Control-Components-LOGO

Control Components NCB50-FP-A2-P1 Inductive Sensor

Control-Components-NCB50-FP-A2-P1-Inductive-Sensor-PRODUCT

Product Usage Instructions

  • These sensors are designed for embeddable mounting in conveyor floors.
  • The sensor is placed in metal base plates for mechanical protection.
  • No clearance is needed between the sensor and the base plate to prevent foot injury.
  • Once the metal screening is removed, the sensor can no longer be embeddable mounted.

Installation

  • Ensure the sensor is securely mounted in the desired location.
  • Connect the sensor’s wires according to the provided connection information.
  • Check the sensor’s LED indicators to verify proper function.

Operation

  • Apply the operating voltage within the specified range (10 – 60 V DC) to the sensor for it to function correctly.
  • The sensor has a rated operating distance of 50 mm. Ensure the target object falls within this range for accurate detection.

Maintenance

  • Regularly inspect the sensor for any damage or obstructions that may affect its performance.
  • Ensure the sensor’s connections are secure to prevent any electrical issues.

FAQ

  • Q: What should I do if the sensor’s LED indicators do not light up?
    • A: Check the power supply and connections to ensure proper voltage is reaching the sensor. If the issue persists, contact customer support for further assistance.
  • Q: Can the sensor be used in environments with high temperatures?
    • A: The ambient temperature range for this sensor is not specified for high-temperature environments. Operating the sensor within its specified temperature range is recommended for optimal performance.

Dimensions

Control-Components-NCB50-FP-A2-P1-Inductive-Sensor-FIG-1

Technical Data

General specifications
Switching function                                                           complementary
Output type   PNP
Rated operating distance sn 50 mm
Installation   flush
Output polarity   DC
Assured operating distance sa 0…. 40.5 mm
Reduction factor rAl   0.38
Reduction factor rCu   0.35
Reduction factor r304   0.83
Output type   4-wire
Nominal ratings
Operating voltage UB 10 … 60 V DC
Switching frequency f 0 … 80 Hz
Hysteresis H typ. 3 %
Reverse polarity protection   reverse polarity protected
Short-circuit protection   pulsing
Voltage drop Ud ≤ 3 V
Operating current IL 0 … 200 mA
Off-state current Ir 0…. 0.5 mA
No-load supply current I0 ≤ 20 mA
Time delay before availability tv ≤ 300 ms
Operating voltage indicator   LED, green
Switching state indicator   LED, yellow
Functional safety-related parameters
MTTFd                                                                             670 a
Mission Time (TM)   20 a
Diagnostic Coverage (DC)   0 %
Compliance with standards and directives
Standard conformity
Standards   EN IEC 60947-5-2
Approvals and certificates
UL approval   cULus Listed, General Purpose
CCC approval   Certified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature                                                       -25 … 70 °C (-13 … 158 °F)
Mechanical specifications
Connection-type screw terminals
Information for connection   A maximum of two conductors with the same core cross-section may be mounted on one terminal connection!

tightening torque 1.2 Nm + 10 %

Core cross-section   up to 2.5 mm2
Minimum core cross-section   without wire end ferrules 0.5 mm2 , with connector sleeves 0.34 mm2
Maximum core cross-section   without wire end ferrules 2.5 mm2 , with connector sleeves 1.5 mm2
Housing material   PBT
Sensing face   PBT
Housing base   PBT
Degree of protection   IP68
Mass   445 g
Dimensions    
Height   40 mm
Width   84 mm
Length   84 mm

Connection

Control-Components-NCB50-FP-A2-P1-Inductive-Sensor-FIG-2

Mounting

  • These sensors are specially designed for embeddable mounting in conveyor floors.
  • Due to its precise location in metal base plates, the sensor is afforded a high degree of mechanical protection.
  • No clearance is required between the sensor and the base plate, avoiding the need for protective guarding to prevent possible foot injury.
  • The large sensing range ensures positive detection and thus provides consistent control and monitoring of the conveyor.

Control-Components-NCB50-FP-A2-P1-Inductive-Sensor-FIG-3

Warning!
Once the metal screening has been removed, the sensor can no longer be embeddable mounted.

CONTACT

Documents / Resources

Control Components NCB50-FP-A2-P1 Inductive Sensor [pdf] Owner's Manual
NCB50-FP-A2-P1 Inductive Sensor, NCB50-FP-A2-P1, Inductive Sensor, Sensor

References

Leave a comment