Dynamic Biosensors Adapter Strand Package

Dynamic Biosensors Adapter Strand Package

Key Features

  • Adapter strand 1 – Ga and Adapter strand 2 – Ga – lfs (ligand free strand) for functionalization of heliX ® Adapter Chip on Spot 1 and Spot 2, respectively.
  • Compatible with heliX ® Adapter Chip.
  • Includes Adapter strands for 50 regenerations.
  • Ideal for MIX&RUN sample preparation.
  • Adapter strands 1 and 2 carry a moderately hydrophilic green dye (Ga) with a single negative net charge.

Adapter Chip Overview

2 spots with 2 different anchor sequences for DNA-encoded addressing.
Adapter Chip Overview

Product Description

Order Number: ASP-1-Ga

Table 1. Contents and Storage Information

Material Cap Concentration Amount Buffer Storage
Adapter strand 1 – Ga Black 400 nM 5 x 100 µL TE40 [1] -20°C
Adapter strand 2 – Ga – lfs White 200/250 nM 5 x 200 µL TE40 [1] -20°C

For research use only.

his product has a limited shelf life, please see expiry date on label.

To avoid many freeze thaw cycles please aliquot the nano lever.

Preparation | Mix&run

In-solution hybridization of adapter and ligand strands:

  1. Mix Adapter strand 1 – Ga (400 nM) and conjugated Ligand strand (500 nM) at 1:1 ratio (v/v).
  2. Incubate the solution of step 1 at RT at 600 rpm for 30 min to ensure complete hybridization.
  3. Mix solution of step 2 and Adapter strand 2 – Ga – lfs (200 nM) at 1:1 ratio (v/v).
    Preparation

Solution is ready to use for biochip functionalization.

Stability of the solution is related to the stability of the ligand molecule.

Table 2. Additional material for functionalization of spot 1 and reference spot 2.

Material Concentration Buffer Related Product Name Order No
Ligand strand carrying the conjugated ligand 500 nM PE40 [2] heliX ® Amine Coupling Kit 1 HK-NHS-1

Example

Required volume for 3 functionalizations: 100 µL with a final concentration of 100 nM.

Vial 1 Vial 2
Adapter strand 1 – Ga (400 nM) Conjugated Ligand strand (500 nM) Adapter strand 2 – Ga – lfs (200/250 nM)
25 µL 25 µL 50 µL

After incubation time, mix vial 1 and vial 2 to obtain 100 µL of ready-to-use DNA solution.

Customer Support

Contact
Dynamic Biosensors GmbH
Perchtinger Str. 8/10
81379 Munich
Germany
Bruker Scientific LLC
40 Manning Road, Manning Park
Billerica, MA 01821
USA
Order Information order@dynamic-biosensors.com
Technical Support support@dynamic-biosensors.com
www.dynamic-biosensors.com
Instruments and chips are engineered and manufactured in Germany.
©2025 Dynamic Biosensors GmbH
For Research Use Only. Not for use in clinical diagnostic procedures.
[1] TE40: 10 mM Tris, 40 mM NaCl, 0.05 % Tween20, 50 μM EDTA, 50 μM EGTA
[2] If the protein is not stable in PE40 (TE40, HE40), please check buffer compatibility with the switchSENSE®
compatibility sheet.
Logo

Documents / Resources

Dynamic Biosensors Adapter Strand Package [pdf] User Manual
Adapter Strand Package, Strand Package, Package