INMBSMEB0200000 M-BUS to Modbus TCP and RTU Server Gateway

Product Information

Specifications

  • Item number: INMBSMEB0200000
  • Supports: Modbus RTU and Modbus TCP protocols
  • Power supply: Not included
  • Connectors: Power supply, KNX, MBUS, Ethernet, Console port
    USB, USB storage
  • LED Indicators: Gateway and communication status
  • Battery Description: Manganese Dioxide Lithium button
    battery
  • Certifications: ETIM Classification EC001604, WEEE Category IT
    and telecommunications equipment

Product Usage Instructions

Installation Conditions

Ensure proper mounting on DIN rail (bracket included) or wall
mount using provided materials.

Content of Delivery

Includes the gateway device. Power supply not included.

Identification and Status

  • Product ID: INMBSMEB0200000
  • Country of Origin: Spain
  • HS Code: 8517620000
  • Export Control Classification Number (ECCN): EAR99

Physical Features

The device features various connectors for input/output, LED
indicators for status, DIP & Rotary switches for configuration,
and a manganese dioxide lithium button battery.

FAQ (Frequently Asked Questions)

Q: Does the gateway support both Modbus RTU and Modbus TCP
protocols?

A: Yes, the gateway supports both Modbus RTU and Modbus TCP
protocols.

Q: Is the power supply included in the delivery?

A: No, the power supply is not included in the delivery
package.

Q: What is the warranty period for the product?

A: The product comes with a warranty of 3 years.

“`

M-BUS to Modbus TCP & RTU Server Gateway

Item number: INMBSMEB0200000 Integrate any M-Bus device with a Modbus BMS or any Modbus TCP or Modbus RTU controller. This integra on aims to make M-Bus devices, their registers, and resources accessible from a Modbus-based control system or device as if they were a part of the Modbus system and vice versa.

M-BUS to Modbus TCP & RTU – 20 devices

Features and benefits
Up to six concurrent Modbus TCP clients supported The gateway supports up to six simultaneous Modbus TCP clients. Easy integra on with Intesis MAPS The integra on process is quickly and easily managed using the Intesis MAPS configura on tool. Configura on tool and gateway automa c updates Both the Intesis MAPS configura on tool and the gateway’s firmware can receive automa c updates. Embedded M-Bus level converter An M-Bus level converter is embedded in the gateway, so no external one is required.

Support for both Modbus RTU and Modbus TCP The gateway supports both Modbus RTU and Modbus TCP protocols.
Commissioning-friendly approach with Intesis MAPS Templates can be imported and reused as o en as needed, significantly reducing commissioning me.
Automa c meter detec on and register discovery A scan func on is available for automa c iden fica on of M-Bus devices and registers discovery.

Page 1 of 4

M-BUS to Modbus TCP & RTU Server Gateway

General
Net Width (mm) Net Height (mm) Net Depth (mm) Net Weight (g) Packed Width (mm) Packed Height (mm) Packed Depth (mm) Packed Weight (g) Opera ng Temperature °C Min Opera ng Temperature °C Max Storage Temperature °C Min Storage Temperature °C Max Power Consump on (W) Input Voltage (V) Power Connector Configura on Capacity
Installa on Condi ons
Content of Delivery

88 90 58 159 127 86 140 184 0 60 -30 60 13 24VDC +/-10%. 3-pole Intesis MAPS Up to 20 meters. This gateway is designed to be mounted inside an enclosure. If the unit is mounted outside an enclosure, precau ons should always be taken to prevent electrosta c discharge to the unit. When working inside an enclosure (e.g., making adjustments, se ng switches, etc.), typical an -sta c precau ons should always be followed before touching the unit. Intesis Gateway, Installa on Manual, USB Configura on cable.

Page 2 of 4

M-BUS to Modbus TCP & RTU Server Gateway

General
Not Included (in delivery) Moun ng Housing Materials Warranty (years) Packaging Material

Power supply not included. DIN rail mount (bracket included), Wall mount Plas c 3 years Cardboard

Identification and Status

Product ID

INMBSMEB0200000

Country of Origin

Spain

HS Code

8517620000

Export Control Classifica on Number (ECCN)

EAR99

Physical Features

Connectors / Input / Output

Power supply, KNX, MBUS, Ethernet, Console port USB, USB storage.

LED Indicators

Gateway and communica on status.

DIP & Rotary Switches

EIA-485 serial port configura on.

Ba ery Descrip on

Manganese Dioxide Lithium bu on ba ery.

Certifications and Standards

ETIM Classifica on

EC001604

WEEE Category

IT and telecommunica ons equipment

Page 3 of 4

M-BUS to Modbus TCP & RTU Server Gateway Use Case
Integra on example.
Page 4 of 4

Documents / Resources

Intesis INMBSMEB0200000 M-BUS to Modbus TCP and RTU Server Gateway [pdf] Owner's Manual
INMBSMEB0200000, INMBSMEB0200000 M-BUS to Modbus TCP and RTU Server Gateway, M-BUS to Modbus TCP and RTU Server Gateway, Modbus TCP and RTU Server Gateway, TCP and RTU Server Gateway, Server Gateway, Gateway

References

Leave a comment