HT-A9,HT-A10 Thermal Imaging Camera
Product Information
Specifications
- Brand: Dongguan Xintai Instrument Co.,Ltd.
- Model: HT-A9, HT-A10
- Version: User Manual Version 1.0 (November 15, 2023)
- Country of Origin: China
Product Description
The Thermal Imaging Camera by Dongguan Xintai Instrument
Co.,Ltd. is designed to provide infrared thermal imaging
capabilities for various applications.
Performance Index
The performance index includes features like image overlapping,
color palette selection, emissivity setting, and various menu
options for customization.
Product Usage Instructions
1. Preliminary Acquaintance
Before using the thermal imaging camera, read the user manual
carefully to understand its features and functions.
2. Cleaning and Maintenance
Regularly clean the lens of the camera using a soft cloth to
ensure clear image capture. Avoid harsh chemicals for cleaning.
3. Charging the Battery
Charge the battery fully before initial use. Follow the
instructions provided in the manual for proper charging
procedures.
4. Initial Operation
Power on the thermal imaging camera and familiarize yourself
with the menu options and key functions as described in the
manual.
Explore the different sub-menus such as image overlapping, color
palette selection, emissivity settings, and other customization
options for optimal usage.
6. Software Operation
Refer to the Thermal Imaging Image Analysis Software Operation
Guide for detailed instructions on analyzing captured images and
videos.
FAQ
Q: What should I do if I encounter smoke or a burnt smell while
using the thermal imaging camera?
A: Immediately stop using the device, power it off, and contact
the local distributors or agents of the company for assistance.
Q: How should I clean the lens of the thermal imaging
camera?
A: Use a soft cloth to gently clean the lens. Avoid using harsh
chemicals that may damage the lens.
Thermal Imaging Camera Instruction Manual
Dongguan Xintai Instrument Co.,Ltd.
Add: Building16, No.3, Yongtai Road, TangxiaTown, Dongguan City,Guangdong,China Postal Code: 523710 Tel: +86-769-82612006 Fax: +86-769-82612005 Website: www.hti-meter.com www.hytechcn.com.cn www.xintest.en.alibaba.com
User Manual Version 1.0. November 152023.
HT-A9
HT-A10
Contents
Preface Safety Instruction Preliminary Acquaintance with Infrared Thermal Imager Overview Cleaning of the Products Lens Maintenance Charging of the Battery and Description Performance Index Product Description
1. Instruction to Structure 2. Display Description 3. Key Description Initial Operation Introduction to the Menu 1.”Image Overlapping” Submenu
1.1Description of Image Overlapping 1.2. Application of Image Overlapping 2. Introduction to “Image” Sub-menu 2.1. View Image 2.2. Delete Images 3. Introduction to “Video” Submenu 3.1. View Video
1
3.2. Delete Video
19
1
4. Introduction to “Color Palette” Sub-menu
20
5
4.1. Color Palette Description
20
6
4.2. Application of Color Palette
21
7
5. Introduction to “Emissivity” Sub-menu
21
7
5.1. Emissivity Description
21
8
5.2. Emissivity Setting
22
9
5.3. The Emissivity Value of Common Materials
24
11
6. Introduction to “Setting” Sub-menu
25
11
6.1. Auto Shutdown Setting
26
13
6.2. Intensity Settings
26
14
6.3. Language Settings
26
14
6.4. Unit Setting
26
17
6.5. Tempertature Range Setting
26
17
6.6. Time Format Setting
27
17
6.7. Time Setting
27
17
6.8. Enable/Disable of the Highest and Lowest Temperature Cursor 28
18
6.9. Wireless WIFI on and off
29
18
Thermal Imaging Image Analysis Software Operation Guide
30
18
19
19
Preface
Respected users: How are you! Thank you for purchasing our instrument. In order to use it in a better manner, we remind you to read the instruction for use carefully before use and keep it properly so as to look up in the future use.
Safety Instruction
Please ensure that you have read and understood the safety precautions described in the following text before using the product so that you can operate it correctly. The safety precautions described in the following text guides you to operate the product and its accessories correctly and safely to avoid damage and loss to you,other people and the device.
