essence-logo

essence TR-KPD Smart Security

essence-TR-KPD-Smart-Security-

Product Description

The TR-KPD (keypad) is an encrypted, battery-operated, wireless, access control and system arming device.

Key features include: 

  • User identity verification using a proximity RFID tag or passcode
  • MiFare® DESFire® RFID technology
  • Five-button design provides system activation controls and status indications
  • Full numeric keypad
  • Functions:
    • Arm
    • Disarm
    • Partial arm
    • Panic alarm
  • Efficient power consumption to extend battery life
  • Supports automatic over-the-air software programming and configuration upgrade (RSU)

Installing the Keypad

Ensure that you have: 

  • Four AA batteries
  • A screw and wall anchor
  • Screwdriver
  • Drill

To install the keypad: 

  1. Choose a smooth, flat indoor wall near the door.
  2. Release the keypad’s mounting base by lifting the tab and sliding the base in the tab’s direction. essence-TR-KPD-Smart-Security-fig-1
  3. Press the tamper switch several times.essence-TR-KPD-Smart-Security-fig-2
  4. Insert four fresh new AA alkaline batteries, according to the correct polarity. essence-TR-KPD-Smart-Security-fig-3
    WARNING! A new battery can explode if it is incorrectly installed.
  5. Drill a hole in the wall and insert a wall anchor.
  6. Clean and dry the wall.
  7. Peel off the mounting-tape protective strips. essence-TR-KPD-Smart-Security-fig-4
  8. Ensure that the wall anchor and tamper pin holes are aligned. essence-TR-KPD-Smart-Security-fig-5
  9. Press the wall mount into place.
  10. Insert a screw in the tamper pin hole and tighten.
  11. Align the keypad onto the mounting base, and slide the keypad into place. essence-TR-KPD-Smart-Security-fig-6

Arming and Disarming

You can use the keypad to activate the following arming modes:

  • Armed Away – Arms all devices
  • Armed Partial- Arms a specified group of devices
  • Armed Perimeter – Arms perimeter devices
  • Disarmed

Arming  essence-TR-KPD-Smart-Security-fig-7

To arm: 

  1. Press the button for the arming mode you want.
  2. If your installation requires authentication for arming, enter your numeric passcode or place your tag over theessence-TR-KPD-Smart-Security-fig-8
    Partial and perimeter arming modes can be activated at the same time.
Disarming

To disarm: 

  • If your user does not require a passcode, place the tag over theessence-TR-KPD-Smart-Security-fig-8
  • If your user is configured for passcode only, enter the passcode and press √.
  • If your user requires a tag and a passcode, enter the passcode and then place the tag over theessence-TR-KPD-Smart-Security-fig-8
Checking Arming Status

To check the system’s arming status, pressessence-TR-KPD-Smart-Security-fig-9

  • Ifessence-TR-KPD-Smart-Security-fig-10 lights are green, the system is disarmed.
  • Ifessence-TR-KPD-Smart-Security-fig-11 light red, the system is armed. The button or buttons that light indicate the arming mode.

Triggering a Panic Alarm
In case of an emergency, you can trigger a panic alarm. To trigger a panic alarm, press and hold the keypad’s SOS button for at least five seconds.    essence-TR-KPD-Smart-Security-fig-12

Changing the Batteries

To change the keypad’s batteries:

  1. Release the keypad’s mounting base by lifting the tab and sliding the keypad away from the tab.
  2. Remove the old batteries.
  3. Press the tamper switch several times. essence-TR-KPD-Smart-Security-fig-13
  4. Insert four new fresh AA alkaline batteries, according to the correct polarity.essence-TR-KPD-Smart-Security-fig-14
  5. Align the keypad onto the mounting base, and slide the keypad into place.

