FS N5570-48S6C 48-Port Ethernet Data Center Switch
Product Overview
The N5570-48S6C switch delivers rich, low-latency Layer 2/Layer 3 features and advanced EVPN-VXLAN capabilities. With 48 native 10G downlink ports and 6 40/100GbE uplink ports, it is ideal for leaf roles in data centers and data center interconnect (DCI) deployments.
Featuring L3 gateway functionality for seamless routing between virtualized and bare-metal servers, the switch is designed for extremely agile data centers that require support for overlay/underlay network architectures.
Figure 1 shows the FS N5570-48S6C Switch.
Figure 1: N5570-48S6C Switch
The N5570-48S6C is a compact 10GbE data center Leaf switch with the following features:
- 48 10GbE SFP+ Downlink Ports, Six 40/100GbE QSFP28 Uplink Ports
- Broadcom BCM56771 with 64GB (SSD) storage
- Up to 1.08 Tbps (unidirectional) L2 and L3 performance
- VXLAN support as an L2 or L3 gateway
- Advanced PicOS® features, such as Ethernet VPN-Virtual Extensible LAN (EVPN-VXLAN), MLAG, BGP, and EVPN multihoming.
Using breakout cables, the 100G port supports 40Gb and splits into 4×10Gb, as well as splitting into 4×25Gb.
PicOS®
- The high-performance N5570-48S6C switch runs PicOS®, a powerful and robust network operating system that supports all FS PicOS® network switches. Key PicOS® features that enhance the functionality and capabilities of the N5570-48S6C include:
- Commit, Review, and Rollback: Prevents network configuration errors and enables rapid recovery to a stable state in case of anomalies, ensuring configuration accuracy and business continuity.
- Virtual ASIC Technology: Implements a hardware abstraction layer, allowing support for multiple hardware platforms and chipsets with minimal modifications. This vendor-agnostic solution enables rapid iteration and updates.
- Modular Design: Allows independent component operation and updates, enhancing system flexibility and stability. This architecture enables seamless integration of new features and simplifies maintenance and troubleshooting.
- Linux Debian Architecture: One of the most innovative open network operating systems in the industry, featuring built-in automation tools for easy implementation, management, customization, and scalability.
- Automation and Programmability: PicOS® offers a rich set of standardized programmable interfaces and automation tools, including Ansible, OpenFlow, and NETCONF, enabling automated network configuration and improved operational efficiency.
Data Center Deployments
Data centers require high-speed, low-latency, and converged network solutions for storage and I/O to maximize the performance of physical servers, virtual servers, and storage. The N5570-48S6C switch addresses these needs in a compact 1U platform with low-latency, lossless, high-density 10GbE interfaces. Additionally, the N5570-48S6C offers EVPN-VXLAN L2 and L3 gateway support, making it an ideal solution for edge routing or centralized routing overlay deployments in data centers. It supports front-to-back airflow, suitable for cold-aisle containment where cool air enters from the front and exits to the hot aisle at the rear.
Data Center Server Access
At the Leaf layer, the N5570-48S6C switch provides 48 10GbE server access ports, supporting high-density virtualized server deployments within a single rack to meet the demands of VM-intensive workloads in cloud computing environments. By leveraging VXLAN encapsulation, the physical and logical networks are decoupled, allowing each tenant to achieve Layer 2 isolation through a unique VXLAN Network Identifier (VNI), enabling thousands of independent tenant services to run on the same physical network. With an EVPN-based BGP control plane, the switch enables automatic learning and synchronization of MAC/IP addresses. When a virtual machine migrates across
Leaf switches, EVPN dynamically update the forwarding path using Type 2 routes (MAC/IP routes), ensuring seamless business continuity. At the Spine layer, the N8550-64C switch provides 64 100GbE ports, supporting full-mesh ECMP (Equal-Cost Multi-Path) routing to ensure optimal traffic forwarding across Leaf switches, reducing migration latency.
Figure 2 shows the 10G/100G Spine-Leaf Fabric.
Figure 2: 10G/100G Spine-Leaf Fabric
Features and Benefits
- Built-in Broadcom Trident 3 Chip: Provides high-speed data transfer, low latency, and 1.08 Tbps throughput for superior stability and performance.
- VXLAN Overlays: The N5570-48S6C switch is capable of both L2 and L3 gateway services. Customers can deploy overlay networks to provide L2 adjacencies for applications over L3 fabrics. The overlay networks use VXLAN in the data plane and EVPN for programming the overlays.