Considerations
Please observe the following guide in order not to damage the product: Don’t assemble or dismantle the product without permission. The product is a type of super precise equipment. Don’t try to dismantle, assemble or remodel any part of the product. Repair of the product should be made by technical personnel designated by the company. Avoid damage to probe of the product. Note: don’t put the product close to strong heat source directly (such as electric iron). Otherwise, it may damage the probe of the product. Product hum. When the product works, there is light sound of clicking every several seconds. This is normal phenomenon that the lens captures images.
1
Warning
The warning describes the acts that may cause harm to users. Please observe the following operation in order to avoid electric shock or personal injury. If the product case is damaged, don’t use it continuously. Please contact the local distributors or agents of the company under such condition.
During the process of use, if the product is found with smoke,spark and the burnt smell, please stop using at once. In case of such condition, the product power supply should be powered off first.After the smoke and peculiar smell disappears completely, please contact the local distributors or agents of the company.
Don’t weld the battery without permission. Such operation may damage the battery and result in leakage and explosion of the battery.
Avoid that the battery is impacted (such as collusion and falling, etc). Such condition may damage the battery case or result in that the battery leaks or explode.
Please pull off the adapter on the power socket when charging is not made. The adapter may get overheated if it is connected with power supply for a long time. This may cause overheating, deformation and fire.
2
Please ensure that the plug of the adapter is inserted into the specified power socket. The adapter plug may be different due to the regions. Please make confirmation whether the specification of the adapter is consist with the specification of electric appliances in your region. Otherwise, this may cause overheating of the equipment, electric shock, fire, chemical leakage inside the battery, explosion and other serious consequences.
When the plug of the adapter or wire is damaged, stop using immediately. Don’t change the battery unless the plug of the charger is inserted into the socket completely.
Do not touch the electric wire with wet hands. It is possible to cause electric shock when touching the electric wire with wet hands. When pulling out the electric wire, hold the electric wire head rightly to pull out the wire. Don’t pull off the electric wire directly. Otherwise, the electric wire may be broken, causing electric shock and fire.
Forbid dip the product into water caught in rain. If the case contact with any liquid, please wipe it dry immediately. If water or other liquid enters the inside of the instrument, please power off the power supply at once. Continuous use may result in product damage.
Clean the dust on the adapter plug and the data line. When it is exposed to dusty and dump environment for a long time, the dirt surrounding the electric equipment will accumulate moisture. This may cause short circuit and fire.
3
Don’t use abradant, isopropanol or solvent to clean the enclosure of the device. Such operation may cause the product case to be damaged.
The product temperature may increase after a long time of charging. You may feel scorching heat when the hands touch the sensors.
Problem caused by water condensation. Don’t bring the instrument into low temperature environment from high tempera-ture environment in a short time or from low temperature environment to high temperature environment. This may result in that the inside of the instrument and appearance produce water condensation. In such condition, the instrument should be placed into portable box or plastic bag. Before use, make it restore to the environmental temperature and take it out to use. If the product has water condensation inside, please power it off immediately.Otherwise, the instrument may be damaged. Operation is not allowed unless the water condensation disappears.
Avoid that the product is impacted (such as collision and falling, etc). Such operation may cause the product to be damaged. Please avoid such operation.
Long-time storage and regular charging. The product should be placed at a cool and dry environment if it not used for a long time. If the product installed with battery is stored for a long time, charging should be made regularly. Otherwise, the battery will run out and the service life will be shortened.
4
Preliminary Acquaintance with Infrared Thermal Imager
For a long time, infrared thermal imaging detection technology has become an important means to ensure Industrial safety in developed countries. The application field includes electric power, metallurgy, petro-chemistry, machinery,coal, traffic, fire control and national defense, etc. It can not only carries out real-time detection at high voltage, high current and high speed operation to perform real-time detection for production and instrument but also need not power off the power supply, stop the machine or stop the production to find the potential problems and prevent occurrence of malfunction. The “non contact” modern detection technology is safe, reliable and quick. It is a type of technical revolution compared with traditional contact detection method. The infrared thermal imaging technology is widely used in the following fields:
Power equipment, transmission, transformer line inspection; Hidden fire source search in fire protection; Personnel search and rescue in the fire, and fire command; Analyze the location and heat loss of leak points in heat pipes and heating equipment; Determining the location of the heating fault of the operating train; Security department night monitoring.
