contacta V22 Series Hearing Loop Driver User Guide

Product Overview
Our highly efficient V22 hearing loop driver is built around high-end technology designed for the flagship V Series PRO hearing loop driver range. It is suitable for driving the most demanding perimeter loop systems in medium to large venues.
With a Class-D amplifier output stage, the V22 delivers a high enough current to drive even the toughest loop loads.
The audio subsystem is built around an advanced DSP core. Combined with a microprocessor control that ensures peak performance, the driver uses cutting edge technology to deliver peak performance.
Note: For large area hearing loop installation instructions, consult the Large Area Hearing Loop Installation Guide.
Components
- Rubber Feet x 4
- 2-way 3.5mm Euro-Block Connector x 2
- 3-way 3.5mm Euro-Block Connectors x3
- 4-way Terminal Block
- Hearing Loop Stickers
- V22 Hearing Loop Driver
- User Guide
- IEC Power Lead*
- Rack Mounting Ears
- Compliance Certificate
Plug type varies by country.
Cable & Equipment: A length of loop cable determined by the loop design is also required. Hearing loop drivers also require ancillary equipment for audio feeds, such as a microphone or sound system.
Connections
- Power Supply Input*
- Factory Use (no user input)
- Line Input – 3.5mm Euro-block balanced line input
- 100V Line Input – 3.5mm Euro-block transformer isolated & balanced
- MP3 (Line Level Input) – 3.5mm Euro-block transformer isolated & balanced
- Line/Microphone – 3.5mm Euro-block – switchable phantom power (12V)
- Line Output – 3.5mm Euro-block**
- Loop Output – 5.08mm 4-way terminal block
* Power Sources – This product should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply to your home, consult your product dealer or local power company.
The primary method of isolating the amplifier from the mains supply is to disconnect the mains plug. Ensure that the mains plug remains accessible at all times. Unplug the AC power cord from the AC outlet if the unit will not be used for several months or more.
**Line Output – The Line Output on the V22 allows further V22s to be “chained” from the first V22. It will feed the Line Input [3] on the next V22 and is a simple mix of the two inputs to which the driver time delay (see page 18), if used, has been applied. This means that the time delays of a chain of V22s is cumulative and may be adjusted to suit large auditoriums.
The Line Output is not processed by the V22’s Automatic Gain Control (see page 14). The AGC, if used, is only applied to the Loop Output [8]. This prevents the drivers’ Line Outputs from cascading multiple AGC stages down the chain. It is therefore important to set the input gain on each V22 in the chain to maintain the level in the chain. The Line Output is not phased and cannot be used to create phased pairs of V22s.
Connection Examples
Balanced Inputs
MP3 Connections
Suitable Cable Lengths
The tables in this section show the approximate maximum cable lengths for differing maximum required currents to achieve a 400mA/m field strength.
Loop impedance (at 1.6kHz) should be less than voltage capability of the driver (22V) divided by the required current.
The minimum loop resistance (DCR) is 0.25Ω.