- Ensuring Uninterrupted Services with MLAG: Two N5570-48S6C switches can operate as independent devices with separate control planes while achieving redundancy and load balancing by enabling link aggregation on connected devices and using STP to eliminate loop risks. This enhances network bandwidth, improves reliability and availability, and ensures the seamless operation of critical services.
- Unified Operating System and Management Platform: Unified PicOS® and AmpCon-DC management platform, automates the entire network lifecycle to simplify design and deployment.
- Free Virtual Machine (VM): PicOS®-V is a Virtual Machine designed to help customers become familiar with the network functionalities and performance of PicOS®, without the need to wait for switching hardware.
Ampcon-DC Management Platform
The FS AmpCon-DC management platform ensures fast, accurate, and consistent delivery of the changes needed for data center services. It also leverages built-in assurance and analytics features to quickly resolve Day-2 operational issues.
- Fabric Management: AmpCon-DC management platform provides full Day 0 through Day 2+ lifecycle management capabilities for IP/EVPN fabrics with closed-loop assurance in the data center
Telemetry for Real-time Network Monitoring: Optimizes network performance through continuous data insights. - Topology Auto-discover for Visual Management: Enhances efficiency in network management and operations.
- Overlay-based Auto Configuration*: Centralized configuration is automatically issued to overlay networks (such as VXLAN), increasing configuration efficiency by reducing command complexity, manual errors, and the time required to understand overlay-specific settings.
- Underlay-based Auto Configuration: Centralized configuration is automatically issued to the underlay network infrastructure (such as IP routing and interfaces), increasing configuration efficiency by reducing manual errors and the time required to learn traditional underlay configuration commands.
- Lossless Network Automation*: The overall network can be monitored and optimized, which improves business efficiency and the operation and maintenance efficiency of network administrators.
- Lossless Network O&M Monitoring: If a link failure occurs in the network, the chip can achieve sub-millisecond convergence, minimizing the impact on user services.
Notice: Expected to be available in Q2 2025
N5570-48S6C Switch Specifications
Tables 1 through 4 show the FS N5570-48S6C switch hardware specifications.
Table 1: Interface options
P/N | N5570-48S6C |
Console port | 1 |
Management port | 2 × RJ-45 port |
USB port | 1 |
1GbE SFP | 48 |
10GbE SFP+ | 48
56 (with breakout cable) |
25GbE SFP28 | 8 (with breakout cable) |
40GbE QSFP+ | 6 |
100GbE QSFP28 | 6 |
NOTE: Due to hardware limitations, only ports xe-1/1/1 and xe-1/1/4 support being split into four 25G Ethernet interfaces; other ports are not supported to be split.
Table 2: Power supplies and fans
P/N | N5570-48S6C |
Power supply | Dual 1+1 redundant power supplies (AC) |
Fan number | 5x Hot-swappable Fans (4+1 Redundancy) |
Airflow | Front-Rear |
Power consumption | Max power draw: 356W |
Power max rating | 400W |
Input-voltage range and frequency | 100-240VAC, 50-60Hz |
Input current | 6-3A |
Table 3: Performance specifications
P/N | N5570-48S6C |
Switching capacity | 1.08/2.16Tbps (uni/bidirectional) |
Forwarding rate | 964.28 Mpps |
Switch chip | Broadcom BCM56771 Trident 3 |
CPU | Intel Atom® C3558 2.2GHz 4-Core x86 processor |
DRAM | 2x 8 GB SO-DIMM |
Flash memory | 64GB |
Packet buffer | 32MB |
MAC address table size | 32K |
VLAN ID | 4K |
IPv4 routes | 32K |
IPv6 routes | 12K |
Table 4: Product specifications
