STEP 1: Crestron Hub Driver Installation

  1. Find Rollease Acmeda ARC2 module in the Crestron Application
    Marketplace.
  2. Unzip folder and open the Rollease Acmeda ARC2 v1.0 Demo IP
    CP3.smw file in SIMPL Windows.
  3. Locate the Rollease Acmeda ARC2 v1.0 Command Processor IP
    symbol in the SIMPL Windows program and replace the current IP
    address on the Pulse_Hub_IP_Address parameter with the actual IP
    address of your hub.
  4. Comment out the entire Motors subfolder in the example
    program.
  5. Compile and load the example program to your Crestron
    processor.
  6. Open the Rollease Acmeda ARC2 v1.0 Demo XPanel.c3p file to open
    the XPanel simulator on your computer (install Adobe Air first if
    needed).
  7. Click Options > Host Settings in the XPanel menu and enter
    the IP address of your Crestron.

STEP 2: Motor Address Configuration

  1. Get the addresses for all desired motors.
  2. Uncomment the entire Motors subfolder in the example
    program.
  3. Enter the appropriate address in the Motor_Address parameter
    for each instance of the Rollease Acmeda ARC2 v1.0 Motor Control
    module in your program.
  4. Recompile and reload your program.

STEP 3: Additional Information

Refer to the help files included in the module package for
further details and capabilities of the module(s).

Common Mistakes:

Ensure correct IP addresses and motor addresses are entered to
avoid issues during setup.

Frequently Asked Questions:

For further assistance, contact your retailer or visit our
website at www.rolleaseacmeda.com.

QUICK START GUIDE AutomateTM Crestron
INTEGRATION SUPPORT
AUTOMATE PULSE HUB PRO OVERVIEW Elevate your Automate experience by seamlessly integrating Automate motorized shades into CRESTRON SYSTEM. The Automate Pulse PRO Hub offers a powerful integration with discrete shade control and two-way communication, providing realtime updates on shade position and battery levels. Featuring both Ethernet (CAT 5) and 2.4GHz wireless connectivity, the Pulse PRO Hub ensures smooth home automation integration through an easy-to-access RJ45 port located on the back of the hub. Each hub supports up to 30 shades, making it a versatile solution for any home automation setup.
GETTING STARTED: In order to integrate your motorized window treatments with Crestron, you will need to have: · Downloaded the free Automate Shades App via the Apple App Store (available under iPhone /iPad apps) or the Google Play
Store. · Purchased one or more Automate Pulse PRO depending on size of the space and additional repeaters if is required. · Integrated your motorized window treatments onto Automate Shades App.
INSTRUCTIONS INCLUDED: · Set up instructions for both the Automate Shades App & Automate Pulse Hub PRO. · Crestron Driver Installation Instructions · Crestron Driver Guide · Integration Diagram · Integration FAQ’s
rolleaseacmeda.com © 2025 Rollease Acmeda Group

CRESTRON HUB DRIVER INSTALLATION SECTION: 1. Find Rollease Acmeda ARC2 module in the Crestron Application Marketplace. 2. Unzip folder and open the Rollease Acmeda ARC2 v1.0 Demo IP CP3.smw file in SIMPL Windows.
STEP 1:
3. Locate the Rollease Acmeda ARC2 v1.0 Command Processor IP symbol in the SIMPL Windows program and replace the current IP address on the Pulse_Hub_IP_Address parameter with the actual IP address of your hub.
4. Comment out the entire “Motors” subfolder in the example program. 5. Compile and load the example program to your Crestron processor. 6. Open the Rollease Acmeda ARC2 v1.0 Demo XPanel.c3p file to open the XPanel simulator on your computer
(you may need to install Adobe Air first with the included CrestronXPanel installer files). 7. Once the XPanel opens, click Options Host Settings in the top menu and enter the IP address of your Crestron
processor in the Hostname/IP Address field and hit connect. This will connect your XPanel to your processor and allow for using the XPanel as a simulator in place of a physical touchpanel. 8. The module will automatically attempt to communicate with the hub when the program loads. Once communication is established with the hub, the Communicating indicator on the top right of the XPanel will illuminate. If it does, proceed to the next steps. If it does not, verify the IP address you entered in SIMPL Windows is correct and that the hub and Crestron processor are on the same network. 9. On the Command Processor tab in the XPanel, click the “Setup” button so it illuminates blue. 10. Using a remote or the Rollease Acmeda app, move each shade to initiate a response (in order to identify each). 11. The address of the last motor that moved/responded will automatically populate in the Motor Address field on the XPanel. Move each motor to identify each address.
rolleaseacmeda.com © 2019 Rollease Acmeda Group

STEP 2:
12. Once you have the address for all your desired motors, uncomment the entire “Motors” subfolder in the example program and enter in the appropriate address in the Motor_Address parameter for each instance of the Rollease Acmeda ARC2 v1.0 Motor Control module in your program (the example program has 5 motors. You may have more or less in your installation). Once the addresses have been entered, recompile and reload your program.
13. Refer to the help files included in the module package for further details and information regarding the capabilities of the module(s).
STEP 3:
rolleaseacmeda.com © 2019 Rollease Acmeda Group

Common Mistakes:
· Entering the wrong IP address in the “IP Address” configuration line. If you’re failing to discover devices double check this!
CRESTRON SMART HOME CONTROL SYSTEM CONNECTION:
rolleaseacmeda.com © 2019 Rollease Acmeda Group

FREQUENTLY ASKED QUESTIONS:
Q. No Pulse Hub PRO detected. A. Make sure that your Automate Pulse PRO is connected to the correct network and get an IP Address available and still communicating with the network using the Automate Shades App. Q. Shade limits are not set properly. A. Calibrate shade limits with your Rollease Acmeda remote before setting the appropriate open and close time within CRESTRON SYSTEM. Q. Shade is not moving at all. A. Make sure the selected Pulse Hub PRO is the correct Pulse Hub PRO for the shade to be controlled. Confirm the correct bindings are set in the CRESTRON System connections tab between the Pulse Hub PRO and Shade drivers. Q. I have multiple Pulse PRO Hubs, what do I do? A. Load two Automate Pulse Hub PRO drivers. After selecting “Retrieve Hubs” located in the driver actions tab, you will see different Automate Pulse Hubs PRO – select the desired one. Q. I don’t see any shade bindings in the Pulse Hub PRO driver? A. Select “Retrieve Shades” located in the driver actions tab. Q. How do I scan for available Automate Pulse PRO Hubs? A. Once the Automate Pulse Hub PRO is properly connected via the Ethernet cable or Wireless network, navigate to the Automate Pulse Hub Properties page within Composer. Select “Retrieve Hubs” located in the driver actions tab. Q. We get unexpected responses from the CRESTRON system, or “?” symbols A. Ensure that all connections using the ethernet port or Wi-Fi are working properly. The missed connection has been known to yield unwanted or unexpected results. SUPPORT RESOUCES:
For further assistance, contact your retailer, visit our website at www.rolleaseacmeda.com.
rolleaseacmeda.com © 2019 Rollease Acmeda Group

Documents / Resources

AUTOMATE Crestron Pulse PRO Hub [pdf] User Guide
Crestron Pulse PRO Hub, Pulse PRO Hub, PRO Hub

References

Leave a comment

Your email address will not be published. Required fields are marked *