SIRIUS ADJUSTABLE BED
READ THIS INSTRUCTION MANUAL AND OBSERVE SAFETY INSTRUCTIONS BEFORE USE
INSTALLATION GUIDES
ENSURE THE SIRIUS ADJUSTABLE BED AND ALL SLEEPTITE ACCESSORIES ARE INSTALLED AS PER THE FOLLOWING INSTALLATION GUIDES
SIRIUS BED INSTALLATION GUIDE
Step 1: Place the SIRIUS box in the room where the bed will be set up with the Sleeptite logo face up.
Step 2: Remove the plastic bands securing the box in place, cut the tape surrounding the top lid of the box and remove the lid of the box.
Step 3: Cut open plastic wrapping, making sure not to cut into the frame of the bed and remove all cardboard fillers and disguard. Carefully cut all the yellow cable ties.
Step 4: Remove the mattress retainer bar and remote and place to the side. Install supplied batteries into the remote.

Step 5: *OPTIONAL – If you wish to enable short term use of the bed during power failure follow this step*
Remove both cables from the power transformer box.
Remove the screws securing the transformer box and turn it over. Slide off the battery compartment cover & insert 2 x 9V batteries (not supplied) inside. Refit the battery compartment cover.
Refit the transformer box and plug in cords. At this point the bed will enter pairing mode (as indicated by the flashing LEDs). Hold the PAIR button on your remote until flashing stops (approx 5 seconds).
Note: If 2 x 9V batteries are NOT installed pairing is only possible when the bed is plugged into power supply (see step 12).
Step 7: Carefully lift the bed up onto it’s side and remove the bottom part of the box.
Step 8: Ensure the power cable is free and clear of any bars or mechanisms and is not going to be trapped under the bed. Carefully lower the bed onto the floor so the mattress surface is now facing up.
Step 11: Slide the mattress retainer into the slots at the end of the base and secure with c-clip
Step 12: Plug the bed into the wall socket. If not already paired, hold the PAIR button on your remote until LED lights under the bed stop flashing.
FOOTBOARD INSTALLATION GUIDE

Step 1: Raise bed height and footrest to maximum height for ease of access when installing

Step 2: Locate threaded mounting holes on Sirius Footboard (2 per side). Put the longest screw (12cm) alongside the top holes and the shorter screw (10cm) alongside the bottom holes
Step 3: Locate mounting holes on Sirius Base for screw insertion (2 per side at foot end of the bed)
Step 4: Note this step is easier to complete with two people.
Hold the footboard on the outside of the frame with the holes on the footboard lining up with the holes on the Sirius frame.
Insert the longer screws through the top holes on the frame and screw them into the top holes on the footboard
HEADBOARD INSTALLATION GUIDE

Step 1: Raise bed height and knee break to maximum height for ease of access when installing

Step 2: Locate threaded mounting holes on Sirius Headboard (2 per side). Put the longest screw (13.5cm) alongside the top holes and the shorter screw (12cm) alongside the bottom holes

Step 3: Locate mounting holes on Sirius Base for screw insertion (2 per side at head end of the bed)
Step 4: Note this step is easier to complete with two people.
Hold the headboard on the outside of the frame with the holes on the headboard lining up with the holes on the Sirius frame.
Insert the longer screws through the top holes on the frame and screw them into the top holes on the headboard
BEDSTICK WITH RETURN INSTALLATION GUIDE

Kit Contains: Bed Stick, Stabalisation plate (King Single – large OR Long Single – small), 2 x black stand off spacers, 2 x Button Head Cap Screws, 2 x Nyloc Nut, 4 x Flat Washer, 1 x Raised Countersink Screw
Tools required: 19mm spanner, 8mm allen key, 4mm allen key, 13mm socket wrench
Step 1: Ensure there is no mattress or occupant on the SIRIUS bed. Raise bed height to a comfortable height for ease of access when installing.
Step 2: Remove the fabric button covers from the side of the SIRIUS base you wish to install the bed stick.

Step 3: Use a socket wrench to remove the 4 bolts from under the bed surrounding either the power supply unit or the control box (depending on installation side) – do not discard the bolts.

Step 4: Attach the Stabalisation plate to the bed stick using the raised countersunk screw through the hole in the handle. The Stabalisation plate needs to be installed so the bolt hole (circled) is angled towards the head of the bed frame. Ensure the screw is still quite loose to enable the plate to slide into the correct position.
Step 5: Lift up bed stick in line with the pre drilled holes on the bed frame (where you took the fabric buttons out).
Step 6: Lift the top section of the base to create a gap and slide the stabilisation plate through the gap.