Overview
This product is an infrared camera that integrates surface temperature measurement and real-time thermal image. The traditional inferred thermometer needs to measure every component one by one while it is not necessary for infrared imaging camera, thus saving time. The potential problems may be displayed on color display screen clearly. Moreover, the central point measurement cursor is used to locate quickly and accurately to measure the temperature of the target object. In order to increase the differentiation, the product is provided with a visible light camera. The thermal images and visible images are stored in the device and can be read through USB or stored in a computer to generate a report or for print. With small volume, the product is easy to operate and has strong function. it is the ideal selection for electric power, electronic manufacturing, Industrial inspection and other fields.
The following major functions increase the product’s accuracy and usability:
The radiation coefficient may be adjusted to increase the measurement accuracy of objects with half reflection surface. The highest temperature and lowest temperature cursor may guide the users to the areas with highest and lowest temperature of the thermal images. The selectable color palette.
5
6
Cleaning of the Products
The shell of this product is cleaned with a damp cloth or diluted soapy water. Do not use abrasives, isopropyl alcohol or solvents to clean the lens and screen. Use professional optical lens cleaners.
Lens Maintenance
Prevent damage of the infrared lens Clean the infrared lens carefully. The lens is provided with refined anti-reflection coating. Don’t clean with force to prevent damage of the anti-reflection coating.The selectable color palette. Use a cleaning solution for lens maintenance, such as alcohol-based commercial lens cleaners, alcohol, and a lint-free cloth or paper towel. Compressed air tanks can be used to remove loose particles.
Clean the lens: The compressed air tank or dry nitrogen ion gun (if applicable) may be used to blow the loose particles on the lens surface. Dip the lint free cloth in alcohol. Squeeze the excessive alcohol in the cloth or apply the lint free cloth on dry cloth lightly. Wipe the lens surface by making circular motion. Then discard the cloth. If it is necessary to repeat above step, please use new cloth to dip with the cleaning solution to wipe.
7
Charging of the Battery and Description
Use USB data line to charge: The product has built-in chargeable 26650 lithium batteries. When the battery level is low, the top right of the screen will display ” “”.Please charge in time through Type-C USB interfacecWhen the product is off, you can charge. Pull off the USB line after fully charging.
To make the lithium ion battery can play the perfect performance: Don’t place the battery on the charger exceeding 24 hours. The thermal imaging device should be charged for two hours at least every three months so as to extend the battery service life to the greatest extent. Don’t try to charge the battery in extremely cold environment.
8
Performance Index
Model Display screen
HT-A9
3.5-inch full-view TFT display
HT-A10
3.5-inch full-view TFT display
Infrared image resolution
320×240
256×192
Temperature measurement range
Measurement accuracy
-20 to 450
-20 to 550
-4°F to 842°F -4°F to 1022°F
-15¥ to 450¥ ±2¥ or ±2%; -20¥ to -15¥ ±4¥
-15¥ to 550¥ ±2¥ or ±2%; -20¥ to -15¥ ±4¥
Field angle Focus length
NETD
56°×42° 3.2mm 50mK @25,@F/1.0
Frame rate of thermal images Focus mode
Wavelength coverage
25Hz Fixed 8-14um
Emissivity Color palette LCD resolution Storage Image/Video Format
Adjustable from 0.01 to 1.00 Rainbow, iron, cold color, white hot,
black hot 640X480
JPG/MP4
Storage capacity
Built-in 8G (Actually available 6.6G)
9
USB
Type-C USB
Power supply
Working time Setting command
Language
Built-in chargeable 26650 battery Detachable
4 hours
Unitalanguageadateatimeainformation EnglishaChineseaItalianaGerman
Automatic power-off time
Selectable: 5 minutes/20 minutes/ not power off automatically
Product size Product weight Work temperature Storage temperature Relative humidity
255.4mm×122.1mm×97.2mm 588g
0¥to 45¥ -20¥ to 60¥
< 85RH
10
Product Description 1. Instruction to Structure
3.5 inch full view TFT display screen Key area
Handheld area
1
11
Type-C USB (Open the protective cover) Visible light camera Infrared thermal image sensor
Image capture key
Image capture key
2
12
2. Display Description
Central point temperature
Temperature
Current
range
WIFI emissivity
Battery power The lowest temperature cursor
Color code
Temperature cursor at central point
The highest temperature cursor
Maximum value
Minimum value
Time
WIFI: Search the WiFi of this product through mobile devices and access it through IP. Temperature range: The range of temperature measurement (HT-A9 automatically adjusts the temperature range, and the range icon is not displayed in the interface).
