CASAMBI SR-CS9041A-R Smart Relay Module Instruction Manual

SR-CS9041A-R Smart Relay Module

Product Information

Specifications:

  • Input Voltage: 100-240Vac
  • Output Voltage: 100-240Vac
  • Max. Load Current: Resistive load: max. 4.3A,
    Capacitive/Inductive load: max. 1.7A
  • Standby Power Consumption: [specifications
    missing]

Product Usage Instructions

Function Introduction:

The Casambi Smart Relay Module is designed to control connected
light sources. It can be used with or without a neutral wire.

Wiring Instructions:

1) Wiring with neutral wire:

Wiring Diagram with Neutral Wire

For wiring with a neutral wire, connect the L terminal to the
live lead, N terminal to the neutral lead, L-out terminal to the
output terminal of the dimmer, and S terminal to the switch.

2) Wiring without neutral wire:

Wiring Diagram without Neutral Wire

For wiring without a neutral wire, follow the same connections
as above but without the neutral wire.

Accessories:

  1. Accessory 1: Wire clamp cover (sold separately)
  2. Accessory 2: Din rail bracket (sold separately)

Frequently Asked Questions (FAQ)

Q: What is the standby power consumption of the Casambi Smart
Relay Module?

A: The standby power consumption information is currently
unavailable in the provided text.

“`

Casambi Smart Relay Module
Important: Read All Instructions Prior to Installation Function introduction
42 mm

Wiring Diagram
Notes for the diagrams: L – terminal for live lead N – terminal for neutral lead L-out – output terminal of the dimmer (controlling connected light source) S – terminal for switch

1) Wiring with neutral wire

2): Wiring without neutral wire

L-out

S

L

N

L-out

S

L

N

L-out

S

L

N

38 mm

L-out

S

L

N

Accessory 1: Wire clamp cover. Need to purchase separately.

16 mm

Accessory 2: din rail bracket. Need to purchase separately.

Product Data
Input Voltage 100-240Vac

Output Voltage 100-240Vac

Max. Load Current
Resistive load: max. 4.3A, Capacitive/Inductive load: max. 1.7A

Standby Power Consumption
<=0.5W

Size(LxWxH) 42x38x16mm

· Casambi in wall smart relay module · Supports resistive loads, capacitive loads or inductive loads · 1 channel relay output, max. load up to 4.3A, 1 channel push button input · Input and Output with Screw Terminals, Safe and Reliable · Enables to control ON/OFF of connected light source · Typical mesh range is over 50 meters line of sight for indoor environment · The relay can be controlled by Casambi app, remotes, wall switches, kinetic switches, the push button input can be configured to control Casambi network wirelessly · Mini Size, Easy to be Installed into a standard size wall box

Safety & Warnings
· DO NOT install with power applied to device. · DO NOT expose the device to moisture.

S

S

Bypass

S

N

N

N

L

L

L

* When using the device without neutral wire, the smart relay requires at least 3W @ 240 VAC of power consumption to operate. If the connected light has a smaller power consumption, then Bypass is needed for the device to work.