Step 7: Put the flat washer on the button cap screw, push the screw through the hole on foot end of the bed stick. Insert the black spacer onto the other side and push into the open hole on the base. Place the washer and nut on the side of the button head screw that is on the inside of the bed. Repeat on head end – hand tighten only at this point.
Step 8: Line up the top hole on the stabalisation plate with outer hole at the bedhead end of the control box or power supply unit. If the hole on the stabalisation plate does not align with the hole on the bed base, loosen the countersunk screw on the bed handle to enable more movement.
Step 9: Re-install the 4 bolts previously removed from the control box or power supply unit, starting with the bolt that goes through the stabilisation plate. Do not fully tighten yet.

Step 10: Tighten both the button head bolts (on the outer beam) using both the 8mm allen key and 19mm spanner.
Step 11: Tighten the bolts around the control box or power supply unit.

Step 12: Tighten the screw placed through the handle of the bed stick with 4mm allen key (do not overtighten).

REMOTE QUICK GUIDE
SCAN QR CODE FOR A MORE DETAILED REMOTE INSTRUCTION MANUAL
NOTE: If manually turning the power off on the SIRIUS adjustable bed please first put it into Caster position to ensure correct control box recalibration occurs once the power has been reinstated.
PAIRING REMOTE TO CONTROL BOX
- Put in 3 x AAA batteries
- Locate PAIR button on Remote and hold down until under bed light stops flashing (5-10 seconds).
- Press a button on the remote to check pairing was successful. If not succesfull follow next step.
- Disconnect power for 1 minute. Reconnect power and follow steps 1 – 3.
SETTING MEMORY POSITIONS
- Put the bed into the position you want to save on the allocated memory button.
- Hold the allocated Memory button for 5-10 seconds.
- Put bed into flat position.
- Press the memory button just programmed and the bed will move into programmed position
GENERAL INFORMATION
CAUTIONS
Please read the contents of this instruction manual carefully prior to using the Sleeptite Sirius Bed (“the bed”).
In the event the bed changes owners, please supply this instruction manual to the new owner.
When the bed is moved on the transport frame take care not to allow it to tip over. Please check all fixings on your bed at least once per month. Pay special attention to sleeping platform bolts.
Before cleaning and disinfection, the mains plug must be disconnected and hung safely. Plugs for the handset and the motors which are inserted into the mattress base control box and the motor unit must remain plugged in. This is necessary to prevent water ingress to the control box. If manually turning the power off please ensure the bed is in Castor position before doing so – this will help ensure the control box re-calibrates correctly upon turning power back on. If power unexpectedly turns off when bed is in Chair or Reverse Trendelenburg position ensure you take the bed to full height before returning it to Caster position to ensure correct control box recalibration occurs once the power has been reinstated.
Do not sit on the leg section of the bed when operating the raise function. Ensure the recommended service and maintenance schedule in this manual is completed. Failure to do so may void warranty claims.
WARNINGS
Before lowering the bed check the area underneath is clear. Any obstructing article could be damaged or could cause instability to the bed.
Take care when lowering the bed to ensure limbs of any person or other objects present do not become trapped under the bed.
Do not store the power supply under the bed.
1.1 INTENDED PURPOSE
USE FOR THE PURPOSE INTENDED (APPLICATION ENVIRONMENT)
The SIRIUS Adjustable Bed is intended for accommodating users in home care and residential care environments and may only be used under the conditions for use described in this Instruction Manual.
Any other use shall be regarded as non-compliant with the regulations and is excluded from any liability.
ATTENTION: The SIRIUS Adjustable Bed is not suitable for medical electrical applications which involve intravascular or intercardiac processes with the patient.
The SIRIUS Adjustable Bed is not designed for the transport of users.
If other electrical devices are used in the bed and to prevent the risk of an electrical shock, protective measures and precautions must be established to prevent power cords being trapped in articulating parts of the bed.
1.2 NON-COMPLIANT USE
All uses deviating from the intended purpose, which may also be hazardous as a result.
This includes for example:
- Loading the bed beyond the safe admissible working load of 200Kg.
- Operation of the bed by users who have not been instructed in its use.
- Attempting to move the bed when castors are braked (if optional castors are purchased).
- Use of the bed on a non-horizontal surface (max. incline 5°).
SAFETY INSTRUCTIONS