Color code: Used to mark the color corresponding to the relative temperature from low to high in the field of version.
The central point temperature cursor: Used to indicate the central position in the screen area. The cursor color displays white. The temperature value is displayed top left corner of the screen.
The highest temperature cursor: Used to indicate the highest temperature position in the screen area. It will move with the movement of the highest temperature. The cursor displays red. The temperature value is displayed at bottom left corner of the screen.
13
The lowest temperature cursor: Used to indicate the lowest temperature position in the screen area. It will move with the movement of the lowest temperature. The cursor displays green. The temperature value is displayed at the central position of the screen.
3. Key Description
Menu key/On/off key
Selection key/Entry key
Navigation key: Up, down, left and right
Initial Operation
Product boot/shutdown Press and hold the ” /MENU” button for more than 3 seconds to turn the Thermal Imaging on or off. LCD screen display After turning on the power, the screen shows the thermal imaging status.(Time adjustment may be required when you move the camera between environments with widely varying ambient temperatures.)
14
Witching between infrared thermal image and visible image Press ” ” or ” ” key to switch the degree of fusion between inferred thermal images and visible images (the degree of fusion is 0%, 25%, 50%, 75% and 100%).
Image capture Press the image capture key. When the capture is successful, the screen will display “store photo?” prompt. If “yes” is selected, please press ” /MENU” key to determine to save the image. If “no” is selected, press ” SELECT/ENTER ” key to determine not to save the image.
Video recording In the normal boot operation interface, press and hold the capture button and the screen will display the prompt “Record video?”, select “Yes” or “No” to record, press ” “” ” to switch the selection, and then press “SELECT/ENTER” to confirm , if you confirm the recording, you can short press the capture button again to record, and after the recording is completed, press and hold the capture button to end the recording(for HT-A10 products).
The function to hide highest/lowest temperature column at the screen bottom Under the operation after normal start up, press ” ” key and the screen bottom will display highest/lowest temperature column. Press ” ” can also hide it.
15
Image output The saved images through capture may be checked and output by connecting with a computer through Type-C USB. Read images Open the USB protective cover as shown in 2 . Use USB line to connect the USB port and then computer to read the images or save it into computers.images or save it into computers. The supported operating system through verification includes: winxp, win7, win 8, win10, Apple system. It is suggested to use the attached USB line or USB line with higher quality. Note: When connecting with a computer, pull off the data line after selecting “pop out device safely” to avoid causing file system damage and other problems. If “unable to save” and other problems occur, you may find the hard disc in the computer and fix it.
16
Introduction to the Menu
Press the left of “MENU/ ” key and the menu bar appears. They are “image overlapping”, “image”, “video””color palette”, “emissivity” and “setting” submenus.
1.”Image Overlapping” Submenu 1.1. Description of Image Overlapping
Image overlapping makes it easier for users to understand the infrared images by using aligned visible images and infrared images. The use of image overlapping can capture the visible image of every infrared image so as to display the temperature distribution in the target region correctly and share with other people more effectively.
1.2. Application of Image overlapping
Press the ” /MENU” button to enter the main menu, and select ” ” (Image registration) in the main menu. Press the ” SELECT/ENTER ” button to enter the image overlap adjustment mode.Press the navigation keys (up, down, left and right buttons) to perform the visible image shift operation. Press the “SELECT/ENTER” button to exit the image blending mode (Note: If there is no operation for more than 6 seconds, the image blending mode will be automatically exited).