V22 Single-Turn (Metric)
Current | 1A | 2A | 3A | 4A | 5A | 6A | 7A | 8A | 9A | 10A | 11A | 12A | ||
Impedance | 22.6W | 11.3W | 7.53W | 5.65W | 4.52W | 3.77W | 3.23W | 2.83W | 2.51W | 2.26W | 2.05W | 1.88W | ||
Cable Type | Cable Length | |||||||||||||
Max. Cable Length | Round Cable (AWG) | 1.5mm | 970.99m | 485.50m | 323.66m | 242.75m | 194.20m | 161.83m | 138.71m | 121.37m | 107.89m | 97.10m | 88.27m | 80.92m |
2.5mm | 1091.74m | 545.87m | 363.91m | 272.94m | 218.35m | 181.96m | 155.96m | 136.47m | 121.30m | 109.17m | 99.25m | 90.98m | ||
Flat Cable (Width) | 10mm | 614.41m | 307.21m | 204.80m | 153.60m | 122.88m | 102.40m | 87.77m | 76.80m | 68.27m | 61.44m | 55.86m | 51.20m | |
12.5mm | 1161.97m | 580.99m | 387.32m | 290.49m | 232.39m | 193.66m | 166.00m | 145.25m | 129.11m | 116.20m | 105.63m | 96.83m | ||
25mm | 1538.27m | 769.13m | 512.76m | 384.57m | 307.65m | 256.38m | 219.75m | 192.28m | 170.92m | 153.83m | 139.84m | 128.19m |
V22 Single-Turn (Imperial)
Current | 1A | 2A | 3A | 4A | 5A | 6A | 7A | 8A | 9A | 10A | 11A | 12A | ||
Impedance | 22.6W | 11.3W | 7.53W | 5.65W | 4.52W | 3.77W | 3.23W | 2.83W | 2.51W | 2.26W | 2.05W | 1.88W | ||
Cable Type | Cable Length | |||||||||||||
Max. Cable Length | Round Cable (AWG) | 18AWG | 2552.86ft | 1276.43ft | 850.95ft | 638.21ft | 510.57ft | 425.48ft | 364.69ft | 319.11ft | 283.65ft | 255.29ft | 232.08ft | 212.74ft |
14AWG | 3408.47ft | 1704.23ft | 1136.16ft | 852.12ft | 681.69ft | 568.08ft | 486.92ft | 426.06ft | 378.72ft | 340.85ft | 309.86ft | 284.04ft | ||
Flat Cable (Width) | 18AWG
(equiv.) |
2871.76ft | 1435.88ft | 957.25ft | 717.94ft | 574.35ft | 478.63ft | 410.25ft | 358.97ft | 319.08ft | 287.18ft | 261.07ft | 239.31ft | |
14AWG
(equiv.) |
4538.17ft | 2269.08ft | 1512.72ft | 1134.54ft | 907.63ft | 756.36ft | 648.31ft | 567.27ft | 504.24ft | 453.82ft | 412.56ft | 378.18ft |
V22 Double-Turn Hearing Loop (Metric)
Current | 1A | 2A | 3A | 4A | 5A | 6A | 7A | 8A | 9A | 10A | 11A | 12A | ||
Impedance | 22.6W | 11.3W | 7.53W | 5.65W | 4.52W | 3.77W | 3.23W | 2.83W | 2.51W | 2.26W | 2.05W | 1.88W | ||
Cable Type | Cable Length | |||||||||||||
Max. Cable Length | Round Cable (AWG) | 1.5mm | 650.61m | 325.31m | 216.87m | 162.65m | 130.12m | 108.44m | 92.94m | 81.33m | 72.29m | 65.06m | 59.15m | 54.22m |
2.5mm | 683.46m | 341.73m | 227.82m | 170.87m | 136.69m | 113.91m | 97.64m | 85.43m | 75.94m | 68.35m | 62.13m | 56.96m | ||
Flat Cable (Width) | 10mm | 537.58m | 268.79m | 179.19m | 134.39m | 107.52m | 89.60m | 76.80m | 67.20m | 59.73m | 53.76m | 48.87m | 44.80m | |
12.5mm | 831.19m | 415.60m | 277.06m | 207.80m | 166.24m | 138.53m | 118.74m | 103.90m | 92.35m | 83.12m | 75.56m | 69.27m | ||
25mm | 984.36m | 492.18m | 328.12m | 246.09m | 196.87m | 164.06m | 140.62m | 123.05m | 109.37m | 98.44m | 89.49m | 82.03m |
V22 Double-Turn Hearing Loop (Imperial)
Current | 1A | 2A | 3A | 4A | 5A | 6A | 7A | 8A | 9A | 10A | 11A | 12A | ||
Impedance | 22.6W | 11.3W | 7.53W | 5.65W | 4.52W | 3.77W | 3.23W | 2.83W | 2.51W | 2.26W | 2.05W | 1.88W | ||
Cable Type | Cable Length | |||||||||||||
Max. Cable Length | Round Cable (AWG) | 18AWG | 1864.96ft | 932.48ft | 621.65ft | 466.24ft | 372.99ft | 310.83ft | 266.42ft | 233.12ft | 207.22ft | 186.50ft | 169.54ft | 155.41ft |
14AWG | 2131.29ft | 1065.65ft | 710.43ft | 532.82ft | 426.26ft | 355.22ft | 304.47ft | 266.41ft | 236.81ft | 213.13ft | 193.75ft | 177.61ft | ||
Flat Cable (Width) | 18AWG
(equiv.) |
2254.91ft | 1127.45ft | 751.64ft | 563.73ft | 450.98ft | 375.82ft | 322.13ft | 281.86ft | 250.55ft | 225.49ft | 204.99ft | 187.91ft | |
14AWG
(equiv.) |
2958.49ft | 1479.24ft | 986.16ft | 739.62ft | 591.70ft | 493.08ft | 422.64ft | 369.81ft | 328.72ft | 295.85ft | 268.95ft | 246.54ft |
Driver Area Coverage
Note: A full site survey of an installation area is recommended for optimal loop design.