P/N | N5570-48S6C |
Environmental | |
Operating temperature | 32°F to 104°F (0°C to 40°C) |
Storage temperature | 40°F to 158°F (-40°C to 70°C) |
Operating humidity | 5% to 95% (Non-condensing) |
Storage humidity | 5% to 95% (Non-condensing) |
Temperature alarm | supported |
Physical specifications | |
Weight | 21.14 lbs (9.59kg) |
Dimensions (H x W x D) | 1.73″x17.42″x18.63″ (43.95×442.5×473.3mm) |
Rack units (RU) | 1 RU |
Electrical | |
Voltage (auto ranging) | 100-240VAC |
Frequency | 50-60Hz |
Current | 3A Max |
Power rating (maximum consumption) |
400W |
Software Features Supported
Table 5 lists the software spotlights for the FS N5570-48S6C switch. Table 5: Software spotlights
Functionality | Description |
System Management |
• Hardware management of the system’s FAN and PSU
• Syslog management • Boot diagnose • Recover the default configuration and password • Zero Touch Provisioning (ZTP) • System file management • User management • Support to configure login methods • System time management: manual method, NTP • Domain Name System (DNS) |
Ethernet Ports Management Configuration | |
• Enable or disable the Ethernet port | |
• Configuring port speed | |
• MTU | |
• Flow control | |
• Flow statistics | |
• Port breakout | |
• Routed Interface and Sub-interface | |
• Layer 3 VLAN Interface | |
• Storm Control | |
• Local loopback | |
• Backup port | |
• Link Fault Signaling (LFS) | |
• Forwarding Error Correction (FEC) | |
• Time Domain Reflectometry (TDR) | |
• Clock and Data Recovery (CDR) | |
MAC configuration | |
• Static MAC entries and Dynamic MAC Address Learning | |
Static Link Aggregation (LAG) Configuration | |
Layer 2 Switching Configuration | • Static LAG
• Dynamic LAG (LACP) |
• Load balancing | |
• Resilient LAG Hashing | |
• Symmetric Hash for LAG | |
MLAG | |
• Basic MLAG | |
• Support IPV6 | |
• MLAG Active-Active | |
• Load balancing | |
• MLAG DHCP Snooping | |
• MLAG DHCP relay | |
• MLAG IGMP snooping | |
• MLAG VxLAN | |
• MLAG PVST+ | |
Port access mode | |
• ACCESS | |
• Trunk | |
• Hybrid | |
VLAN | |
• Port-based VLAN | |
• MAC Trace |
• MAC-based VLAN VLAN mapping • QinQ VLAN registration • GVRP • MVRP Private VLAN Voice VLAN Spanning Tree Protocol • STP • RSTP • MSTP • PVST+ • BPDU Filter • BPDU Root Guard • BPDU TCN-Guard • BPDU-Guard • Edge port • Manual forwarding BPDU Tunneling • Layer 2 protocol messages, such as CDP, LLDP, LACP, and STP, are supported and can be transmitted through BPDU tunnels Ethernet Ring Protection Switching (ERPS) • ERPSv1ERPSv2 Unidirectional Link Detection (UDLD) Loopback Detection |
IPv4 Basic Configuration | |
ARP | |
• Static ARP | |
• Dynamic ARP | |
• ARP Proxy | |
DHCP | |
• DHCP server and DHCP client | |
• DHCP relay and DHCP relay option 82 | |
• DHCPv6 Relay | |
• DHCP snooping | |
• DHCP snooping trust-port | |
• DHCP snooping option 822 | |
IP Service Configuration Guide |
• DHCPv6 snooping
Equal-Cost Multipath Routing (ECMP) • Max path |
• Load balancing | |
• Symmetric Randomized Load Balance | |
• Round-Robin Load Balance | |
• Resilient Load Balancing | |
VRF | |
• Base VRF | |
• Management of VRF and VRF Route Leaking | |
IPv6 | |
• IPv6 DHCP Relay | |
• IPv6 NDP | |
• IPv6 ECMP | |
• Path MTU Discovery |
Multicast Configuration |
IGMP
• IGMPv2 query • IGMPv3 query PIM • PIM SM • Static Dynamic RP • PIM-SSM • PIM over GRE Tunnel MSDP • PIM-SM Inter-domain Multicast Using MSDP • Anycast RP Multicast routing • Multicast routing and forwarding Multicast VLAN • Multicast VLAN Registration (MVR) IGMP Snooping • IGMPv2 snooping • IGMPv3 snooping • mrouter port • static group • unregistered flood |
VPN | Generic Routing Encapsulation Protocol (GRE) |
VXLAN |
VXLAN EVPN
• BGP EVPN |
High Availability |