17
2. Introduction to “image” Sub-menu 2.1. View Image
Press the ” /MENU” button to enter the main menu, and select ” ” (image) in the main menu.
171229-105030 171229-105031 171229-105032 171229-105033
As shown in the figure, Then press ”
” key to enter image list. Press
”
“or ” ” key in navigation to select the image. Then press
“SELECT/ENTER” key to view image.
When viewing the images, press ” ” key to view the precious image,
Press ” ” to view the next image.
Press ” SELECT/ENTER ” key to return. Press ” /MENU” key to exit
from the menu.
2.2. Delete Images
While viewing the image, press the ” ” key, the screen will display “Delete photo?” Select “Yes” or “No” to delete the image, press the ” “” “key, to Switch the selection, then press the”SELECT/ENTER” key, to confirm.When the image is deleted, “No Image” will be displayed. Press “SELECT/ENTER” to return to the menu and press ” /MENU” to exit the menu.
18
3. Introduction to “Video” Submenu
3.1.View Video
Press ” /MENU” key to enter the main menu, select ” menu(video), as shown below.
20220211-154307 20220211-124307 20220210-174307 20220210-164307
” in the main
Press the ” ” key to enter the video list, press the ” ” and ” ” keys in the navigation keys to select the video, and then press the “SELECT/ENTER” key to view the video. When viewing a video (not playing), press the ” ” key to view the previous video, and press the ” ” key to view the next video. Press the ” /MENU” key to exit from the menu.
3.2. Delete Video
When viewing the video (if it is not playing) press the ” ” key the screen will display “Delete video?” Select “Yes” or “No” to delete the video, press the ” “” ” key to Switch the selection, then press the”SELECT/ENTER” key to confirm.When the video is deleted, “No videos” will be displayed. Press “SELECT/ENTER” to return to the menu and press ” /MENU” to exit the menu.
19
4. Introduction to “Color Palette” Sub-menu
4.1. Color Palette Description
The palette can be used to change the pseudo-color display of the infrared image on the display. Some tune Swatches are better suited for specific applications and can be set up as needed. The palette is divided into: rainbow, iron, cold color, white hot, black hot, five palettes. These palettes work best with high thermal contrast and provide additional color contrast between high and low temperatures. Suitable selection of color palette displays the details of the target objective better. Rainbow, iron and cold color palettes focus on display of color. Such color palettes are very suitable for high heat contrast and are used to improve the color contrast between high temperature and low temperature. But the White hot and Black hot color palettes provide even linear color.
The following is the image of the same object with selection of different color palettes.
Rainbow
Iron
Cold color
White hot
Black hot
20
4.2. Application of Color Palette
Color palette
Spectra Iron Cool White Black
As shown in the figure, press ” /MENU” key to enter the main menu and
select ”
” (color palette) option and press ” ” key to enter the color
palette list. Press ” ” and ” ” keys in navigation to select the color
palette. Then press “SELECT/ENTER ” key to select the color palette.
Press ” ” to return. Press ” /MENU” key to exit from the menu.
5. Introduction to “Emissivity” Sub-menu
5.1. Emissivity Description
The emissivity of the product can be adjusted from 0.01 to 1.00 with the default value of 0.95. Many common objects and materials (such as timber, water, skin and textile fabric) can reflect the heat energy effectively. So it is easy to obtain relatively correct measurement value. The emissivity is usually set as 0.95 when the coarse objects that are easy to give out energy. For semi-matte objects that give out less energy, the emissivity is usually about 0.85 and the emissivity of semi-gloss objects is 0.6. The shiny objects are divided into materials with low radiation coefficient. The emissivity is usually set as 0.3 at the time of measurement. Correct setting of the value of emissivity is very important
21
for you to carry out the most correct temperature measurement. The surface emissivity will produce giant impact on surface temperature measured by the product. Understanding the surface emissivity will enable you to obtain correct temperature measurement result.
