Ecovector® II Smart Low Level
Education | Healthcare | Places of worship | Leisure and sport | Office | Hospitality | Retail | Showroom | Industrial | Residential
Ecovector II Smart Low Level
Ecovector II Low Level fan convectors provide warmth from a low level upwards and are more energy efficient and effective than radiators
The Ecovector II can heat up a room more quickly than radiators, thereby reducing the amount of time your boiler or heat pump is running – making it extremely efficient and cost effective
Compatible with most types of wet central heating systems, functioning equally efficiently with conventional boilers, biomass technology or ground or air source heat pumps
Ideal for new and existing developments, due to ease of installation, the Ecovector is available in a range of models to suit varying room sizes and heat output requirements
Product information
Finish
Front casing: zinc-coated steel.
Polyester powder-coated RAL 9016.
Installation
This heating appliance is intended for mounting on a wall at low level via the chassis mounting holes. The minimum recommended installation height is 100mm from the floor. There is no clearance required on either side of the heater.
Ecovector II is designed for use on standard two-pipe pumped central heating systems where the system hot water is generated from either a boiler or renewable sources.
Commissioning
Check water is hot enough to activate the low temperature cut-out thermostat when in heating mode. Check functionality of thermostat and link to Hub if required.
Control
Built-in smart control with manual/auto fan speed, time and temperature control.
Capable of being used with App when a Hub is used.
Specification
To specify state:
Low level hydronic fan convector in white.
As Smith’s Ecovector ll Smart Low Level LL640/LL1030/LL1390.
Dimensions
Ordering Guide
Model | Packed Wt (kg) | Product Codes |
ECOVECTOR II SMART LL 640 | 14 | HPEV50022 |
ECOVECTOR II SMART LL 1030 | 19 | HPEV50023 |
ECOVECTOR II SMART LL 1390 | 26 | HPEV50024 |
Technical Data
Heat output
Model |
Heat Output at 80° | Heat Output at 75° | Heat Output at 70° | Heat Output at 65° | Heat Output at 60° | ||||||||||
Low (kW) | Medium (kW) | High (kW) |
Low (kW) | Medium (kW) | High (kW) | Low (kW) | Medium (kW) | High (kW) | Low (kW) |
Medium (kW) | High (kW) | Low (kW) |
Medium (kW) |
High (kW) | |
ECOVECTOR II SMART LL 640 | 0.86 | 1.21 | 1.45 | 0.78 | 1.11 | 1.32 | 0.69 | 1.00 | 1.19 | 0.58 | 0.91 | 1.07 | 0.47 | 0.81 | 0.94 |
ECOVECTOR II SMART LL 1030 | 1.73 | 2.47 | 2.82 | 1.62 | 2.24 | 2.56 | 1.50 | 2.01 | 2.29 | 1.36 | 1.86 | 2.08 | 1.22 | 1.7 | 1.86 |
ECOVECTOR II SMART LL 1390 | 2.44 | 3.48 | 4.00 | 2.22 | 3.19 | 3.67 | 2.00 | 2.90 | 3.34 | 1.82 | 2.59 | 3.02 | 1.63 | 2.27 | 2.7 |
Model |
Heat Output at 55° | Heat Output at 50° | Heat Output at 45° | Heat Output at 40° | ||||||||
Low (kW) | Medium (kW) | High (kW) | Low (kW) | Medium (kW) | High (kW) | Low (kW) | Medium (kW) | High (kW) | Low (kW) | Medium (kW) | High (kW) | |
ECOVECTOR II SMART LL 640 | 0.45 | 0.71 | 0.82 | 0.43 | 0.61 | 0.70 | 0.37 | 0.51 | 0.59 | 0.30 | 0.41 | 0.47 |
ECOVECTOR II SMART LL 1030 | 1.06 | 1.48 | 1.66 | 0.9 | 1.26 | 1.46 | 0.76 | 1.06 | 1.22 | 0.62 | 0.86 | 0.97 |
ECOVECTOR II SMART LL 1390 | 1.45 | 2.02 | 2.37 | 1.27 | 1.76 | 2.03 | 1.05 | 1.47 | 1.72 | 0.82 | 1.17 | 1.41 |
Model | Flow & return connections | Mains cable |
Fused spur |
Total Power Consumption |
Max Current Draw Amps | Water Capacity (Litres) | Sound Levels | Casting colour |
Fan- only | ||||
Low (Watts) (Watts) |
Mediu | High (Watts) |
Low (dBA) | Medium (dBA) | High (dBA) | ||||||||
ECOVECTOR II SMART LL 640 | 15mm | 1.5m | 3A | 18 | 25 | 31 | 0.25 | 0.29 | 26 | 29 | 33 | white | yes |
ECOVECTOR II SMART LL 1030 | 15mm | 1.5m | 3A | 25 | 37 | 44 | 0.45 | 0.58 | 27 | 30 | 34 | white | yes |
ECOVECTOR II SMART LL 1390 | 15mm | 1.5m | 3A | 36 | 54 | 67 | 0.60 | 0.83 | 28 | 32 | 36 | white | yes |
Heat outputs tested in accordance with BS4856 with a fixed flow rate of 340L/H (75GPH) and an entering air temperature of 18°C. Sound levels measured at 1.5m.
As part our commitment to continuous improvement Smith’s Environmental Products may change the specifications of its products without prior notification or public announcement. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All dimensions are in mm unless otherwise stated. Please visit our website for the most up to date information.
Issue 003 | January 2025 +44 (0) 1245 324 900 | sales@smithsep.co.uk | SmithsEP.co.uk
Documents / Resources
![]() |
Smith s Ecovector II Smart Low Level [pdf] Instruction Manual Ecovector II Smart Low Level, Ecovector II, Smart Low Level, Low Level |