Nhanganyaya
This manual provides detailed instructions for the safe installation, operation, and maintenance of your RAB Lighting LED Bullet Flood 2x12W Adjustable Dual Heads fixture. Please read this manual thoroughly before installation and retain it for future reference.
Ruzivo Rwakakosha Chekuchengetedza
- YAMBIRO: Ngozi yemagetsi. Bvisa magetsi pafiyuzi kana dunhu rinotyora usati waisa kana kusevhisi.
- Kuisa kunofanira kuitwa nenyanzvi yemagetsi inokwanisa zvichienderana nemutemo wemagetsi wenyika nemunharaunda.
- Usaise pedyo nezvinhu zvinopisa.
- Ita shuwa kuti chigadziriso chakanyatsogadziriswa.
- Usaedza kugadzirisa chigadzirwa.
- Suitable for wet locations, wall mount only.
Package Zviri mukati
Tarisa kuti zvese zviriko zviripo usati watanga kuisa:
- RAB Lighting LED Bullet Flood 2x12W Fixture (1)
- Mounting Hardware (screws, wire nuts) (1 set)
- Bhuku reMirayiridzo (1)

Image: RAB Lighting LED Bullet Flood 2x12W Adjustable Dual Heads fixture in white finish. This image shows the two adjustable LED floodlight heads attached to a central mounting base.
Zvinotsanangurwa
| Feature | Detail |
|---|---|
| Model Number | SMSBULLET2X12NA |
| Simba Source | Corded Electric, 120 Volts |
| Wattage | 24 Watts (2x12W LED) |
| Light Output | 1664 Lumens |
| Rudzi Tembiricha | 5000 Kelvin (Muchena Muchena) |
| Chiedza Chinyorwa Type | LED |
| Material | Simbi (Chigadziko), Plastiki (Mumvuri) |
| Finish Type | Chena |
| Installation Type | Wall-Mounted |
| Indoor / Outdoor Kushandiswa | Outdoor (Suitable for wet locations) |
| Dimensions | 14.3 x 8.2 x 7.8 inches |
| Kurema | 4.99 makirogiramu |
Setup uye Installation
Zvishandiso Zvinodiwa: Screwdriver, Wire Strippers, Pliers, Electrical Tape, Voltage Tester, Ladder (if necessary).
- Dzima Simba: Locate the circuit breaker or fuse box controlling the power to the installation area. Turn off the power completely before proceeding. Verify power is off using a voltage muedzo.
- Gadzirira Mounting Surface: Ensure the mounting surface is clean, dry, and structurally sound. This fixture is designed for wall mounting only.
- Mount the Fixture: Secure the fixture's mounting base to the wall using the provided mounting hardware. Ensure a tight and stable connection.
- Wire Connections: Connect the fixture's wires to the corresponding household electrical wires.
- Batanidza iyo nhema fixture waya kune nhema (hot) supply wire.
- Batanidza iyo chena fixture waya kune chena (neutral) kugovera waya.
- Batanidza iyo girinhi or bare copper fixture wire to the girinhi or bare copper (ground) supply wire.
Chengetedza zvese zvinongedzo newaya nzungu uye tepi yemagetsi.
- Seal Connections: Ensure all wire connections are properly insulated and tucked into the junction box.
- Final Assembly: Attach the fixture body to the mounting base, ensuring it is securely fastened.
- Dzosera Simba: Once installation is complete and all connections are secure, restore power at the circuit breaker or fuse box.
Operating Instruction
The RAB Lighting LED Bullet Floodlight is designed for straightforward operation.
- Batidza/Kudzima: The fixture is controlled by the wall switch or external control device connected to its power supply.
- Kugadzirisa Misoro Yechiedza: The two LED floodlight heads are independently adjustable. Loosen the adjustment screws on each head, position the light beam as desired, and then securely tighten the screws to maintain the position.
- Light Output: The fixture provides 1664 lumens of 5000K cool white light.
Maintenance
Kugadziriswa nguva dzose kunoita kuti chiedza chemwenje chishande zvakanaka uye chigare kwenguva refu.
- Kuchenesa: Nguva nenguva chenesa kunze kwechigadzirwa netsvina yakapfava, damp jira. Usashandise abrasive cleaners kana solvents. Ita shuwa kuti magetsi adzima usati wachenesa.
- Kuongorora: Annually inspect the fixture for any signs of damage, loose connections, or wear. Address any issues promptly.
- MaODs: The integrated LED light sources are designed for long life (100,000 hours) and are not user-replaceable.
Kugadzirisa matambudziko
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| Chiedza hachibatidze. | Hapana simba kune fixture. Loose wiring connection. Faulty switch. | Tarisa wedunhu breaker/fuse. Wona kuti kubatanidza kwewaya kwese kwakachengeteka (ona kuti magetsi adzimwa kutanga). Edza kana kutsiva switch. |
| Chiedza chinopenya. | Loose wiring connection. Isingaenderane dimmer switch (kana iripo). | Tarisa uye chengetedza zvese zvakabatanidzwa wiring. This fixture is not specified as dimmable; ensure it's connected to a standard ON/OFF switch. |
| Yakaderedzwa chiedza kubuda. | Dirt or debris on lens. | Clean the diffusion lens with a soft, damp jira. |
If issues persist after troubleshooting, contact RAB Lighting customer support.
Warranty Information
This RAB Lighting product comes with a Limited Warranty. For specific terms, conditions, and duration of the warranty, please refer to the official RAB Lighting website or contact their customer service. Retain your proof of purchase for warranty claims.
Mutengi Support
For technical assistance, replacement parts, or warranty inquiries, please contact RAB Lighting directly:
- Websaiti: www.rablighting.com
- Runhare: Refer to the RAB Lighting websaiti yeazvino manhamba ekubata.