Areas detailed in the table below are valid only when the following conditions are met:
- Area is at the maximum current the driver is capable of delivering without voltage clipping at 1.6KHz
- Loop layout is designed to achieve 0dB in the centre
- 25mm x 0.1mm flat copper cable
- Loop is installed in the floor
- Listening height 1.2m (large perimeter loops may have areas where the actual signal level is higher than required)
Voltage | Current |
22V | 12A |
Area | ||
1:1 | 1:2 | 1:3 |
715.0sqm | 899.0sqm | 961.0sqm |
7692.0sqft 9 | 9672.0sqft | 10338.0sqft |
Controls
Front Panel Overview
- Clip Status Light – When lit, this status LED indicates the signal on the hearing loop output is clipping (see Troubleshooting on page 26 for appropriate solutions).
- Open Circuit Loop – Indicates the status of the Loop integrity
- Display Screen – Indicates the status of the Loop Output, displays menu and adjustment options.
- Control Dial – Used for unlocking and making adjustments.
Start-Up Sequence
When power is applied the hearing loop driver will automatically perform an analysis of the loop connected to the output.
When the analysis is complete, the following screen should display:
Rotating or pressing the control will display the unlock screen.
Should an error occur during start up, please consult warning and error messages page 26.
Locking/Unlocking the Hearing Loop Driver
The hearing loop driver will power up in Output Current Display Mode and will be locked from entering Adjustment Mode.
Unlock the Driver
- To unlock the hearing loop driver, press the control dial, and when prompted “Unlock driver?” click “Yes.”
- Enter the passcode 2239:
- Rotate the control clockwise to select the first required digit.
- Press the control dial in to select the digit.
- Repeat steps (a) and (b) until all the digits have been selected.
Note: Entering the wrong code returns the driver to the lock screen.
Modes
Main Menu
After being unlocked, the hearing loop driver will display the main menu. This is indicated by up and down arrow on the display screen.
When in this mode, rotating the hearing loop driver’s control dial clockwise will move the screen to the next menu item and rotating the dial anti-clockwise will move it to the previous menu item.
The menu options are as follows:
- Loop Output
- Loop Drive Set
- AGC On/Off
- Input A Level
- Input B Level
- Phantom Power Input B
- High-Frequency Compensation
- Input High Pass Filter
- Acoustic Delay
- Backlight Timeout
- Diagnostics
Adjustment Mode
Press the control dial in to enter Adjustment Mode; the arrows on the display screen will move to a left and right position. Rotate the dial clockwise or anti-clockwise to make the adjustment. Press the control dial in to confirm the selection and return to the main menu.
If the control dial is not used for 120 seconds when in Adjustment Mode the hearing loop driver will revert to the main menu, with Loop Output as the default screen.
Locking/Rebooting the Unit
To lock the V22 when not in adjustment mode, press and hold the control dial for 5 seconds.