5.2. Emissivity Setting
The product is provided with four types of object measurement modes: Coarse object (0.95) Semi-matte object (0.85) Semi-shiny object (0.60) Shiny object (0.30)
According to the characteristics of the measured objects, users may set the emissivity value through the “self-define” option (please refer to the table of “emissivity of common materials”). The operating step is as the following:
Emissivity
Matte (e=0.95)
Semi-matte (e=0.85)
Semi-glossy (e=0.60)
Glossy (e=0.30)
Custom
0.01
As shown in the figure, press ” /MENU” key to enter the main menu and select ” “(emissivity) option and press ” ” key to enter the emissivity list.
22
Press ” ” and ” ” keys in navigation key to select the emissivity. Then press ” SELECT/ENTER” key to determine selection of the emissivity. Press ” ” key again to return.
If you select “self-defined” emissivity, press the ” SELECT/ENTER ” button
to enter the editing state.Press ”
” / ”
” keys to select the number
to be changed, press ”
” ”
” keys to change the value. After
themodification is completed, press ” SELECT/ENTER” to confirm, then
press”
” to return. The ” /MENU” button exits the menu.
5.3. The Emissivity Value of Common Materials
Substance Bitumen Concrete Cement Sand Earth Water Ice Snow Glass Ceramics Marble Gypsum Mortar Brick
Thermal radiation Substance Thermal radiation
0.90~0.98
Black cloth
0.98
0.94
Human skin
0.98
0.96
Foam
0.75~0.80
0.90 0.92~0.96
Charcoal dust Paint
0.96 0.80~0.95
0.92~0.96
Matte paint
0.97
0.96~0.98 0.83
0.90~0.95 0.90~0.94
0.94 0.80~0.90 0.89~0.91 0.93~0.96
Black rubber
Plastic Timber Paper Chromium hemitrioxide Copper oxide Ferric oxide
Textile
0.94 0.85~0.95
0.90 0.70~0.94
0.81 0.78 0.78~0.82 0.90
23
24
6. Introduction to “Setting” Sub-menu
Press ” /MENU” key to select the ”
“(setting) option in the main menu.
Press ” ” key again to enter the “setting” sub-menu.
Settings
Auto shutdown Brightness
Auto shutdown
Brightness
NO 5min 20min Low Medium Hight
Language
Language
English Chinese Italian German
Unit
Unit
Celsius Fahrenheit
H
L Temperature range
Range
lowc-20¥~120¥ highc120¥~550¥
24h Time format
Time Format
24 hour AM/PM
Set time Spot
Set time Spot
Year Month Day Hour Minute Second
Off On
2020 10 26 02 52 03
WiFi
WiFi
Off On SN:Thermal-0000
HT-19 automatically adjusts the temperature range, and the
temperature range is not displayed in the menu.
25
6.1. Auto Shutdown Setting
After entering the “Settings” sub-menu, select “MENU/ ” (automatic
shutdown), press navigationThe ”
” button in the button enters the
auto power off setting. Can be set to not automatically shut down or 5
points The clock is turned off or turned off in 20 minutes.
6.2. Intensity Settings
After selecting ”
” (brightness), press the ”
” button in the
navigation key to enter the brightness setting. Can be set to low or medium
or bright.
6.3. Language Settings
After selecting ”
” (language), press the ”
” button in the
navigation key to enter the language setting.
Available in 4 languages: English, Chinese, Italian, German.
6.4. Unit Setting
After selecting ”
” (unit), press the ” ” button in the navigation
key to enter the temperature unit setting. Can be set to Celsius or
Fahrenheit.
6.5. Tempertature Range Setting
After selecting ”
H L
” (temperature range), press the ”
” key in the
navigation keys to enter the temperature range setting. Can be set to low
temperature (-20°C to 120°C) or high temperature (120°C to 550°C).
26
6.6. Time Format Setting
After you select ” 24h “(time format), press the ”
” key in the
navigation key to enter the time format setting. Can be set to 24 hours or 12
hours.
6.7. Time Setting
As shown in the figure, after selecting ”
” (set time), press ”
”
in the navigation key to enter the setting time.
Set time
Year 2020
Month 10
H
Day
26
L
24h
Hour 02
Minute 52
Second 03
Press ” “/”
” to select year/month/day/hour/minute.
After selecting, press “SELECT/ENTER” key to enter the edit state.
