury.
– Always use the provided charger. Do not use damaged chargers or batteries. – Never attempt to disassemble or modify the batteries or the product. Doing so may lead to electric
shock, fire, or damage to the product. – In the event of damage, leakage, or overheating of the batteries, discontinue use immediately and
contact customer support or JBC technical service facility. – Dispose of devices with batteries inside, responsibly according to regulations. They must be disposed
of in accordance with local regulations so that they can be recycled. – Do not throw devices with batteries into household waste and do not dispose of them in fire or water.
14

Safety
It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion.
– Do not use the units for any purpose other than soldering or rework. Incorrect use may cause a fire. – The power cord must be plugged into approved bases. When unplugging it, hold the plug, not the wire. – Do not attempt to dismantle or open the housing of the tool as it may cause damage. – Do not work on electrically live parts. – The tool should be placed in the charging holder when not in use in order to charge the batteries. – The soldering tip, the metal part of the tool and the charging holder may still be hot even when the
station is turned off. – Do not leave the tool unattended when it is on. – Avoid flux coming into contact with skin or eyes to prevent irritation. – Be careful with the fumes produced when soldering. – Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working
to avoid personal harm. – Utmost care must be taken with liquid tin waste, which can cause burns. – This appliance can be used by children over the age of eight and also persons with reduced physical,
sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning the use of the appliance and understand the hazards involved. Children must not play with the appliance. – Maintenance must not be carried out by children unless supervised. – Do not expose the portable display to high temperatures, humidity or dust. Avoid direct sunlight. – Do not drop the portable display or the tool, as it may cause damage or malfunction. – Do not disconnect your device when it is in file transfer mode. – Do not use the portable display in places where wireless communications are restricted.
15

Specifications

B·100 Light Handle for B·IRON Ref.: B100-A
– Peak Power (Tool): – Battery: – Charge Time: – Selectable Temperature: – Idle Temp. Stability (still air): – Temp. Accuracy: – Connections: – Ambient Operating Temp: – Tool Weight (without safety cap):

24 W Li-Ion 7.4 V / 180 mAh 30 minutes 100 – 450 °C / 210 – 840 °F ±1.5 °C / ±3 °F ±3% (Using reference cartridge) Bluetooth Low Energy (BLE) 10 – 50 °C / 50 – 122 °F 35 g / 0.077 lb

– Total Net Weight: – Total Package Dimensions/Weight:
(L x W x H)

75 g / 0.165 lb 220 x 75 x 30 mm / 120 g 8.66 x 2.95 x 1.18 in / 0.265 lb

Complies with CE standards. ESD safe (to comply with ESD requirements, see page 4).

Warranty JBC’s 2 year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labor. Warranty does not cover product wear or misuse. In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased.
This product should not be thrown in the garbage. In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must be collected and returned to an authorized recycling facility.

0033098-200625

Documents / Resources

JBC B100-A Precision Soldering Tool [pdf] Instruction Manual
B100-A, B0643, 0033098, B100-A Precision Soldering Tool, B100-A, Precision Soldering Tool, Soldering Tool

References

Leave a comment