If an error message is displayed, reboot the driver by pressing and holding the control dial for 5 seconds.
Loop Output
The hearing loop driver’s Loop Output section displays the real-time output current, both graphically in 1A steps and numerically in 0.1A steps.
Loop Drive Set
The hearing loop driver’s Loop Drive Set section displays the real-time output current in 1A steps.
Adjustments
In Adjustment Mode, the real-time current is displayed on the top line in 1A steps. The bottom line indicates the strength of the loop output level adjustment.
- To increase the loop output level, rotate the control dial clockwise.
- To decrease the loop output level, rotate the control dial anti-clockwise.
- Press the control dial once to confirm the selection and return to the Loop Drive Set menu.
AGC On/Off
The AGC function can be switched on or off from this screen. For normal set-up and operation and optimal performance it is recommended the AGC is left on.
Adjustments
Rotating the control dial clockwise or anti-clockwise in Adjustment Mode will toggle the AGC on or off. Press the control dial once to confirm the selection and return to the main menu.
Input A Level
Input A/Isolated can be adjusted over a range of 47dB. The text on the display indicates if the correct line level has been achieved:
- “Low” indicates the line level is too low for the automatic gain control to operate.
- “Good” indicates the level is at an optimum level for the automatic gain control to operate.
- “High” indicates the level is too high and signal clipping may occur. Signal clipping will also be shown by the LED
Adjustments
Enter Adjustment Mode and alter the level displayed on the bar until the text displays ‘Good’. It is recommended that at least 5 blocks in the adjustment block are filled.
- To increase the input level, rotate the control dial clockwise.
- To decrease the input level, rotate the control dial anti-clockwise.
- Press the control dial once to confirm the selection and return to the main menu.
Input B Level
Input B can be used for either line level or microphone level signals and can be adjusted over a range of 47dB.
The top line of the display indicates if the correct microphone input level has been achieved:
- “Low” indicates the level is too low for the automatic gain control to operate.
- “Good” indicates the level is at an optimum level for the automatic gain control to operate.
- “High” indicates the level is too high and signal clipping may occur. Signal clipping will also be shown by the LED.
Adjustments
Enter Adjustment Mode and alter input level displayed on the bar until the text displays ‘Good’. It is recommended that at least 5 blocks in the adjustment block are filled.
- To increase the input level, rotate the control dial clockwise.
- To decrease the input level, rotate the control dial anti-clockwise.
- Press the control dial once to confirm the selection and return to the main menu.
Phantom Power Input B
Phantom power for a connected microphone is set off as the default setting. If required by the connected microphone, enable phantom power.
Adjustments
Rotating the control dial clockwise or anti-clockwise in Adjustment Mode will toggle the phantom power on or off. Press the control dial once to confirm the selection.
High-Frequency Compensation
There are 7 levels of high-frequency compensation available to adjust for metal loss. Your hearing loop driver will have high-frequency compensation turned to the lowest setting as its default.
Adjustments
To alter the high-frequency compensation level, enter Adjustment Mode:
- To increase the high-frequency compensation level, rotate the control dial clockwise.
- To decrease the high-frequency compensation level, rotate the control dial anti-clockwise.
- Press the control dial once to confirm the selection and return to the main menu.
Input High Pass Filter
This feature removes low-frequency sounds from the hearing loop when background noise such as air conditioners might impact users. Select either 150Hz or 180Hz if required.
Adjustments
Rotating the control dial clockwise or anti-clockwise in Adjustment Mode to toggle between the 150Hz and 180Hz cut-off or turn the filter off. Press the to dial once to confirm the selection and return to the main menu.
Acoustic Delay
In theatres, stadiums, and other large venues, sound sent from speakers will be impacted by the speed of sound, whereas audio sent through a hearing loop will reach a user instantly. This means the two sounds must be aligned or users will hear a constant echo.
Adjustments
Alter syncing and compensate for latency.
- To increase the delay, rotate the control dial clockwise.