Specifications

Item Data
Part Number ES700TRKPD
Communications   Bi-directional protocol: ECOP – Essence proprietary communication protocol

Maximum RF range: Up to 700m (2,296 ft.) – open air

Modulation and frequency:

Europe: 868.3 MHz 2FSK

The Americas: 916.5 MHz 2FSK

RFID 106 kbps, 13.56 Mhz

Data Security

RF: 32-bit ID, over four billion combinations

RFID: 128-bit ID, DES, AES, and ECC

Security and safety   Tamper mechanism – wall tamper

Unique electronic serial number

Power supply   Keypad

Batteries: Four 1.5V AA alkaline batteries

Battery life: Three years with 10 tag-reads and 10 code entries per day

Tag: No batteries required

Dimensions   Size (H x W x D):

Keypad: 103 x 103 x 20 mm (4.1 x 4.1 x 1.2 in.)

Tag: 10 x 34 x 50 mm (0.39 x 1.34 x 1.97 in.)

Weight:

Keypad: 135 g (0.3 lbs.) – battery not included

Tag: 10 g (0.02 lbs.)

Environment   Operating ambient temperature range: -10° C – 55° C (14° F – 131° F)

Storage ambient temperature range: -20°C – 60°C (-4°F – 140°F)

Operating humidity: Up to 95% non-condensing

Item Data
Compliance Pending EMC and Radio

EN 300 220-1: V3.1.1

EN 300 220-2: V3.1.1

EN 300 330: V2.1.1

EN 301 489-1 v 1.9.2

EN 301 489-3 v 1.6.1

EN 61000-6-3: 2007 + A1:2011

EN 50130-4:2011 + A1:2014

FCC CFR 47, Part 15

IC: RSS-210

n  Safety: EN 62368: 2014

n  Performance:

EN 50131-3: 2009

EN 50131-1:2006 + A2:2017 Grade 2

EN 50131-6:2017

EN 50131-5-3: 2017

UL 2610: 2018

n  Environmental: EN 50130-5 Class II

n  RoHS: EN 50581

n  ISO: ISO 9001:2008, ISO 14000

n  RFID: ISO/IEC 14443 MIFARE Identification cards

Appendix A

Keypad Indications and Actionsessence-TR-KPD-Smart-Security-fig-15

The following table describes the keypad’s indications and actions.

 

 

 

 

Action/Status

Indication
 

 

 

Sound

essence-TR-KPD-Smart-Security-fig-10  

essence-TR-KPD-Smart-Security-fig-16

essence-TR-KPD-Smart-Security-fig-17  

essence-TR-KPD-Smart-Security-fig-18

essence-TR-KPD-Smart-Security-fig-19
Arm Away – Success Three short beeps   Lights red for two seconds      
Arm Partial 2- Success Three short beeps     Lights red for two seconds    
Arm Partial 1 – Success Three short beeps       Lights red for two seconds  
Arm Perimeter – Success Three short beeps         Lights red for two seconds
Arm – Failure One long beep Blinks red for two seconds        
Delay Arm – Countdown Countdown beeps Orange clockwise        
Delay Arm – Success Three short beeps   Lights red for two seconds      
Attempt to arm when armed away One long beep   Lights red for two seconds      
 

 

 

 

Action/Status

Indication
 

 

 

Sound

essence-TR-KPD-Smart-Security-fig-10 essence-TR-KPD-Smart-Security-fig-16 essence-TR-KPD-Smart-Security-fig-17 essence-TR-KPD-Smart-Security-fig-18 essence-TR-KPD-Smart-Security-fig-19
Attempt to arm with no devices associated with arming profile One long beep Flashes red for two seconds        
Entry delay countdown   Orange clockwise        
Disarm – Success Three short beeps Lights green for two seconds        
Disarm – Failure One long beep Blinks red for two seconds        
Attempt to disarm when already disarmed Three short beeps Lights green for two seconds        
Panic – Success Three short beeps Red clockwise for 30 seconds        
Panic – Failure One long beep Blinks red for two seconds        
Press non- numeric key when alarm in memory   Red clockwise for two seconds        
Press information – Disarmed   Lights green for two seconds        
 

 

 

 

Action/Status

Indication
 

 

 