The following instructions are a non-exhaustive list of recommendations for the safe use of the bed.
- Before putting the bed into service for the first time, the Instruction Manual must be read in detail by the user / care personnel.
- If manually turning the power off please ensure the bed is in Castor position before doing so – this will help ensure the control box re-calibrates correctly upon turning power back on.
- If power unexpectedly turns off when bed is in Chair or Reverse Trendelenburg position ensure you take the bed to full height before returning it to Caster position to ensure correct control box recalibration occurs once the power has been reinstated.
- Never store anything under the bed.
- Do not put the bed into Chair Position or Reverse Trendelenburg position directly from the Castor position
- Check no pets are under the bed before operating any of the functions.
- Do not sit on the leg section of the bed when operating the raise function.
- Specific attention must be drawn to any potential dangers which can occur despite correct operation.
- When operating the adjusting functions, there must not be any objects or limbs in the area of movement of the bed or where there is risk of crushing.
- Adjustments to the bed must only be carried out by suitably instructed persons or in the presence of an instructed person.
- Unplug the mains plug from the socket before moving the bed and take care to avoid dragging the mains plug across the floor when moving the bed.
- The mains plug must always remain accessible to enable immediate cut-off by unplugging the mains plug from the wall socket in case of emergency. The mains cable must be free and away from the bed frame. Otherwise, the mains cable may be torn out and damaged. In addition, the mains plug may be pulled out of its socket and electric leads exposed as a result. If the mains cable or the mains plug is damaged, the relevant part must be replaced. This work should only be carried out by the manufacturer or authorised professionals.
- When connecting the mains plug, do not use multiple sockets as liquids may penetrate into these causing potential fire hazard and electric shock.
- The maximum duty cycle and the safe working load must not be exceeded otherwise safe operation cannot be guaranteed.
- The bed must not be used in rooms where there is a risk of explosion or hazardous materials and chemicals are stored.
- Always supervise children if they are operating the control system If using optional castor legs
- When the bed is stationary the castors must always be in the braked position. If the castors are not braked, the bed can move during occupant egress and igress.
- In order to move the bed, the brakes on all four castors must be released
SAFETY INFORMATION FOR THE OPERATOR
With the help of this Instruction Manual, instruct each user in the safe operation of this bed before it is put into service for the first time.
Advise the user of any hazards which may occur if not handled correctly.
Only persons who have been properly instructed may operate the bed. This also applies for persons who only operate the bed on a temporary basis.
According to section 41B of the Therapeutic Goods Act 1989, this bed is Class I medical device.
Please observe your obligations as the operator in accordance with the Therapeutic Goods Act Products Ordinance, in order to ensure the permanently safe operation of this medical product with no risk of danger to patients, users or third parties.
If the bed is used on a long-term basis, checks for proper functioning and for any visi- ble damage must be performed and documented at least once a year.
3.1 SAFETY INFORMATION FOR THE END USER
Ensure the operator instructs you in the safe operation of this bed. In addition, pay particular attention to the general safety information as described in safety instructions on previous page.
Adjustments of the bed must only be carried out by suitably instructed persons or in the presence of an instructed person.
If there is a suspected fault or damage, unplug the mains plug from the socket and immediately take it out of service and notify revelent person (ie carer, facility manager etc).
CLEANING & MAITENANCE
CLEANING & DISINFECTION
Before cleaning and disinfection unplug the mains plug and hang safely. Plugs for the handset and the motors which are plugged into the control box must remain in their sockets to prevent water from getting into the control system.
Do not immerse electrical components in water but wipe them with a damp cloth. Do not use a high pressure cleaner or any other motorised cleaning devises.
Only disinfection by wiping is allowed.
Wear waterproof gloves when cleaning and disinfecting to avoid skin irritation.
Attention: In the event of disinfection by spraying on a large scale with products containing alcohol there is a danger of explosion and fire.
SERVICING & MAINTENANCE