- To decrease the delay, rotate the control dial anti-clockwise.
- Press the control dial once to confirm the selection and return to the main menu.
Backlight Timeout
Rotating the control dial clockwise or anti-clockwise in Adjustment Mode will toggle the screen’s backlight on or off. Press the control dial once to confirm the selection.
Diagnostics
This screen displays the connected loop’s resistance (R ohms) and loop Inductance (L uH).
Rotating the control dial clockwise displays the internal heatsink temperature and fan PWM (100% is fan full speed):
Rotating the control dial clockwise again displays the internal power supply voltages:
Rotating the control dial clockwise again displays the UID unique identification for the driver.
Hearing Loop Setup
Warning: Ensure the AGC setting is on before proceeding. To ensure optimal performance, setup should be performed in following order:
Required for Setup
- TSG – Contacta Test Signal Generator (TSG1)
- FSM – Contacta Field Strength Meter (IL-CONTACTA-FSM)
- Tripod or similar for mounting the FSM is recommended
- ‘Compliance Certificate’ document
Note
Throughout set-up, record values on the provided Compliance Certificate document whenever you see the following icon:
The Compliance Certificate document confirms compliance with IEC-60118:4 if your values are within acceptable levels.
It is highly recommended that you retain a copy of the completed Compliance Certificate document for your records and provide a copy to the relevant facilities manager.
Step 1: Background Noise Level
This test should be performed prior to loop installation.
- Set up the FSM, ensuring that the two vertical arrows in the top-right corner of the device are placed at the correct height:
1.2 metres (3’ 9”) for seated user.
- .7 metres (5’ 6”) for standing users. A tripod or similar for mounting the FSM is recommended.
- Any lights or equipment normally active in the surrounding area should be turned on to ensure an accurate testing environment.
- Set the FSM to the Background Noise mode – “A-weighted”.
Measure and note the background noise level throughout the looped area on the Compliance Certificate document.
- Listen to the loop through the FSM (A-weighted) or a loop listener (A-weighted). Note and demonstrate any interference to the customer which may not be heard through a hearing instrument.
- Background magnetic noise should ideally be between -32dB and -60dB. If the readings noted pass the Compliance Certificate document’s requirements, move on to Step 2: Metal Loss.
Step 2: Metal Loss
- Set up the FSM, ensuring that the two vertical arrows in the top-right corner of the device are placed at the correct height:
1.2 metres (3’ 9”) for seated user.
- 1.7 metres (5’ 6”) for standing users.
A tripod or similar for mounting the FSM is recommended.
- Connect the TSG to the line input of the hearing loop driver.
- Set the TSG to the 1kHz setting.
- Set the FSM to the Third Octave F= 1000Hz setting.
- Adjust the line level until “Good” is displayed.
- Adjust the drive level to achieve 2 amps of output current.
Set the TSG to the pink noise setting and record the value measured by the FSM.
Set the FSM to the Third Octave F= 100Hz setting and record the value measured.
Set the FSM to the Third Octave F= 5000Hz setting and record the value measured.
If the difference between the values measured at 1000Hz and 5000Hz is less than 3dB, record the results and move on to
Step 3: Output Level and Clipping. If the difference is higher than 3dB, move on to step 11.- Increase the HF comp and repeat steps 3 to 10.
Step 3: Output Level and Clipping
Note: This test should be performed as briefly as possible.
- Set the TSG to the 1kHz setting.
- Set the FSM to the RMS/Peak A-Weighted mode.
- Adjust the drive level to achieve 2 amps of output current.
- Measure the field strength. Achieve 0dB by using the FSM’s indicated field strength to work out the extra current required. For example: if the measured field strength on the FSM is (A-RMS) -6dB then 6dB (2X) extra current will be required to achieve 0dB (see Note 1 on page 24).
Note: If more than 15.5dB is required to achieve 0dB, a different loop design or more powerful driver is required. This is potentially due to metal loss. - Briefly alter the current to the desired level. For instance, the example in step 4 requires 4 amps of current.