Sound

essence-TR-KPD-Smart-Security-fig-10 essence-TR-KPD-Smart-Security-fig-16 essence-TR-KPD-Smart-Security-fig-17 essence-TR-KPD-Smart-Security-fig-18 essence-TR-KPD-Smart-Security-fig-19
Press information- Armed Away     Lights red for two seconds      
Press information- Armed Partial 2       Lights red for two seconds    
Press information- Armed Partial 1         Lights red for two seconds  
Press information – Armed Perimeter           Lights red for two seconds
Press information- Alarm in memory   Red clockwise for two seconds        
Press keys when the keypad is locked One long beep Flashes red for two seconds        
Tag Learn – Success Three short beeps Lights green for two seconds        
Tag Learn – Failure One long beep Flashes red for two seconds        
No response from panel One long beep Blinks red for two seconds        

FCC Rules

This device complies with FCC Rules Part 15 and with Industry Canada’s license-exempt RSS. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference
  2. this device must accept any interference received including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  •  Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

For Industry Canada: 

  • This Class B digital apparatus complies with Canadian ICES-003.
  • Cet appareil numerique de la classe B est conforme a la norme NMB-003 du Canada.

WARNING! To comply with FCC RF exposure compliance requirements, the device should be located at a distance of at least 20 cm from all persons during normal operation. The antennas used for this product must not be co-located or operated in conjunction with any other antenna or transmitter. Changes or modifications to this equipment not expressly approved by the party responsible for compliance (Essence Security International Ltd.) could void the user’s authority to operate the equipment.

Legal Notice
Usage of this document, and all information (including product information) provided within, are subject to the following terms and conditions, and all applicable laws. If you do not agree with these terms, please do not access or use the remainder of this document.

This document contains highly confidential information, which is proprietary to Essence Security International (E.S.I.) Ltd. and/or its affiliates (hereafter, “Essence”). No part of this document’s contents may be used, copied, disclosed or conveyed to any third party in any manner whatsoever without prior written permission from Essence.
The information included in this document is intended for your knowledge and for negotiation purposes only. Essence makes no implicit representations or warranties with respect to such information.
The information included in this document is subject to change without notice. Any decision to rely on the information contained herein shall be at your sole responsibility, and Essence will not accept any liability for your decision to use any information or for any damages resulting therefrom.

Certain laws do not allow limitations on implied warranties or the exclusion or limitation of certain damages. If these laws apply to you, some or all of the above disclaimers, exclusions, or limitations may not apply to you.
By using the information contained herein, you agree that the laws of the State of Israel, without regard to principles of conflict of laws, will govern any dispute of any sort that might arise between you and Essence regarding the information contained herein, and any such dispute shall be settled exclusively in the competent courts of Tel Aviv-Jaffa, Israel.

All registered or unregistered trademarks, product names, logos and other service marks mentioned within this document are the property of Essence or their respective owners. Nothing contained herein shall be construed as conferring by implication, estoppels, or otherwise, any license or right, either express or implied, under any patent or trademark of Essence or any third party. No use of any trademark may be made without the prior written
authorization of Essence. This document and all of its contents are protected intellectual property of Essence. Any copying, reprinting, reuse, reproduction, adaptation, distribution or translation without the prior written permission of Essence is prohibited. Please check your End User License Agreement (EULA) for terms and conditions. © 2020 All rights reserved to Essence Security International (E.S.I.) Ltd.

For more information, please contact:

Essence Security International (E.S.I.) Ltd. 12 Abba Eban Avenue,
Ackerstein Towers Bldg. D
Herzliya Pituach, 4612001 Israel
www.essence-grp.com
Tel: +972-73-2447777
Fax: +972-9-7729962

Documents / Resources

essence TR-KPD Smart Security [pdf] User Guide
ES700TRKPD, YXG-ES700TRKPD, YXGES700TRKPD, TR-KPD, TR-KPD Smart Security, Smart Security, Security

References

Leave a comment

Your email address will not be published. Required fields are marked *