SRP620 Series
Quick Start Guide

Welcome to the SRP Series

SRP series ruggedized outdoor router provides 5G NR service in a ruggedized form factor. With an operating temperature range of -40 ℃ ~ 70 ℃
endurance, they offer industrial-grade environmental qualifications while providing higher speed data services for video and other bandwidth-intensive applications.  SRP series industrial router has very strong anti-vibration ability and it is qualified for extreme industrial environments and ideally suited for rail,  transportation, mining, oil and gas, manufacturing, and other outdoor applications.
With the diverse self-developed 5G NR embedded modules integrated, SRP series industrial router can support multi-band for Private 5G NR, even support uncommon frequencies. SRP series industrial router can provide accurate real-time location information.
This document will serve as a quick start guide for the SRP series ruggedized outdoor router. In this document, the SRP series ruggedized outdoor router will be replaced by the router.

Device Architecture

Smawave Technology SRP620 5G IP67 Ruggedized Router

  1. Power port
  2. LAN1/WAN port
  3. RS232 and DIDO port
  4. LAN2 port
  5. RS485 port
  6. LED interface
  7. SIM interface
  8. Ground screws
  9. 5G NR antenna interface
  10. WIFI antenna interface

Note1 The reset button is beside the SIM interface, if the press  1s, the router will restart; If pressed for 10s, the router will reset to factory defaults.
Note2  There are two white ground screws also at the behind of the device.

RS232/485 Cable Definition

RS232/485 cable definition
Smawave Technology SRP620 5G IP67 Ruggedized Router - cable Number Colors RS485 RS232+DIDO
1 Orange&white NC DO2
2 Orange NC DI2
3 Green&white RS_GND DO1
4 Blue RS_GND DI1
5 Blue&white RS_GND RS_GND
6 Green RS_GND RS_GND
7 Brown&white RS485_B RS232_TX
8 Brown RS485_A RS232_RX

LAN/WAN Cable Definition

LAN/WAN cable definition
Smawave Technology SRP620 5G IP67 Ruggedized Router - cable definition Number Colors LAN/WAN
1 Orange&white MDI0+/RJ45-1
2 Orange MDI0-/RJ45-2
3 Green&white MDI1+/RJ45-3
4 Blue MDI2+/RJ45-4
5 Blue&white MDI2-/RJ45-5
6 Green MDI1-/RJ45-6
7 Brown&white MDI3+/RJ45-7
8 Brown MDI3-/RJ45-8

Power Cable Definition

Power cable definition
Smawave Technology SRP620 5G IP67 Ruggedized Router - Power cable Number Colors PWR
1 Red PWR_Positive
2 Black PWR_GND
3 NC NC
4 NC NC

Working Environment

Operating Temperature -40℃ ~ 70℃
Storage Temperature -40℃ ~ 85℃
Humidity 5% ~ 95%
Power Supply 9 ~ 36VDC
Power Consumption <20W
Water and Dustproof IP67

Packing List

Items Accessories Qty
1 A-Code cable to RJ45 jack ADC2

(Ethernet cable)

1
2 A-Code 8-Pin cable ADB1 (Data cable) 1
3 A-Code 4-Pin cable M12A (Power cable) 1
4 Mounting bolt 4
5 Grounding cable 1
6 Protective cap (TNC) 6
7 Protective cap (M12) 5

Hardware Configuration

Step1 Use a cross screwdriver to remove the SIM card cover.
Install SIM Cards 
Step2 Slide the SIM cards into the SIM slots until they click into place. By default, the SIM card in slot 1 (the upper slot) is the Primary SIM card. When the SRP router is powered on or rebooted, it automatically connects to the network associated with the Primary SIM card.
Step3 Re-attach the cover.
Smawave Technology SRP620 5G IP67 Ruggedized Router - coverConnect and Turn on the Router

 warning Please connect the protecting ground cable as the first step, connect 9-36 VDC power cable as the last step.

Smawave Technology SRP620 5G IP67 Ruggedized Router - Connect

Connect to the Network
When the router is powered on, a green PWR LED may occur.
This indicates that the power input is good. Once the router’s radio module is configured for the SIM card, it begins the activation/provisioning process and attempts to
connect to the mobile network. This process typically takes several minutes. A successful connection is indicated by a solid green NET LED. And the strength of the RF signal can be indicated by the Signal LEDs in different quantities.

Indicator Status Description
 

PWR

Green Power on
Off No power supply
 

 

NET

Green Registered to network
Off Not register to the network
Blinking Searching network
 

 

 

RSSI

Green Signal strong
Yellow Signal good
Red Signal weak
Off No signal
Red Blinking No SIM or SIM error

Software Configuration

Log in to the Web Management Page
Step1 Launch the web browser, enter http://192.168.1.1 in the address bar, and press Enter. Smawave Technology SRP620 5G IP67 Ruggedized Router - username

Step2 Enter the username and password and click Login.
Step3 After the password is verified, you can log in to the web management page.
Smawave Technology SRP620 5G IP67 Ruggedized Router - password

The default username and password are both admins. If you want to view or configure the router, you should use the super account to log in to the web management page. The default super username is super admin, and the password is admin.