BFD
• Static BFD • Dynamic BFD • Single-Hop BFD • Multi-Hop BFD • BFD for BGP • BFD for OSPF • BFD for PIM-SM Uplink Failure Detection (UFD) • Uplink Failure Detection Priority Flow Control (PFC) Virtual Router Redundancy Protocol (VRRP) • VRRP Active-Standby • VRRP Active-Active (load-balance) • VRRPv2 • VRRPv3 • preempt mode • priority • authentication • accept mode EFM OAM • OAM link discovery • Remote loopback |
Lossless Network |
PFC, Priority Flow Control
• Enabling PFC • PFC Buffer PFC Watchdog • Enable PFC watchdog • detect-interval • restore-action • restore-interval PFC Deadlock Prevention • PFC uplink port groupModify the queue priority and DSCP ECN, Explicit Congestion Notification • Enable WRED • Set the maximum and minimum thresholds • Set drop probability • Enable ECN Easy ECN • Throughput-First mode • Latency-First mode DLB, Dynamic Load Balancing • Normal ModeOptimal ModeAssigned Mode |
Security |
AAA
• Radius Authentication • Radius Authorization • Radius Accounting • TACACS+ Authentication • TACACS+ Authorization • TACACS+ Accounting • Console Login • OUT-band/IN-BAND Login • Local Authentication • local authentication fallback NAC • 802.1X • MAC authentication • CWA authentication • Web authentication • Host Mode • Server Fail VLAN • Block VLAN • Dynamic VLAN • Fallback to WEB • EAP Packet Exchange • Redirect URL • Change of Authorization (CoA) • Downloadable ACL • Dynamic ACL • session-timeout • Re-authentication ACL Match field: • destination-address-ipv4 • destination-address-ipv6 • destination-mac-address • destination-port • ether-type • first-fragment • ip • is-fragment • protocol • source-address-ipv4 • source-address-ipv6 |
• source-mac-address • source-port • time-range • vlan • ACL-based Traffic Policer • ACL-based QoS • ACL-based remark Port Security • Enable or disable port security DAI • Trust Port • ARP Packets Validity Checking • User Legitimacy Checking • Dynamic ARP Inspection • ARP Inspection Access List CoPP • System pre-defined control plane protocols • Change the pre-defined CoPP policies • System custom-defined control plane protocols IPv4SG (IPv4 Source Guard) • IPv4 Source Guard IPv6SG (IPv6 Source Guard) • IPv6 Source Guard DHCPv6 Guard Neighbor Discovery Inspection • Enable ND inspection on a VLANValidate source-mac Neighbor Discovery Snooping • ND Snooping |
|
QoS Service Configuration |
Queue scheduler
• Queue scheduler: SP WRR WFQ Traffic policing • Traffic policing: • guaranteed-rate • max-rate • Traffic classifier Congestion management and avoidance • Congestion management: WRED • Congestion avoidance: ECN |
SNMP | |
• SNMP v2 | |
• SNMP v3 | |
• SNMP Access control | |
• SNMP authentication | |
• SNMP privacy | |
• SNMP Trap | |
• SNMP VRF | |
RESTCONF | |
Remote Network Monitoring (RMON) | |
• Ethernet statistics function (etherStatsTable in RMON MIB) | |
• History statistics function (etherHistoryTable in RMON MIB) | |
• Event definition function (eventTable and logTable in RMON MIB) | |
• Alarm threshold setting function (alarmTable in RMON MIB) | |
NETCONF | |
LLDP | |
• LLDP Mode | |
• Selecting Optional TLVs | |
• LLDP med | |
Mirror Configuration | |
Network Management and Monitoring | • Local port mirror
• ERSPAN |
• Base ACL ERSPAN | |
Switch the Environment monitor. | |
• boot-messages | |
• connections | |
• cpu-usage | |
• fan | |
• hwinfo | |
• memory-usage | |
• processes | |
• rollback | |
• rpsu | |
• serial-number | |
• temperature | |
Packet Capture | |
• tcpdump | |
Telemetry Protocol | |
SDN | |
• Openflow | |
sFlow | |
• collector UDP port |
• source address • header length • sampling rate |
Standards Compliance
Table 6 lists the standards compliance for the FS N5570-48S6C switch.
