itsensor LM3485 Pyrano Meter PYRA-485 User Manual
itsensor LM3485 Pyrano Meter PYRA-485

GENERAL DESCRIPTION

PYR1-485 and PYR2-485 are ISO 9060:2018 CLASS B (First Class) and CLASS C (Second Class) pyranometers respectively, with RS485 bus interface with the well known industry standard protocol Modbus RTU.

FEATURES

PYR1-485 PYR2-485
Measurements:
spectral range
input irradiance range
300 ÷ 2900nm
0 ÷ 1600 W/m2
Response time < 20 sec < 25 sec
Temperature response < ± 2 % (-10 to +40°C) < ± 5 % (-10 to +40°C)
Zero offse
Thermal radiation (at 200 W/m2 )
Temperature change (5 k/h)
<14Wm2 <20Wm2
Resolution
Smallest detectable change
Outputs
serial
RS485, standard Modbus RTU protocol 1W/m
Output resolution: ± 4 W/m² ± 8 W/m²
Output precision Tilt response (0 ÷ 90°)
Temp. Response ( ∆t = 50K)
< ± 2%
< 4%
< ± 4%
< 8%
Working temperature: -40 ÷ +80 °
Supply C 9 ÷ 30 Vdc protected against short circuit
Encapsulation:                               Quartz [k5]
Special glass transparent to Double glass dome
0,3 ÷ 3,0 μm
Single glass dom 0,3 ÷ 3,0 μm
Case Anodized aluminum
Connectors standard M8 4 pin female
Dimensions Φ 162 x h 104 mm

PIECE’S LIST

  • Pyranometer with sun screen
  • M8 4pin male connector
  • Instruction sheet
  • Calibration Report

CALIBRATION

Date:.……………………………………….
Operator: ……………………………….
S/N:………………………………………….
Modbus Node: ………………………

DIMENSIONS

DIMENSIONS diagram
DIMENSIONS diagram

CONNECTIONS

See the table below. Once connected the irradiance values comes out instantly (Fig.1 has correspondence with the rear side where you have to connect wires)

# pin SolSol Cable Color Description

1

Green RS485+/B, communication bus non inverting bus signal

2

Red

Power supply 12 ÷ 30Vdc

3

Green/White

RS485-/A, communication bus inverting bus signal

4 Black

Power supply / 0 Vdc

CONNECTIONS diagram
Fig.1 Front and back view of male connector

Data is accessible through Modbus’s functions by 16 bits units called “registers”. In the current implementation of PYRA-485 these registers are available:

Register hex Register dec Description Access NV save
0x0101 257 Current irradiance level [W/m2] R
0x8802 34818 Current body temperature [°C], 2-complent value, fixed point 14.2 format (14 bits integer, 2 bits fractional) R
0x0103 259 Status, bit coded R
Bit Description
0 Factory calibration/configuration 1 = OK; 0 = need recalibration
1 Not volatile parameters

1 = OK; 0 = default loaded, need to be changed/saved

2 Not used
3 Not used
4 Not used
5 Watchdog

1 = reset by watchdog timeout occurred; 0 = normal operation

all undefined bits read as 0
0x8001 32769 Serial number, least significant word R
0x8002 32770 Serial number, most significant word R
0x8003 32771 Firmware main version, hexadecimal R
0x8004 32772 Firmware minor version, hexadecimal R
0x8005 37773 Node address, range 1 ¸ 247, decimal, default 1 R/W Y
0x8006 32774 Bitrate, coded, range 0 ¸ 4, decimal, default 1

0 – 9600 bps
1 – 19200 bps
2 – 38400 bps
3 – 57600 bps
4 – 115200 bps

R/W Y
0x8007 32775 Serial configuration, coded, range 0 ¸ 3, decimal, default 0

0  – 8N1 (8 bit / no parity / 1 stop bit)
1  – 8E1 (8 bit / even parity / 1 stop bit) 2 – 8O1 (8 bit / odd parity / 1 stop bit) 3 – 8N2 (8 bit / no parity / 2 stop bit)

R/W Y
0x8008 32776 Serial reply delay [ms], range 0 ¸ 100, decimal, default 1 R/W

Y

0x8101 33025 Not volatile params save command, write 1 to execute (then wait 1 s before to send next message) W

0x8102 33026 Software reset command, write 1 to execute (then wait 6 s before to send next message) W

CALIBRATION

It is recommended to send to factory for verifying calibration after 2 years of outdoor work

MAINTENANCE

Reading is reduced if the dome is not clean.

  1.  Keep the dome clean using water or alcohol.
  2. Keep instrument levelled.
  3. Recalibrate every 2 years.

INSTALLATION

It is recommended to install the product at a minimum height of 180cm above the ground.
INSTALLATION diagram

There are the following fixing types:

  • With M5 screw on flat bases;
  • Bracket on pole;
  • Inclinable bracket in degrees

fixing diagrqam
M5 screw on flat bases *screw’s thread must be 0,4cm + distance between the pyranometer and the base. (approx. 1,5 – 1,8 cm long.)

USER INFORMATION

Read this document carefully before installation.
Warranty is 2 years from date of invoice, subject to correct installation and use. Soluzione Solare accepts no liability for any loss or damage arising from incorrect use of the product. This device conforms to the EU ‘CE’ guideline 89/336/EEC73/23/EEC. Unauthorised modifications may void the warranty and CE validity. Visit our website for the latest product support information.

CONTACTS

For further information, contact us:
assistenza@itsensor.it
+39 0425 1810834

ITSENSOR Srl– Viale Porta Adige 45 – Torre Uffici Censer – 45100 Rovigo (RO) – ITALY
www.itsensor.it
+39 0425 1810834
info@itsensor.it

 

Documents / Resources

itsensor LM3485 Pyrano Meter PYRA-485 [pdf] User Manual
LM3485, Pyrano Meter PYRA-485, Meter PYRA-485, Pyrano Meter, PYRA-485, LM3485