Radio Settings

Step1 Choose Network > Radio Settings.
Step2 On the Radio Settings page, you can set the configura-  notion of 5G NR network.
In the 5G Status list, you can view the 5G NR status,
Step3 such as Frequency, RSSI, RSRP, RSRQ, CINR, SINR, Cell ID and etc.

Device Information
NetworkUnder
WAN Settings
DNS Settings
APN Management
Radio Settings
Scan Mode
PIN Management
Dual SIM
SIM-Lock
LAN Settings
Static Route
Radio On/Ott
Security SettingsSmawave Technology SRP620 5G IP67 Ruggedized Router - fig15
VPN
IPv6Smawave Technology SRP620 5G IP67 Ruggedized Router - fig15
SystemSmawave Technology SRP620 5G IP67 Ruggedized Router - fig15

CINCO –dB
CINR1 –dB
TX Power –dBm
PCI 385
Cell ID  16
MCC 460
MNC  00

5G Status

DL Frequency 2524.950MHz
UL Frequency 2524.950MHz
Band 41
Bandwidth 20MHz
RSRPO -89dBm
RSRP1 -89dBm
RSSI -56dBm
RSRQ -13dB
SINR 16dB
PCI 3
Cell ID —
MCC 460
MNC 00

WLAN Settings
Step1 Choose Settings → Wi-Fi → WLAN Settings.
Step2 In the General Settings list, set Wi-Fi Enable or not Enable.
Step3 In the SSID Profile list, change the SSID, such as”5G NR-Router”.
Step4  To ensure data security, it is recommended that you change the Wi-Fi password.
Step5 Click Submit to save the settings.
WLAN Settings
General Settings

Band Smawave Technology SRP620 5G IP67 Ruggedized Router - fig.
WLAN Smawave Technology SRP620 5G IP67 Ruggedized Router - fig 1
Mode Smawave Technology SRP620 5G IP67 Ruggedized Router - fig 3.
Bandwidth Smawave Technology SRP620 5G IP67 Ruggedized Router - fig 4.
Channel Smawave Technology SRP620 5G IP67 Ruggedized Router - fig 5
TX Power Smawave Technology SRP620 5G IP67 Ruggedized Router - fig 7

Configuration

SSID ? Smawave Technology SRP620 5G IP67 Ruggedized Router - fig9
Maximum number of devices Smawave Technology SRP620 5G IP67 Ruggedized Router - fig 10
Hide SSID broadcast Smawave Technology SRP620 5G IP67 Ruggedized Router - fig 11
AP isolation                                                         Smawave Technology SRP620 5G IP67 Ruggedized Router - fig 11
Security Smawave Technology SRP620 5G IP67 Ruggedized Router - fig 12
WPA encryption Smawave Technology SRP620 5G IP67 Ruggedized Router - fig 13
Password? Smawave Technology SRP620 5G IP67 Ruggedized Router - fig14

FAQs

Fails to log in the web management page.
Make sure that the router is powered on.
Verify that the router is correctly connected to the computer through Wi-Fi or a network cable.
If the problem persists, please contact the authorized local service suppliers.
The router fails to search for the wireless network.
Check if the power supply is connected properly.
Check if the router is placed in an open area that is far away from obstructions, such as concrete or wooden walls.
If the problem persists, please contact the authorized local service suppliers.
The parameters are restored to default values.
If the router is powered off unexpectedly while being configured, the parameters may be restored to the default settings.
After configure the parameters, download the configuration file and restore the desired settings quickly.
The router does not support SIM card hot-plug, please confirm that the device is powered off when the SIM card is inserted or removed.
The POWER indicator does not turn on.
Make sure that the power cable is connected properly and the router is powered on.
Make sure that the power supply is compatible with the router.
Labeling requirements.This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modification warning.Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:⑨
-Reorient or relocate the receiving antenna.
⑨ -Increase the separation between the equipment and receiver.
⑨ -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
⑨ -Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End-user must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

The portable device is designed to meet the requirements for exposure to radio waves established by the Federal Communications Commission (USA).
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause unde- sired operation.
This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it also complies with Part 15 of the FCC RF Rules.
This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and consider removing the no-collocation statement.

Documents / Resources

Smawave Technology SRP620 5G IP67 Ruggedized Router [pdf] User Guide
SRP620, 2AU8HSRP620, SRP620 5G IP67 Ruggedized Router, 5G IP67 Ruggedized Router

References

Leave a comment

Your email address will not be published. Required fields are marked *