- The field strength will now be 0dB +/- 1dB.
Quickly record the current required to achieve 0dB field strength. Now switch the TSG to 1.6kHz.
- Confirm that the Clip LED remains unlit.
- If the driver’s front panel Clip LED remains unlit, return the TSG to 1kHz and reduce output current to 2 amps move on to Step 4: Field Uniformity
If the driver’s front panel Clip LED is lit, the driver is clipping. This means the loop connected is too long, and therefore:
- The system is not IEC60118-4 compliant
- The sound will be distorted
- The driver may be susceptible to damage and warranty voided
Perform one of the following solutions and repeat until there is no clipping:
- Reduce the loop current
- Reduce the length of the loop
- Use a heavier gauge of cable
- Try a two-turn loop
- Use a higher voltage driver
Step 4: Field Uniformity
- Set up the FSM. Ensure that the two vertical arrows in the top-right corner of the FSM are placed at the correct height:
1.2 metres (3’ 9”) for seated user.
- 1.7 metres (5’ 6”) for standing users.
A tripod or similar for mounting the FSM is recommended.
- . Reduce the loop output current to 2 amps.
Set the FSM to the RMS/Peak A-Weighted mode and record the value measured by the FSM in the centre of the loop.
Move the FSM to other positions within the looped area and record the values measured by the FSM.
- The differences measured in other positions should not be greater than +/- 3dB of that measured in the first position.
- Repeat steps 3 to 5 to create a suitable map of the area looped.
Step 5: Final Output Level Adjustment
- Set the TSG to 1kHz.
- Adjust the output current to the level recorded in Step 3: Output Level and Clipping (7) on page 22. Once the current is set, disconnect the TSG.
Step 6: Input Signal Level Adjustment
- Connect the system signal source.
- Adjust the input level (line/mic) level until “Good” is displayed on audio peaks.
- The system is now set up.
Note 1:
When adjusting the output current, if a level of 6 amps is reached and yet the field strength is still below -6dB, the correct field strength will not be achieved.
This is caused by either an incorrect loop design or installation, more metal loss than expected or an incorrectly specified driver.
There is no need to go higher than +0dB ARMS.
Adjustment to drive current/level required based on the measured field strength:
Measured Field Strength | Output current that will achieve 0dB |
6.00dB | 1.00A |
5.00dB | 1.12A |
4.00dB | 1.26A |
3.00dB | 1.42A |
2.00dB | 1.59A |
1.00dB | 1.78A |
.00dB | 2.00A |
-1.00dB | 2.24A |
-2.00dB | 2.52A |
-3.00dB | 2.83A |
-4.00dB | 3.17A |
-5.00dB | 3.56A |
-6.00dB | 3.99A |
-7.00dB | 4.48A |
-8.00dB | 5.02A |
-9.00dB | 5.64A |
-10.00dB | 6.32A |
-11.00dB | 7.10A |
-12.00dB | 7.96A |
-13.00dB | 8.93A |
-14.00dB | 10.02A |
-15.00dB | 11.25A |
Troubleshooting
Symptom | Possible Fault | Action |
The driver does not turn on. |
|
|
Interference (buzzing/ whistling/hissing) is heard through induction loop. |
|
|
The driver is excessively hot to touch. |
|
|
The loop output level indicates current is flowing but I hear nothing in the loop. |
|
|
The sound is distorted. |
|
|
Clipping Status Lights are lit. | The connected hearing loop is too long. |
|
Please contact your distributor (or Contacta if appropriate) if you are experiencing technical difficulties with the product.
Warning / Error Messages
When power is applied, the hearing loop driver will automatically perform an analysis of the loop connected to the output.
The following messages indicate an error has been detected:
Main PSU Fault
This message indicates an error with the main internal power supply.
The mains power should be recycled, or a reboot initiated. If the warning still appears, disconnect the power supply and contact your distributor (or Contacta if appropriate).
Aux PSU Fault
This message indicates an error with the auxiliary power supply.