Servicing work must only be carried out by persons who are suitably qualified. A technical check and/or safety inspection must be conducted at least once a year irrespective of frequency of use.
Any defects, damage or signs of wear must be rectified without delay.
Only original spare parts from Sleeptite may be used, otherwise all guarantees or warranties will be excluded.
Please check all fixings on your bed at least once a month. Pay special attention to sleeping platform bolts.
OTHER INFORMATION
OPTIONAL EXTRAS
The optional accessories available to attached to Sirius include: bed stick with return, foldable side rails, 150mm optional leg with lockable castor, matching fabric headboard and footboard.
TRANSPORT
It can be maneuvered on its in-built castors. When the bed is moved on the transport frame take care not to allow it to overbalance.
SERVICE LIFE & DISPOSAL
The normal service life for care beds in domestic use is approximately 10 years. The care bed must not be disposed of as normal domestic waste after its service life has expired.
To ensure that it is disposed of in an environmentally compatible way please contact Sleeptite.
TROUBLESHOOTING
| FAULT | POSSIBLE CAUSE | SOLUTION |
| No Response | Main plug not plugged in | Insert mains plug into socket |
| No Response | Locking function on handset activated | Unlock handset |
| No Response | Handset battery | Insert new batteries into handset |
| No Response | Motor unit not plugged in | Plug motor unit into bed base motor |
| Adjustment functions transposed | Connecting cables on the connectors transposed | Check plugs and connectors are firmly connected to the control box |
| No function after power failure | Control Box error | Repair the control box with the remote |
IN CASE OF AN UNEXPECTED POWER OUTAGE
In case of power outage, or other control box failures resulting in the bed functionality not returning to standard operating functions please follow the below steps:
Put the bed into Caster (floor-line) position**. Depending on the position the bed starts in (when power outage occurred) this may require pressing multiple function buttons.
Once the bed is in Caster position turn the bed off at the wall socket power supply.
Leave the bed off for a minimum of 2 minutes to allow control box to reset.
Turn power supply back on. Re-Pair the remote by holding the pair button down for a minimum of 10 seconds.
Bring the bed to “home position”
Remote functionality should now return to normal.
** If power turns off when bed is in Chair or Reverse Trendelenburg position ensure you take the bed to full height before returning it to Caster position.
WARRANTY
The Warranty on the SIRIUS Adjustable bed is as follows:
10 Years – Frame
3 Years – Motors and Electronics
Please visit our website for more information www.sleeptite.com.au
SERVICE LIFE & DISPOSAL
The service life of the bed is 10 years (frame) 3 years (Motors and Electonics)
To guarantee safe operation, a visual and functional test including an electrical test must be carried out at least once a year.
If there is any doubt about the safety or functionality of the bed or even a part of the bed as a result of the work performed below, the bed should under no circumstances be in service again.
Frequent transportation, setting up and adjustment may impact the service life, as does improper treatment, irregular servicing and exceeding the safe working load or the admissible load cycle of the electric motors.
The bed must not be disposed of as normal household waste after the end of its service life. To ensure that it is disposed of in an environmentally compatible way please contact Sleeptite or authorised representative. Never store anything under the bed.
TECHNICAL SPECIFICATIONS
TECHNICAL DATA (MECHANICAL)
| Sleep Surface Single Long | 920mm x 2030mm |
| Sleep Surface King Single | 1070mm x 2030mm |
| Sleep Surface Height Range | 200mm – 750mm |
| Overall Length | 2030mm |
| Overall Width | 920mm (Single Long) 1070mm (King Single) |
| Safe Working Load | 200kg |
| Underbed Clearance | 100mm -150mm* with lockable castor accessory |
| Knee Bend Range | 0° to 38° |
| Backrest Range | 0° to 70° |
| Product Weight Single Long | 96kg |
TECHNICAL DATA (ELECTONIC)
Power supply unit Dewert/ OKIN
Voltage rating 230/240V
Frequency rating 50-60 Hz
Type of current AC ~
Nominal consumption during operation 70 Watt
Nominal consumption in idle state 0.5 Watt
Primary safety fuse 2.0 A
TECHNICAL DATA (ENVIRONMENT)
Temperature range during operation +10°C to + 40°C
Temperature range for storage/transport -10°C to + 60°C
Humidity of the air 30% to 75% rel.
Air pressure Between 795 and 1060 hPa
PURCHASE INFORMATION
PUCHASE DATE
PURCHASE STORE
SIRIUS ADJUSTABLE BED BARCODE (located on the frame)
ATTACH RECEIPT HERE
/SleeptiteAus
/sleeptite
/sleeptite_aus
/sleeptite_aus
Product Enquiries
info@sleeptite.com.au
Sleeptite Pty Ltd
10b Heland Place
BRAESIDE VIC 3195
Documents / Resources
![]() |
Sleeptite Sirius Adjustable Bed [pdf] Instruction Manual Sirius Adjustable Bed, Sirius, Adjustable Bed, Bed |