Control Components NCB50-FP-A2-P1 Inductive Sensor
Product Usage Instructions
- These sensors are designed for embeddable mounting in conveyor floors.
- The sensor is placed in metal base plates for mechanical protection.
- No clearance is needed between the sensor and the base plate to prevent foot injury.
- Once the metal screening is removed, the sensor can no longer be embeddable mounted.
Installation
- Ensure the sensor is securely mounted in the desired location.
- Connect the sensor’s wires according to the provided connection information.
- Check the sensor’s LED indicators to verify proper function.
Operation
- Apply the operating voltage within the specified range (10 – 60 V DC) to the sensor for it to function correctly.
- The sensor has a rated operating distance of 50 mm. Ensure the target object falls within this range for accurate detection.
Maintenance
- Regularly inspect the sensor for any damage or obstructions that may affect its performance.
- Ensure the sensor’s connections are secure to prevent any electrical issues.
FAQ
- Q: What should I do if the sensor’s LED indicators do not light up?
- A: Check the power supply and connections to ensure proper voltage is reaching the sensor. If the issue persists, contact customer support for further assistance.
- Q: Can the sensor be used in environments with high temperatures?
- A: The ambient temperature range for this sensor is not specified for high-temperature environments. Operating the sensor within its specified temperature range is recommended for optimal performance.
Dimensions
Technical Data
General specifications | ||
Switching function complementary | ||
Output type | PNP | |
Rated operating distance | sn | 50 mm |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | sa | 0…. 40.5 mm |
Reduction factor rAl | 0.38 | |
Reduction factor rCu | 0.35 | |
Reduction factor r304 | 0.83 |
Output type | 4-wire | |
Nominal ratings | ||
Operating voltage | UB | 10 … 60 V DC |
Switching frequency | f | 0 … 80 Hz |
Hysteresis | H | typ. 3 % |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | Ud | ≤ 3 V |
Operating current | IL | 0 … 200 mA |
Off-state current | Ir | 0…. 0.5 mA |
No-load supply current | I0 | ≤ 20 mA |
Time delay before availability | tv | ≤ 300 ms |
Operating voltage indicator | LED, green | |
Switching state indicator | LED, yellow | |
Functional safety-related parameters | ||
MTTFd 670 a | ||
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN IEC 60947-5-2 | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CCC approval | Certified by China Compulsory Certification (CCC) | |
Ambient conditions | ||
Ambient temperature -25 … 70 °C (-13 … 158 °F) | ||
Mechanical specifications | ||
Connection-type screw terminals | ||
Information for connection | A maximum of two conductors with the same core cross-section may be mounted on one terminal connection!
tightening torque 1.2 Nm + 10 % |
|
Core cross-section | up to 2.5 mm2 | |
Minimum core cross-section | without wire end ferrules 0.5 mm2 , with connector sleeves 0.34 mm2 | |
Maximum core cross-section | without wire end ferrules 2.5 mm2 , with connector sleeves 1.5 mm2 | |
Housing material | PBT | |
Sensing face | PBT | |
Housing base | PBT | |
Degree of protection | IP68 | |
Mass | 445 g | |
Dimensions | ||
Height | 40 mm | |
Width | 84 mm | |
Length | 84 mm |
Connection
Mounting
- These sensors are specially designed for embeddable mounting in conveyor floors.
- Due to its precise location in metal base plates, the sensor is afforded a high degree of mechanical protection.
- No clearance is required between the sensor and the base plate, avoiding the need for protective guarding to prevent possible foot injury.
- The large sensing range ensures positive detection and thus provides consistent control and monitoring of the conveyor.
Warning!
Once the metal screening has been removed, the sensor can no longer be embeddable mounted.
CONTACT
- Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
- Pepperl+Fuchs Group
- www.pepperl-fuchs.com
- USA: +1 330 486 0001
- fa-info@us.pepperl-fuchs.com
- Germany: +49 621 776 1111
- fa-info@de.pepperl-fuchs.com
- Singapore: +65 6779 9091
- fa-info@sg.pepperl-fuchs.com
Documents / Resources
![]() |