Introduction

The Button Manager is the User Interface to manage the physical buttons on DT Research computing system products. Most of the systems have physical buttons that allow users to quickly access certain functions, like Barcode Scanner trigger, OnScreen keyboard, Windows Key trigger, adjust system volume/screen brightness, and launch user-defined applications. Pre-defined buttons are set up for most common uses.
Access to Button Manager from Windows Desktop
The Button Manager application can be launched from the Windows System Tray. TapButton Manager Application for DT Research Systems lcon to open the Button Manager configuration user interface.Button Manager Application for DT Research Systems - fig 1The configure user interface has three major parts: Button Icons, Button Functions, Button Modes. Button Manager Application for DT Research Systems - fig 2The Button Icons are located close to physical button locations. The icons show current assigned function.
Button functions section will list all available functions for current system model.
NOTE: Different models may have different functions available.
Button modes: The button assignment for Windows logon page and normal desktop page is different. Not all functions are available for Windows logon mode. And if the system has more physical buttons, you can assign one button as “Fn” button, to make other buttons have an another set of functions by holding down the Fn button. Button Manager Application for DT Research Systems - fig 3

Assign a Function to a Button

Buttons are pre-defined for most common uses. To view/change the function assigned to a button:

  1. Tap on the button icon you want to work on, the current assigned function will be highlighted in the button function area.
  2. Select the function to assign in the button function area by tapping on the related icon.
  3. If the selected function has a 2nd level parameter, you will be prompted to input your options. For example; Brightness has the options of Up, Down, Max, Min, On/Off.
  4. Once you confirm your option, the assignment is done. You can continue to configure the rest of the buttons.

By default, all functions are configured for “Normal” desktop mode. If you want to assign a button to function under “Winlogon” mode, you need to switch the mode to “Winlogon”. Then follow the above “Assign a function to a button” to change any assignment of the button.Button Manager Application for DT Research Systems - fig 4

Button Function Descriptions

Button Manager Application for DT Research Systems lcon 1 A button with no function. You can use this function to disable one button.
Button Manager Application for DT Research Systems lcon 2 A button to launch an application within parameter. 2nd option to input necessary application path and parameter.
Button Manager Application for DT Research Systems - fig 5
Button Manager Application for DT Research Systems lcon 3 A button to define as Fn button. It needs to be combined with other buttons to function (not recommended unless you need more button functions than there are physical buttons).
Button Manager Application for DT Research Systems lcon 4 A button to launch Internet Explorer.
Button Manager Application for DT Research Systems lcon 5 A button to adjust system sound volume. 2nd option to choose volume Up, Down, and Mute.
Button Manager Application for DT Research Systems - fig 6
Button Manager Application for DT Research Systems lcon 6 A button to launch “Mobility Center”.
Button Manager Application for DT Research Systems lcon 7 A button to trigger screen rotation; 2nd option to choose rotation degree of 90, 180, 270.
Button Manager Application for DT Research Systems - fig 7
Button Manager Application for DT Research Systems lcon 8 A button to launch onscreen keyboard.
Button Manager Application for DT Research Systems lcon 9 A button to change brightness settings; 2nd option to choose brightness Up, Down, Maximum, Minimum, and screen On/Off.
Button Manager Application for DT Research Systems - fig 8
Button Manager Application for DT Research Systems lcon 10 A button to set Hot Key; 2nd option to choose Ctrl, Alt, Shift, and the key.
Button Manager Application for DT Research Systems - fig 9
Button Manager Application for DT Research Systems lcon 11 A button to trigger barcode scanner embedded in system.
Button Manager Application for DT Research Systems lcon 12 A button to trigger Camera. It only works with DTR Camera app (DTMSCAP).
Button Manager Application for DT Research Systems lcon 13 A button to trigger system Security key (Ctrl-Alt-Del combination).
Button Manager Application for DT Research Systems lcon 14 A button to trigger “Windows Key”.
Button Manager Application for DT Research Systems lcon 15 A button to launch “Control Center”, a DTR application to provide major system setting controls.

DT Research logoDT Research, Inc.
2000 Concourse Drive, San Jose, CA 95131
Copyright © 2022, DT Research, Inc. All Rights Reserved.
BBC A4 ENG 010422

Documents / Resources

DT Research Button Manager Application for DT Research Systems [pdf] User Guide
Button Manager for DT Research Systems, Button Manager, Manager, Button Manager Application for DT Research Systems, Button Manager Application, Application

References

Leave a comment

Your email address will not be published. Required fields are marked *