SMARTRISE MR SRU Replacing Universal Board
Specifications
- Version: 1.0
- Date: March 3, 2025
- Changes: Initial Release
Product Usage Instructions
Installing a New Board
If a board becomes mechanically or electrically faulty, follow these steps:
- Replace the faulty board with a new one.
- Parameters such as timers and learned floor can be retained after replacement.
Retain Parameters for a Replaced MR Board
To transfer parameters from a CT board to a newly replaced MR board:
- Turn off power to the controller.
- Install the new MR SRU board and reattach the connector terminals.
- Turn ON DIPs 5B and 7A.
- Power up the Controller.
- Upon powering up, the MR board will display SYNC IN PROGRESS, and the car will be out of Service.
- When complete, the MR board will display SYNC COMPLETE.
- Turn off the controller.
- Turn OFF DIP 5 B.
- Turn on the controller, and the car will resume normal operation.
Retain Parameters for a Replaced CT or COP Board
To transfer parameters from the MR board to a newly replaced CT or COP board:
- Remove power from the controller.
- Disconnect the connectors and remove the CT or COP board.
- Install the new CT or COP board and reattach the connector terminals.
NOTE: Ensure all DIP switches are set correctly. - Set the CT/COP switch to correspond with the CT or COP board being replaced.
NOTE: The switch is located on the upper-right corner of the board. - Remove LOTO and apply power to the controller. The synchronisation process will begin automatically, as the checksum continuously compares parameters between all three boards.
NOTE: SYNC IN PROGRESS will not be displayed. - Once complete, the CT/COP board will resume normal operation with all parameters retained.