Table 6: Standards compliance
Category | Description |
IEEE Standard |
IEEE 802.1 IEEE 802.1AB IEEE 802.1ad IEEE 802.1ax IEEE 802.1D IEEE 802.1p IEEE 802.1Q IEEE 802.1Qbb IEEE 802.1w IEEE 802.3x |
Supported RFCs |
RFC 768 UDP
RFC 791 IP RFC 792 ICMP RFC 793 TCP RFC 826 ARP RFC 854 Telnet client and server, RFC 894 IP over Ethernet RFC 1058 RIP RFC 1112 IP Multicast Host Extensions RFC 1142 OSI IS-IS Intra-domain Routing Protocol RFC 1492 TACACS RFC 1519 Classless Interdomain Routing (CIDR) RFC 1534 DHCP-BOOTP Interoperation RFC 1745 BGP4/IDRP for IP—OSPF Interaction RFC 1771 BGP-4 RFC 1812 Requirements for IP Version 4 Routers, RFC 1997 BGP Communities Attribute RFC 2080 RIP for IPv6, RFC 2131 DHCP RFC 2132 DHCP Options & BOOTP Extensions RFC 2138 RADIUS Authentication RFC 2139 RADIUS Accounting RFC 2154 OSPF with Digital Signatures (Password, MD-5) RFC 2236 IGMP v2 RFC 2328 OSPF v2 RFC 2338 VRRP RFC 2370 OSPF Opaque LSA Option RFC 2385 Protection of BGP Sessions via the TCP MD5 Signature Option, RFC 2453 RIP v2 RFC 3031 MPLS Architecture RFC 3032 MPLS Label Stack Encoding RFC 3034 Label Switching over Frame Relay RFC 3036 LDP Specification RFC 3037 LDP RFC 3046 DHCP Relay Agent Info Option, RFC 3101 NSSA Option RFC 3215 LDP State Machine RFC 3376 IGMP v3 RFC 3446 Anycast RP Mechanism (PIM+MSDP) RFC 3569 SSM Overview RFC 3618 MSDP RFC 4541 IGMP/MLD Snooping Guidelines RFC 4601 PIM-SM(Rescinded) RFC 4607 IP Source-Specific Multicast RFC 5036 LDP Specification (Updated) |
Warranty, Service, and Support THE
FS N5570-48S6C switch has a 5-year limited warranty against defects in materials or workmanship. For more information on the FS Returns & Refunds policy, visit https://www.fs.com/policies/warranty.html or
- https://www.fs.com/policies/day_return_policy.html
- FS provides a personal account manager, free professional technical support, and 24/7 live customer service to each customer.
- Professional Lab: Test each product with the latest and advanced networking equipment.
- Free Technical Support: Provide free & tailored solutions and services for your businesses.
- 80% Same-day Shipping: Immediate shipping for in-stock items.
- Fast Response: Direct and immediate assistance from an expert.
For more information, visit https://www.fs.com/service/fs_support.html
Ordering Information
Table 7 provides the ordering information for the N5570-48S6C switch and the AmpCon-DC management platform.
Table 7: Ordering information
Product | Description |
Switch Hardware | |
N5570-48S6C, 48-Port Ethernet Data Center Switch, 48 x 10Gb SFP+, with 6 x 100Gb QSFP28 Uplinks, PicOS®, Broadcom Trident 3 Chip | |
AmpCon-DC Management Platform | |
AmpCon-DC Management Platform for PicOS® Data Center Switches with 1-Year Service Bundle, Support Remote Deployment and Automate Network Management (Per Device) | |
AmpCon-DC Management Platform for PicOS® Data Center Switches with 3 Years Service Bundle, Support Remote Deployment and Automate Network Management (Per Device) | |
AmpCon-DC Management Platform for PicOS® Data Center Switches with 5 Years Service Bundle, Support Remote Deployment and Automate Network Management (Per Device) |
- Delaware, United States
- Address:Delaware: 380 Centerpoint Blvd, New Castle, DE 19720, United States
- Email:US@fs.com
- Tel:+1 888-468-9910
- Germany
- Address:Röntgenstraße 18, 85757 Karlsfeld, Germany
- Email:DE@fs.com
- Tel:+49 (0) 8131 377 3008
- Australia
- Address:57-59 Edison Rd, Dandenong South, VIC 3175, Australia
- Email:AU@fs.com
- Tel:+61 3 5909 9990
- Japan
- Address: J S Progress Building 5F, 4-1-23, Heiwajima, Ota Ku, Tokyo, 143-0006, Japan
- Email:JP@fs.com
- Tel:+81-3-6897-9438
- California, United States
- Address:California: 15241 Don Julian Rd, City of Industry, CA 91745, United States
- Email:US@fs.com
- Tel:+1 888-468-9910
- United Kingdom
- Address: Unit 8, Urban Express Park, Union Way, Aston, Birmingham B6 7FH, United Kingdom Email:UK@fs.com
- Tel:+44 (0) 121 726 4775
- Singapore
- Address:7002 ANG MO KIO AVENUE 5 #05-02 Singapore 569914
- Email:SG@fs.com
- Tel:+65 31381992
FS has several offices around the world. Addresses, phone numbers are listed on the FS Website at https://www.fs.com/contact_us.html. FS and FS logo are trademarks or registered trademarks of FS in the U.S. and other countries.
Documents / Resources
![]() |
FS N5570-48S6C 48-Port Ethernet Data Center Switch [pdf] Instruction Manual N5570-48S6C 48-Port Ethernet Data Center Switch, N5570-48S6C, 48-Port Ethernet Data Center Switch, Ethernet Data Center Switch, Data Center Switch, Center Switch |