The mains power should be recycled or a reboot initiated. If the warning still appears, disconnect the power supply and contact your distributor (or Contacta if appropriate).
Loop Open or High Res
This message indicates that the loop connected is either open circuit (not connected) or is very high resistance.
The power should be removed, and loop and feeder cables should be checked with an ohmmeter to confirm continuity (too long/small gauge).
Impedance Error
This message indicates that the loop connected has characteristics that are not expected with typical loops.
The mains power should be removed, or the unit rebooted. Then, check the loop and feeder cables. Contact your distributor (or Contacta if appropriate) if the error persists.
Loop Fault
This indicates the driver has detected a general fault with the output.
This message can be displayed during start up or during operation. Contact your distributor (or Contacta if appropriate) if the error persists.
Loop Open
During normal operation, this message indicates that the loop is open circuit; the Open Circuit Loop led on the front panel will also be lit
The mains power should be removed. Then, check the loop and feeder cables. Contact your distributor (or Contacta if appropriate) if the error persists.
Loop Short or Low R
This indicates the driver has detected that either the loop connected has a very low resistance (<0.25Ω) or there is a short circuit on the output.
This message can be displayed during start up. If displayed, remove the power and check the loop.
Low resistance can be caused by a loop that is too short or is using a heavy gauge of cable. There may also be a short between conductors at the end of a feeder cable.
Contact your distributor (or Contacta if appropriate) if the error persists.
Technical Specification
Power
- Voltage: 100V-120V /200V-240V AC (Universal auto switching)
- Frequency: 50Hz-60Hz
- Power: 175W
- Connection: IEC
Inputs
- 1 X Input A 3.5mm Euro-block [optimised for -10dBV to 0dBv]
- 1 X 100V Line Input (Transformer isolated) 3.5mm Euro-block
- 1 X MP3 Input (Line level, transformer isolated) 3.5mm Euro-block
- 1 X Input B Line/Microphone (12V phantom power via 680Ω) [optimised for levels above -45dBv to -10dBv] 3.5mm Euro-block
Output Characteristics
- Output Voltage: 22Vrms (62.04Vpk-pk) @ 12Arms (33.84Apk-pk) see notes 1 and 2
- Output Current: 12Arms (33.84Apk-pk) up to 300 seconds
- Loop Connector: 4 Way 5.08mm Euro block
- Induction loop performance compliant with BS EN60118-4 (when correctly installed)
Audio system
- Frequency Response: 80Hz to 9kHz
- Distortion: THD+N <1% (-40dB)
- AGC: Switchable (Peak detecting)
- HF Comp: 7 optimised stages
- Acoustic Time Delay 10ms to 70ms adjustable in 1ms steps
- Low cut filter Selectable 150Hz or 180Hz
Display & Control
- Display: LED Backlit LCD display
- Control: Single rotary control
Fault Monitoring and Protection
- Main Display: Open circuit loop (DCR measurement)
- Loop ground fault
- Front Panel LED: Output voltage clipping
- Cooling: Internal heatsinks with thermal protection
Physical
- Height: 42mm (1.65”)
- Depth: 149.9mm (5.9”)
- Width: 432.9mm (17.04”)
- Weight: 938g
Standards
Directive Number | Directive Title |
2014/30/EU | The Electromagnetic Compatibility Directive |
2014/35/EU | The Low Voltage Directive |
2012/19-EU | The Waste Electrical & Electronic Equipment Directive |
2011/863/EU | The Restriction of Hazardous Substances Directive |
This product has been designed and tested to comply with the following North American and Canadian standards:
- FCC class “B” EMC (emissions)
- ICES-003
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
CAUTION: Changes or modifications not expressly approved by Contacta Systems LTD or an authorised partner could void the user’s authority to operate the equipment.
Correct disposal of this product
This marking indicates that this product should not be disposed with other household waste throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal and to conserve material resources, this product should be recycled responsibly. To dispose of your product, please use your local return and collection systems or contact the retailer where the product was purchased.