Press” ” and ”
” keys to select the figure to be changed.
Press” ” /” ” key to change the value. After completing the
change, press “SELECT/ENTER” to enter.
27
After the time setting is completed, press ” ” /MENU” exit from the menu.
” key to return. Press
6.8. Enable/Disable of the Highest and Lowest Temperature Cursor
As shown in the figure, after selecting ”
” (cold hotspot), press the
”
” button in the navigation key to enter the cold hotspot setting.
H L
24h
Spot Off On
Press ” ” /” ” key to select “enable” or “disable” the option.
Then press “SELECT/ENTER” key to determine selection.
After the setting is completed,press ” “MENU/ ” key to exit from the menu.
” key to return. Press
28
6.9. Wireless WIFI on and off
As shown in the figure, after selecting ” ” (WiFi), press the ” in the navigation key to enter the WIFI setting.
” button
Click to take a photo on the mobile device, and the image will be saved on the machine synchronously, as shown in the figure below. Image view: click “Image” in the mobile device to enter the image list, and click “Infrared video streaming” to return to the video streaming page.
H L
24h
WiFi Off On SN:Thermal-0000
WIFI
Press ” ” /” ” key to select ” on ” or ” off ” the option.
Then press ” SELECT/ENTER ” key to determine selection. After the setting is completed,press ” ” key to return. Press ” /MENU” key to exit from the menu. After turning on WIFI, use the mobile device to search for WIFI, the WIFI name can be found in the local menu (as shown above); access the device through the IP address 192.168.230.1. In the mobile device, you can set the color palette, fusion, emissivity, maximum/minimum value, language conversion, and then it can be synchronized to the machine, and the settings on the machine can also be synchronized to the mobile device (Note: If not converted, the refresh on the device).
29
Enter the image list, select the image to download and press and hold to download the corresponding image, long press the image to save it to the mobile device, and click “Infrared video streaming” to return to the video streaming page.
Thermal Imaging Image Analysis Software Operation Guide
Software Installation And Operation
1. Connect the product with a USB cable, and then connect to the computer. Open the removable disk in the computer, find the “INSTALLATION PACKAGE” folder and open it, and click to install the software.
30
2. After installation, open Enter the picture analysis software interface, click “Open File”, and select the picture to be analyzed,as shown in the figure:
Interface Introduction
1. Select the language in the upper right corner of the interface, you can choose Chinese, English, and switch between the two languages. 2. On the right are shown as: fusion rate, color palette, temperature unit, picture information.
Fusion rate: Moving the slider can realize the fusion of visible light image and infrared thermal image. The left end is a visible light image, and the right end is an infrared thermal image. Palette: In the palette, click the ” ” icon to choose from five color palettes: rainbow, iron red, cold, white hot, black hot. Temperature unit: In the temperature unit, click the ” ” icon to select three temperature units: Celsius, Fahrenheit, and Kelvin.
31
Picture information: display file name, emissivity, capture time, maximum temperature, minimum temperature, center point temperature, original thermal image.
3. “Open File” in the upper left corner of the interface, open the thermal image to be read. When you need to save the picture after the operation, click “Save”(Note: the saved picture cannot be opened again with this software).
Icon Introduction
1. ”
” icon, take the temperature of the thermal image.
2. ”
“icon, select the maximum temperature and minimum temperature
of the thermal image in a straight line.
3. ”
“icon, select the thermal imaging map to select the maximum
temperature and minimum temperature.
4. ”
” icon, circle the thermal imaging map to get the maximum
temperature and the minimum temperature.
5. ”
“icon, arbitrarily circle the thermal imaging map to take the
maximum temperature and the minimum temperature.
6. ”
“Return icon, when an operation error occurs, you can click this
icon to return to the previous operation.
7. ”
“Delete icon, when you select multiple temperature values and
need to cancel all of them, click Delete.
32
Documents / Resources
![]() |
Hti HT-A9,HT-A10 Thermal Imaging Camera [pdf] Instruction Manual HT-A9, HT-A10, HT-A9 HT-A10 Thermal Imaging Camera, HT-A9 HT-A10, Thermal Imaging Camera, Imaging Camera, Camera |